FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
Germany

Pilz GmbH & Co. KG

Felix-Wankel-Straße 2, 73760, Ostfildern, Germany

DAKKS|D-PL-12033-01-01DAKKS|D-PL-12033-01-00ISO/IEC 17025Register refreshed 2026-09-25
Certificates
2
Scope items
29
Standards
57
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Contact this laboratory

No contact information available

Open DAKKS register entry
Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Pilz GmbH & Co. KG?

Claim this profile to keep it accurate.

Register record

DAKKSRefreshed
D-PL-12033-01-01Active
D-PL-12033-01-00Active

Accredited standards

57

Our reading of the DAKKS scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

IEC 61000 series

IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
As written on the certificate · Line 3 (DAKKS D-PL-12033-01-01)

DIN EN 61000 -4-2:2009 - 12 EN 61000-4-2:2009-03; DIN EN IEC 61000 -4- 3:2021-11 EN IEC 61000-4-3:2020- 10; en 1; EN 61000; EN 61000-4-2

IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity testCertificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 3 (DAKKS D-PL-12033-01-01)

DIN EN 61000 -4-2:2009 - 12 EN 61000-4-2:2009-03; DIN EN IEC 61000 -4- 3:2021-11 EN IEC 61000-4-3:2020- 10; en 1; EN 61000; EN 61000-4-2

As written on the certificate · Line 16 (DAKKS D-PL-12033-01-01)

DIN EN 61000 -4-3:2011 - 04 EN 61000-4-3:2006-05/ A1:2008-02/A2:2010-07; DIN EN 55022:2011 EN 55022:2010; EN 61000; EN 61000-4-3; EN 55022

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
As written on the certificate · Line 4 (DAKKS D-PL-12033-01-01)

DIN EN 61000 -4-4:2013 - 04 EN 61000-4-4: 2012-11; DIN EN 61000 -4-5:2019 - 03; DIN EN 61000 -4-6:2014 - 08 EN 61000-4-6:2014-02; EN 61000; EN 61000-4-4

IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
As written on the certificate · Line 4 (DAKKS D-PL-12033-01-01)

DIN EN 61000 -4-4:2013 - 04 EN 61000-4-4: 2012-11; DIN EN 61000 -4-5:2019 - 03; DIN EN 61000 -4-6:2014 - 08 EN 61000-4-6:2014-02; EN 61000; EN 61000-4-4

IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
As written on the certificate · Line 4 (DAKKS D-PL-12033-01-01)

DIN EN 61000 -4-4:2013 - 04 EN 61000-4-4: 2012-11; DIN EN 61000 -4-5:2019 - 03; DIN EN 61000 -4-6:2014 - 08 EN 61000-4-6:2014-02; EN 61000; EN 61000-4-4

As written on the certificate · Line 15 (DAKKS D-PL-12033-01-01)

DIN EN 301489 -1:2020 - 06 ETSI EN 301 489-1:2019- 11; DIN EN 301489 -3:2023 - 05 ETSI EN 301 489-3:2023- 01 Elektromagnetische Verträglichkeit für Funkeinrichtungen und -dienste - Teil 3; DIN EN 61000 -4-6:2009 - 12 EN 61000-4-6:2009-03; en 1; EN 301489

IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
As written on the certificate · Line 5 (DAKKS D-PL-12033-01-01)

DIN EN 61000 -4-8:2010 - 11 EN 61000-4-8:2010-02; DIN EN 61000 -4-9:2017 - 05 EN 61000-4-9:2016-10; DIN EN IEC 61000 -4-11: 2021-10 EN IEC 61000-4-11: 2020-03; EN 61000; EN 61000-4-8

IEC 61000-4-9Electromagnetic compatibility (EMC) - Part 4-9: Testing and measurement techniques - Impulse magnetic field immunity test
As written on the certificate · Line 5 (DAKKS D-PL-12033-01-01)

DIN EN 61000 -4-8:2010 - 11 EN 61000-4-8:2010-02; DIN EN 61000 -4-9:2017 - 05 EN 61000-4-9:2016-10; DIN EN IEC 61000 -4-11: 2021-10 EN IEC 61000-4-11: 2020-03; EN 61000; EN 61000-4-8

IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
As written on the certificate · Line 5 (DAKKS D-PL-12033-01-01)

DIN EN 61000 -4-8:2010 - 11 EN 61000-4-8:2010-02; DIN EN 61000 -4-9:2017 - 05 EN 61000-4-9:2016-10; DIN EN IEC 61000 -4-11: 2021-10 EN IEC 61000-4-11: 2020-03; EN 61000; EN 61000-4-8

IEC 61000-4-16Name not checked yet
As written on the certificate · Line 6 (DAKKS D-PL-12033-01-01)

DIN EN 61000 -4-16:2016 EN 61000-4-16:2016; DIN EN 61000 -4-29: 2001-10 EN 61000-4-29:2000-11; EN 61000; EN 61000-4-16; EN 61000-4-29

IEC 61000-4-29Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
As written on the certificate · Line 6 (DAKKS D-PL-12033-01-01)

DIN EN 61000 -4-16:2016 EN 61000-4-16:2016; DIN EN 61000 -4-29: 2001-10 EN 61000-4-29:2000-11; EN 61000; EN 61000-4-16; EN 61000-4-29

IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
As written on the certificate · Line 8 (DAKKS D-PL-12033-01-01)

DIN EN 55016 -4-2:2019 - 09 EN 55016-4-2: 2011; DIN EN IEC 61000 -6- 1:2019 EN IEC 61000-6-1:2019; DIN EN IEC 61000 -6-2: 2019-11 EN IEC 61000-6-2:2019- 02; EN 55016; EN 55016-4-2

IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
As written on the certificate · Line 8 (DAKKS D-PL-12033-01-01)

DIN EN 55016 -4-2:2019 - 09 EN 55016-4-2: 2011; DIN EN IEC 61000 -6- 1:2019 EN IEC 61000-6-1:2019; DIN EN IEC 61000 -6-2: 2019-11 EN IEC 61000-6-2:2019- 02; EN 55016; EN 55016-4-2

IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environmentsCertificate says EN 61000-6-3. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 9 (DAKKS D-PL-12033-01-01)

DIN EN IEC 61000 -6- 3:2022 EN IEC 61000-6-3:2021; DIN EN IEC 61000 -6-4: 2020-09 EN IEC 61000-6-4:2019- 09; IEC 61000; IEC 61000-6-3; IEC 61000-6-

IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
As written on the certificate · Line 9 (DAKKS D-PL-12033-01-01)

DIN EN IEC 61000 -6- 3:2022 EN IEC 61000-6-3:2021; DIN EN IEC 61000 -6-4: 2020-09 EN IEC 61000-6-4:2019- 09; IEC 61000; IEC 61000-6-3; IEC 61000-6-

IEC 61000-6-7Name not checked yet
As written on the certificate · Line 10 (DAKKS D-PL-12033-01-01)

DIN EN 61000 -6-7:2015 - 12 EN 61000-6-7: 2015-05; DIN EN 55011/A11:2021 EN 55011:2016/A1:2017 /A11:2020; DIN EN 55032:2016 EN 55032:2015; DIN EN IEC 60947 - 1:2022 EN IEC 60947-1:2021 Niederspannungsschaltgeräte - Teil 1; EN 61000

IEC 60068 series

IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
As written on the certificate · Line 17 (DAKKS D-PL-12033-01-01)

ISO 16750 -4; EN 60068; EN 61373

As written on the certificate · Line 18 (DAKKS D-PL-12033-01-01)

DIN EN 60068 -2-1:2008 - 01 EN 60068-2-1:2007-04 Umgebungseinflüsse - Teil 2 -1; DIN EN 60068 -2-2:2008 - 05 EN 60068-2-2:2007-09 Umgebungseinflüsse - Teil 2 -2; DIN EN 60068 -2-14: 2010-04 EN 60068-2-14:2009-07 Umgebungseinflüsse - Teil 2 -14; DIN EN 60068 -2- 30:2006-06 EN 60068-2-30:2005-12 Umgebungseinflüsse - Teil 2 -30; en 3

IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
As written on the certificate · Line 18 (DAKKS D-PL-12033-01-01)

