Industrieanlagen- Betriebsgesellschaft mit beschränkter Haftung Prüflabor für Qualifikationstests des Raumfahrt-Testzentrums

Einsteinstraße 20, 85521, Ottobrunn, Germany

DAKKS|D-PL-12001-01-00ISO/IEC 17025Register refreshed 2026-09-25
Certificates
1
Scope items
25
Standards
29
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Industrieanlagen- Betriebsgesellschaft mit beschränkter Haftung Prüflabor für Qualifikationstests des Raumfahrt-Testzentrums?

Claim this profile to keep it accurate.

Register record

DAKKSRefreshed
D-PL-12001-01-00Active

Accredited standards

29

Our reading of the DAKKS scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

IEC 61000 series

IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
As written on the certificate · Line 16 (DAKKS D-PL-12001-01-00)

DIN EN 61000-4-5; VDE 0847-4-5:2015-03; IEC 61000-4-5:2014; EN 61000-4-5:2014; DIN EN 61000-4-6; VDE 0847-4-6:2014-08; IEC 61000-4-6:2013; EN 61000-4-6:2014; DIN EN 61000-4-8; VDE 0847-4-8:2010-11; IEC 61000-4-8:2009; EN 61000-4-8:2010; DIN EN 61000-4-11; 2005-02; VDE 0847-4-11:2005-02; IEC 61000-4-11:2004; EN 61000-4-11:2004; DIN EN 61000-3-2; VDE 0838-2:2015-03; IEC 61000-3-2:2014; EN 61000-3-2:2014

IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
As written on the certificate · Line 17 (DAKKS D-PL-12001-01-00)

DIN EN 61000 -3-3; VDE 0838-3:2014-03; IEC 61000-3-3:2013; DIN EN 61000 -3-11; VDE 0838-11:2001-04; IEC 61000-3-11:2000; DIN EN 61000 -3-12; VDE 0838-12:2012-06; IEC 61000-3-12:2011; DIN EN 55024:2011 -09; VDE 0878-24:2011-09; DIN EN 60068 -2-1; 2008-01; IEC 60068-2-1: 2007

IEC 61000-3-11Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current ≤ 75 A and subject to conditional connection
As written on the certificate · Line 17 (DAKKS D-PL-12001-01-00)

DIN EN 61000 -3-3; VDE 0838-3:2014-03; IEC 61000-3-3:2013; DIN EN 61000 -3-11; VDE 0838-11:2001-04; IEC 61000-3-11:2000; DIN EN 61000 -3-12; VDE 0838-12:2012-06; IEC 61000-3-12:2011; DIN EN 55024:2011 -09; VDE 0878-24:2011-09; DIN EN 60068 -2-1; 2008-01; IEC 60068-2-1: 2007

IEC 61000-3-12Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phaseCertificate says EN 61000-3-12. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 17 (DAKKS D-PL-12001-01-00)

DIN EN 61000 -3-3; VDE 0838-3:2014-03; IEC 61000-3-3:2013; DIN EN 61000 -3-11; VDE 0838-11:2001-04; IEC 61000-3-11:2000; DIN EN 61000 -3-12; VDE 0838-12:2012-06; IEC 61000-3-12:2011; DIN EN 55024:2011 -09; VDE 0878-24:2011-09; DIN EN 60068 -2-1; 2008-01; IEC 60068-2-1: 2007

IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
As written on the certificate · Line 15 (DAKKS D-PL-12001-01-00)

ECSS-E-ST-20-07C; DIN EN 61000-6-2; IEC 61000-6-2; DIN EN 61000-6-1; IEC 61000-6-1; DIN EN 61000-4-2; VDE 0847-4-2; IEC 61000-4-2; DIN EN 61000-4-3; VDE 0847-4-3; IEC 61000-4-3; DIN EN 61000-4-4; VDE 0847-4-4; IEC 61000-4-4

IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity testCertificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 15 (DAKKS D-PL-12001-01-00)

