FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
Germany

Aspect Quality

Erwin-Seiz-Straße 9, 72764, Reutlingen, Germany

DAKKS|D-PL-22860-01-00DAKKS|D-PL-22860-01-01ISO/IEC 17025Register refreshed 2026-09-25
Certificates
2
Scope items
12
Standards
26
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Contact this laboratory

No contact information available

Open DAKKS register entry
Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Aspect Quality?

Claim this profile to keep it accurate.

Register record

DAKKSRefreshed
D-PL-22860-01-00Active
D-PL-22860-01-01Active

Accredited standards

26

Our reading of the DAKKS scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

IEC 60068 series

IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
As written on the certificate · Line 3 (DAKKS D-PL-22860-01-01)

DIN 55635:2019-05; DIN 75220:1992-11; DIN EN 60068-2-1:2008-01; VDE 0468-2-1:2008-01; DIN EN 60068-2-2:2008-05; VDE 0468-2-2:2008-05; DIN EN IEC 60068-2-5:2019-02; VDE 0468-2-5:2019-02; DIN EN IEC 60068-2-11:2022-10; VDE 0468-2-11:2022-10; DIN EN IEC 60068-2-14:2025-03; VDE 0468-2-14:2025-03

As written on the certificate · Line 9 (DAKKS D-PL-22860-01-01)

DIN EN 60068-2-1; DIN EN 60068-2-2; DIN EN IEC 60068-2-14 Na; DIN EN IEC 60068-2-14 Nb; DIN EN 60068-2-67; DIN EN 60068-2-78; DIN EN 60068-2-30; DIN EN IEC 60068-2-38; DIN 75220; DIN EN IEC 60068-2-5; VDE 0468-2-5; DIN EN ISO 4892-2; DIN EN ISO 105-B06

IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
As written on the certificate · Line 3 (DAKKS D-PL-22860-01-01)

DIN 55635:2019-05; DIN 75220:1992-11; DIN EN 60068-2-1:2008-01; VDE 0468-2-1:2008-01; DIN EN 60068-2-2:2008-05; VDE 0468-2-2:2008-05; DIN EN IEC 60068-2-5:2019-02; VDE 0468-2-5:2019-02; DIN EN IEC 60068-2-11:2022-10; VDE 0468-2-11:2022-10; DIN EN IEC 60068-2-14:2025-03; VDE 0468-2-14:2025-03

As written on the certificate · Line 9 (DAKKS D-PL-22860-01-01)

DIN EN 60068-2-1; DIN EN 60068-2-2; DIN EN IEC 60068-2-14 Na; DIN EN IEC 60068-2-14 Nb; DIN EN 60068-2-67; DIN EN 60068-2-78; DIN EN 60068-2-30; DIN EN IEC 60068-2-38; DIN 75220; DIN EN IEC 60068-2-5; VDE 0468-2-5; DIN EN ISO 4892-2; DIN EN ISO 105-B06

IEC 60068-2-5Name not checked yet
As written on the certificate · Line 3 (DAKKS D-PL-22860-01-01)

DIN 55635:2019-05; DIN 75220:1992-11; DIN EN 60068-2-1:2008-01; VDE 0468-2-1:2008-01; DIN EN 60068-2-2:2008-05; VDE 0468-2-2:2008-05; DIN EN IEC 60068-2-5:2019-02; VDE 0468-2-5:2019-02; DIN EN IEC 60068-2-11:2022-10; VDE 0468-2-11:2022-10; DIN EN IEC 60068-2-14:2025-03; VDE 0468-2-14:2025-03

As written on the certificate · Line 9 (DAKKS D-PL-22860-01-01)

DIN EN 60068-2-1; DIN EN 60068-2-2; DIN EN IEC 60068-2-14 Na; DIN EN IEC 60068-2-14 Nb; DIN EN 60068-2-67; DIN EN 60068-2-78; DIN EN 60068-2-30; DIN EN IEC 60068-2-38; DIN 75220; DIN EN IEC 60068-2-5; VDE 0468-2-5; DIN EN ISO 4892-2; DIN EN ISO 105-B06

