ATEQ PL Sp. z o.o., odštepný závod
Mezírka 775/1, Brno, 602 00, Czech Republic, Brno, Czechia
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at ATEQ PL Sp. z o.o., odštepný závod?
Claim this profile to keep it accurate.
Register record
- A2LARefreshed
- 3049.10Active
Accredited standards
We have not yet extracted the standard numbers from this lab’s scope document. The scope text we hold is below.
Scope as published by A2LA
3 lines
ISO/IEC 17025
Active3049.10
The scope document we hold says it is valid until 2028-06-30.
Accredited scope, certificate 3049.10
This scope has not been split into individual lines yet. Below is the text of the scope document as published.
Part 1 of 3
(A2LA Cert. No. 3049.10) 5/26/2026 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 ATEQ PL SP. Z O.O., ODŠTEPNÝ ZÁVOD Mezírka 775/1 602 00 Brno Czech Republic Bruno Lafosse Phone: +420 549 210 419 CALIBRATION Valid To: June 30, 2028 Certificate Number: 3049.10 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations1, 4: I. Mechanical Parameter/Equipment Range CMC2, 5 (±) Comments Pressure3 – Gas, Measure/Measuring Equipment (-950 to 0) mbar (0 to 500) Pa (0 to 5) kPa (0 to 1000) mbar (0 to 5) bar (0 to 20) bar 0.01 % of rdg + 1.5 mbar 0.1 % of rdg + 1 Pa 0.1 % of rdg + 7.5 Pa 0.8 mbar 0.01 bar 0.03 bar Gauge (vacuum) Gauge ____________________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration.
Part 2 of 3
(A2LA Cert. No. 3049.10) 5/26/2026 Page 2 of 2 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the Calibration and Measurement Capability Uncertainty (CMC) found on t he A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 This scope meets A2LA’s P112 Flexible Scope Policy. 5 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
Part 3 of 3
For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation. Accredited Laboratory A2LA has accredited ATEQ PL SP. Z O.O., ODŠTEPNý ZÁVOD Brno, CZECH REPUBLIC for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories . This laboratory also meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 26th day of May 2026. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 3049.10 Valid to June 30, 2028
Text extracted from the accredited scope document. Layout and tables from the original may not carry over; the scope document itself is the authoritative copy.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.