DIN EN 60068 -2-1:2008 - 01 EN 60068-2-1:2007-04 Umgebungseinflüsse - Teil 2 -1; DIN EN 60068 -2-2:2008 - 05 EN 60068-2-2:2007-09 Umgebungseinflüsse - Teil 2 -2; DIN EN 60068 -2-14: 2010-04 EN 60068-2-14:2009-07 Umgebungseinflüsse - Teil 2 -14; DIN EN 60068 -2- 30:2006-06 EN 60068-2-30:2005-12 Umgebungseinflüsse - Teil 2 -30; en 3

IEC 60068-2-6Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
As written on the certificate · Line 19 (DAKKS D-PL-12033-01-01)

DIN EN IEC 60068 -2-38: 2022-09 EN IEC 60068-2- 38:2021-04 Umgebungseinflüsse - Teil 2 -38; DIN EN 60068 -2-78: 2014-02 EN 60068-2-78:2013-06 Umgebungseinflüsse - Teil 2-78; DIN EN 60068 -2-6: 2008-10 EN 60068-2-6:2008-02 Umgebungseinflüsse - Teil 2 -6; DIN EN 60068 -2-64: 2020-09 EN 60068-2-64:2008- 09/A1:2019 Umgebungseinflüsse - Teil 2 -64; EN 60068

IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
As written on the certificate · Line 18 (DAKKS D-PL-12033-01-01)

DIN EN 60068 -2-1:2008 - 01 EN 60068-2-1:2007-04 Umgebungseinflüsse - Teil 2 -1; DIN EN 60068 -2-2:2008 - 05 EN 60068-2-2:2007-09 Umgebungseinflüsse - Teil 2 -2; DIN EN 60068 -2-14: 2010-04 EN 60068-2-14:2009-07 Umgebungseinflüsse - Teil 2 -14; DIN EN 60068 -2- 30:2006-06 EN 60068-2-30:2005-12 Umgebungseinflüsse - Teil 2 -30; en 3

IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: ShockCertificate says EN 60068-2-27. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 20 (DAKKS D-PL-12033-01-01)

DIN EN 60068 -2-27: 2010-02 EN 60068-2-27:2009-05 Umgebungseinflüsse - Teil 2 -27; DIN EN 60068 -2-31 : 2009-04 EN 60068-2-31:2008-09 Umgebungseinflüsse - Teil 2 -31; DIN EN 60529:2014 - 09; EN 60068; EN 60068-2-27

IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
As written on the certificate · Line 18 (DAKKS D-PL-12033-01-01)

DIN EN 60068 -2-1:2008 - 01 EN 60068-2-1:2007-04 Umgebungseinflüsse - Teil 2 -1; DIN EN 60068 -2-2:2008 - 05 EN 60068-2-2:2007-09 Umgebungseinflüsse - Teil 2 -2; DIN EN 60068 -2-14: 2010-04 EN 60068-2-14:2009-07 Umgebungseinflüsse - Teil 2 -14; DIN EN 60068 -2- 30:2006-06 EN 60068-2-30:2005-12 Umgebungseinflüsse - Teil 2 -30; en 3

IEC 60068-2-31Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens
As written on the certificate · Line 20 (DAKKS D-PL-12033-01-01)

DIN EN 60068 -2-27: 2010-02 EN 60068-2-27:2009-05 Umgebungseinflüsse - Teil 2 -27; DIN EN 60068 -2-31 : 2009-04 EN 60068-2-31:2008-09 Umgebungseinflüsse - Teil 2 -31; DIN EN 60529:2014 - 09; EN 60068; EN 60068-2-27

IEC 60068-2-38Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test
As written on the certificate · Line 19 (DAKKS D-PL-12033-01-01)

DIN EN IEC 60068 -2-38: 2022-09 EN IEC 60068-2- 38:2021-04 Umgebungseinflüsse - Teil 2 -38; DIN EN 60068 -2-78: 2014-02 EN 60068-2-78:2013-06 Umgebungseinflüsse - Teil 2-78; DIN EN 60068 -2-6: 2008-10 EN 60068-2-6:2008-02 Umgebungseinflüsse - Teil 2 -6; DIN EN 60068 -2-64: 2020-09 EN 60068-2-64:2008- 09/A1:2019 Umgebungseinflüsse - Teil 2 -64; EN 60068