IEC 60068-2-11Environmental testing - Part 2-11: Tests - Test Ka: Salt mist
As written on the certificate · Line 3 (DAKKS D-PL-22860-01-01)

DIN 55635:2019-05; DIN 75220:1992-11; DIN EN 60068-2-1:2008-01; VDE 0468-2-1:2008-01; DIN EN 60068-2-2:2008-05; VDE 0468-2-2:2008-05; DIN EN IEC 60068-2-5:2019-02; VDE 0468-2-5:2019-02; DIN EN IEC 60068-2-11:2022-10; VDE 0468-2-11:2022-10; DIN EN IEC 60068-2-14:2025-03; VDE 0468-2-14:2025-03

As written on the certificate · Line 10 (DAKKS D-PL-22860-01-01)

DIN EN IEC 60068-2-11; DIN EN ISO 9227, NSS; ASTM B117-19; DIN EN ISO 9227, AASS; ASTM G85-19; DIN EN IEC 60068-2-52; SAE J2334; VDA 233-102; VDA 621-415; DIN EN ISO 11997-1; DIN EN ISO 11997-3; ISO 14993; ISO 19453-6; DIN EN ISO 6270-2; DIN EN 60068-2-31; ISO 16750-5

IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
As written on the certificate · Line 3 (DAKKS D-PL-22860-01-01)

DIN 55635:2019-05; DIN 75220:1992-11; DIN EN 60068-2-1:2008-01; VDE 0468-2-1:2008-01; DIN EN 60068-2-2:2008-05; VDE 0468-2-2:2008-05; DIN EN IEC 60068-2-5:2019-02; VDE 0468-2-5:2019-02; DIN EN IEC 60068-2-11:2022-10; VDE 0468-2-11:2022-10; DIN EN IEC 60068-2-14:2025-03; VDE 0468-2-14:2025-03

As written on the certificate · Line 9 (DAKKS D-PL-22860-01-01)

DIN EN 60068-2-1; DIN EN 60068-2-2; DIN EN IEC 60068-2-14 Na; DIN EN IEC 60068-2-14 Nb; DIN EN 60068-2-67; DIN EN 60068-2-78; DIN EN 60068-2-30; DIN EN IEC 60068-2-38; DIN 75220; DIN EN IEC 60068-2-5; VDE 0468-2-5; DIN EN ISO 4892-2; DIN EN ISO 105-B06

IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
As written on the certificate · Line 4 (DAKKS D-PL-22860-01-01)

DIN EN 60068-2-30:2006-06; DIN EN 60068-2-31:2009-04; VDE 0468-2-31:2009-04; DIN EN IEC 60068-2-38:2022-09; VDE 0468-2-38:2022-09; DIN EN IEC 60068-2-52:2018-08; VDE 0468-2-52:2018-08; DIN EN 60068-2-61:1993-12; DIN EN 60068-2-67:2020-08; VDE 0468-2-67 2020-08

As written on the certificate · Line 9 (DAKKS D-PL-22860-01-01)

DIN EN 60068-2-1; DIN EN 60068-2-2; DIN EN IEC 60068-2-14 Na; DIN EN IEC 60068-2-14 Nb; DIN EN 60068-2-67; DIN EN 60068-2-78; DIN EN 60068-2-30; DIN EN IEC 60068-2-38; DIN 75220; DIN EN IEC 60068-2-5; VDE 0468-2-5; DIN EN ISO 4892-2; DIN EN ISO 105-B06

IEC 60068-2-31Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens
As written on the certificate · Line 4 (DAKKS D-PL-22860-01-01)

DIN EN 60068-2-30:2006-06; DIN EN 60068-2-31:2009-04; VDE 0468-2-31:2009-04; DIN EN IEC 60068-2-38:2022-09; VDE 0468-2-38:2022-09; DIN EN IEC 60068-2-52:2018-08; VDE 0468-2-52:2018-08; DIN EN 60068-2-61:1993-12; DIN EN 60068-2-67:2020-08; VDE 0468-2-67 2020-08

