FindTestingLabs
Registers refreshed 2026-10-18.See refresh dates
United States

Aalberts IPSA

1418 S. Pearl Street, 29728, Pageland, SC, United States

A2LA|1736.01ISO/IEC 17025Register refreshed 2026-10-09
Certificates
1
Scope items
4
Standards
0
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Aalberts IPSA?

Claim this profile to keep it accurate.

Register record

A2LARefreshed
1736.01Active

Accredited standards

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Scope as published by A2LA

4 lines
A2LA

ISO/IEC 17025

Active

1736.01

The scope document we hold says it is valid until 2027-03-31.

View scope

Accredited scope, certificate 1736.01

LineDisciplineMethodMatrixRange
1Dimensional MetrologyISO/IEC 17025:2017 AND ANSI/NCSL Z540-1-1994; IEC 17025; ANSI/NCSL Z540-1-1994-to 10 in
2Dimensional Metrologyison Calipers Up to 20-to 30 in
3Dimensional Metrology
(A2LA Cert. No. 1736.01) 4/2/2025 Page 3 of 3 Parameter/Equipment Range CMC2, 3 (±) Comments Indicators Up to 4 in 0.60R Universal measuring machine II. Mechanical Parameter/Equipment Range CMC2 (±) Comments Torque Wrenches & Torque Multipliers (0.5 to 400) ozf·in (4 to 1000) lbf·in (20 to 250) lbf·ft (100 to 1100) lbf·ft 2.8 ozf·in 2.9 lbf·in 2.4 lbf·ft 4.1 lbf·ft CDI torque tester Pressure Gages Up to 300 psig Up to 10 000 psig Up to 15 000 psig Up to 3000 psig Up to 3000 psig Up to 10 000 psig Up to 15 000 psig 0.1 psig 2.5 psig 3.9 psig 0.6 psig 1.2 psig 2.9 psig 7.1 psig Crystal digital test gage Pace 5000 Comparator ____________________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or n early ideal measuring equipment. CMC’s represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches, D is the numerical value of the diameter of the device measured in inches, and R is the numerical value of the resolution of the device. 4 This scope meets A2LA’s P112 Flexible Scope Policy.
4Dimensional MetrologyISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025; ANSI/NCSL Z540-1-1994 and R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

1418 S. Pearl Street, Pageland, SC, 29728, US

34.75209, -80.39246

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.