FindTestingLabs
Registers refreshed 2026-10-18.See refresh dates
Canada

Alcohol Countermeasure Systems

Toronto, Canada

A2LA|4169.02A2LA|4169.01ISO/IEC 17025Register refreshed 2026-10-09
Certificates
2
Scope items
8
Standards
0
Locations
4
One of 4 locations. View the organization

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Alcohol Countermeasure Systems?

Claim this profile to keep it accurate.

Register record

A2LARefreshed
4169.02Active
4169.01Active

Accredited standards

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Scope as published by A2LA

8 lines
A2LA

ISO/IEC 17025

Active

4169.02

The scope document we hold says it is valid until 2027-03-31.

View scope

Accredited scope, certificate 4169.02

LineDisciplineMethodMatrixRange
1Dimensional MetrologyISO/IEC 17025:2017-See scope document
2Pressure Calibration
(A2LA Cert. No. 4169.01) 06/23/2025 Page 2 of 3 Parameter/Range Frequency CMC2, 3 (±) Comments AC Voltage – Measure (1 to 100) mV 10 Hz to 20 kHz 0.057 % + 0.022 mV GDM-8261 DMM III. Fluid Quantities Parameter/Equipment Range CMC2, 4, 5 (±) Comments Flow – Measure and Measuring Equipment (0.5 to 50) SLPM 0.21 % - 0.000 05 SLPM Flow meter Volumetric Dispensers and Dilutors (100 to 1000) µL 0.66 µL Gravimetric w/analytical balance IV. Mechanical Parameter/Equipment Range CMC2, 5 (±) Comments Pressure – Magnehelic Gages, Measure and Measuring Equipment (0 to 25) inH2O 0.59 inH2O Manometer V. Thermodynamics Parameter/Equipment Range CMC2, 4, 5 (±) Comments Temperature – Measuring Equipment (0 to 100) °C 0.023 % + 0.014 °C PRT w/indicator and oven/bath Temperature – Measure (-200 to 0) °C (0 to 300) °C -0.014 % + 0.09 °C 0.020 % + 0.09 °C PRT w/indicator
3Chemical TestingGC with FID detection and NIST SRMsAqueous Ethanol0 to 6.05 g/L
4Dimensional MetrologyISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

A2LA

ISO/IEC 17025

Active

4169.01

The scope document we hold says it is valid until 2027-03-31.

View scope

Accredited scope, certificate 4169.01

LineDisciplineMethodMatrixRange
1Dimensional MetrologyISO/IEC 17025:2017-See scope document
2Pressure Calibration
(A2LA Cert. No. 4169.01) 06/23/2025 Page 2 of 3 Parameter/Range Frequency CMC2, 3 (±) Comments AC Voltage – Measure (1 to 100) mV 10 Hz to 20 kHz 0.057 % + 0.022 mV GDM-8261 DMM III. Fluid Quantities Parameter/Equipment Range CMC2, 4, 5 (±) Comments Flow – Measure and Measuring Equipment (0.5 to 50) SLPM 0.21 % - 0.000 05 SLPM Flow meter Volumetric Dispensers and Dilutors (100 to 1000) µL 0.66 µL Gravimetric w/analytical balance IV. Mechanical Parameter/Equipment Range CMC2, 5 (±) Comments Pressure – Magnehelic Gages, Measure and Measuring Equipment (0 to 25) inH2O 0.59 inH2O Manometer V. Thermodynamics Parameter/Equipment Range CMC2, 4, 5 (±) Comments Temperature – Measuring Equipment (0 to 100) °C 0.023 % + 0.014 °C PRT w/indicator and oven/bath Temperature – Measure (-200 to 0) °C (0 to 300) °C -0.014 % + 0.09 °C 0.020 % + 0.09 °C PRT w/indicator
3Chemical TestingGC with FID detection and NIST SRMsAqueous Ethanol0 to 6.05 g/L
4Dimensional MetrologyISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Other Locations

3 other sites in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.