As written on the certificate · Line 10 (DAKKS D-PL-22860-01-01)

DIN EN IEC 60068-2-11; DIN EN ISO 9227, NSS; ASTM B117-19; DIN EN ISO 9227, AASS; ASTM G85-19; DIN EN IEC 60068-2-52; SAE J2334; VDA 233-102; VDA 621-415; DIN EN ISO 11997-1; DIN EN ISO 11997-3; ISO 14993; ISO 19453-6; DIN EN ISO 6270-2; DIN EN 60068-2-31; ISO 16750-5

IEC 60068-2-38Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test
As written on the certificate · Line 4 (DAKKS D-PL-22860-01-01)

DIN EN 60068-2-30:2006-06; DIN EN 60068-2-31:2009-04; VDE 0468-2-31:2009-04; DIN EN IEC 60068-2-38:2022-09; VDE 0468-2-38:2022-09; DIN EN IEC 60068-2-52:2018-08; VDE 0468-2-52:2018-08; DIN EN 60068-2-61:1993-12; DIN EN 60068-2-67:2020-08; VDE 0468-2-67 2020-08

As written on the certificate · Line 9 (DAKKS D-PL-22860-01-01)

DIN EN 60068-2-1; DIN EN 60068-2-2; DIN EN IEC 60068-2-14 Na; DIN EN IEC 60068-2-14 Nb; DIN EN 60068-2-67; DIN EN 60068-2-78; DIN EN 60068-2-30; DIN EN IEC 60068-2-38; DIN 75220; DIN EN IEC 60068-2-5; VDE 0468-2-5; DIN EN ISO 4892-2; DIN EN ISO 105-B06

IEC 60068-2-52Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution)
As written on the certificate · Line 4 (DAKKS D-PL-22860-01-01)

DIN EN 60068-2-30:2006-06; DIN EN 60068-2-31:2009-04; VDE 0468-2-31:2009-04; DIN EN IEC 60068-2-38:2022-09; VDE 0468-2-38:2022-09; DIN EN IEC 60068-2-52:2018-08; VDE 0468-2-52:2018-08; DIN EN 60068-2-61:1993-12; DIN EN 60068-2-67:2020-08; VDE 0468-2-67 2020-08

As written on the certificate · Line 10 (DAKKS D-PL-22860-01-01)

DIN EN IEC 60068-2-11; DIN EN ISO 9227, NSS; ASTM B117-19; DIN EN ISO 9227, AASS; ASTM G85-19; DIN EN IEC 60068-2-52; SAE J2334; VDA 233-102; VDA 621-415; DIN EN ISO 11997-1; DIN EN ISO 11997-3; ISO 14993; ISO 19453-6; DIN EN ISO 6270-2; DIN EN 60068-2-31; ISO 16750-5

IEC 60068-2-61Name not checked yet
As written on the certificate · Line 4 (DAKKS D-PL-22860-01-01)

DIN EN 60068-2-30:2006-06; DIN EN 60068-2-31:2009-04; VDE 0468-2-31:2009-04; DIN EN IEC 60068-2-38:2022-09; VDE 0468-2-38:2022-09; DIN EN IEC 60068-2-52:2018-08; VDE 0468-2-52:2018-08; DIN EN 60068-2-61:1993-12; DIN EN 60068-2-67:2020-08; VDE 0468-2-67 2020-08

IEC 60068-2-67Name not checked yet
As written on the certificate · Line 4 (DAKKS D-PL-22860-01-01)

DIN EN 60068-2-30:2006-06; DIN EN 60068-2-31:2009-04; VDE 0468-2-31:2009-04; DIN EN IEC 60068-2-38:2022-09; VDE 0468-2-38:2022-09; DIN EN IEC 60068-2-52:2018-08; VDE 0468-2-52:2018-08; DIN EN 60068-2-61:1993-12; DIN EN 60068-2-67:2020-08; VDE 0468-2-67 2020-08