ECSS-E-ST-20-07C; DIN EN 61000-6-2; IEC 61000-6-2; DIN EN 61000-6-1; IEC 61000-6-1; DIN EN 61000-4-2; VDE 0847-4-2; IEC 61000-4-2; DIN EN 61000-4-3; VDE 0847-4-3; IEC 61000-4-3; DIN EN 61000-4-4; VDE 0847-4-4; IEC 61000-4-4

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
As written on the certificate · Line 15 (DAKKS D-PL-12001-01-00)

ECSS-E-ST-20-07C; DIN EN 61000-6-2; IEC 61000-6-2; DIN EN 61000-6-1; IEC 61000-6-1; DIN EN 61000-4-2; VDE 0847-4-2; IEC 61000-4-2; DIN EN 61000-4-3; VDE 0847-4-3; IEC 61000-4-3; DIN EN 61000-4-4; VDE 0847-4-4; IEC 61000-4-4

IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
As written on the certificate · Line 16 (DAKKS D-PL-12001-01-00)

DIN EN 61000-4-5; VDE 0847-4-5:2015-03; IEC 61000-4-5:2014; EN 61000-4-5:2014; DIN EN 61000-4-6; VDE 0847-4-6:2014-08; IEC 61000-4-6:2013; EN 61000-4-6:2014; DIN EN 61000-4-8; VDE 0847-4-8:2010-11; IEC 61000-4-8:2009; EN 61000-4-8:2010; DIN EN 61000-4-11; 2005-02; VDE 0847-4-11:2005-02; IEC 61000-4-11:2004; EN 61000-4-11:2004; DIN EN 61000-3-2; VDE 0838-2:2015-03; IEC 61000-3-2:2014; EN 61000-3-2:2014

IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
As written on the certificate · Line 16 (DAKKS D-PL-12001-01-00)

DIN EN 61000-4-5; VDE 0847-4-5:2015-03; IEC 61000-4-5:2014; EN 61000-4-5:2014; DIN EN 61000-4-6; VDE 0847-4-6:2014-08; IEC 61000-4-6:2013; EN 61000-4-6:2014; DIN EN 61000-4-8; VDE 0847-4-8:2010-11; IEC 61000-4-8:2009; EN 61000-4-8:2010; DIN EN 61000-4-11; 2005-02; VDE 0847-4-11:2005-02; IEC 61000-4-11:2004; EN 61000-4-11:2004; DIN EN 61000-3-2; VDE 0838-2:2015-03; IEC 61000-3-2:2014; EN 61000-3-2:2014

IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
As written on the certificate · Line 16 (DAKKS D-PL-12001-01-00)

DIN EN 61000-4-5; VDE 0847-4-5:2015-03; IEC 61000-4-5:2014; EN 61000-4-5:2014; DIN EN 61000-4-6; VDE 0847-4-6:2014-08; IEC 61000-4-6:2013; EN 61000-4-6:2014; DIN EN 61000-4-8; VDE 0847-4-8:2010-11; IEC 61000-4-8:2009; EN 61000-4-8:2010; DIN EN 61000-4-11; 2005-02; VDE 0847-4-11:2005-02; IEC 61000-4-11:2004; EN 61000-4-11:2004; DIN EN 61000-3-2; VDE 0838-2:2015-03; IEC 61000-3-2:2014; EN 61000-3-2:2014

IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
As written on the certificate · Line 16 (DAKKS D-PL-12001-01-00)

DIN EN 61000-4-5; VDE 0847-4-5:2015-03; IEC 61000-4-5:2014; EN 61000-4-5:2014; DIN EN 61000-4-6; VDE 0847-4-6:2014-08; IEC 61000-4-6:2013; EN 61000-4-6:2014; DIN EN 61000-4-8; VDE 0847-4-8:2010-11; IEC 61000-4-8:2009; EN 61000-4-8:2010; DIN EN 61000-4-11; 2005-02; VDE 0847-4-11:2005-02; IEC 61000-4-11:2004; EN 61000-4-11:2004; DIN EN 61000-3-2; VDE 0838-2:2015-03; IEC 61000-3-2:2014; EN 61000-3-2:2014

IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
As written on the certificate · Line 15 (DAKKS D-PL-12001-01-00)

ECSS-E-ST-20-07C; DIN EN 61000-6-2; IEC 61000-6-2; DIN EN 61000-6-1; IEC 61000-6-1; DIN EN 61000-4-2; VDE 0847-4-2; IEC 61000-4-2; DIN EN 61000-4-3; VDE 0847-4-3; IEC 61000-4-3; DIN EN 61000-4-4; VDE 0847-4-4; IEC 61000-4-4

IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
As written on the certificate · Line 15 (DAKKS D-PL-12001-01-00)

ECSS-E-ST-20-07C; DIN EN 61000-6-2; IEC 61000-6-2; DIN EN 61000-6-1; IEC 61000-6-1; DIN EN 61000-4-2; VDE 0847-4-2; IEC 61000-4-2; DIN EN 61000-4-3; VDE 0847-4-3; IEC 61000-4-3; DIN EN 61000-4-4; VDE 0847-4-4; IEC 61000-4-4

IEC 60068 series

IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
As written on the certificate · Line 17 (DAKKS D-PL-12001-01-00)

DIN EN 61000 -3-3; VDE 0838-3:2014-03; IEC 61000-3-3:2013; DIN EN 61000 -3-11; VDE 0838-11:2001-04; IEC 61000-3-11:2000; DIN EN 61000 -3-12; VDE 0838-12:2012-06; IEC 61000-3-12:2011; DIN EN 55024:2011 -09; VDE 0878-24:2011-09; DIN EN 60068 -2-1; 2008-01; IEC 60068-2-1: 2007

IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
As written on the certificate · Line 18 (DAKKS D-PL-12001-01-00)

DIN EN 60068-2-2; IEC 60068-2-2: 2007; DIN EN 60068-2-6; IEC 60068-2-6:2007; DIN EN 60068-2-7; IEC 60068-2-7: 1993; DIN EN 60068-2-14; IEC 60068-2-14:2009; DIN EN 60068-2-27; IEC 60068-2-27:2009; DIN EN 60068-2-31; IEC 60068-2-31:2008; DIN EN 60068-2-53; IEC 60068-2-53:2010; DIN EN 60068-2-64; IEC 60068-2-64:2008; DIN EN 60068-2-80; IEC 60068-2-80:2005; DIN EN 60068-2-81; IEC 60068-2-81: 2003

IEC 60068-2-6Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
As written on the certificate · Line 18 (DAKKS D-PL-12001-01-00)

DIN EN 60068-2-2; IEC 60068-2-2: 2007; DIN EN 60068-2-6; IEC 60068-2-6:2007; DIN EN 60068-2-7; IEC 60068-2-7: 1993; DIN EN 60068-2-14; IEC 60068-2-14:2009; DIN EN 60068-2-27; IEC 60068-2-27:2009; DIN EN 60068-2-31; IEC 60068-2-31:2008; DIN EN 60068-2-53; IEC 60068-2-53:2010; DIN EN 60068-2-64; IEC 60068-2-64:2008; DIN EN 60068-2-80; IEC 60068-2-80:2005; DIN EN 60068-2-81; IEC 60068-2-81: 2003

IEC 60068-2-7Name not checked yet
As written on the certificate · Line 18 (DAKKS D-PL-12001-01-00)

DIN EN 60068-2-2; IEC 60068-2-2: 2007; DIN EN 60068-2-6; IEC 60068-2-6:2007; DIN EN 60068-2-7; IEC 60068-2-7: 1993; DIN EN 60068-2-14; IEC 60068-2-14:2009; DIN EN 60068-2-27; IEC 60068-2-27:2009; DIN EN 60068-2-31; IEC 60068-2-31:2008; DIN EN 60068-2-53; IEC 60068-2-53:2010; DIN EN 60068-2-64; IEC 60068-2-64:2008; DIN EN 60068-2-80; IEC 60068-2-80:2005; DIN EN 60068-2-81; IEC 60068-2-81: 2003

IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
As written on the certificate · Line 18 (DAKKS D-PL-12001-01-00)

DIN EN 60068-2-2; IEC 60068-2-2: 2007; DIN EN 60068-2-6; IEC 60068-2-6:2007; DIN EN 60068-2-7; IEC 60068-2-7: 1993; DIN EN 60068-2-14; IEC 60068-2-14:2009; DIN EN 60068-2-27; IEC 60068-2-27:2009; DIN EN 60068-2-31; IEC 60068-2-31:2008; DIN EN 60068-2-53; IEC 60068-2-53:2010; DIN EN 60068-2-64; IEC 60068-2-64:2008; DIN EN 60068-2-80; IEC 60068-2-80:2005; DIN EN 60068-2-81; IEC 60068-2-81: 2003

IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
As written on the certificate · Line 18 (DAKKS D-PL-12001-01-00)

DIN EN 60068-2-2; IEC 60068-2-2: 2007; DIN EN 60068-2-6; IEC 60068-2-6:2007; DIN EN 60068-2-7; IEC 60068-2-7: 1993; DIN EN 60068-2-14; IEC 60068-2-14:2009; DIN EN 60068-2-27; IEC 60068-2-27:2009; DIN EN 60068-2-31; IEC 60068-2-31:2008; DIN EN 60068-2-53; IEC 60068-2-53:2010; DIN EN 60068-2-64; IEC 60068-2-64:2008; DIN EN 60068-2-80; IEC 60068-2-80:2005; DIN EN 60068-2-81; IEC 60068-2-81: 2003

IEC 60068-2-31Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens
As written on the certificate · Line 18 (DAKKS D-PL-12001-01-00)

DIN EN 60068-2-2; IEC 60068-2-2: 2007; DIN EN 60068-2-6; IEC 60068-2-6:2007; DIN EN 60068-2-7; IEC 60068-2-7: 1993; DIN EN 60068-2-14; IEC 60068-2-14:2009; DIN EN 60068-2-27; IEC 60068-2-27:2009; DIN EN 60068-2-31; IEC 60068-2-31:2008; DIN EN 60068-2-53; IEC 60068-2-53:2010; DIN EN 60068-2-64; IEC 60068-2-64:2008; DIN EN 60068-2-80; IEC 60068-2-80:2005; DIN EN 60068-2-81; IEC 60068-2-81: 2003

IEC 60068-2-53Name not checked yet
As written on the certificate · Line 18 (DAKKS D-PL-12001-01-00)

DIN EN 60068-2-2; IEC 60068-2-2: 2007; DIN EN 60068-2-6; IEC 60068-2-6:2007; DIN EN 60068-2-7; IEC 60068-2-7: 1993; DIN EN 60068-2-14; IEC 60068-2-14:2009; DIN EN 60068-2-27; IEC 60068-2-27:2009; DIN EN 60068-2-31; IEC 60068-2-31:2008; DIN EN 60068-2-53; IEC 60068-2-53:2010; DIN EN 60068-2-64; IEC 60068-2-64:2008; DIN EN 60068-2-80; IEC 60068-2-80:2005; DIN EN 60068-2-81; IEC 60068-2-81: 2003

IEC 60068-2-64Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidanceCertificate says EN 60068-2-64. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 18 (DAKKS D-PL-12001-01-00)

DIN EN 60068-2-2; IEC 60068-2-2: 2007; DIN EN 60068-2-6; IEC 60068-2-6:2007; DIN EN 60068-2-7; IEC 60068-2-7: 1993; DIN EN 60068-2-14; IEC 60068-2-14:2009; DIN EN 60068-2-27; IEC 60068-2-27:2009; DIN EN 60068-2-31; IEC 60068-2-31:2008; DIN EN 60068-2-53; IEC 60068-2-53:2010; DIN EN 60068-2-64; IEC 60068-2-64:2008; DIN EN 60068-2-80; IEC 60068-2-80:2005; DIN EN 60068-2-81; IEC 60068-2-81: 2003