IEC 60068-2-64Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidanceCertificate says EN 60068-2-64. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 19 (DAKKS D-PL-12033-01-01)

DIN EN IEC 60068 -2-38: 2022-09 EN IEC 60068-2- 38:2021-04 Umgebungseinflüsse - Teil 2 -38; DIN EN 60068 -2-78: 2014-02 EN 60068-2-78:2013-06 Umgebungseinflüsse - Teil 2-78; DIN EN 60068 -2-6: 2008-10 EN 60068-2-6:2008-02 Umgebungseinflüsse - Teil 2 -6; DIN EN 60068 -2-64: 2020-09 EN 60068-2-64:2008- 09/A1:2019 Umgebungseinflüsse - Teil 2 -64; EN 60068

IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
As written on the certificate · Line 19 (DAKKS D-PL-12033-01-01)

DIN EN IEC 60068 -2-38: 2022-09 EN IEC 60068-2- 38:2021-04 Umgebungseinflüsse - Teil 2 -38; DIN EN 60068 -2-78: 2014-02 EN 60068-2-78:2013-06 Umgebungseinflüsse - Teil 2-78; DIN EN 60068 -2-6: 2008-10 EN 60068-2-6:2008-02 Umgebungseinflüsse - Teil 2 -6; DIN EN 60068 -2-64: 2020-09 EN 60068-2-64:2008- 09/A1:2019 Umgebungseinflüsse - Teil 2 -64; EN 60068

EN

EN 12015Electromagnetic compatibility - Product family standard for lifts, escalators and moving walks - Emission
As written on the certificate · Line 13 (DAKKS D-PL-12033-01-01)

DIN EN 61131 -2:2008 -04; DIN EN 12015:2021 -01 EN 12015:2020-06; DIN EN 12016:2013 -12 EN 12016:2013-08; DIN EN IEC 61800 -3: 2019-04 EN IEC 61800-3:2018-09 Drehzahlveränderbare elektrische Antriebe - Teil 3; EN 61131

EN 12016Name not checked yet
As written on the certificate · Line 13 (DAKKS D-PL-12033-01-01)

DIN EN 61131 -2:2008 -04; DIN EN 12015:2021 -01 EN 12015:2020-06; DIN EN 12016:2013 -12 EN 12016:2013-08; DIN EN IEC 61800 -3: 2019-04 EN IEC 61800-3:2018-09 Drehzahlveränderbare elektrische Antriebe - Teil 3; EN 61131

EN 50121-3-2Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus
As written on the certificate · Line 14 (DAKKS D-PL-12033-01-01)

DIN EN 61800 -5-2:2017 - 11 EN 61800-5-2:2017-04 Elektrische Leistungsantriebssysteme mit einstellbarer Drehzahl - Teil 5-2; DIN EN 50121 -3-2:2017; DIN EN 50121 -4:2017 -11; DIN EN 50155:2018 -05 EN 50155:2017-10; EN 61800-5-2

EN 50121-4Railway applications - Electromagnetic compatibility - Part 4: Emission and immunity of the signalling and telecommunications apparatus
As written on the certificate · Line 14 (DAKKS D-PL-12033-01-01)

DIN EN 61800 -5-2:2017 - 11 EN 61800-5-2:2017-04 Elektrische Leistungsantriebssysteme mit einstellbarer Drehzahl - Teil 5-2; DIN EN 50121 -3-2:2017; DIN EN 50121 -4:2017 -11; DIN EN 50155:2018 -05 EN 50155:2017-10; EN 61800-5-2

EN 50124-1Name not checked yet
As written on the certificate · Line 24 (DAKKS D-PL-12033-01-01)

DIN EN 61131 -2:2008 - 04; DIN EN 50124 -1:2017 -12 EN 50124-1:2017-03 Bahnanwendungen - Isolationskoordination - Teil 1; Isolationskoordination - Teil 1; en 4; EN 61131

EN 50125-3Name not checked yet
As written on the certificate · Line 22 (DAKKS D-PL-12033-01-01)