As written on the certificate · Line 9 (DAKKS D-PL-22860-01-01)

DIN EN 60068-2-1; DIN EN 60068-2-2; DIN EN IEC 60068-2-14 Na; DIN EN IEC 60068-2-14 Nb; DIN EN 60068-2-67; DIN EN 60068-2-78; DIN EN 60068-2-30; DIN EN IEC 60068-2-38; DIN 75220; DIN EN IEC 60068-2-5; VDE 0468-2-5; DIN EN ISO 4892-2; DIN EN ISO 105-B06

IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
As written on the certificate · Line 5 (DAKKS D-PL-22860-01-01)

DIN EN 60068-2-78: 2014-02; VDE 0468-2-78: 2014-02; DIN EN ISO 4892-2: 2021-11; DIN EN ISO 6270-2: 2018-04; DIN EN ISO 9227: 2024-10; DIN EN ISO 11997-1: 2018-01; DIN EN ISO 11997-3: 2024-01

As written on the certificate · Line 9 (DAKKS D-PL-22860-01-01)

DIN EN 60068-2-1; DIN EN 60068-2-2; DIN EN IEC 60068-2-14 Na; DIN EN IEC 60068-2-14 Nb; DIN EN 60068-2-67; DIN EN 60068-2-78; DIN EN 60068-2-30; DIN EN IEC 60068-2-38; DIN 75220; DIN EN IEC 60068-2-5; VDE 0468-2-5; DIN EN ISO 4892-2; DIN EN ISO 105-B06

ISO

ISO 105-B06Textiles - Tests for colour fastness - Part B06: Colour fastness and ageing to artificial light at high temperatures: Xenon arc fading lamp test
As written on the certificate · Line 6 (DAKKS D-PL-22860-01-01)

DIN EN ISO 105-B06:2020-12; ISO 14993:2018-07; ISO 16750-4:2023-07; ISO 16750-5:2023-07; VDA 233-102 2013-06; VDA 621-415 1982-02; ASTM B117-19 2019-12; ASTM G85-19 2019-12; SAE J2334 2016-04; VW 51500-1 2025-05

As written on the certificate · Line 9 (DAKKS D-PL-22860-01-01)

DIN EN 60068-2-1; DIN EN 60068-2-2; DIN EN IEC 60068-2-14 Na; DIN EN IEC 60068-2-14 Nb; DIN EN 60068-2-67; DIN EN 60068-2-78; DIN EN 60068-2-30; DIN EN IEC 60068-2-38; DIN 75220; DIN EN IEC 60068-2-5; VDE 0468-2-5; DIN EN ISO 4892-2; DIN EN ISO 105-B06

ISO 4892-2Plastics - Methods of exposure to laboratory light sources - Part 2: Xenon-arc lamps
As written on the certificate · Line 5 (DAKKS D-PL-22860-01-01)

DIN EN 60068-2-78: 2014-02; VDE 0468-2-78: 2014-02; DIN EN ISO 4892-2: 2021-11; DIN EN ISO 6270-2: 2018-04; DIN EN ISO 9227: 2024-10; DIN EN ISO 11997-1: 2018-01; DIN EN ISO 11997-3: 2024-01

As written on the certificate · Line 9 (DAKKS D-PL-22860-01-01)

DIN EN 60068-2-1; DIN EN 60068-2-2; DIN EN IEC 60068-2-14 Na; DIN EN IEC 60068-2-14 Nb; DIN EN 60068-2-67; DIN EN 60068-2-78; DIN EN 60068-2-30; DIN EN IEC 60068-2-38; DIN 75220; DIN EN IEC 60068-2-5; VDE 0468-2-5; DIN EN ISO 4892-2; DIN EN ISO 105-B06

ISO 6270-2Paints and varnishes - Determination of resistance to humidity - Part 2: Condensation (in-cabinet exposure with heated water reservoir)
As written on the certificate · Line 5 (DAKKS D-PL-22860-01-01)

