Lyri Calibrations
#4 Jack Smith Plaza, Eight Mile Rock, Freeport, Grand Bahama, Bahamas, Freeport, Grand Bahama, Bahamas
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at Lyri Calibrations?
Claim this profile to keep it accurate.
Register record
- A2LARefreshed
- 7608.01Active
Accredited standards
We have not yet extracted the standard numbers from this lab’s scope document. The scope text we hold is below.
Scope as published by A2LA
6 lines
ISO/IEC 17025
Active7608.01
The scope document we hold says it is valid until 2028-01-31.
Accredited scope, certificate 7608.01
This scope has not been split into individual lines yet. Below is the text of the scope document as published.
Part 1 of 6
(A2LA Cert. No. 7608.01) 06/09/2026 Page 1 of 5 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 LYRI CALIBRATIONS #4 Jack Smith Plaza, Eight Mile Rock Freeport, Grand Bahama, BAHAMAS Kishmere Rolle-Mckenzie Phone: 242 803 5974 CALIBRATION Valid To: January 31, 2028 Certificate Number: 7608.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations1, 6: I. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 5 (±) Comments DC Voltage – Generate & Measure3 Up to 100 mV (-10 to 75) mV 0.02 % of rdg + 2 counts 0.025 % of range + 1 count (via TC connector) Fluke 725 process calibrator DC Resistance – Generate & Measure3 (0 to 400) Ω (401 to 1500) Ω (1500 to 3200) Ω 0.1 Ω (4-wire), 0.15 Ω (2- & 3-wire) 0.5 Ω (4-wire), 1 Ω (2- & 3-wire) 1 1 Ω (4-wire), 1.5 Ω (2- & 3-wire) Fluke 725 process calibrator
Part 2 of 6
(A2LA Cert. No. 7608.01) 06/09/2026 Page 2 of 5 Parameter/Equipment Range CMC2, 5 (±) Comments DC Current – Generate & Measure3 Up to 24 mA 0.02 % of rdg + 2 counts Fluke 725 process calibrator Electrical Simulation of Thermocouple3 Type J Type K Type T (-200 to 0) °C (0 to 1200) °C (-200 to 0) °C (0 to 1370) °C (-200 to 0) °C (0 to 400) °C 1.0 °C 0.70 °C 1.2 °C 0.80 °C 1.0 °C 0.80 °C Fluke 725 process calibrator II. Fluid Quantities Parameter/Equipment Range CMC2, 4 (±) Comments Air Velocity – Measuring Equipment3 (0.40 to 10.00) m/s (10.0 to 25.00) m/s (80 to 1965) ft/min (1965 to 4900) ft/min 0.5 meters/sec 0.75 meters/sec 100 ft/min 150 ft/min Anemometer
Part 3 of 6
(A2LA Cert. No. 7608.01) 06/09/2026 Page 3 of 5 III. Mechanical Parameter/Equipment Range CMC2 (±) Comments Cardiac Functions – Measure3 ECG Tests Pacemaker Signals Arrhythmia Function Blood Pressure Function Cardiac Output Fetal/Maternal Function Pulse Oximeter 0.05 mV to 5 V 0.1 mV to 10 V / (30-240) bpm (30 to 300) bpm Up to 300 mmHg Up to 20 L/min (30 to 240) bpm (70 – 100) % SpO2 0.15 % rdg + 5 µV 0.2 % rdg + 10 µV 0.1 bpm 0.5 mmHg 2 % rdg 0.1 bpm 1 % SpO2 Fluke PROSIM 3 PROSIM SPOT SP02 Ventilators3 Flow Volume Pressure Temperature Humidity Up to 200 slpm Up to 100 L (-0.8 to 10) bar Up to 50 °C Up to 100 % RH 2 % rdg 2 % rdg 1 % rdg 0.5 °C 3 % RH VT900A/Vapor Anesthesia Machines3 Flow Volume Pressure O2 Concentration Up to 200 slpm Up to 100 L (-0.8 to 10) bar Up to 100 % 2 % rdg 2 % rdg 1 % rdg 1 % rdg VT900A/Vapor Defibrillators3 Energy Voltage Current Pulse Width (1 to 360) J (20 to 5000) V (0.4 to 100) A (1 to 50) ms 1.5 % rdg + 0.3 J 1 % rdg + 2 V 2 % rdg + 0.1 A 0.1 ms Impulse 7000DP
Text extracted from the accredited scope document. Layout and tables from the original may not carry over; the scope document itself is the authoritative copy.
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.