Element Materials Technology Boulder
80 Health Park Drive, Ste 20, 80027, Louisville, CO, United States
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at Element Materials Technology Boulder?
Claim this profile to keep it accurate.
Register record
- A2LARefreshed
- 7207.01Active
Accredited standards
3Our reading of the A2LA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
ISO 80601-2-61Medical electrical equipment - Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipment
ISO 81060-1; ISO 81060-2; SOP N001; SOP Q001; SOP Q002; SOP Q003; SOP Q004; SOP Q008; SOP I001; SOP I002; SOP Q006; SOP S001; ISO 80601-2-61 Annex EE; ISO/IEC Guide 46; FDA – Applying Human Factors and Usability Engineering to Medical Devices / Guidance for Industry and Food and Drug Administration Staff – February 3, 2016
ISO 81060-1Non-invasive sphygmomanometers - Part 1: Requirements and test methods for non-automated measurement type
ISO 81060-1; ISO 81060-2; SOP N001; SOP Q001; SOP Q002; SOP Q003; SOP Q004; SOP Q008; SOP I001; SOP I002; SOP Q006; SOP S001; ISO 80601-2-61 Annex EE; ISO/IEC Guide 46; FDA – Applying Human Factors and Usability Engineering to Medical Devices / Guidance for Industry and Food and Drug Administration Staff – February 3, 2016
ISO 81060-2Non-invasive sphygmomanometers - Part 2: Clinical investigation of intermittent automated measurement type
ISO 81060-1; ISO 81060-2; SOP N001; SOP Q001; SOP Q002; SOP Q003; SOP Q004; SOP Q008; SOP I001; SOP I002; SOP Q006; SOP S001; ISO 80601-2-61 Annex EE; ISO/IEC Guide 46; FDA – Applying Human Factors and Usability Engineering to Medical Devices / Guidance for Industry and Food and Drug Administration Staff – February 3, 2016
Scope as published by A2LA
2 lines
ISO/IEC 17025
Active7207.01
The scope document we hold says it was valid until 2026-07-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.
Accredited scope, certificate 7207.01
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | electrical | ISO 81060-1; ISO 81060-2; SOP N001; SOP Q001; SOP Q002; SOP Q003; SOP Q004; SOP Q008; SOP I001; SOP I002; SOP Q006; SOP S001; ISO 80601-2-61 Annex EE; ISO/IEC Guide 46; FDA – Applying Human Factors and Usability Engineering to Medical Devices / Guidance for Industry and Food and Drug Administration Staff – February 3, 2016 | - | - |
| 2 | electrical | - | - | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.