JAS METROLOGY S.A.C
Cal. San Hernán 2H 13B1 INT. 4 Urb. Sta Luisa, Los Olivos – Lima,PE, Lima, 051, Peru, Lima, Peru
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at JAS METROLOGY S.A.C?
Claim this profile to keep it accurate.
Register record
- A2LARefreshed
- 7692.01Active
Accredited standards
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Scope as published by A2LA
8 lines
ISO/IEC 17025
Active7692.01
The scope document we hold says it is valid until 2028-01-31.
Accredited scope, certificate 7692.01
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | chemical | (A2LA Cert. No. 7692.01) 01/13/2026 Page 1 of 7
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
JAS METROLOGY S.A.C
Cal. San Hernán 2H 13B1 INT.
4 Urb. Sta Luisa, Los Olivos
Lima, PERÚ 051
Richard Kevin Ayala Puente Phone: 998260341
CALIBRATION
Valid To: January 31, 2028 Certificate Number: 7692.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with A2LA’s R102 – Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations1, 5:
I. Chemical
Parameter/Equipment
Range
CMC2 (±)
Comments
pH Meters3
4 pH
7 pH
10 pH
0.012 pH
0.012 pH
0.012 pH
PC-020 procedure for the
calibration of pH meters, 2nd
edition, 2017, INACAL
Conductivity Meters3
5 µS/cm
10 µS /cm
100 µS /cm
1000 µS /cm
1413 µS /cm
10 000 µS /cm
0.62 µS/cm
0.62 µS/cm
2.1 µS/cm
4.8 µS/cm
5 µS/cm
40 µS/cm
PC-022 procedure for the
calibration of electrolytic
conductivity meters
(conductivity meters), 2nd
edition, 2023, INACAL
Turbidimeters3
1 NTU
5 NTU
20 NTU
100 NTU
500 NTU
1000 NTU
0.061 NTU
0.071 NTU
0.40 NTU
2.0 NTU
4.9 NTU
6.1 NTU
MV-001: procedure for the
calibration of turbidity
meters, rev. 00:2025 JAS | ||
| 2 | mechanical | NMP 004:2007 | - | See scope document |
| 3 | dimensional | PC-011 calibration procedure for non-automatic class I & II balances, 4th edition, 2010 INDECOPI; PC-015 procedure for the calibration of volumetric material of glass and plastic, 5th edition, 2017, INACAL | - | See scope document |
| 4 | dimensional | PC-015 procedure for the calibration of volumetric material of glass and plastic, 5th edition, 2017, INACAL | - | to 2000 mL |
| 5 | dimensional | M6-01-F-01: UV-Vis spectrophotometer calibration guide, rev. 01:2021 INM | - | - |
| 6 | dimensional | PC-018 procedure for the calibration or characterization of isothermal media with air as a thermostatic medium, 2nd edition, 2009, INDECOPI; PC-019 procedure for the calibration of thermostatic baths, 1st edition, 2009, INDECOPI; PC-006 procedure for the calibration of autoclaves, 2nd edition, 2008, INDECOPI; TH-001 procedure for the calibration of digital thermometers 2nd edition, 2019; PC-026 procedure for the calibration of hygrometers & environmental thermometers, 1st edition, 2019, INACAL | - | -30 to 250 °C |
| 7 | - | (A2LA Cert. No. 7692.01) 01/13/2026 Page 7 of 7
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
5 This scope meets A2LA’s P112 Flexible Scope Policy.
6 In the statement of CMC, V is the numerical value of the nominal volume, expressed in the
units indicated. | ||
| 8 | - | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Cal. San Hernán 2H 13B1 INT. 4 Urb. Sta Luisa, Los Olivos – Lima,PE, Lima, 051, Peru, Lima, PE
40.73998, -84.10501
Open in MapsAccreditation data refreshed from the A2LA register on .