MDR Laboratories Private
444, Gokulam Street, Mathur, Chennai, 600068, India, Chennai, India
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at MDR Laboratories Private?
Claim this profile to keep it accurate.
Register record
- A2LARefreshed
- 7649.01Active
Accredited standards
We have not yet extracted the standard numbers from this lab’s scope document. The scope text we hold is below.
Scope as published by A2LA
3 lines
ISO/IEC 17025
Active7649.01
The scope document we hold says it is valid until 2028-03-31.
Accredited scope, certificate 7649.01
This scope has not been split into individual lines yet. Below is the text of the scope document as published.
Part 1 of 3
(A2LA Cert. No. 7649.01) 04/07/2026 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 MDR LABORATORIES PRIVATE LIMITED 444 Gokulam Street Mathur Chennai, INDIA 600068 Parthiban Natarajan Phone: +91-9840875072 BIOLOGICAL Valid To: March 31, 2028 Certificate Number: 7649.01 In recognition of the successful completion of the A2LA evaluation process , (including an assessment of the organization’s compliance with A2LA’s R256 Specific Requirements and with U.S. FDA Good Laboratory Practice (GLP) Regulations per 21 CFR Part 58 1), accreditation is granted to this laboratory to perform the following tests on medical devices: FDA Recognition Number Test Name Standard Method 2-245 MEM Elution Cytotoxicity ISO 10993-5: Third Edition 2009-06-01, Biological Evaluation of Medical Devices -Part 5: Tests for In Vitro Cytotoxicity. 2-248; 2-250 Direct and Indirect Hemolysis ISO 10993-4: Third Edition 2017-04, Biological Evaluation of Medical Devices - Part 4: Selection of Tests for Interactions with Blood. ASTM F756-17: Standard Practice for Assessment of Hemolytic Properties of Materials. 2-296; 2-256 Guinea Pig Maximization Sensitization ISO 10993-10 Fourth Edition 2021-11 Biological Evaluation of Medical Devices - Part 10: Tests for skin sensitization. ASTM F720-17: Standard Practice for Testing Guinea Pigs for Contact Allergens: Guinea Pig Maximization Test. 2-291 Intracutaneous Reactivity Irritation Dermal Irritation ISO 10993-23 First Edition 2021-01. Biological Evaluation of Medical Devices - Part 23: Tests for Irritation. 2-255 Acute Systemic Toxicity ISO 10993-11: Third Edition 2017-09, Biological Evaluation of Medical Devices - Part 11: Tests for Systemic Toxicity. 2-289 Sample preparation for all test types ISO 10993-12: Fifth Edition 2021-01, Biological Evaluation of Medical Devices - Part 12: Sample Preparation and Reference Materials. 1Assessment to the U.S. FDA GLP (Good Laboratory Practice) Regulations 21CFR58 does not imply acceptance by the FDA.
Part 2 of 3
(A2LA Cert. No. 7649.01) 04/07/2026 Page 2 of 2 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following tests on medical devices in conformance with applicable U.S. FDA Good Laboratory Practice (GLP) Code of Federal Regulations Title 21-part 58 (21CFR58)1 requirements. Test Name Standard Method1 Tests for local effects after implantation ISO 10993-6: Third Edition 2016-12-01, Biological evaluation of medical devices - Part 6: Tests for local effects after implantation Tests for genotoxicity ISO 10993-3: Third Edition 2014-10-01, Biological evaluation of medical devices - Part 3: Tests for genotoxicity, carcinogenicity and reproductive toxicity CHEMICAL In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following tests on m edical devices, in conformance with applicable U.S. FDA Good Laboratory Practice (GLP) Code of Federal Regulations Title 21-part 58 (21CFR58)1 requirements. Test Name Standard Method1 Extraction ISO 10993-12: Fifth Edition 2021-01, Biological Evaluation of Medical Devices - Part 12: Sample Preparation and Reference Materials. Elemental Scan by Inductively Coupled Plasma / Mass Spectrometry (ICP/AES) ISO 10993-18: Fourth Edition 2020-01, Biological evaluation of medical devices — Part 18: Chemical characterization of medical device materials within a risk management process. Screening of Residual Solvent (VOC) Headspace by Gas Chromatography / Mass Spectrometry (HSGC/MS) ISO 10993-18: Fourth Edition 2020-01, Biological evaluation of medical devices — Part 18: Chemical characterization of medical device materials within a risk management process. Screening of Non-Volatile Compounds by Ultra Performance Liquid Chromatography / Mass Spectrometry (UPLC/MS) ISO 10993-18: Fourth Edition 2020-01, Biological evaluation of medical devices — Part 18: Chemical characterization of medical device materials within a risk management process. Screening of Semi-Volatile and Volatile Compounds by Direction Injection Gas Chromatography / Mass Spectrometry (GC/MS) ISO 10993-18: Fourth Edition 2020-01, Biological evaluation of medical devices — Part 18: Chemical characterization of medical device materials within a risk management process. 1Assessment to the U.S. FDA GLP (Good Laboratory Practice) Regulations 21CFR58 does not imply acceptance by the FDA.
Part 3 of 3
For the tests to which this accreditation applies, please refer to the laboratory’s Biological Scope of Accreditation. Accredited Laboratory A2LA has accredited MDR LABORATORIES PRIVATE LIMITED Chennai, INDIA for technical competence in the field of Biological Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This laboratory also meets the A2LA R256- Specific Requirements. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 7th day of April 2026. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 7649.01 Valid to March 31, 2028
Text extracted from the accredited scope document. Layout and tables from the original may not carry over; the scope document itself is the authoritative copy.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.