UNIVERSIDAD DE ALCALA. CENTRO DE ALTA TECNOLOGIA Y HOMOLOGACION
CAMPUS UNIVERSITARIO. CTRA. MADRID-BARCELONA, KM. 33.600. EDIFICIO POLITÉCNICO, 28805, Alcalá de Henares, Spain
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
No contact information available
Open ENAC register entryWork at UNIVERSIDAD DE ALCALA. CENTRO DE ALTA TECNOLOGIA Y HOMOLOGACION?
Claim this profile to keep it accurate.
Register record
- ENACRefreshed
- 574/LE1083Active
Accredited standards
21Our reading of the ENAC scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
CISPR
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurementCertificate says EN 55011. Probably the same standard; not checked against the EN document.
UNE-EN IEC 61000-6-4; UNE-EN 61000-6-4: 2007; UNE-EN 61000-6-4 : 2007 ERRATUM :2008; UNE-EN 61000-6-4: 2007 /A1 :2011; UNE-EN 61000-6-2; UNE-EN 61000-6-2:2006; UNE-EN 55016-2-1; UNE-EN 55016-2-1: 2009; UNE-EN 55016-2-1: 2009/A1:2012; UNE-EN 55016-2-1: 2009/A2:2013; UNE-EN 55022:2011; UNE-EN 55022:2011/AC:2012; UNE-EN 55024:2011; UNE-EN 55024 :2011/A1 :2015; UNE-EN 55032; UNE-EN 55032:2013; UNE-EN 55032:2013/AC:2013; UNE-EN 55011; UNE-EN 55011:2011; UNE-EN 55011:2011/A1:2011
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: EmissionCertificate says EN 55014-1, IEC 55014-1. Probably the same standard; not checked against the EN document.
UNE-EN IEC 55014-1; UNE-EN 55014-1; UNE-EN 55014-1:2008; UNE-EN 55014-1: 2008/A1:2009; UNE-EN 55014-1:2008/A2:2012; UNE-EN IEC 55014-2; UNE-EN IEC 61326-1; UNE-EN 61326-1; UNE-EN 50155; UNE-EN 50155:2018; UNE-EN 50155:2007; UNE-EN 50155:2007 CORR:2010; UNE-EN 50121-3-2; UNE-EN 50121-3-2:2007; UNE-EN 50121-3-2; UNE-EN 50121-3-2:2007; UNE-EN 50121-4; UNE-EN 50121-4:2007
CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standardCertificate says IEC 55014-2. Probably the same standard; not checked against the EN document.
UNE-EN IEC 55014-1; UNE-EN 55014-1; UNE-EN 55014-1:2008; UNE-EN 55014-1: 2008/A1:2009; UNE-EN 55014-1:2008/A2:2012; UNE-EN IEC 55014-2; UNE-EN IEC 61326-1; UNE-EN 61326-1; UNE-EN 50155; UNE-EN 50155:2018; UNE-EN 50155:2007; UNE-EN 50155:2007 CORR:2010; UNE-EN 50121-3-2; UNE-EN 50121-3-2:2007; UNE-EN 50121-3-2; UNE-EN 50121-3-2:2007; UNE-EN 50121-4; UNE-EN 50121-4:2007
CISPR 16-2-1Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurementsCertificate says EN 55016-2-1. Probably the same standard; not checked against the EN document.
UNE-EN IEC 61000-6-4; UNE-EN 61000-6-4: 2007; UNE-EN 61000-6-4 : 2007 ERRATUM :2008; UNE-EN 61000-6-4: 2007 /A1 :2011; UNE-EN 61000-6-2; UNE-EN 61000-6-2:2006; UNE-EN 55016-2-1; UNE-EN 55016-2-1: 2009; UNE-EN 55016-2-1: 2009/A1:2012; UNE-EN 55016-2-1: 2009/A2:2013; UNE-EN 55022:2011; UNE-EN 55022:2011/AC:2012; UNE-EN 55024:2011; UNE-EN 55024 :2011/A1 :2015; UNE-EN 55032; UNE-EN 55032:2013; UNE-EN 55032:2013/AC:2013; UNE-EN 55011; UNE-EN 55011:2011; UNE-EN 55011:2011/A1:2011
CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurementCertificate says EN 55022. Probably the same standard; not checked against the EN document.