DIN EN 61373:2011 -04 EN 61373:2010-09; DIN EN 50125 -3:2003 - 10; en 5; EN 61373; EN 50125

EN 50155Railway applications - Rolling stock - Electronic equipment
As written on the certificate · Line 14 (DAKKS D-PL-12033-01-01)

DIN EN 61800 -5-2:2017 - 11 EN 61800-5-2:2017-04 Elektrische Leistungsantriebssysteme mit einstellbarer Drehzahl - Teil 5-2; DIN EN 50121 -3-2:2017; DIN EN 50121 -4:2017 -11; DIN EN 50155:2018 -05 EN 50155:2017-10; EN 61800-5-2

As written on the certificate · Line 21 (DAKKS D-PL-12033-01-01)

DIN EN 61131 -2:2008 - 04; DIN EN 50155:2022 -07 EN 50155:2021-07; DIN EN IEC 61496- 1:2021-06 Sicherheit von Maschinen - Berührungslos wirkende Schutzeinrichtungen - Teil 1; DIN EN 60947 -5-3:2014 - 12 EN 60947-5-3:2013-11 Niederspannungsschaltgeräte - Teil 5-3; ISO 16750 -4:2010 -04 Straßenfahrzeuge - Umgebungsbedingungen und Prüfungen von elektrischer und elektronischer Ausrüstung - Teil 4: Klimatische Beanspruchung Kapitel 5

As written on the certificate · Line 25 (DAKKS D-PL-12033-01-01)

DIN EN 50155:2022 -06 EN 50155:2021-07; DIN EN 61010 -1:2020 -03 EN 61010-1:2010; DIN EN IEC 60947 -1: 2022-03 EN IEC 60947-1:2021-02 Niederspannungsschaltgeräte - Teil 1; Isolationsprüfung SEB IEC 61010 -1:2010 -06; Isolationseigenschaften SEB DIN EN IEC 60947 -1: 2022-03 EN IEC 60947-1:2021-02 Niederspannungsschaltgeräte - Teil 1

EN 61000Name not checked yet
As written on the certificate · Line 4 (DAKKS D-PL-12033-01-01)

DIN EN 61000 -4-4:2013 - 04 EN 61000-4-4: 2012-11; DIN EN 61000 -4-5:2019 - 03; DIN EN 61000 -4-6:2014 - 08 EN 61000-4-6:2014-02; EN 61000; EN 61000-4-4

As written on the certificate · Line 5 (DAKKS D-PL-12033-01-01)

DIN EN 61000 -4-8:2010 - 11 EN 61000-4-8:2010-02; DIN EN 61000 -4-9:2017 - 05 EN 61000-4-9:2016-10; DIN EN IEC 61000 -4-11: 2021-10 EN IEC 61000-4-11: 2020-03; EN 61000; EN 61000-4-8

As written on the certificate · Line 6 (DAKKS D-PL-12033-01-01)

DIN EN 61000 -4-16:2016 EN 61000-4-16:2016; DIN EN 61000 -4-29: 2001-10 EN 61000-4-29:2000-11; EN 61000; EN 61000-4-16; EN 61000-4-29

As written on the certificate · Line 10 (DAKKS D-PL-12033-01-01)

DIN EN 61000 -6-7:2015 - 12 EN 61000-6-7: 2015-05; DIN EN 55011/A11:2021 EN 55011:2016/A1:2017 /A11:2020; DIN EN 55032:2016 EN 55032:2015; DIN EN IEC 60947 - 1:2022 EN IEC 60947-1:2021 Niederspannungsschaltgeräte - Teil 1; EN 61000

As written on the certificate · Line 16 (DAKKS D-PL-12033-01-01)

DIN EN 61000 -4-3:2011 - 04 EN 61000-4-3:2006-05/ A1:2008-02/A2:2010-07; DIN EN 55022:2011 EN 55022:2010; EN 61000; EN 61000-4-3; EN 55022

IEC

IEC 60204-1Safety of machinery - Electrical equipment of machines - Part 1: General requirements
As written on the certificate · Line 27 (DAKKS D-PL-12033-01-01)

DIN EN 60204 -1:2019 -06 EN 60204-1:2018-09 Sicherheit von Maschinen - Elektrische Ausrüstung von Maschinen - Teil 1; EN 60204; EN 60204-1; IEC 60204; IEC 60204-1