DIN EN 60068-2-78: 2014-02; VDE 0468-2-78: 2014-02; DIN EN ISO 4892-2: 2021-11; DIN EN ISO 6270-2: 2018-04; DIN EN ISO 9227: 2024-10; DIN EN ISO 11997-1: 2018-01; DIN EN ISO 11997-3: 2024-01

As written on the certificate · Line 10 (DAKKS D-PL-22860-01-01)

DIN EN IEC 60068-2-11; DIN EN ISO 9227, NSS; ASTM B117-19; DIN EN ISO 9227, AASS; ASTM G85-19; DIN EN IEC 60068-2-52; SAE J2334; VDA 233-102; VDA 621-415; DIN EN ISO 11997-1; DIN EN ISO 11997-3; ISO 14993; ISO 19453-6; DIN EN ISO 6270-2; DIN EN 60068-2-31; ISO 16750-5

ISO 9227Corrosion tests in artificial atmospheres - Salt spray tests
As written on the certificate · Line 5 (DAKKS D-PL-22860-01-01)

DIN EN 60068-2-78: 2014-02; VDE 0468-2-78: 2014-02; DIN EN ISO 4892-2: 2021-11; DIN EN ISO 6270-2: 2018-04; DIN EN ISO 9227: 2024-10; DIN EN ISO 11997-1: 2018-01; DIN EN ISO 11997-3: 2024-01

As written on the certificate · Line 10 (DAKKS D-PL-22860-01-01)

DIN EN IEC 60068-2-11; DIN EN ISO 9227, NSS; ASTM B117-19; DIN EN ISO 9227, AASS; ASTM G85-19; DIN EN IEC 60068-2-52; SAE J2334; VDA 233-102; VDA 621-415; DIN EN ISO 11997-1; DIN EN ISO 11997-3; ISO 14993; ISO 19453-6; DIN EN ISO 6270-2; DIN EN 60068-2-31; ISO 16750-5

ISO 11997-1Paints and varnishes - Determination of resistance to cyclic corrosion conditions - Part 1: Wet (salt fog)/dry/humid
As written on the certificate · Line 5 (DAKKS D-PL-22860-01-01)

DIN EN 60068-2-78: 2014-02; VDE 0468-2-78: 2014-02; DIN EN ISO 4892-2: 2021-11; DIN EN ISO 6270-2: 2018-04; DIN EN ISO 9227: 2024-10; DIN EN ISO 11997-1: 2018-01; DIN EN ISO 11997-3: 2024-01

As written on the certificate · Line 10 (DAKKS D-PL-22860-01-01)

DIN EN IEC 60068-2-11; DIN EN ISO 9227, NSS; ASTM B117-19; DIN EN ISO 9227, AASS; ASTM G85-19; DIN EN IEC 60068-2-52; SAE J2334; VDA 233-102; VDA 621-415; DIN EN ISO 11997-1; DIN EN ISO 11997-3; ISO 14993; ISO 19453-6; DIN EN ISO 6270-2; DIN EN 60068-2-31; ISO 16750-5

ISO 11997-3Paints and varnishes - Determination of resistance to cyclic corrosion conditions - Part 3: Testing of coating systems on materials and components in automotive construction
As written on the certificate · Line 5 (DAKKS D-PL-22860-01-01)

DIN EN 60068-2-78: 2014-02; VDE 0468-2-78: 2014-02; DIN EN ISO 4892-2: 2021-11; DIN EN ISO 6270-2: 2018-04; DIN EN ISO 9227: 2024-10; DIN EN ISO 11997-1: 2018-01; DIN EN ISO 11997-3: 2024-01

As written on the certificate · Line 10 (DAKKS D-PL-22860-01-01)

DIN EN IEC 60068-2-11; DIN EN ISO 9227, NSS; ASTM B117-19; DIN EN ISO 9227, AASS; ASTM G85-19; DIN EN IEC 60068-2-52; SAE J2334; VDA 233-102; VDA 621-415; DIN EN ISO 11997-1; DIN EN ISO 11997-3; ISO 14993; ISO 19453-6; DIN EN ISO 6270-2; DIN EN 60068-2-31; ISO 16750-5