UNE-EN IEC 61000-6-4; UNE-EN 61000-6-4: 2007; UNE-EN 61000-6-4 : 2007 ERRATUM :2008; UNE-EN 61000-6-4: 2007 /A1 :2011; UNE-EN 61000-6-2; UNE-EN 61000-6-2:2006; UNE-EN 55016-2-1; UNE-EN 55016-2-1: 2009; UNE-EN 55016-2-1: 2009/A1:2012; UNE-EN 55016-2-1: 2009/A2:2013; UNE-EN 55022:2011; UNE-EN 55022:2011/AC:2012; UNE-EN 55024:2011; UNE-EN 55024 :2011/A1 :2015; UNE-EN 55032; UNE-EN 55032:2013; UNE-EN 55032:2013/AC:2013; UNE-EN 55011; UNE-EN 55011:2011; UNE-EN 55011:2011/A1:2011
CISPR 24Information technology equipment - Immunity characteristics - Limits and methods of measurementCertificate says EN 55024. Probably the same standard; not checked against the EN document.
UNE-EN IEC 61000-6-4; UNE-EN 61000-6-4: 2007; UNE-EN 61000-6-4 : 2007 ERRATUM :2008; UNE-EN 61000-6-4: 2007 /A1 :2011; UNE-EN 61000-6-2; UNE-EN 61000-6-2:2006; UNE-EN 55016-2-1; UNE-EN 55016-2-1: 2009; UNE-EN 55016-2-1: 2009/A1:2012; UNE-EN 55016-2-1: 2009/A2:2013; UNE-EN 55022:2011; UNE-EN 55022:2011/AC:2012; UNE-EN 55024:2011; UNE-EN 55024 :2011/A1 :2015; UNE-EN 55032; UNE-EN 55032:2013; UNE-EN 55032:2013/AC:2013; UNE-EN 55011; UNE-EN 55011:2011; UNE-EN 55011:2011/A1:2011
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirementsCertificate says EN 55032. Probably the same standard; not checked against the EN document.
UNE-EN IEC 61000-6-4; UNE-EN 61000-6-4: 2007; UNE-EN 61000-6-4 : 2007 ERRATUM :2008; UNE-EN 61000-6-4: 2007 /A1 :2011; UNE-EN 61000-6-2; UNE-EN 61000-6-2:2006; UNE-EN 55016-2-1; UNE-EN 55016-2-1: 2009; UNE-EN 55016-2-1: 2009/A1:2012; UNE-EN 55016-2-1: 2009/A2:2013; UNE-EN 55022:2011; UNE-EN 55022:2011/AC:2012; UNE-EN 55024:2011; UNE-EN 55024 :2011/A1 :2015; UNE-EN 55032; UNE-EN 55032:2013; UNE-EN 55032:2013/AC:2013; UNE-EN 55011; UNE-EN 55011:2011; UNE-EN 55011:2011/A1:2011
EN
EN 12015Electromagnetic compatibility - Product family standard for lifts, escalators and moving walks - Emission
ETSI EN 301 489-1; ETSI EN 301 489-1 V1.9.2; ETSI EN 301 489-3; UNE-EN 60601-1-2; UNE-EN 12015; UNE-EN 12015:2014; UNE-EN 12016
EN 12016Name not checked yet
ETSI EN 301 489-1; ETSI EN 301 489-1 V1.9.2; ETSI EN 301 489-3; UNE-EN 60601-1-2; UNE-EN 12015; UNE-EN 12015:2014; UNE-EN 12016
EN 50121-3-2Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus
UNE-EN IEC 55014-1; UNE-EN 55014-1; UNE-EN 55014-1:2008; UNE-EN 55014-1: 2008/A1:2009; UNE-EN 55014-1:2008/A2:2012; UNE-EN IEC 55014-2; UNE-EN IEC 61326-1; UNE-EN 61326-1; UNE-EN 50155; UNE-EN 50155:2018; UNE-EN 50155:2007; UNE-EN 50155:2007 CORR:2010; UNE-EN 50121-3-2; UNE-EN 50121-3-2:2007; UNE-EN 50121-3-2; UNE-EN 50121-3-2:2007; UNE-EN 50121-4; UNE-EN 50121-4:2007
EN 50121-4Railway applications - Electromagnetic compatibility - Part 4: Emission and immunity of the signalling and telecommunications apparatus
UNE-EN IEC 55014-1; UNE-EN 55014-1; UNE-EN 55014-1:2008; UNE-EN 55014-1: 2008/A1:2009; UNE-EN 55014-1:2008/A2:2012; UNE-EN IEC 55014-2; UNE-EN IEC 61326-1; UNE-EN 61326-1; UNE-EN 50155; UNE-EN 50155:2018; UNE-EN 50155:2007; UNE-EN 50155:2007 CORR:2010; UNE-EN 50121-3-2; UNE-EN 50121-3-2:2007; UNE-EN 50121-3-2; UNE-EN 50121-3-2:2007; UNE-EN 50121-4; UNE-EN 50121-4:2007
