Borbolla Metrology, S.A. de C. V.
Calle Hidalgo Nte., No, 448, Zona Centro, Saltillo, Coah., CA 25000, Mexico, Zona Centro, Saltillo, Coah., Mexico
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at Borbolla Metrology, S.A. de C. V.?
Claim this profile to keep it accurate.
Register record
- A2LARefreshed
- 3486.01Active
Accredited standards
2Our reading of the A2LA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
ISO 10360-2Geometrical product specifications (GPS) - Acceptance and reverification tests for coordinate measuring machines (CMM) - Part 2: CMMs used for measuring linear dimensions
ISO/IEC 17025:2017; ISO 10360-2 sections 6; ISO 10360-5:2010 Section 6; IEC 17025
ISO 10360-5Geometrical product specifications (GPS) - Acceptance and reverification tests for coordinate measuring systems (CMS) - Part 5: Coordinate measuring machines (CMMs) using single and multiple stylus contacting probing systems using discrete point and/or scanning measuring mode
ISO/IEC 17025:2017; ISO 10360-2 sections 6; ISO 10360-5:2010 Section 6; IEC 17025
Scope as published by A2LA
3 lines
ISO/IEC 17025
Active3486.01
The scope document we hold says it is valid until 2027-08-31.
Accredited scope, certificate 3486.01
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | Dimensional Metrology | ISO/IEC 17025:2017; ISO 10360-2 sections 6; ISO 10360-5:2010 Section 6; IEC 17025 | - | to 30000 mm |
| 2 | Dimensional Metrology | (A2LA Cert. No. 3486.01) 8/21/2025 Page 2 of 2
______________________________________
1 This laboratory offers commercial and field calibration and dimensional testing services.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavi or of the customer’s device and to influences from the
circumstances of the specific calibration.
3 This laboratory performs field calibration activities for all parameters in the Scope. Please note the actual
measurement uncertainties achievable at customer's site can normally be expected to be larger than the
CMC uncertainty found on the A2LA Scope. Allowance must be made for aspects such as the
environment at the place of calibration and for other possible adverse effects such as those caused by
transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by
the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in
the actual measurement uncertainty achievable on a customer’s site being larger than the CMC.
4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in
millimeters.
5 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for
the types of dimensional tests listed above and is considered equivalent to that of a calibration. | ||
| 3 | Dimensional Metrology | ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.