FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
United States

Device Conformity and Testing

suite 211, 94 jackson rd, 94 jackson rd, suite 211, 01434, Devens, MA, United States

A2LA|6136.01ISO/IEC 17025Register refreshed 2026-09-25
Certificates
1
Scope items
3
Standards
14
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Device Conformity and Testing?

Claim this profile to keep it accurate.

Register record

A2LARefreshed
6136.01Active

Accredited standards

14

Our reading of the A2LA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

IEC 60601 series

IEC 60601-1-4Name not checked yet
As written on the certificate · Line 1 (A2LA 6136.01)

IEC 60950-1:2005/AMD2:2013; IEC 62368-1:2018; IEC 62368-1 Ed. 4 2023-05; IEC 60601-1:1988/AMD2:1995; IEC 60601-1:2005+A1:2012; IEC 60601-1:2005+A1:2012+A2:2020; ES60601-1:2005/(R)2012 and A1:2012 C1:2009/(R)2012 and A2:2010/(R)2012 (Consolidated Text); IEC 60601-1-4:1996/AMD1:1999; IEC 60601-1-6:2010+A1:2013+A2:2020; IEC 60601-1-6 Edition 3.1 2013-10; IEC 60601-1-6 Edition 3.2 2020-07 CONSOLIDATED VERSION; IEC 60601-1-8:2006+A1:2012+A2:2020; IEC 60601-1-8 Edition 2.1 2012-11; IEC 60601-1-8 Edition 2.2 2020-07 CONSOLIDATED VERSION; IEC 60601-1-11:2015+A1:2020; IEC 60601-1-11 Edition 2.0 2015-01; IEC 60601-1-11 Edition 2.1 2020-07 CONSOLIDATED VERSION; IEC 60601-2-2 Edition 6.0 2017-03; IEC 60601-2-2 Edition 6.1 2023-02; IEC 60601-2-18:2009-08

IEC 60601-1-6Name not checked yet
As written on the certificate · Line 1 (A2LA 6136.01)

IEC 60950-1:2005/AMD2:2013; IEC 62368-1:2018; IEC 62368-1 Ed. 4 2023-05; IEC 60601-1:1988/AMD2:1995; IEC 60601-1:2005+A1:2012; IEC 60601-1:2005+A1:2012+A2:2020; ES60601-1:2005/(R)2012 and A1:2012 C1:2009/(R)2012 and A2:2010/(R)2012 (Consolidated Text); IEC 60601-1-4:1996/AMD1:1999; IEC 60601-1-6:2010+A1:2013+A2:2020; IEC 60601-1-6 Edition 3.1 2013-10; IEC 60601-1-6 Edition 3.2 2020-07 CONSOLIDATED VERSION; IEC 60601-1-8:2006+A1:2012+A2:2020; IEC 60601-1-8 Edition 2.1 2012-11; IEC 60601-1-8 Edition 2.2 2020-07 CONSOLIDATED VERSION; IEC 60601-1-11:2015+A1:2020; IEC 60601-1-11 Edition 2.0 2015-01; IEC 60601-1-11 Edition 2.1 2020-07 CONSOLIDATED VERSION; IEC 60601-2-2 Edition 6.0 2017-03; IEC 60601-2-2 Edition 6.1 2023-02; IEC 60601-2-18:2009-08

As written on the certificate · Line 2 (A2LA 6136.01)

IEC 60601-2-64:2014-09; IEC 60601-2-68 Edition 1.0 2014-09; IEC 61010-1:2010+A1:2016; IEC 61010-1 Edition 3.1 2017-01; IEC 61010-2-010:2019; IEC 61010-2-051:2018; IEC 61010-2-101:2018; IEC 60601-1-6 Edition 3.2 2020-07; IEC 60601-1-8 Edition 2.2 2020-07; IEC 60601-1-11 Edition 2.1 2020-07; IEC 60601-2-2 Edition 6.0 2017-03

IEC 60601-1-8Name not checked yet
As written on the certificate · Line 1 (A2LA 6136.01)

