- A2LARefreshed
- 7839.01Active
Accredited standards
We have not yet extracted the standard numbers from this lab’s scope document. The scope text we hold is below.
Scope as published by A2LA
6 lines
ISO/IEC 17025
Active7839.01
The scope document we hold says it is valid until 2027-06-30.
Accredited scope, certificate 7839.01
This scope has not been split into individual lines yet. Below is the text of the scope document as published.
Part 1 of 6
(A2LA Cert. No. 7839.01) Revised 06/01/2026 Page 1 of 5 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 AUDIX TECHNOLOGY CORPORATION No. 491 Zhongfu Road Linkou Dist., New Taipei City, 244, TAIWAN (R.O.C) Mr. Leon Liu +886-2-26092133 (#102) leon@audixtech.com ELECTRICAL Valid to: June 30, 2027 Certificate Number: 7839.01 In recognition of the successful completion of the A2LA evaluation process, including an assessment of the organization’s compliance with A2LA’s R214 - Information Technology Accreditation Program requirements, accreditation is granted to this laboratory to perform the following Electrical testing: Test Technology Test Method(s) 1: Emissions Radiated & Conducted (9 kHz to 40 GHz) 47 CFR, FCC Part 15, Subpart B (using ANSI C63.4:2014 2); 47 CFR, FCC Part 18, Subpart C (using MP-5:1986) CISPR 11; EN 55011; EN IEC 55011; BS EN 55011; BS EN IEC 55011; AS/NZS CISPR 11; J55011; CISPR 13; EN 55013; CISPR 14-1; EN 55014-1; EN IEC 55014-1; BS EN 55014-1; BS EN IEC 55014-1; J55014-1; AS/NZS CISPR 14.1; CISPR 15; EN 55015; EN IEC 55015; BS EN 55015; BS EN IEC 55015; CISPRJ 15; J55015; AS CISPR 15; CISPR 32; EN 55032; BS EN 55032; AS/NZS CISPR 32; VCCI-CISPR 32; CISPRJ 32; ICES-001; ICES-003; ICES-005; ICES-GEN; ANSI C63.4 2; FCC OST/MP-5; BETS-7 Harmonic Current IEC 61000-3-2; EN 61000-3-2; EN IEC 61000-3-2; BS EN 61000-3-2; BS EN IEC 61000-3-2; JIS C 61000-3-2; IEC 61000-3-12; EN 61000-3-12; BS EN 61000-3-12 Voltage Changes, Fluctuations, and Flicker IEC 61000-3-3; EN 61000-3-3; BS EN 61000-3-3; IEC 61000-3-11; EN IEC 61000-3-11; BS EN IEC 61000-3-11; AS/NZS 61000-3-11
Part 2 of 6
(A2LA Cert. No. 7839.01) Revised 06/01/2026 Page 2 of 5 Test Technology Test Method(s) 1: Immunity Electrostatic Discharge (ESD) IEC 61000-4-2; EN 61000-4-2; BS EN 61000-4-2 Radiated Immunity IEC 61000-4-3; EN 61000-4-3; EN IEC 61000-4-3; BS EN 61000-4-3; BS EN IEC 61000-4-3 Electrical Fast Transient/Burst Immunity IEC 61000-4-4; EN 61000-4-4; BS EN 61000-4-4 Surge Immunity IEC 61000-4-5; EN 61000-4-5; BS EN 61000-4-5 Conducted Immunity IEC 61000-4-6; EN 61000-4-6; EN IEC 61000-4-6; BS EN 61000-4-6; BS EN IEC 61000-4-6 Power Frequency Magnetic Field Immunity IEC 61000-4-8; EN 61000-4-8; BS EN 61000-4-8 Voltage Dips, Short Interruptions, and Line Voltage Variations Immunity IEC 61000-4-11; EN 61000-4-11; EN IEC 61000-4-11; BS EN 