EN 50155Railway applications - Rolling stock - Electronic equipment
UNE-EN IEC 55014-1; UNE-EN 55014-1; UNE-EN 55014-1:2008; UNE-EN 55014-1: 2008/A1:2009; UNE-EN 55014-1:2008/A2:2012; UNE-EN IEC 55014-2; UNE-EN IEC 61326-1; UNE-EN 61326-1; UNE-EN 50155; UNE-EN 50155:2018; UNE-EN 50155:2007; UNE-EN 50155:2007 CORR:2010; UNE-EN 50121-3-2; UNE-EN 50121-3-2:2007; UNE-EN 50121-3-2; UNE-EN 50121-3-2:2007; UNE-EN 50121-4; UNE-EN 50121-4:2007
IEC 61000 series
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
UNE-EN 61000-6-3; UNE-EN 61000-6-3 :2007; UNE-EN 61000-6-3 :2007/A1 :2012; UNE-EN 61000-6-1; UNE-EN 61000-6-1: 2007; UNE-EN IEC 61000-6-8
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
UNE-EN IEC 61000-6-4; UNE-EN 61000-6-4: 2007; UNE-EN 61000-6-4 : 2007 ERRATUM :2008; UNE-EN 61000-6-4: 2007 /A1 :2011; UNE-EN 61000-6-2; UNE-EN 61000-6-2:2006; UNE-EN 55016-2-1; UNE-EN 55016-2-1: 2009; UNE-EN 55016-2-1: 2009/A1:2012; UNE-EN 55016-2-1: 2009/A2:2013; UNE-EN 55022:2011; UNE-EN 55022:2011/AC:2012; UNE-EN 55024:2011; UNE-EN 55024 :2011/A1 :2015; UNE-EN 55032; UNE-EN 55032:2013; UNE-EN 55032:2013/AC:2013; UNE-EN 55011; UNE-EN 55011:2011; UNE-EN 55011:2011/A1:2011
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environmentsCertificate says EN 61000-6-3. Probably the same standard; not checked against the EN document.
UNE-EN 61000-6-3; UNE-EN 61000-6-3 :2007; UNE-EN 61000-6-3 :2007/A1 :2012; UNE-EN 61000-6-1; UNE-EN 61000-6-1: 2007; UNE-EN IEC 61000-6-8
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
UNE-EN IEC 61000-6-4; UNE-EN 61000-6-4: 2007; UNE-EN 61000-6-4 : 2007 ERRATUM :2008; UNE-EN 61000-6-4: 2007 /A1 :2011; UNE-EN 61000-6-2; UNE-EN 61000-6-2:2006; UNE-EN 55016-2-1; UNE-EN 55016-2-1: 2009; UNE-EN 55016-2-1: 2009/A1:2012; UNE-EN 55016-2-1: 2009/A2:2013; UNE-EN 55022:2011; UNE-EN 55022:2011/AC:2012; UNE-EN 55024:2011; UNE-EN 55024 :2011/A1 :2015; UNE-EN 55032; UNE-EN 55032:2013; UNE-EN 55032:2013/AC:2013; UNE-EN 55011; UNE-EN 55011:2011; UNE-EN 55011:2011/A1:2011
IEC 61000-6-8Name not checked yet
UNE-EN 61000-6-3; UNE-EN 61000-6-3 :2007; UNE-EN 61000-6-3 :2007/A1 :2012; UNE-EN 61000-6-1; UNE-EN 61000-6-1: 2007; UNE-EN IEC 61000-6-8
Other standards
ETSI EN 301 489-1Name not checked yet
ETSI EN 301 489-1; ETSI EN 301 489-1 V1.9.2; ETSI EN 301 489-3; UNE-EN 60601-1-2; UNE-EN 12015; UNE-EN 12015:2014; UNE-EN 12016
ETSI EN 301 489-3Name not checked yet
ETSI EN 301 489-1; ETSI EN 301 489-1 V1.9.2; ETSI EN 301 489-3; UNE-EN 60601-1-2; UNE-EN 12015; UNE-EN 12015:2014; UNE-EN 12016
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
ETSI EN 301 489-1; ETSI EN 301 489-1 V1.9.2; ETSI EN 301 489-3; UNE-EN 60601-1-2; UNE-EN 12015; UNE-EN 12015:2014; UNE-EN 12016
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
