BALANCE METROLOGIA S.A.S ZOMAC
KM 1 VIA PEREIRA BG 200 VDA CAUYA, Anserma Caldas, Colombia, Anserma Caldas, Colombia
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at BALANCE METROLOGIA S.A.S ZOMAC?
Claim this profile to keep it accurate.
Register record
- A2LARefreshed
- 7604.01Active
Accredited standards
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Scope as published by A2LA
7 lines
ISO/IEC 17025
Active7604.01
The scope document we hold says it is valid until 2027-09-30.
Accredited scope, certificate 7604.01
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | Dimensional Metrology | ISO/IEC 17025:2017 | - | See scope document |
| 2 | Dimensional Metrology | - | - | to 150 mm |
| 3 | Dimensional Metrology | - | - | to 610 mm |
| 4 | Chemical Testing | (A2LA Cert. No. 7604.01) Revised 10/03/2025 Page 4 of 6
Parameter/Equipment
Range
CMC2 (±)
Comments
Force3– Roller Brake
Testers
Up to 3000 N
Up to 6000 N
Up to 30 000 N
0.0054 x F + 4.7 N
0.0057 X F + 4.5 N
37 N
Load cells
F stands for the
measured force.
IV. Optical Quantities
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Photometry3– Automotive
Luxometers & Rulers
Up to 152 lx
@ 25 m
Up to 95 Klx
@ 1 m
0.025 x E + 0.07 lx
@ 25 m
0.025 x E + 0.07 klx
@ 1 m
Headlight patterm
E: Reading the
standard instrument in
klx at 1m or lx at 25m
Opacity3– Opacimeters
Up to 99.99 % opacity
0.11 % opacity
Neutral optical
density filters
Spectrophotometry –
Neutral Optical Density
Filters
(1 to 90) %
Transmittance [@
Wavelengths From
(440 to 750) nm]
0.0018 x %
Transmittance
+ 0.11
Spectrometer | ||
| 5 | Dimensional Metrology | (A2LA Cert. No. 7604.01) Revised 10/03/2025 Page 5 of 6
V. Thermodynamics
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Temperature3 –
Indicator, Sensor Set.
Digital Thermometers,
Temperature Indicators with
Thermocouple, Thermistor,
& RTD Sensors.
(0 to 100) °C
0.34 °C
Dry block isothermal
medium & digital
temperature indicator
with Type K
thermocouple
Temperature3 – Digital
Environmental
Thermometers,
Thermohygrometers,
Dataloggers
(10 to 55) °C
0.58 °C
Thermohygrometer &
climatic chamber
Relative Humidity3 –
Thermohygrometers,
Hygrometers, Dataloggers
(20 to 40) %
(40 to 60) %
(60 to 95) %
1.4 %
2.1 %
2.3 %
Thermohygrometer &
climatic chamber
VI. Time & Frequency
Parameter/Equipment
Range
CMC
2, 4 (±)
Comments
Frequency3, 5 – Inductive
Clamp-on RPM Meters,
Battery & Vibration
(300 to 9000) rpm
5.8 rpm
Frequency generator
.
Time Interval
3 –Taximeter
Testers
Up to 300 s
0.2 %
Stopwatch
1 This laboratory offers commercial calibration service and field service calibration
2 Calibration and Measurement Capability Uncertainty (C MC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration. | ||
| 6 | Dimensional Metrology | (A2LA Cert. No. 7604.01) Revised 10/03/2025 Page 6 of 6
3 Field calibration service is available for th ese calibrations. Please note the actual measurement
uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found
on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of
calibration and for other possible adverse effects such as those caused by transportation of the calibration
equipment. The usual allowance for the actual uncertain ty introduced by the item being calibrated, (e.g.,
resolution) must also be considered and this, on its own, could result in the actual measurement
uncertainty achievable on a customer’s site being larger than the CMC.
4 In the statement of CMC, percentages are to be read as percent of reading, unless noted otherwise. Force
applied values in N: Newtons.
5 The function generator senses the vibr ation of the engine and uses the battery voltage to simulate pulses
representing the engine vibration. These pulses (RPP) is converted to RPM by the function generator
representing the rotation of the engine.
6 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 7 | Dimensional Metrology | ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.