TESMO Sp. z o.o.
ul. Rzeczna 10, 03-794, Warszawa, Poland
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at TESMO Sp. z o.o.?
Claim this profile to keep it accurate.
Register record
- PCARefreshed
- AB 872Active
Certificates and scope
1ISO/IEC 17025
ActiveAB 872
The scope document we hold says it is valid until 2028-01-23.
Accredited scope, certificate AB 872
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | chemical | - | waste gases; general environment (physical factors – noise); air protection equipment; automatic monitoring systems (AMS) | - |
| 2 | environmental | PN-Z-04030-7:1994; PN-EN 16911:2013-07; PN-EN 13284-1:2018-02; PN-ISO 10396:2001; PN-EN 14792:2017-04; PN-EN 14791:2017-04; PN-EN 14789:2017-04; PN-EN 15058:2017-04 | Flue gas | 0.001 to 2500 g/m3; mg/m3; %; m/s |
| 3 | chemical | PN-ISO 10396:2001; PN-EN 12619:2013-05; PN-EN 14790:2017-04; PN-EN 1948-1:2006; PN-EN 13649:2005; PN-EN 1911:2011; PN-EN 13211+AC:2006; PN-Z-04008-4:1999; ISO 15713:2006; PN-EN 14385:2005 | Flue gas | 0.2 to 25 % |
| 4 | environmental | PN-EN 14181:2015-02; PN-Z-04030-7:1994; PN-ISO 10396:2001; PN-EN 12619:2013-05; PN-EN 14792:2017-04; PN-EN 14791:2017-04; PN-EN 15058:2017-04; PN-EN 14789:2017-04; PN-EN 14790:2017-04; PN-EN 1911:2011; ISO 15713:2006 | Air | 0.001 to 1000 g/m3; %; mg/m3; % obj. |
| 5 | chemical | PN-EN ISO 21877:2020-03; PN-EN ISO 21258:2010; PN-Z-04030-7:1994; PN-EN 14385:2005; PN-EN 1948-4+A1:2014-3; PN-EN 1948-1:2006 | Flue gas | 1 to 400 mg/m3 |
| 6 | environmental | PN-EN 14181:2015-02; PN-EN ISO 21877:2020-03; PN-EN ISO 21258:2010; PN-EN 13211+AC:2006; PN-87/M-34129; PN-Z-04030-7:1994; Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) | Automatyczne Systemy Monitoringu (AMS); Urządzenia odpylające gazy odlotowe; Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych | 1 to 135 mg/m3; dB |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Poland
- "Energopomiar"Gliwice · ~272 kmPCAShares 5 accredited methods and materialsEN ISO 21877:2020-03ISO 10396:2001PN-Z-04030-7:1994
- Eurofins SEPO Spółka z ograniczoną odpowiedzialnościąKnurów · ~279 kmPCAShares 5 accredited methods and materialsEN ISO 21877:2020-03ISO 10396:2001PN-Z-04030-7:1994
- Laboratorium Badań i Pomiarów Środowiska EKOLAB Spółka Cywilna Janusz Michalak, Grażyna Felisiak, Anna WysockaŁódź · ~120 kmPCAShares 4 accredited methods and materialsEN ISO 21877:2020-03PN-Z-04030-7:1994Air
- CE2 Tech Consulting M. Dziewa i Wspólnicy Sp. j.Toruń · ~188 kmPCAShares 4 accredited methods and materialsEN ISO 21877:2020-03PN-Z-04030-7:1994Air
- SBB Laboratorium Badań i EkspertyzKatowice · ~267 kmPCAShares 4 accredited methods and materialsEN ISO 21877:2020-03ISO 10396:2001PN-Z-04030-7:1994
Accreditation data refreshed from the PCA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.