Cleveland Cable Company

Riverside Park Road, Middlesbrough, TS2 1QW, Cleveland, United Kingdom

UKAS|31196ISO/IEC 17025Register refreshed 2026-09-25
Certificates
1
Scope items
2
Standards
5
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Cleveland Cable Company?

Claim this profile to keep it accurate.

Register record

UKASRefreshed
31196Active

Accredited standards

5

Our reading of the UKAS scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

IEC 60228Name not checked yet
As written on the certificate · Line 2 (UKAS 31196)

BS EN 60811-201:2012 +A1:2017; BS EN 60811-202:2012+A1:2017; BS EN 60811-203:2012; BS EN 60228:2024; BS EN 60811-501:2012+A1:2018

IEC 60811-201Name not checked yet
As written on the certificate · Line 2 (UKAS 31196)

BS EN 60811-201:2012 +A1:2017; BS EN 60811-202:2012+A1:2017; BS EN 60811-203:2012; BS EN 60228:2024; BS EN 60811-501:2012+A1:2018

IEC 60811-202Name not checked yet
As written on the certificate · Line 2 (UKAS 31196)

BS EN 60811-201:2012 +A1:2017; BS EN 60811-202:2012+A1:2017; BS EN 60811-203:2012; BS EN 60228:2024; BS EN 60811-501:2012+A1:2018

IEC 60811-203Name not checked yet
As written on the certificate · Line 2 (UKAS 31196)

BS EN 60811-201:2012 +A1:2017; BS EN 60811-202:2012+A1:2017; BS EN 60811-203:2012; BS EN 60228:2024; BS EN 60811-501:2012+A1:2018

IEC 60811-501Electric and optical fibre cables - Test methods for non-metallic materials - Part 501: Mechanical tests - Tests for determining the mechanical properties of insulating and sheathing compounds
As written on the certificate · Line 2 (UKAS 31196)

BS EN 60811-201:2012 +A1:2017; BS EN 60811-202:2012+A1:2017; BS EN 60811-203:2012; BS EN 60228:2024; BS EN 60811-501:2012+A1:2018

Scope as published by UKAS

2 lines
UKAS

ISO/IEC 17025

Active

31196

View scope

Accredited scope, certificate 31196

LineDisciplineMethodMatrixRange
1-
Assessment Manager: DH1 Page 1 of 2 Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 31196 Accredited to ISO/IEC 17025:2017 Cleveland Cable Company Limited Issue No: 001 Issue date: 02 April 2026 Riverside Park Road Middlesbrough Cleveland TS2 1QW Contact: Jason Hodgkinson Tel: +44 (0) 1642 757 300 E-Mail: jhodgkinson@clevelandcable.com Website: https://www.clevelandcable.com/ Location where testing activities covered by the above accreditation are undertaken 10B Mickleton Road Middlesbrough Cleveland TS2 1RQ
2materialsBS EN 60811-201:2012 +A1:2017; BS EN 60811-202:2012+A1:2017; BS EN 60811-203:2012; BS EN 60228:2024; BS EN 60811-501:2012+A1:2018ELECTRIC CABLES-

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Riverside Park Road, Middlesbrough, Cleveland, TS2 1QW, GB

54.59567, -1.20725

Open in Maps

Accreditation data refreshed from the UKAS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the UKAS entry linked above.