BALANCE METROLOGIA S.A.S ZOMAC

KM 1 VIA PEREIRA BG 200 VDA CAUYA, Anserma Caldas, Colombia, Anserma Caldas, Colombia

A2LA|7604.01ISO/IEC 17025Register refreshed 2026-10-09
Certificates
1
Scope items
7
Standards
0
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at BALANCE METROLOGIA S.A.S ZOMAC?

Claim this profile to keep it accurate.

Register record

A2LARefreshed
7604.01Active

Accredited standards

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Scope as published by A2LA

7 lines
A2LA

ISO/IEC 17025

Active

7604.01

The scope document we hold says it is valid until 2027-09-30.

View scope

Accredited scope, certificate 7604.01

LineDisciplineMethodMatrixRange
1Dimensional MetrologyISO/IEC 17025:2017-See scope document
2Dimensional Metrology--to 150 mm
3Dimensional Metrology--to 610 mm
4Chemical Testing
(A2LA Cert. No. 7604.01) Revised 10/03/2025 Page 4 of 6 Parameter/Equipment Range CMC2 (±) Comments Force3– Roller Brake Testers Up to 3000 N Up to 6000 N Up to 30 000 N 0.0054 x F + 4.7 N 0.0057 X F + 4.5 N 37 N Load cells F stands for the measured force. IV. Optical Quantities Parameter/Equipment Range CMC2, 4 (±) Comments Photometry3– Automotive Luxometers & Rulers Up to 152 lx @ 25 m Up to 95 Klx @ 1 m 0.025 x E + 0.07 lx @ 25 m 0.025 x E + 0.07 klx @ 1 m Headlight patterm E: Reading the standard instrument in klx at 1m or lx at 25m Opacity3– Opacimeters Up to 99.99 % opacity 0.11 % opacity Neutral optical density filters Spectrophotometry – Neutral Optical Density Filters (1 to 90) % Transmittance [@ Wavelengths From (440 to 750) nm] 0.0018 x % Transmittance + 0.11 Spectrometer
5Dimensional Metrology
(A2LA Cert. No. 7604.01) Revised 10/03/2025 Page 5 of 6 V. Thermodynamics Parameter/Equipment Range CMC2, 4 (±) Comments Temperature3 – Indicator, Sensor Set. Digital Thermometers, Temperature Indicators with Thermocouple, Thermistor, & RTD Sensors. (0 to 100) °C 0.34 °C Dry block isothermal medium & digital temperature indicator with Type K thermocouple Temperature3 – Digital Environmental Thermometers, Thermohygrometers, Dataloggers (10 to 55) °C 0.58 °C Thermohygrometer & climatic chamber Relative Humidity3 – Thermohygrometers, Hygrometers, Dataloggers (20 to 40) % (40 to 60) % (60 to 95) % 1.4 % 2.1 % 2.3 % Thermohygrometer & climatic chamber VI. Time & Frequency Parameter/Equipment Range CMC 2, 4 (±) Comments Frequency3, 5 – Inductive Clamp-on RPM Meters, Battery & Vibration (300 to 9000) rpm 5.8 rpm Frequency generator . Time Interval 3 –Taximeter Testers Up to 300 s 0.2 % Stopwatch  1 This laboratory offers commercial calibration service and field service calibration 2 Calibration and Measurement Capability Uncertainty (C MC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration.
6Dimensional Metrology
(A2LA Cert. No. 7604.01) Revised 10/03/2025 Page 6 of 6 3 Field calibration service is available for th ese calibrations. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertain ty introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, percentages are to be read as percent of reading, unless noted otherwise. Force applied values in N: Newtons. 5 The function generator senses the vibr ation of the engine and uses the battery voltage to simulate pulses representing the engine vibration. These pulses (RPP) is converted to RPM by the function generator representing the rotation of the engine. 6 This scope meets A2LA’s P112 Flexible Scope Policy.
7Dimensional MetrologyISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.