IEC 60950-1:2005/AMD2:2013; IEC 62368-1:2018; IEC 62368-1 Ed. 4 2023-05; IEC 60601-1:1988/AMD2:1995; IEC 60601-1:2005+A1:2012; IEC 60601-1:2005+A1:2012+A2:2020; ES60601-1:2005/(R)2012 and A1:2012 C1:2009/(R)2012 and A2:2010/(R)2012 (Consolidated Text); IEC 60601-1-4:1996/AMD1:1999; IEC 60601-1-6:2010+A1:2013+A2:2020; IEC 60601-1-6 Edition 3.1 2013-10; IEC 60601-1-6 Edition 3.2 2020-07 CONSOLIDATED VERSION; IEC 60601-1-8:2006+A1:2012+A2:2020; IEC 60601-1-8 Edition 2.1 2012-11; IEC 60601-1-8 Edition 2.2 2020-07 CONSOLIDATED VERSION; IEC 60601-1-11:2015+A1:2020; IEC 60601-1-11 Edition 2.0 2015-01; IEC 60601-1-11 Edition 2.1 2020-07 CONSOLIDATED VERSION; IEC 60601-2-2 Edition 6.0 2017-03; IEC 60601-2-2 Edition 6.1 2023-02; IEC 60601-2-18:2009-08

As written on the certificate · Line 2 (A2LA 6136.01)

IEC 60601-2-64:2014-09; IEC 60601-2-68 Edition 1.0 2014-09; IEC 61010-1:2010+A1:2016; IEC 61010-1 Edition 3.1 2017-01; IEC 61010-2-010:2019; IEC 61010-2-051:2018; IEC 61010-2-101:2018; IEC 60601-1-6 Edition 3.2 2020-07; IEC 60601-1-8 Edition 2.2 2020-07; IEC 60601-1-11 Edition 2.1 2020-07; IEC 60601-2-2 Edition 6.0 2017-03

IEC 60601-1-11Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance - Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment
As written on the certificate · Line 1 (A2LA 6136.01)

IEC 60950-1:2005/AMD2:2013; IEC 62368-1:2018; IEC 62368-1 Ed. 4 2023-05; IEC 60601-1:1988/AMD2:1995; IEC 60601-1:2005+A1:2012; IEC 60601-1:2005+A1:2012+A2:2020; ES60601-1:2005/(R)2012 and A1:2012 C1:2009/(R)2012 and A2:2010/(R)2012 (Consolidated Text); IEC 60601-1-4:1996/AMD1:1999; IEC 60601-1-6:2010+A1:2013+A2:2020; IEC 60601-1-6 Edition 3.1 2013-10; IEC 60601-1-6 Edition 3.2 2020-07 CONSOLIDATED VERSION; IEC 60601-1-8:2006+A1:2012+A2:2020; IEC 60601-1-8 Edition 2.1 2012-11; IEC 60601-1-8 Edition 2.2 2020-07 CONSOLIDATED VERSION; IEC 60601-1-11:2015+A1:2020; IEC 60601-1-11 Edition 2.0 2015-01; IEC 60601-1-11 Edition 2.1 2020-07 CONSOLIDATED VERSION; IEC 60601-2-2 Edition 6.0 2017-03; IEC 60601-2-2 Edition 6.1 2023-02; IEC 60601-2-18:2009-08

As written on the certificate · Line 2 (A2LA 6136.01)

IEC 60601-2-64:2014-09; IEC 60601-2-68 Edition 1.0 2014-09; IEC 61010-1:2010+A1:2016; IEC 61010-1 Edition 3.1 2017-01; IEC 61010-2-010:2019; IEC 61010-2-051:2018; IEC 61010-2-101:2018; IEC 60601-1-6 Edition 3.2 2020-07; IEC 60601-1-8 Edition 2.2 2020-07; IEC 60601-1-11 Edition 2.1 2020-07; IEC 60601-2-2 Edition 6.0 2017-03

IEC 60601-2-2Name not checked yet
As written on the certificate · Line 1 (A2LA 6136.01)

