FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
United Kingdom

Sigma-HSE (UK)

Unit 2, Moorside Point, Moorside Road, Winall, SO23 7RX, Winchester, United Kingdom

UKAS|9248ISO/IEC 17025Register refreshed 2026-09-25
Certificates
1
Scope items
2
Standards
8
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Sigma-HSE (UK)?

Claim this profile to keep it accurate.

Register record

UKASRefreshed
9248Active

Accredited standards

8

Our reading of the UKAS scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

ASTM E537Name not checked yet
As written on the certificate · Line 2 (UKAS 9248)

ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; ASTM E537; ASTM E1981

ASTM E1981Name not checked yet
As written on the certificate · Line 2 (UKAS 9248)

ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; ASTM E537; ASTM E1981

EN 13821Name not checked yet
As written on the certificate · Line 1 (UKAS 9248)

BS EN ISO/IEC 80079-20-2:2016 Minimum Ignition Temperature BS EN 50281-2-1:1999 Method B - Minimum ignition temperature Dust cloud in a furnace at a constant temperature BS EN ISO/IEC 80079-20-2:2016 Layer Ignition Temperature BS EN 50281-2-1:1999 Dust layer on a heated surface at a constant temperature BS EN ISO/IEC 80079-20-2:2016 Minimum Explosive Concentration BS EN 14034-3: 2006; BS EN ISO/IEC 80079-20-2:2016: 7; BS EN 13821: 2002; BS EN 14034-1: 2004; BS EN 14034-2: 2006

EN 14034-1Name not checked yet
As written on the certificate · Line 1 (UKAS 9248)

BS EN ISO/IEC 80079-20-2:2016 Minimum Ignition Temperature BS EN 50281-2-1:1999 Method B - Minimum ignition temperature Dust cloud in a furnace at a constant temperature BS EN ISO/IEC 80079-20-2:2016 Layer Ignition Temperature BS EN 50281-2-1:1999 Dust layer on a heated surface at a constant temperature BS EN ISO/IEC 80079-20-2:2016 Minimum Explosive Concentration BS EN 14034-3: 2006; BS EN ISO/IEC 80079-20-2:2016: 7; BS EN 13821: 2002; BS EN 14034-1: 2004; BS EN 14034-2: 2006

EN 14034-2Name not checked yet
As written on the certificate · Line 1 (UKAS 9248)

BS EN ISO/IEC 80079-20-2:2016 Minimum Ignition Temperature BS EN 50281-2-1:1999 Method B - Minimum ignition temperature Dust cloud in a furnace at a constant temperature BS EN ISO/IEC 80079-20-2:2016 Layer Ignition Temperature BS EN 50281-2-1:1999 Dust layer on a heated surface at a constant temperature BS EN ISO/IEC 80079-20-2:2016 Minimum Explosive Concentration BS EN 14034-3: 2006; BS EN ISO/IEC 80079-20-2:2016: 7; BS EN 13821: 2002; BS EN 14034-1: 2004; BS EN 14034-2: 2006

EN 14034-3Name not checked yet
As written on the certificate · Line 1 (UKAS 9248)

BS EN ISO/IEC 80079-20-2:2016 Minimum Ignition Temperature BS EN 50281-2-1:1999 Method B - Minimum ignition temperature Dust cloud in a furnace at a constant temperature BS EN ISO/IEC 80079-20-2:2016 Layer Ignition Temperature BS EN 50281-2-1:1999 Dust layer on a heated surface at a constant temperature BS EN ISO/IEC 80079-20-2:2016 Minimum Explosive Concentration BS EN 14034-3: 2006; BS EN ISO/IEC 80079-20-2:2016: 7; BS EN 13821: 2002; BS EN 14034-1: 2004; BS EN 14034-2: 2006

EN 50281-2-1Name not checked yet
As written on the certificate · Line 1 (UKAS 9248)

BS EN ISO/IEC 80079-20-2:2016 Minimum Ignition Temperature BS EN 50281-2-1:1999 Method B - Minimum ignition temperature Dust cloud in a furnace at a constant temperature BS EN ISO/IEC 80079-20-2:2016 Layer Ignition Temperature BS EN 50281-2-1:1999 Dust layer on a heated surface at a constant temperature BS EN ISO/IEC 80079-20-2:2016 Minimum Explosive Concentration BS EN 14034-3: 2006; BS EN ISO/IEC 80079-20-2:2016: 7; BS EN 13821: 2002; BS EN 14034-1: 2004; BS EN 14034-2: 2006

ISO/IEC 80079-20-2Explosive atmospheres - Part 20-2: Material characteristics - Combustible dusts test methods
As written on the certificate · Line 1 (UKAS 9248)

BS EN ISO/IEC 80079-20-2:2016 Minimum Ignition Temperature BS EN 50281-2-1:1999 Method B - Minimum ignition temperature Dust cloud in a furnace at a constant temperature BS EN ISO/IEC 80079-20-2:2016 Layer Ignition Temperature BS EN 50281-2-1:1999 Dust layer on a heated surface at a constant temperature BS EN ISO/IEC 80079-20-2:2016 Minimum Explosive Concentration BS EN 14034-3: 2006; BS EN ISO/IEC 80079-20-2:2016: 7; BS EN 13821: 2002; BS EN 14034-1: 2004; BS EN 14034-2: 2006

Scope as published by UKAS

2 lines
UKAS

ISO/IEC 17025

Active

9248

View scope

Accredited scope, certificate 9248

LineDisciplineMethodMatrixRange
1Materials TestingBS EN ISO/IEC 80079-20-2:2016 Minimum Ignition Temperature BS EN 50281-2-1:1999 Method B - Minimum ignition temperature Dust cloud in a furnace at a constant temperature BS EN ISO/IEC 80079-20-2:2016 Layer Ignition Temperature BS EN 50281-2-1:1999 Dust layer on a heated surface at a constant temperature BS EN ISO/IEC 80079-20-2:2016 Minimum Explosive Concentration BS EN 14034-3: 2006; BS EN ISO/IEC 80079-20-2:2016: 7; BS EN 13821: 2002; BS EN 14034-1: 2004; BS EN 14034-2: 2006Air-
2Materials TestingISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; ASTM E537; ASTM E1981Reactive chemicals / materials; Reactive chemicals / materials-

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Unit 2, Moorside Point, Moorside Road, Winall, Winchester, SO23 7RX, GB

51.06128, -1.31317

Open in Maps

Accreditation data refreshed from the UKAS register on .