61000-4-11; BS EN IEC 61000-4-11 Oscillatory (Ring) Wave Immunity IEC 61000-4-12; EN 61000-4-12; BS EN 61000-4-12 Radiated Fields in Close Proximity IEC 61000-4-39; EN 61000-4-39; BS EN 61000-4-39 Generic/Product Family/Specific Standards Household Appliances, Electric Tools, and Similar Apparatus CISPR 14-2; EN 55014-2; EN IEC 55014-2; BS EN 55014-2; BS EN IEC 55014-2; AS/NZS CISPR 14.2 Sound and Television Broadcast Receivers and Associated Equipment EN 55020; BS EN 55020 Information Technology Equipment EN 55024; BS EN 55024 Multimedia Equipment EN 55035; BS EN 55035 Alarm System EN 50130-4 Machine Tools EN 50370-1; EN 50370-2 Audio, video, Audio-visual, and Entertainment lighting Control Apparatus EN 55103-1; EN 55103-2 Generic Standards for Residential, Commercial and Light-industrial Environments IEC 61000-6-1; EN 61000-6-1; EN IEC 61000-6-1; BS EN 61000-6-1; BS EN IEC 61000-6-1; IEC 61000-6-3; EN 61000-6-3; EN IEC 61000-6-3; BS EN 61000-6-3; BS EN IEC 61000-6-3; AS/NZS 61000.6.3
Part 3 of 6
(A2LA Cert. No. 7839.01) Revised 06/01/2026 Page 3 of 5 Test Technology Test Method(s) 1: Generic Standards for Industrial Environments IEC 61000-6-2; EN 61000-6-2; EN IEC 61000-6-2; BS EN 61000-6-2; BS EN IEC 61000-6-2; IEC 61000-6-4; EN 61000-6-4; EN IEC 61000-6-4; BS EN 61000-6-4; BS EN IEC 61000-6-4; AS 61000.6.4 Medical Electrical Equipment IEC 60601-1-2; EN 60601-1-2; BS EN 60601-1-2; JIS T 0601-1-2 Equipment for General Lighting Purposes IEC 61547; EN 61547; EN IEC 61547; BS EN 61547; BS EN IEC 61547 Electrical Equipment for Measurement, Control, and Laboratory use IEC 61326-1; EN 61326-1; EN IEC 61326-1; BS EN IEC 61326-1; EN 61326-2-1; EN IEC 61326-2-1; BS EN IEC 61326-2-1; EN 61326-2-2; EN IEC 61326-2-2; BS EN IEC 61326-2-2; EN 61326-2-3; EN IEC 61326-2-3; BS EN IEC 61326-2-3; EN 61326-2-4; EN IEC 61326-2-4; BS EN IEC 61326-2-4; EN 61326-2-5; EN IEC 61326-2-5; BS EN IEC 61326-2-5; EN 61326-2-6; EN IEC 61326-2-6; BS EN IEC 61326-2-6 Uninterruptible Power Systems (UPS) IEC 62040-2; EN 62040-2; EN IEC 62040-2; BS EN IEC 62040-2 Low-voltage Switch Mode Power Supplies IEC 61204-3; EN 61204-3; BS EN IEC 61204-3 Radio equipment and Services ETSI EN 301 489-1; ETSI EN 301 489-3; ETSI EN 301 489-7; ETSI EN 301 489-17; ETSI EN 301 489-19; ETSI EN 301 489-24; ETSI EN 301 489-25; ETSI EN 301 489-33; ETSI EN 301 489-52 Wireless Power Transfer Devices: Category II Equipment RSS-216 (≤ 40 GHz) License-Exempt Radio Apparatus: Category II Equipment RSS-310 RF Exposure SAR, MPE, and APD EN 50360; BS EN 50360; EN 50566; BS EN 50566; EN 50663; BS EN 50663; EN 50665; BS EN 50665;
Text extracted from the accredited scope document. Layout and tables from the original may not carry over; the scope document itself is the authoritative copy.
Accreditation data refreshed from the A2LA register on .