IEC 60950-1:2005/AMD2:2013; IEC 62368-1:2018; IEC 62368-1 Ed. 4 2023-05; IEC 60601-1:1988/AMD2:1995; IEC 60601-1:2005+A1:2012; IEC 60601-1:2005+A1:2012+A2:2020; ES60601-1:2005/(R)2012 and A1:2012 C1:2009/(R)2012 and A2:2010/(R)2012 (Consolidated Text); IEC 60601-1-4:1996/AMD1:1999; IEC 60601-1-6:2010+A1:2013+A2:2020; IEC 60601-1-6 Edition 3.1 2013-10; IEC 60601-1-6 Edition 3.2 2020-07 CONSOLIDATED VERSION; IEC 60601-1-8:2006+A1:2012+A2:2020; IEC 60601-1-8 Edition 2.1 2012-11; IEC 60601-1-8 Edition 2.2 2020-07 CONSOLIDATED VERSION; IEC 60601-1-11:2015+A1:2020; IEC 60601-1-11 Edition 2.0 2015-01; IEC 60601-1-11 Edition 2.1 2020-07 CONSOLIDATED VERSION; IEC 60601-2-2 Edition 6.0 2017-03; IEC 60601-2-2 Edition 6.1 2023-02; IEC 60601-2-18:2009-08

As written on the certificate · Line 2 (A2LA 6136.01)

IEC 60601-2-64:2014-09; IEC 60601-2-68 Edition 1.0 2014-09; IEC 61010-1:2010+A1:2016; IEC 61010-1 Edition 3.1 2017-01; IEC 61010-2-010:2019; IEC 61010-2-051:2018; IEC 61010-2-101:2018; IEC 60601-1-6 Edition 3.2 2020-07; IEC 60601-1-8 Edition 2.2 2020-07; IEC 60601-1-11 Edition 2.1 2020-07; IEC 60601-2-2 Edition 6.0 2017-03

IEC 60601-2-18Name not checked yet
As written on the certificate · Line 1 (A2LA 6136.01)

IEC 60950-1:2005/AMD2:2013; IEC 62368-1:2018; IEC 62368-1 Ed. 4 2023-05; IEC 60601-1:1988/AMD2:1995; IEC 60601-1:2005+A1:2012; IEC 60601-1:2005+A1:2012+A2:2020; ES60601-1:2005/(R)2012 and A1:2012 C1:2009/(R)2012 and A2:2010/(R)2012 (Consolidated Text); IEC 60601-1-4:1996/AMD1:1999; IEC 60601-1-6:2010+A1:2013+A2:2020; IEC 60601-1-6 Edition 3.1 2013-10; IEC 60601-1-6 Edition 3.2 2020-07 CONSOLIDATED VERSION; IEC 60601-1-8:2006+A1:2012+A2:2020; IEC 60601-1-8 Edition 2.1 2012-11; IEC 60601-1-8 Edition 2.2 2020-07 CONSOLIDATED VERSION; IEC 60601-1-11:2015+A1:2020; IEC 60601-1-11 Edition 2.0 2015-01; IEC 60601-1-11 Edition 2.1 2020-07 CONSOLIDATED VERSION; IEC 60601-2-2 Edition 6.0 2017-03; IEC 60601-2-2 Edition 6.1 2023-02; IEC 60601-2-18:2009-08

IEC 60601-2-64Name not checked yet
As written on the certificate · Line 2 (A2LA 6136.01)

IEC 60601-2-64:2014-09; IEC 60601-2-68 Edition 1.0 2014-09; IEC 61010-1:2010+A1:2016; IEC 61010-1 Edition 3.1 2017-01; IEC 61010-2-010:2019; IEC 61010-2-051:2018; IEC 61010-2-101:2018; IEC 60601-1-6 Edition 3.2 2020-07; IEC 60601-1-8 Edition 2.2 2020-07; IEC 60601-1-11 Edition 2.1 2020-07; IEC 60601-2-2 Edition 6.0 2017-03

IEC 60601-2-68Name not checked yet
As written on the certificate · Line 2 (A2LA 6136.01)