IEC 60068-2-80Environmental testing - Part 2-80: Tests - Test Fi: Vibration - Mixed mode
As written on the certificate · Line 18 (DAKKS D-PL-12001-01-00)

DIN EN 60068-2-2; IEC 60068-2-2: 2007; DIN EN 60068-2-6; IEC 60068-2-6:2007; DIN EN 60068-2-7; IEC 60068-2-7: 1993; DIN EN 60068-2-14; IEC 60068-2-14:2009; DIN EN 60068-2-27; IEC 60068-2-27:2009; DIN EN 60068-2-31; IEC 60068-2-31:2008; DIN EN 60068-2-53; IEC 60068-2-53:2010; DIN EN 60068-2-64; IEC 60068-2-64:2008; DIN EN 60068-2-80; IEC 60068-2-80:2005; DIN EN 60068-2-81; IEC 60068-2-81: 2003

IEC 60068-2-81Name not checked yet
As written on the certificate · Line 18 (DAKKS D-PL-12001-01-00)

DIN EN 60068-2-2; IEC 60068-2-2: 2007; DIN EN 60068-2-6; IEC 60068-2-6:2007; DIN EN 60068-2-7; IEC 60068-2-7: 1993; DIN EN 60068-2-14; IEC 60068-2-14:2009; DIN EN 60068-2-27; IEC 60068-2-27:2009; DIN EN 60068-2-31; IEC 60068-2-31:2008; DIN EN 60068-2-53; IEC 60068-2-53:2010; DIN EN 60068-2-64; IEC 60068-2-64:2008; DIN EN 60068-2-80; IEC 60068-2-80:2005; DIN EN 60068-2-81; IEC 60068-2-81: 2003

Other standards

CISPR 24Information technology equipment - Immunity characteristics - Limits and methods of measurementCertificate says EN 55024. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 17 (DAKKS D-PL-12001-01-00)

DIN EN 61000 -3-3; VDE 0838-3:2014-03; IEC 61000-3-3:2013; DIN EN 61000 -3-11; VDE 0838-11:2001-04; IEC 61000-3-11:2000; DIN EN 61000 -3-12; VDE 0838-12:2012-06; IEC 61000-3-12:2011; DIN EN 55024:2011 -09; VDE 0878-24:2011-09; DIN EN 60068 -2-1; 2008-01; IEC 60068-2-1: 2007

EN 2282Name not checked yet
As written on the certificate · Line 9 (DAKKS D-PL-12001-01-00)

SPX 902 A0002 E01; D6 -16050 -4; D6 -16050 -5; IATA Dangerous Goods Regulation 55. Issue; DIN EN 2282; ABD0100.1.8C; ABD0100.1.8D; ABD0100.1.8E; ABD0100.1.8.1B

IEC 61373Railway applications - Rolling stock equipment - Shock and vibration tests
As written on the certificate · Line 19 (DAKKS D-PL-12001-01-00)

DIN EN 61373; ISO 16750-3; GL 2012; ABS Part 4; RTCA/DO-160D; RTCA/DO-160E; RTCA/DO-160F; RTCA/DO-160G

ISO 2669Environmental tests for aircraft equipment - Steady-state acceleration
As written on the certificate · Line 20 (DAKKS D-PL-12001-01-00)

RTCA/DO-160E; RTCA/DO-160F; RTCA/DO-160G; ABD0100.1.2; SPX 902 A 0002 E01; ISO 2669; AECTP 400

ISO 16750-3Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 3: Mechanical loads
As written on the certificate · Line 19 (DAKKS D-PL-12001-01-00)

DIN EN 61373; ISO 16750-3; GL 2012; ABS Part 4; RTCA/DO-160D; RTCA/DO-160E; RTCA/DO-160F; RTCA/DO-160G

Scope as published by DAKKS

25 lines
DAKKS

ISO/IEC 17025

Active

D-PL-12001-01-00

View scope

Location

Einsteinstraße 20, Ottobrunn, 85521, DE

48.05148, 11.65978

Open in Maps

Accreditation data refreshed from the DAKKS register on .