Microwave Factory Calibration Laboratory

815-1, Tatemachi, Hachiouji-shi, Tokyo, 193-0985, Japan, Tokyo, Japan

A2LA|3577.01ISO/IEC 17025Register refreshed 2026-10-09
Certificates
1
Scope items
6
Standards
0
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Microwave Factory Calibration Laboratory?

Claim this profile to keep it accurate.

Register record

A2LARefreshed
3577.01Active

Accredited standards

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Scope as published by A2LA

6 lines
A2LA

ISO/IEC 17025

Active

3577.01

The scope document we hold says it was valid until 2026-05-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.

View scope

Accredited scope, certificate 3577.01

LineDisciplineMethodMatrixRange
1electrical
(A2LA Cert. No. 3577.01) 06/10/2024 Page 1 of 5 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 MICROWAVE FACTORY CALIBRATION LABORATORY 815-1, Tatemachi, Hachiouji-shi, Tokyo 193-0985 JAPAN Mr. Masanori Sakurai Phone: + 81 42 673 3535 sakurai@mwf.co.jp CALIBRATION Valid To: May 31, 2026 Certificate Number: 3577.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 4, 5: I. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 3 (±) Comments DC Voltage – Measure (0 to 32.999) mV (33.000 to 77.999) mV (78.000 to 119.999) mV (120.00 to 329.99) mV (0.330 00 to 1.199 99) V (1.2000 to 11.9999) V (12.000 to 119.999) V (120.00 to 329.99) V 2.5 µV 77 µV/V 35 µV/V 24 µV/V 13 µV/V 11 µV/V 13 µV/V 14 µV/V Agilent 3458A
2electrical
(A2LA Cert. No. 3577.01) 06/10/2024 Page 2 of 5 Parameter/Equipment Range CMC2, 3 (±) Comments DC Voltage – Generate (0 to 32.9999) mV (33.000 to 77.999) mV (78.000 to 119.999) mV (120.000 to 329.999) mV (330.00 to 779.99) mV (0.780 00 to 3.299 99) V (3.3000 to 7.7999) V (7.8000 to 32.9999) V (33.000 to 77.999) V (78.000 to 329.999) V 2.8 µV 84 µV/V 40 µV/V 30 µV/V 15 µV/V 11 µV/V 14 µV/V 11 µV/V 18 µV/V 16 µV/V Fluke 5520A Rsource ≈ 50 Ω Rsource ≈ 50 Ω Rsource ≈ 50 Ω Rsource ≈ 50 Ω Resistance – Measure (0 to 11.9999) Ω (12.000 to 32.9999) Ω (33.000 to 119.999) Ω (120.00 to 1199.99) Ω (1.2000 to 11.9999) kΩ (12.000 to 119.999) kΩ (120.00 to 1100.00) kΩ 0.3 mΩ 86 µΩ/Ω 38 µΩ/Ω 18 µΩ/Ω 18 µΩ/Ω 18 µΩ/Ω 43 µΩ/Ω Agilent 3458A
3electrical
(A2LA Cert. No. 3577.01) 06/10/2024 Page 3 of 5 Parameter/Range Frequency CMC2, 3 (±) Comments AC Voltage – Measure (12.000 to 32.999) mV (33.000 to 119.999) mV (120.00 to 329.99) mV (0.330 00 to 1.199 99) V (1.2000 to 3.2999) V (3.3000 to 11.9999) V (12.000 to 32.999) V (33.000 to 119.999) V (120.00 to 329.99) V (0.600 00 to 1.199 99) V (1.2000 to 3.2000) V 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 100 Hz to 20 kHz 100 Hz to 20 kHz 0.031 % 0.021 % 0.025 % 0.017 % 0.025 % 0.017 % 0.038 % 0.033 % 0.057 % 0.039 % 0.11 % Agilent 3458A 100 mV range, SSM mode 1 V range, SSM mode 10 V range, SSM mode 100 V range, SSM mode 1000 V range, SSM mode 1 V range, ANA mode 10 V range, ANA mode AC Voltage – Generate (1.650 to 47.999) mV (48.000 to 119.99) mV (120.00 to 329.999) mV (330.00 to 779.99) mV (0.780 00 to 3.2999) V (3.3000 to 7.7999) V (7.8000 to 32.9999) V (33.000 to 329.999) V 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 0.032 % 0.028 % 0.018 % 0.027 % 0.019 % 0.027 % 0.019 % 0.021 % Fluke 5520A Test sources < 48 mV are obtained using a 200:1 custom attenuator driven by Fluke 5520A set for 200x the desired voltage, Rsource ≈ 50 Ω Rsource ≈ 50 Ω Rsource ≈ 50 Ω
4electrical--1 to 10000000 Hz
5-
(A2LA Cert. No. 3577.01) 06/10/2024 Page 5 of 5 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC Uncertainty due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 4 This laboratory only offers commercial calibration services on API product families . The scope parameters, ranges and CMC uncertainties are specific to the API product families only. 5 This scope meets A2LA’s P112 Flexible Scope Policy. 6 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
6-ISO/IEC 17025:20 17; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.