FindTestingLabs
Registers refreshed 2026-10-18.See refresh dates
Spain

CANAGROSA LAB&SERVICES

Parque Aeronáutico Empresarial Aerópolis. C/ Wilbur y Orville Wright nº 15, 41300, Rinconada, Spain

ENAC|337/LE1870ISO/IEC 17025Register refreshed 2026-10-10
Certificates
1
Scope items
5
Standards
15
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Contact this laboratory

No contact information available

Open ENAC register entry
Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at CANAGROSA LAB&SERVICES?

Claim this profile to keep it accurate.

Register record

ENACRefreshed
337/LE1870Active

Accredited standards

15

Our reading of the ENAC scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

ASTM

ASTM B117Standard Practice for Operating Salt Spray (Fog) Apparatus
As written on the certificate · Line 1 (ENAC 337/LE1870)

ASTM B 117; ISO 9227; UNE-EN ISO 9227; ISO 2409; UNE-EN ISO 2409

ASTM D2240Standard Test Method for Rubber Property - Durometer Hardness
As written on the certificate · Line 2 (ENAC 337/LE1870)

ASTM D 2240; ISO 48-4; ISO 2360; AITM 6-6006; ISO 2808; UNE-EN ISO 2808; UNE-EN 2832; ASTM F519; AITM 1-0033; ASTM F326; AITM 3-0030; AITM 3-0032

ASTM D4294Name not checked yet
As written on the certificate · Line 5 (ENAC 337/LE1870)

ASTM D4809; ASTM D7171; ASTM D4294

ASTM D4809Name not checked yet
As written on the certificate · Line 5 (ENAC 337/LE1870)

ASTM D4809; ASTM D7171; ASTM D4294

ASTM D7171Name not checked yet
As written on the certificate · Line 5 (ENAC 337/LE1870)

ASTM D4809; ASTM D7171; ASTM D4294

ASTM F326Name not checked yet
As written on the certificate · Line 2 (ENAC 337/LE1870)

ASTM D 2240; ISO 48-4; ISO 2360; AITM 6-6006; ISO 2808; UNE-EN ISO 2808; UNE-EN 2832; ASTM F519; AITM 1-0033; ASTM F326; AITM 3-0030; AITM 3-0032

ASTM F519Name not checked yet
As written on the certificate · Line 2 (ENAC 337/LE1870)

ASTM D 2240; ISO 48-4; ISO 2360; AITM 6-6006; ISO 2808; UNE-EN ISO 2808; UNE-EN 2832; ASTM F519; AITM 1-0033; ASTM F326; AITM 3-0030; AITM 3-0032

ISO

ISO 48-4Rubber, vulcanized or thermoplastic - Determination of hardness - Part 4: Indentation hardness by durometer method (Shore hardness)
As written on the certificate · Line 2 (ENAC 337/LE1870)

ASTM D 2240; ISO 48-4; ISO 2360; AITM 6-6006; ISO 2808; UNE-EN ISO 2808; UNE-EN 2832; ASTM F519; AITM 1-0033; ASTM F326; AITM 3-0030; AITM 3-0032

ISO 2360Non-conductive coatings on non-magnetic electrically conductive base metals - Measurement of coating thickness - Amplitude-sensitive eddy-current method
As written on the certificate · Line 2 (ENAC 337/LE1870)

ASTM D 2240; ISO 48-4; ISO 2360; AITM 6-6006; ISO 2808; UNE-EN ISO 2808; UNE-EN 2832; ASTM F519; AITM 1-0033; ASTM F326; AITM 3-0030; AITM 3-0032

ISO 2409Paints and varnishes - Cross-cut test
As written on the certificate · Line 1 (ENAC 337/LE1870)

ASTM B 117; ISO 9227; UNE-EN ISO 9227; ISO 2409; UNE-EN ISO 2409

ISO 2808Paints and varnishes - Determination of film thickness
As written on the certificate · Line 2 (ENAC 337/LE1870)

ASTM D 2240; ISO 48-4; ISO 2360; AITM 6-6006; ISO 2808; UNE-EN ISO 2808; UNE-EN 2832; ASTM F519; AITM 1-0033; ASTM F326; AITM 3-0030; AITM 3-0032

ISO 9227Corrosion tests in artificial atmospheres - Salt spray tests
As written on the certificate · Line 1 (ENAC 337/LE1870)

ASTM B 117; ISO 9227; UNE-EN ISO 9227; ISO 2409; UNE-EN ISO 2409

ISO 11500Hydraulic fluid power - Determination of the particulate contamination level of a liquid sample by automatic particle counting using the light-extinction principle
As written on the certificate · Line 4 (ENAC 337/LE1870)

NSA 307110; ISO 11500; SAE ARP 5088; ISO 12937; UNE-EN ISO 12937; AITM 7-0010

ISO 12937Petroleum products - Determination of water - Coulometric Karl Fischer titration method
As written on the certificate · Line 3 (ENAC 337/LE1870)

PNT B 938; PNT B 939; ISO 12937; UNE-EN ISO 12937

As written on the certificate · Line 4 (ENAC 337/LE1870)

NSA 307110; ISO 11500; SAE ARP 5088; ISO 12937; UNE-EN ISO 12937; AITM 7-0010

Other standards

EN 2832Name not checked yet
As written on the certificate · Line 2 (ENAC 337/LE1870)

ASTM D 2240; ISO 48-4; ISO 2360; AITM 6-6006; ISO 2808; UNE-EN ISO 2808; UNE-EN 2832; ASTM F519; AITM 1-0033; ASTM F326; AITM 3-0030; AITM 3-0032

Scope as published by ENAC

5 lines
ENAC

ISO/IEC 17025

Active

337/LE1870

View scope

Accredited scope, certificate 337/LE1870

LineDisciplineMethodMatrixRange
1materialsASTM B 117; ISO 9227; UNE-EN ISO 9227; ISO 2409; UNE-EN ISO 2409Metallic materials and coatings; Paints and varnishes-
2materialsASTM D 2240; ISO 48-4; ISO 2360; AITM 6-6006; ISO 2808; UNE-EN ISO 2808; UNE-EN 2832; ASTM F519; AITM 1-0033; ASTM F326; AITM 3-0030; AITM 3-0032Sellantes y Adhesivos; Recubrimientos no conductores sobre materiales base conductores no magnéticos; Aceros y sus recubrimientos; Sellantes; Baños Electrolíticos/ Plating baths; Soluciones de baños de cadmiado electrolítico; Soluciones de baño de tratamiento superficial (Anodizado sulfotartárico); Soluciones de baños de tratamiento superficial (baño de desoxidado)-
3chemicalPNT B 938; PNT B 939; ISO 12937; UNE-EN ISO 12937Soluciones de baño de tratamiento superficial carácter básico (baño de desengrase alcalino); Soluciones de baños de tratamiento superficial de carácter ácido; Fluidos hidráulicos, aceites y combustibles; Fluidos hidráulicos (de base mineral)See scope document
4chemicalNSA 307110; ISO 11500; SAE ARP 5088; ISO 12937; UNE-EN ISO 12937; AITM 7-0010Fluidos hidráulicos (de base ester-fosfatada) tipo NSA 307110; Aceites lubricantes (de base ester polialcohólica); Combustibles de aviaciónSee scope document
5materialsASTM D4809; ASTM D7171; ASTM D4294combustion products; hydrogen; sulfurSee scope document

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Parque Aeronáutico Empresarial Aerópolis. C/ Wilbur y Orville Wright nº 15, Rinconada, 41300, ES

42.85888, -4.71803

Open in Maps

Accreditation data refreshed from the ENAC register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ENAC entry linked above.