FindTestingLabs
Registers refreshed 2026-10-18.See refresh dates
Peru

JAS METROLOGY S.A.C

Cal. San Hernán 2H 13B1 INT. 4 Urb. Sta Luisa, Los Olivos – Lima,PE, Lima, 051, Peru, Lima, Peru

A2LA|7692.01ISO/IEC 17025Register refreshed 2026-10-09
Certificates
1
Scope items
8
Standards
0
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at JAS METROLOGY S.A.C?

Claim this profile to keep it accurate.

Register record

A2LARefreshed
7692.01Active

Accredited standards

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Scope as published by A2LA

8 lines
A2LA

ISO/IEC 17025

Active

7692.01

The scope document we hold says it is valid until 2028-01-31.

View scope

Accredited scope, certificate 7692.01

LineDisciplineMethodMatrixRange
1chemical
(A2LA Cert. No. 7692.01) 01/13/2026 Page 1 of 7 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 JAS METROLOGY S.A.C Cal. San Hernán 2H 13B1 INT. 4 Urb. Sta Luisa, Los Olivos Lima, PERÚ 051 Richard Kevin Ayala Puente Phone: 998260341 CALIBRATION Valid To: January 31, 2028 Certificate Number: 7692.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with A2LA’s R102 – Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations1, 5: I. Chemical Parameter/Equipment Range CMC2 (±) Comments pH Meters3 4 pH 7 pH 10 pH 0.012 pH 0.012 pH 0.012 pH PC-020 procedure for the calibration of pH meters, 2nd edition, 2017, INACAL Conductivity Meters3 5 µS/cm 10 µS /cm 100 µS /cm 1000 µS /cm 1413 µS /cm 10 000 µS /cm 0.62 µS/cm 0.62 µS/cm 2.1 µS/cm 4.8 µS/cm 5 µS/cm 40 µS/cm PC-022 procedure for the calibration of electrolytic conductivity meters (conductivity meters), 2nd edition, 2023, INACAL Turbidimeters3 1 NTU 5 NTU 20 NTU 100 NTU 500 NTU 1000 NTU 0.061 NTU 0.071 NTU 0.40 NTU 2.0 NTU 4.9 NTU 6.1 NTU MV-001: procedure for the calibration of turbidity meters, rev. 00:2025 JAS
2mechanicalNMP 004:2007-See scope document
3dimensionalPC-011 calibration procedure for non-automatic class I & II balances, 4th edition, 2010 INDECOPI; PC-015 procedure for the calibration of volumetric material of glass and plastic, 5th edition, 2017, INACAL-See scope document
4dimensionalPC-015 procedure for the calibration of volumetric material of glass and plastic, 5th edition, 2017, INACAL-to 2000 mL
5dimensionalM6-01-F-01: UV-Vis spectrophotometer calibration guide, rev. 01:2021 INM--
6dimensionalPC-018 procedure for the calibration or characterization of isothermal media with air as a thermostatic medium, 2nd edition, 2009, INDECOPI; PC-019 procedure for the calibration of thermostatic baths, 1st edition, 2009, INDECOPI; PC-006 procedure for the calibration of autoclaves, 2nd edition, 2008, INDECOPI; TH-001 procedure for the calibration of digital thermometers 2nd edition, 2019; PC-026 procedure for the calibration of hygrometers & environmental thermometers, 1st edition, 2019, INACAL--30 to 250 °C
7-
(A2LA Cert. No. 7692.01) 01/13/2026 Page 7 of 7 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 5 This scope meets A2LA’s P112 Flexible Scope Policy. 6 In the statement of CMC, V is the numerical value of the nominal volume, expressed in the units indicated.
8-ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Cal. San Hernán 2H 13B1 INT. 4 Urb. Sta Luisa, Los Olivos – Lima,PE, Lima, 051, Peru, Lima, PE

40.73998, -84.10501

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.