IEC 60601-2-64:2014-09; IEC 60601-2-68 Edition 1.0 2014-09; IEC 61010-1:2010+A1:2016; IEC 61010-1 Edition 3.1 2017-01; IEC 61010-2-010:2019; IEC 61010-2-051:2018; IEC 61010-2-101:2018; IEC 60601-1-6 Edition 3.2 2020-07; IEC 60601-1-8 Edition 2.2 2020-07; IEC 60601-1-11 Edition 2.1 2020-07; IEC 60601-2-2 Edition 6.0 2017-03

IEC 61010 series

IEC 61010-1Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
As written on the certificate · Line 2 (A2LA 6136.01)

IEC 60601-2-64:2014-09; IEC 60601-2-68 Edition 1.0 2014-09; IEC 61010-1:2010+A1:2016; IEC 61010-1 Edition 3.1 2017-01; IEC 61010-2-010:2019; IEC 61010-2-051:2018; IEC 61010-2-101:2018; IEC 60601-1-6 Edition 3.2 2020-07; IEC 60601-1-8 Edition 2.2 2020-07; IEC 60601-1-11 Edition 2.1 2020-07; IEC 60601-2-2 Edition 6.0 2017-03

IEC 61010-2-010Name not checked yet
As written on the certificate · Line 2 (A2LA 6136.01)

IEC 60601-2-64:2014-09; IEC 60601-2-68 Edition 1.0 2014-09; IEC 61010-1:2010+A1:2016; IEC 61010-1 Edition 3.1 2017-01; IEC 61010-2-010:2019; IEC 61010-2-051:2018; IEC 61010-2-101:2018; IEC 60601-1-6 Edition 3.2 2020-07; IEC 60601-1-8 Edition 2.2 2020-07; IEC 60601-1-11 Edition 2.1 2020-07; IEC 60601-2-2 Edition 6.0 2017-03

IEC 61010-2-051Name not checked yet
As written on the certificate · Line 2 (A2LA 6136.01)

IEC 60601-2-64:2014-09; IEC 60601-2-68 Edition 1.0 2014-09; IEC 61010-1:2010+A1:2016; IEC 61010-1 Edition 3.1 2017-01; IEC 61010-2-010:2019; IEC 61010-2-051:2018; IEC 61010-2-101:2018; IEC 60601-1-6 Edition 3.2 2020-07; IEC 60601-1-8 Edition 2.2 2020-07; IEC 60601-1-11 Edition 2.1 2020-07; IEC 60601-2-2 Edition 6.0 2017-03

IEC 61010-2-101Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-101: Particular requirements for in vitro diagnostic (IVD) medical equipment
As written on the certificate · Line 2 (A2LA 6136.01)

IEC 60601-2-64:2014-09; IEC 60601-2-68 Edition 1.0 2014-09; IEC 61010-1:2010+A1:2016; IEC 61010-1 Edition 3.1 2017-01; IEC 61010-2-010:2019; IEC 61010-2-051:2018; IEC 61010-2-101:2018; IEC 60601-1-6 Edition 3.2 2020-07; IEC 60601-1-8 Edition 2.2 2020-07; IEC 60601-1-11 Edition 2.1 2020-07; IEC 60601-2-2 Edition 6.0 2017-03

Other standards

IEC 60950-1Information technology equipment - Safety - Part 1: General requirements
As written on the certificate · Line 1 (A2LA 6136.01)

IEC 60950-1:2005/AMD2:2013; IEC 62368-1:2018; IEC 62368-1 Ed. 4 2023-05; IEC 60601-1:1988/AMD2:1995; IEC 60601-1:2005+A1:2012; IEC 60601-1:2005+A1:2012+A2:2020; ES60601-1:2005/(R)2012 and A1:2012 C1:2009/(R)2012 and A2:2010/(R)2012 (Consolidated Text); IEC 60601-1-4:1996/AMD1:1999; IEC 60601-1-6:2010+A1:2013+A2:2020; IEC 60601-1-6 Edition 3.1 2013-10; IEC 60601-1-6 Edition 3.2 2020-07 CONSOLIDATED VERSION; IEC 60601-1-8:2006+A1:2012+A2:2020; IEC 60601-1-8 Edition 2.1 2012-11; IEC 60601-1-8 Edition 2.2 2020-07 CONSOLIDATED VERSION; IEC 60601-1-11:2015+A1:2020; IEC 60601-1-11 Edition 2.0 2015-01; IEC 60601-1-11 Edition 2.1 2020-07 CONSOLIDATED VERSION; IEC 60601-2-2 Edition 6.0 2017-03; IEC 60601-2-2 Edition 6.1 2023-02; IEC 60601-2-18:2009-08

IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirements
As written on the certificate · Line 1 (A2LA 6136.01)

IEC 60950-1:2005/AMD2:2013; IEC 62368-1:2018; IEC 62368-1 Ed. 4 2023-05; IEC 60601-1:1988/AMD2:1995; IEC 60601-1:2005+A1:2012; IEC 60601-1:2005+A1:2012+A2:2020; ES60601-1:2005/(R)2012 and A1:2012 C1:2009/(R)2012 and A2:2010/(R)2012 (Consolidated Text); IEC 60601-1-4:1996/AMD1:1999; IEC 60601-1-6:2010+A1:2013+A2:2020; IEC 60601-1-6 Edition 3.1 2013-10; IEC 60601-1-6 Edition 3.2 2020-07 CONSOLIDATED VERSION; IEC 60601-1-8:2006+A1:2012+A2:2020; IEC 60601-1-8 Edition 2.1 2012-11; IEC 60601-1-8 Edition 2.2 2020-07 CONSOLIDATED VERSION; IEC 60601-1-11:2015+A1:2020; IEC 60601-1-11 Edition 2.0 2015-01; IEC 60601-1-11 Edition 2.1 2020-07 CONSOLIDATED VERSION; IEC 60601-2-2 Edition 6.0 2017-03; IEC 60601-2-2 Edition 6.1 2023-02; IEC 60601-2-18:2009-08

Scope as published by A2LA

3 lines
A2LA

ISO/IEC 17025

Active

6136.01

The scope document we hold says it was valid until 2026-06-30. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.

View scope

Accredited scope, certificate 6136.01

LineDisciplineMethodMatrixRange
1electricalIEC 60950-1:2005/AMD2:2013; IEC 62368-1:2018; IEC 62368-1 Ed. 4 2023-05; IEC 60601-1:1988/AMD2:1995; IEC 60601-1:2005+A1:2012; IEC 60601-1:2005+A1:2012+A2:2020; ES60601-1:2005/(R)2012 and A1:2012 C1:2009/(R)2012 and A2:2010/(R)2012 (Consolidated Text); IEC 60601-1-4:1996/AMD1:1999; IEC 60601-1-6:2010+A1:2013+A2:2020; IEC 60601-1-6 Edition 3.1 2013-10; IEC 60601-1-6 Edition 3.2 2020-07 CONSOLIDATED VERSION; IEC 60601-1-8:2006+A1:2012+A2:2020; IEC 60601-1-8 Edition 2.1 2012-11; IEC 60601-1-8 Edition 2.2 2020-07 CONSOLIDATED VERSION; IEC 60601-1-11:2015+A1:2020; IEC 60601-1-11 Edition 2.0 2015-01; IEC 60601-1-11 Edition 2.1 2020-07 CONSOLIDATED VERSION; IEC 60601-2-2 Edition 6.0 2017-03; IEC 60601-2-2 Edition 6.1 2023-02; IEC 60601-2-18:2009-08Medical equipment, electrical safety and EMC-
2electricalIEC 60601-2-64:2014-09; IEC 60601-2-68 Edition 1.0 2014-09; IEC 61010-1:2010+A1:2016; IEC 61010-1 Edition 3.1 2017-01; IEC 61010-2-010:2019; IEC 61010-2-051:2018; IEC 61010-2-101:2018; IEC 60601-1-6 Edition 3.2 2020-07; IEC 60601-1-8 Edition 2.2 2020-07; IEC 60601-1-11 Edition 2.1 2020-07; IEC 60601-2-2 Edition 6.0 2017-03Medical equipment, electrical safety and EMC-
3electrical---

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

suite 211, 94 jackson rd, 94 jackson rd, suite 211, Devens, MA, 01434, US

42.53895, -71.60944

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.