BIOTECNAL
C/ Cabrera, 9 - 11. Pol. Ind. Sudoeste, 08192, Sant Quirze del Valles, Spain
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at BIOTECNAL?
Claim this profile to keep it accurate.
Register record
- ENACRefreshed
- 408/LE2123Active
- 408/LE582Active
Accredited standards
16Our reading of the ENAC scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
ISO
ISO 4833-1Microbiology of the food chain - Horizontal method for the enumeration of microorganisms - Part 1: Colony count at 30 °C by the pour plate technique
PNT 4/07/005; PNT 4/07/002; PNT 4/08/003/A; PNT 4/12/004/A; PNT 4/20/004/A; PNT 1/01/001; UNE-EN ISO 4833-1; PNT 1/05/010; ISO 16649-2; PNT 1/12/014; UNE-EN ISO 11290-2; PNT 1/12/003; UNE-EN ISO 11290-1
ISO 6222Water quality - Enumeration of culturable micro-organisms - Colony count by inoculation in a nutrient agar culture medium
PNT 1/19/001; Rapid´Campylobacter Agar; PNT 1/12/015/AE. Rev. 06; PNT 1/12/015/L. Rev. 03; PNT 1/06/002; UNE EN ISO 11290-1; UNE-EN ISO 6222; UNE-EN ISO 9308-1; UNE-EN ISO 7899-2
ISO 7027-1Water quality - Determination of turbidity - Part 1: Quantitative methods
UNE-EN ISO 7027-1; UNE-EN 26777; Standard Methods 4500 -NH3 Nitrogen (Ammonia); ASTM D1252 Método A; UNE-EN 872
ISO 7899-2Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
PNT 1/19/001; Rapid´Campylobacter Agar; PNT 1/12/015/AE. Rev. 06; PNT 1/12/015/L. Rev. 03; PNT 1/06/002; UNE EN ISO 11290-1; UNE-EN ISO 6222; UNE-EN ISO 9308-1; UNE-EN ISO 7899-2
ISO 9308-1Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 1: Membrane filtration method for waters with low bacterial background flora
PNT 1/19/001; Rapid´Campylobacter Agar; PNT 1/12/015/AE. Rev. 06; PNT 1/12/015/L. Rev. 03; PNT 1/06/002; UNE EN ISO 11290-1; UNE-EN ISO 6222; UNE-EN ISO 9308-1; UNE-EN ISO 7899-2
ISO 10523Water quality - Determination of pH
PNT 2/19/018 Rev. 22; PNT 2/19/017 Rev. 25; PNT 2/16/013; UNE-EN ISO 10523; PNT 4/16/003; PNT 2/03/016; UNE-EN 27888; PNT 4/03/008; PNT 4/19/001; PNT 2/16/030 Rev. 17; PNT 2/16/037 Rev. 7
ISO 11290-1Microbiology of the food chain - Horizontal method for the detection and enumeration of Listeria monocytogenes and of Listeria spp. - Part 1: Detection method
PNT 4/07/005; PNT 4/07/002; PNT 4/08/003/A; PNT 4/12/004/A; PNT 4/20/004/A; PNT 1/01/001; UNE-EN ISO 4833-1; PNT 1/05/010; ISO 16649-2; PNT 1/12/014; UNE-EN ISO 11290-2; PNT 1/12/003; UNE-EN ISO 11290-1
PNT 1/19/001; Rapid´Campylobacter Agar; PNT 1/12/015/AE. Rev. 06; PNT 1/12/015/L. Rev. 03; PNT 1/06/002; UNE EN ISO 11290-1; UNE-EN ISO 6222; UNE-EN ISO 9308-1; UNE-EN ISO 7899-2
ISO 11290-2Microbiology of the food chain - Horizontal method for the detection and enumeration of Listeria monocytogenes and of Listeria spp. - Part 2: Enumeration method
PNT 4/07/005; PNT 4/07/002; PNT 4/08/003/A; PNT 4/12/004/A; PNT 4/20/004/A; PNT 1/01/001; UNE-EN ISO 4833-1; PNT 1/05/010; ISO 16649-2; PNT 1/12/014; UNE-EN ISO 11290-2; PNT 1/12/003; UNE-EN ISO 11290-1
ISO 11731Water quality - Enumeration of LegionellaCertificate says EN ISO 11731 2019-03 UBA Empfehlung 18. Probably the same standard; not checked against the EN document.
