FindTestingLabs
Registers refreshed 2026-10-18.See refresh dates
Spain

ELITTORAL, ESTUDIOS DE INGENIERÍA COSTERA Y OCEANOGRÁFICA

Edificio Polivalente II del Parque Científico Tecnológico. Planta 1, oficinas 1 a 5. Campus Universitario de Tafira, 35017, Palmas de Gran Canaria, Spain

ENAC|1557/LE2846ISO/IEC 17025Register refreshed 2026-10-10
Certificates
1
Scope items
7
Standards
8
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Contact this laboratory

No contact information available

Open ENAC register entry
Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at ELITTORAL, ESTUDIOS DE INGENIERÍA COSTERA Y OCEANOGRÁFICA?

Claim this profile to keep it accurate.

Register record

ENACRefreshed
1557/LE2846Active

Accredited standards

8

Our reading of the ENAC scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

ISO 5667-9Water quality - Sampling - Part 9: Guidance on sampling from marine waters
As written on the certificate · Line 4 (ENAC 1557/LE2846)

ISO 5667-9; UNE-EN ISO 19458

ISO 5667-10Water quality - Sampling - Part 10: Guidance on sampling of waste water
As written on the certificate · Line 3 (ENAC 1557/LE2846)

ISO 5667-10; UNE-EN ISO 19458

ISO 5667-19Water quality - Sampling - Part 19: Guidance on sampling of marine sediments
As written on the certificate · Line 5 (ENAC 1557/LE2846)

ITC-05.01.09; UNE-EN ISO 5667-19; ISO 5667-19

ISO 5814Water quality - Determination of dissolved oxygen - Electrochemical probe method
As written on the certificate · Line 2 (ENAC 1557/LE2846)

UNE-EN ISO 10523; SM 2510 B; SM 2550; UNE-EN ISO 5814; ISO 17289

ISO 10523Water quality - Determination of pH
As written on the certificate · Line 2 (ENAC 1557/LE2846)

UNE-EN ISO 10523; SM 2510 B; SM 2550; UNE-EN ISO 5814; ISO 17289

ISO 16665Water quality - Guidelines for quantitative sampling and sample processing of marine soft-bottom macrofauna
As written on the certificate · Line 6 (ENAC 1557/LE2846)

ITC-04.04.04; Guidance document nº 25; ITC-05.01.01; UNE-EN ISO 16665; ITC-05.01.03; UNE-EN ISO 16665

ISO 17289Water quality - Determination of dissolved oxygen - Optical sensor method
As written on the certificate · Line 2 (ENAC 1557/LE2846)

UNE-EN ISO 10523; SM 2510 B; SM 2550; UNE-EN ISO 5814; ISO 17289

ISO 19458Water quality - Sampling for microbiological analysis
As written on the certificate · Line 3 (ENAC 1557/LE2846)

ISO 5667-10; UNE-EN ISO 19458

As written on the certificate · Line 4 (ENAC 1557/LE2846)

ISO 5667-9; UNE-EN ISO 19458

Scope as published by ENAC

7 lines
ENAC

ISO/IEC 17025

Active

1557/LE2846

View scope

Accredited scope, certificate 1557/LE2846

LineDisciplineMethodMatrixRange
1environmentalUNE-EN ISO/IEC 17025:2017Aguas residuales; Aguas marinas; Sedimentos marinos; Biota (Peces, crustáceos, moluscos, y equinodermos); Macroinvertebrados en sedimentos marinos-
2environmentalUNE-EN ISO 10523; SM 2510 B; SM 2550; UNE-EN ISO 5814; ISO 17289Aguas residuales; Aguas marinas-
3environmentalISO 5667-10; UNE-EN ISO 19458Aguas residuales-
4environmentalISO 5667-9; UNE-EN ISO 19458Aguas marinas-
5environmentalITC-05.01.09; UNE-EN ISO 5667-19; ISO 5667-19Sedimentos marinos-
6biological; chemical; environmentalITC-04.04.04; Guidance document nº 25; ITC-05.01.01; UNE-EN ISO 16665; ITC-05.01.03; UNE-EN ISO 16665Sedimentos marinos; Biota (Peces, crustáceos, moluscos, y equinodermos); Macroinvertebrados en sedimentos marinos-
7environmentalITC-05.01.14sedimentos marinos-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Edificio Polivalente II del Parque Científico Tecnológico. Planta 1, oficinas 1 a 5. Campus Universitario de Tafira, Palmas de Gran Canaria, 35017, ES

28.15793, -15.41965

Open in Maps

Accreditation data refreshed from the ENAC register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ENAC entry linked above.