UNE-EN IEC 55014-1; UNE-EN 55014-1; UNE-EN 55014-1:2008; UNE-EN 55014-1: 2008/A1:2009; UNE-EN 55014-1:2008/A2:2012; UNE-EN IEC 55014-2; UNE-EN IEC 61326-1; UNE-EN 61326-1; UNE-EN 50155; UNE-EN 50155:2018; UNE-EN 50155:2007; UNE-EN 50155:2007 CORR:2010; UNE-EN 50121-3-2; UNE-EN 50121-3-2:2007; UNE-EN 50121-3-2; UNE-EN 50121-3-2:2007; UNE-EN 50121-4; UNE-EN 50121-4:2007
Scope as published by ENAC
4 lines
ISO/IEC 17025
Active574/LE1083
Accredited scope, certificate 574/LE1083
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | electrical | UNE-EN 61000-6-3; UNE-EN 61000-6-3 :2007; UNE-EN 61000-6-3 :2007/A1 :2012; UNE-EN 61000-6-1; UNE-EN 61000-6-1: 2007; UNE-EN IEC 61000-6-8 | Equipos eléctricos y electrónicos para entorno doméstico, residencial, comercial e industria ligera; Equipos eléctricos y electrónicos profesionales en localizaciones comerciales y de industria ligera | - |
| 2 | electrical | UNE-EN IEC 61000-6-4; UNE-EN 61000-6-4: 2007; UNE-EN 61000-6-4 : 2007 ERRATUM :2008; UNE-EN 61000-6-4: 2007 /A1 :2011; UNE-EN 61000-6-2; UNE-EN 61000-6-2:2006; UNE-EN 55016-2-1; UNE-EN 55016-2-1: 2009; UNE-EN 55016-2-1: 2009/A1:2012; UNE-EN 55016-2-1: 2009/A2:2013; UNE-EN 55022:2011; UNE-EN 55022:2011/AC:2012; UNE-EN 55024:2011; UNE-EN 55024 :2011/A1 :2015; UNE-EN 55032; UNE-EN 55032:2013; UNE-EN 55032:2013/AC:2013; UNE-EN 55011; UNE-EN 55011:2011; UNE-EN 55011:2011/A1:2011 | Equipos eléctricos y electrónicos para entorno industrial; Equipos eléctricos y electrónicos; Equipos de Tecnología de la Información; Equipos multimedia; Equipos Industriales, científicos y médicos (ICM) | - |
| 3 | electrical | UNE-EN IEC 55014-1; UNE-EN 55014-1; UNE-EN 55014-1:2008; UNE-EN 55014-1: 2008/A1:2009; UNE-EN 55014-1:2008/A2:2012; UNE-EN IEC 55014-2; UNE-EN IEC 61326-1; UNE-EN 61326-1; UNE-EN 50155; UNE-EN 50155:2018; UNE-EN 50155:2007; UNE-EN 50155:2007 CORR:2010; UNE-EN 50121-3-2; UNE-EN 50121-3-2:2007; UNE-EN 50121-3-2; UNE-EN 50121-3-2:2007; UNE-EN 50121-4; UNE-EN 50121-4:2007 | Aparatos electrodomésticos, herramientas eléctricas y aparatos análogos; Equipos eléctricos para medida, control y uso en laboratorio; Aplicaciones ferroviarias. Equipos electrónicos utilizados sobre material rodante; Aparatos eléctricos y electrónicos diseñados para trabajar en material rodante ferroviario; Aparatos de señalización y telecomunicación utilizados en aplicaciones ferroviarias | - |
| 4 | electrical | ETSI EN 301 489-1; ETSI EN 301 489-1 V1.9.2; ETSI EN 301 489-3; UNE-EN 60601-1-2; UNE-EN 12015; UNE-EN 12015:2014; UNE-EN 12016 | Equipos de Radiocomunicación; Equipos de Radio de corto alcance (SRD); Equipos electromédicos; Ascensores, escaleras mecánicas y andenes móviles | 9000 to 40000000000 Hz |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
CAMPUS UNIVERSITARIO. CTRA. MADRID-BARCELONA, KM. 33.600. EDIFICIO POLITÉCNICO, Alcalá de Henares, 28805, ES
40.48195, -3.36398
Open in MapsAccreditation data refreshed from the ENAC register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ENAC entry linked above.