UNE-EN ISO 11731; PNT 1/12/006
ISO 11737-1Sterilization of health care products - Microbiological methods - Part 1: Determination of a population of microorganisms on products
UNE-EN ISO 11737-1; UNE-EN ISO 11737-2
ISO 11737-2Sterilization of health care products - Microbiological methods - Part 2: Tests of sterility performed in the definition, validation and maintenance of a sterilization process
UNE-EN ISO 11737-1; UNE-EN ISO 11737-2
ISO 16649-2Microbiology of food and animal feeding stuffs - Horizontal method for the enumeration of beta-glucuronidase-positive Escherichia coli - Part 2: Colony-count technique at 44 degrees C using 5-bromo-4-chloro-3-indolyl beta-D-glucuronide
PNT 4/07/005; PNT 4/07/002; PNT 4/08/003/A; PNT 4/12/004/A; PNT 4/20/004/A; PNT 1/01/001; UNE-EN ISO 4833-1; PNT 1/05/010; ISO 16649-2; PNT 1/12/014; UNE-EN ISO 11290-2; PNT 1/12/003; UNE-EN ISO 11290-1
EN
EN 872Water quality - Determination of suspended solids - Method by filtration through glass fibre filters
UNE-EN ISO 7027-1; UNE-EN 26777; Standard Methods 4500 -NH3 Nitrogen (Ammonia); ASTM D1252 Método A; UNE-EN 872
EN 26777Water quality - Determination of nitrite - Molecular absorption spectrometric method
UNE-EN ISO 7027-1; UNE-EN 26777; Standard Methods 4500 -NH3 Nitrogen (Ammonia); ASTM D1252 Método A; UNE-EN 872
EN 27888Water quality - Determination of electrical conductivity
PNT 2/19/018 Rev. 22; PNT 2/19/017 Rev. 25; PNT 2/16/013; UNE-EN ISO 10523; PNT 4/16/003; PNT 2/03/016; UNE-EN 27888; PNT 4/03/008; PNT 4/19/001; PNT 2/16/030 Rev. 17; PNT 2/16/037 Rev. 7
Other standards
ASTM D1252Name not checked yet
UNE-EN ISO 7027-1; UNE-EN 26777; Standard Methods 4500 -NH3 Nitrogen (Ammonia); ASTM D1252 Método A; UNE-EN 872
Scope as published by ENAC
8 lines
ISO/IEC 17025
Active408/LE2123
Accredited scope, certificate 408/LE2123
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | biological | UNE-EN ISO 11737-1; UNE-EN ISO 11737-2 | Productos sanitarios | 0.5 to mg/100 g |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
Active408/LE582
Accredited scope, certificate 408/LE582
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | food | UNE-EN ISO/IEC 17025:2017; PNT 2/08/003 Rev. 34; PNT 2/07/002 Rev. 35; PNT 2/16/006 Rev. 28; PNT 2/03/008 Rev. 22; PNT 2/03/011; Orden 31-7-79 (BOE 29-08-79) | Alimentos (excepto derivados, Leche, productos lácteos y helados, Almidones, y féculas, Miel); Pescado y productos de la pesca; Carnes y productos cárnicos | - |
| 2 | chemical | PNT 2/19/018 Rev. 22; PNT 2/19/017 Rev. 25; PNT 2/16/013; UNE-EN ISO 10523; PNT 4/16/003; PNT 2/03/016; UNE-EN 27888; PNT 4/03/008; PNT 4/19/001; PNT 2/16/030 Rev. 17; PNT 2/16/037 Rev. 7 | Jamón curado; Aguas de consumo; Aguas envasadas; Aguas residuales; Alimentos; Detergentes y productos de limpieza, champú y gel de baño | - |
| 3 | environmental | UNE-EN ISO 7027-1; UNE-EN 26777; Standard Methods 4500 -NH3 Nitrogen (Ammonia); ASTM D1252 Método A; UNE-EN 872 | Aguas de consumo; Aguas envasadas; Aguas residuales | 1 to UNF |
| 4 | food | PNT 4/07/005; PNT 4/07/002; PNT 4/08/003/A; PNT 4/12/004/A; PNT 4/20/004/A; PNT 1/01/001; UNE-EN ISO 4833-1; PNT 1/05/010; ISO 16649-2; PNT 1/12/014; UNE-EN ISO 11290-2; PNT 1/12/003; UNE-EN ISO 11290-1 | Alimentos y aditivos alimentarios; Alimentos; Piensos | See scope document |
| 5 | biological | PNT 1/19/001; Rapid´Campylobacter Agar; PNT 1/12/015/AE. Rev. 06; PNT 1/12/015/L. Rev. 03; PNT 1/06/002; UNE EN ISO 11290-1; UNE-EN ISO 6222; UNE-EN ISO 9308-1; UNE-EN ISO 7899-2 | Alimentos; Piensos; Laminocultivos; Hisopos y esponjas; Aguas de consumo; Aguas envasadas | - |
| 6 | biological | UNE-EN ISO 11731; PNT 1/12/006 | Aguas de consumo; Aguas continentales tratadas: piscina, spa, torre de refrigeración, condensador evaporativo, diálisis, uso farmacéutico o dental, riego urbano (parques o campos deportivos), baldeo de calles, vehículo de limpieza viaria, lavado industrial de vehículos, procesos industriales); Aguas continentales no tratadas: superficial, río, lago, embalse, subterránea, captación, costera, transición, sistemas contra incendios, riego agrícola | - |
| 7 | food | PNT 15/19/001 Rev. 6; Método interno | Jamón curado | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
C/ Cabrera, 9 - 11. Pol. Ind. Sudoeste, Sant Quirze del Valles, 08192, ES
41.53318, 2.08065
Open in MapsLabs with overlapping accredited scope in Spain
- EUROFINS CIDESAL, S.L. (Unipersonal)Palma · ~224 kmENACShares 1 accredited test methodISO 16649-2
- EUROFINS AMBIENTALYSPaterna · ~310 kmENACShares 1 accredited test methodISO 16649-2
- EUROFINS ECOSUR, S.A. (Unipersonal)Lorquí · ~478 kmENACShares 1 accredited test methodISO 16649-2
- ALS LIFE SCIENCES GALICIASantiago de Compostela · ~886 kmENACShares 1 accredited test methodISO 16649-2
- EUROFINS ANALISIS ALIMENTARIO SUROESTEHuelva · ~909 kmENACShares 1 accredited test methodISO 16649-2
Accreditation data refreshed from the ENAC register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ENAC entry linked above.