CHEMICA LAB S.R.L.
Via A. De Gasperi, 38, 20020, Villa Cortese, Italy
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at CHEMICA LAB S.R.L.?
Claim this profile to keep it accurate.
Register record
- ACCREDIARefreshed
- 00834Active
Certificates and scope
1ISO/IEC 17025
Active00834
Accredited scope, certificate 00834
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | chemical | APAT CNR IRSA 2060 Man 29 2003; APAT CNR IRSA 2030 Man 29 2003; APAT CNR IRSA 4050 Man 29 2003; MU 956:01; APAT CNR IRSA 2110 Man 29 2003; UNI EN ISO 7393-2:2018; UNI EN ISO 9308-1:2017; UNI EN ISO 7899-2:2003; UNI EN ISO 16266:2008; ISO 11731:2017; UNI ISO 23695:2023 | Waste water | - |
| 2 | chemical | UNI ISO 23697-1:2023; EPA 5021A 2014; EPA 8260D 2018; ISO 15705:2002; APAT CNR IRSA 2090 C Man 29 2003; UNI EN ISO 15587-2:2002; UNI EN ISO 11885:2009; UNI EN ISO 7932:2020; UNI EN ISO 15213-2:2024; ISO 21571:2005/Amd 1:2013 + ISO/TS 20224-3:2020; UNI EN ISO 4833-2:2022; AFNOR 3M 01/09-04/03 A; MICROVAL 2017LR76; AFNOR 3M 01/06-09/97; AFNOR 3M 01/13-07/14; AFNOR UNI 03/04-04/05; AFNOR 3M 01/01-09/89; AFNOR UNI 03/06-12/07; UNI EN 12457-2:2004; UNI EN ISO 10304-1:2009; UNI EN 27888:1995; UNI EN ISO 10523:2012 | Waste water | 10 to 500 µg/L |
| 3 | chemical | ISO 14698-1:2003; UNI EN 14346:2007; CNR IRSA 1 Q 64 Vol 3 1985; APAT CNR IRSA 2060 Man 29 2003; ICRAM Metodologie analitiche di riferimento - sedimenti (2001); UNI EN ISO 11885:2009; EPA 5021A 2014; EPA 8260D 2018; UNI EN 17503:2022; UNI EN 15934:2012; DM 13/09/1999; EPA 3051A 2007; EPA 6010D 2018 | Soil | - |
| 4 | chemical | UNI CEI EN ISO/IEC 17025:2018; APAT CNR IRSA 1030 Man 29 2003; APAT CNR IRSA 6010 Man 29 2003; ISO 14698-1:2003; DM 13/09/1999 SO n 185 GU n 248 21/10/1999 Met I.1; ISO 18593:2018 | Waste water | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Italy
- EUROFINS ENVIRON-LABCORTEOLONA E GENZONE · ~58 kmACCREDIAShares 4 accredited methods and materialsAPAT CNR IRSA 1030 Man 29 2003UNI ISO 23697-1:2023Soil
- LAB 2000Nonantola · ~196 kmACCREDIAShares 4 accredited methods and materialsAPAT CNR IRSA 1030 Man 29 2003APAT CNR IRSA 2060 Man 29 2003Soil
- BIOCHEMIE LAB S.r.l.Campi Bisenzio · ~263 kmACCREDIAShares 4 accredited methods and materialsAPAT CNR IRSA 1030 Man 29 2003APAT CNR IRSA 2060 Man 29 2003Soil
- HYDROLABFerrandina · ~833 kmACCREDIAShares 4 accredited methods and materialsAPAT CNR IRSA 1030 Man 29 2003APAT CNR IRSA 2060 Man 29 2003Soil
- LABSEL S.R.L.Lequile · ~953 kmACCREDIAShares 4 accredited methods and materialsAPAT CNR IRSA 1030 Man 29 2003APAT CNR IRSA 2060 Man 29 2003Soil
Accreditation data refreshed from the ACCREDIA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.