ISO 14993Corrosion of metals and alloys - Accelerated testing involving cyclic exposure to salt mist, dry and wet conditions
As written on the certificate · Line 6 (DAKKS D-PL-22860-01-01)

DIN EN ISO 105-B06:2020-12; ISO 14993:2018-07; ISO 16750-4:2023-07; ISO 16750-5:2023-07; VDA 233-102 2013-06; VDA 621-415 1982-02; ASTM B117-19 2019-12; ASTM G85-19 2019-12; SAE J2334 2016-04; VW 51500-1 2025-05

As written on the certificate · Line 10 (DAKKS D-PL-22860-01-01)

DIN EN IEC 60068-2-11; DIN EN ISO 9227, NSS; ASTM B117-19; DIN EN ISO 9227, AASS; ASTM G85-19; DIN EN IEC 60068-2-52; SAE J2334; VDA 233-102; VDA 621-415; DIN EN ISO 11997-1; DIN EN ISO 11997-3; ISO 14993; ISO 19453-6; DIN EN ISO 6270-2; DIN EN 60068-2-31; ISO 16750-5

ISO 16750-4Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 4: Climatic loads
As written on the certificate · Line 6 (DAKKS D-PL-22860-01-01)

DIN EN ISO 105-B06:2020-12; ISO 14993:2018-07; ISO 16750-4:2023-07; ISO 16750-5:2023-07; VDA 233-102 2013-06; VDA 621-415 1982-02; ASTM B117-19 2019-12; ASTM G85-19 2019-12; SAE J2334 2016-04; VW 51500-1 2025-05

ISO 16750-5Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 5: Chemical loads
As written on the certificate · Line 6 (DAKKS D-PL-22860-01-01)

DIN EN ISO 105-B06:2020-12; ISO 14993:2018-07; ISO 16750-4:2023-07; ISO 16750-5:2023-07; VDA 233-102 2013-06; VDA 621-415 1982-02; ASTM B117-19 2019-12; ASTM G85-19 2019-12; SAE J2334 2016-04; VW 51500-1 2025-05

As written on the certificate · Line 10 (DAKKS D-PL-22860-01-01)

DIN EN IEC 60068-2-11; DIN EN ISO 9227, NSS; ASTM B117-19; DIN EN ISO 9227, AASS; ASTM G85-19; DIN EN IEC 60068-2-52; SAE J2334; VDA 233-102; VDA 621-415; DIN EN ISO 11997-1; DIN EN ISO 11997-3; ISO 14993; ISO 19453-6; DIN EN ISO 6270-2; DIN EN 60068-2-31; ISO 16750-5

ISO 19453-6Road vehicles - Environmental conditions and testing for electrical and electronic equipment for drive system of electric propulsion vehicles - Part 6: Traction battery packs and systems
As written on the certificate · Line 10 (DAKKS D-PL-22860-01-01)

DIN EN IEC 60068-2-11; DIN EN ISO 9227, NSS; ASTM B117-19; DIN EN ISO 9227, AASS; ASTM G85-19; DIN EN IEC 60068-2-52; SAE J2334; VDA 233-102; VDA 621-415; DIN EN ISO 11997-1; DIN EN ISO 11997-3; ISO 14993; ISO 19453-6; DIN EN ISO 6270-2; DIN EN 60068-2-31; ISO 16750-5

Other standards

ASTM B117Standard Practice for Operating Salt Spray (Fog) Apparatus
As written on the certificate · Line 6 (DAKKS D-PL-22860-01-01)

DIN EN ISO 105-B06:2020-12; ISO 14993:2018-07; ISO 16750-4:2023-07; ISO 16750-5:2023-07; VDA 233-102 2013-06; VDA 621-415 1982-02; ASTM B117-19 2019-12; ASTM G85-19 2019-12; SAE J2334 2016-04; VW 51500-1 2025-05

As written on the certificate · Line 10 (DAKKS D-PL-22860-01-01)

DIN EN IEC 60068-2-11; DIN EN ISO 9227, NSS; ASTM B117-19; DIN EN ISO 9227, AASS; ASTM G85-19; DIN EN IEC 60068-2-52; SAE J2334; VDA 233-102; VDA 621-415; DIN EN ISO 11997-1; DIN EN ISO 11997-3; ISO 14993; ISO 19453-6; DIN EN ISO 6270-2; DIN EN 60068-2-31; ISO 16750-5

ASTM G85Name not checked yet
As written on the certificate · Line 6 (DAKKS D-PL-22860-01-01)

DIN EN ISO 105-B06:2020-12; ISO 14993:2018-07; ISO 16750-4:2023-07; ISO 16750-5:2023-07; VDA 233-102 2013-06; VDA 621-415 1982-02; ASTM B117-19 2019-12; ASTM G85-19 2019-12; SAE J2334 2016-04; VW 51500-1 2025-05

As written on the certificate · Line 10 (DAKKS D-PL-22860-01-01)

DIN EN IEC 60068-2-11; DIN EN ISO 9227, NSS; ASTM B117-19; DIN EN ISO 9227, AASS; ASTM G85-19; DIN EN IEC 60068-2-52; SAE J2334; VDA 233-102; VDA 621-415; DIN EN ISO 11997-1; DIN EN ISO 11997-3; ISO 14993; ISO 19453-6; DIN EN ISO 6270-2; DIN EN 60068-2-31; ISO 16750-5

VDA 233Name not checked yet
As written on the certificate · Line 6 (DAKKS D-PL-22860-01-01)

DIN EN ISO 105-B06:2020-12; ISO 14993:2018-07; ISO 16750-4:2023-07; ISO 16750-5:2023-07; VDA 233-102 2013-06; VDA 621-415 1982-02; ASTM B117-19 2019-12; ASTM G85-19 2019-12; SAE J2334 2016-04; VW 51500-1 2025-05

As written on the certificate · Line 10 (DAKKS D-PL-22860-01-01)

DIN EN IEC 60068-2-11; DIN EN ISO 9227, NSS; ASTM B117-19; DIN EN ISO 9227, AASS; ASTM G85-19; DIN EN IEC 60068-2-52; SAE J2334; VDA 233-102; VDA 621-415; DIN EN ISO 11997-1; DIN EN ISO 11997-3; ISO 14993; ISO 19453-6; DIN EN ISO 6270-2; DIN EN 60068-2-31; ISO 16750-5

VDA 621Name not checked yet
As written on the certificate · Line 6 (DAKKS D-PL-22860-01-01)

DIN EN ISO 105-B06:2020-12; ISO 14993:2018-07; ISO 16750-4:2023-07; ISO 16750-5:2023-07; VDA 233-102 2013-06; VDA 621-415 1982-02; ASTM B117-19 2019-12; ASTM G85-19 2019-12; SAE J2334 2016-04; VW 51500-1 2025-05

As written on the certificate · Line 10 (DAKKS D-PL-22860-01-01)

DIN EN IEC 60068-2-11; DIN EN ISO 9227, NSS; ASTM B117-19; DIN EN ISO 9227, AASS; ASTM G85-19; DIN EN IEC 60068-2-52; SAE J2334; VDA 233-102; VDA 621-415; DIN EN ISO 11997-1; DIN EN ISO 11997-3; ISO 14993; ISO 19453-6; DIN EN ISO 6270-2; DIN EN 60068-2-31; ISO 16750-5

Scope as published by DAKKS

12 lines
DAKKS

ISO/IEC 17025

Active

D-PL-22860-01-00

View scope
DAKKS

ISO/IEC 17025

Active

D-PL-22860-01-01

View scope

Location

Erwin-Seiz-Straße 9, Reutlingen, 72764, DE

48.48515, 9.22771

Open in Maps

Accreditation data refreshed from the DAKKS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.