IEC 60529Degrees of protection provided by enclosures (IP Code)Certificate says EN 60529. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 20 (DAKKS D-PL-12033-01-01)

DIN EN 60068 -2-27: 2010-02 EN 60068-2-27:2009-05 Umgebungseinflüsse - Teil 2 -27; DIN EN 60068 -2-31 : 2009-04 EN 60068-2-31:2008-09 Umgebungseinflüsse - Teil 2 -31; DIN EN 60529:2014 - 09; EN 60068; EN 60068-2-27

As written on the certificate · Line 23 (DAKKS D-PL-12033-01-01)

DIN EN IEC 60664 -1: 2022 07 EN IEC 60664-1:2020-07 /AC:2020-12; DIN EN 60529:2014 - 09; en 4; EN 60664-1; EN 60529

IEC 60664-1Name not checked yet
As written on the certificate · Line 23 (DAKKS D-PL-12033-01-01)

DIN EN IEC 60664 -1: 2022 07 EN IEC 60664-1:2020-07 /AC:2020-12; DIN EN 60529:2014 - 09; en 4; EN 60664-1; EN 60529

IEC 61010-1Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
As written on the certificate · Line 25 (DAKKS D-PL-12033-01-01)

DIN EN 50155:2022 -06 EN 50155:2021-07; DIN EN 61010 -1:2020 -03 EN 61010-1:2010; DIN EN IEC 60947 -1: 2022-03 EN IEC 60947-1:2021-02 Niederspannungsschaltgeräte - Teil 1; Isolationsprüfung SEB IEC 61010 -1:2010 -06; Isolationseigenschaften SEB DIN EN IEC 60947 -1: 2022-03 EN IEC 60947-1:2021-02 Niederspannungsschaltgeräte - Teil 1

IEC 61131-2Name not checked yet
As written on the certificate · Line 13 (DAKKS D-PL-12033-01-01)

DIN EN 61131 -2:2008 -04; DIN EN 12015:2021 -01 EN 12015:2020-06; DIN EN 12016:2013 -12 EN 12016:2013-08; DIN EN IEC 61800 -3: 2019-04 EN IEC 61800-3:2018-09 Drehzahlveränderbare elektrische Antriebe - Teil 3; EN 61131

As written on the certificate · Line 21 (DAKKS D-PL-12033-01-01)

DIN EN 61131 -2:2008 - 04; DIN EN 50155:2022 -07 EN 50155:2021-07; DIN EN IEC 61496- 1:2021-06 Sicherheit von Maschinen - Berührungslos wirkende Schutzeinrichtungen - Teil 1; DIN EN 60947 -5-3:2014 - 12 EN 60947-5-3:2013-11 Niederspannungsschaltgeräte - Teil 5-3; ISO 16750 -4:2010 -04 Straßenfahrzeuge - Umgebungsbedingungen und Prüfungen von elektrischer und elektronischer Ausrüstung - Teil 4: Klimatische Beanspruchung Kapitel 5

As written on the certificate · Line 24 (DAKKS D-PL-12033-01-01)

DIN EN 61131 -2:2008 - 04; DIN EN 50124 -1:2017 -12 EN 50124-1:2017-03 Bahnanwendungen - Isolationskoordination - Teil 1; Isolationskoordination - Teil 1; en 4; EN 61131

IEC 61326-3-1Name not checked yet
As written on the certificate · Line 12 (DAKKS D-PL-12033-01-01)

DIN EN 60947 -5-3:2014 EN 60947-5-3:2013 Niederspannungsschaltgeräte - Teil 5-3; DIN EN 61326 -3-1:2018 - 04 EN 61326-3-1:2017-07; DIN EN IEC 61496 -1: 2021-06 EN IEC 61496-1:2020-09 Sicherheit von Maschinen - Berührungslos wirkende Schutzeinrichtungen - Teil 1; EN 60947; EN 60947-5-3

IEC 61373Railway applications - Rolling stock equipment - Shock and vibration tests
As written on the certificate · Line 17 (DAKKS D-PL-12033-01-01)

ISO 16750 -4; EN 60068; EN 61373

As written on the certificate · Line 22 (DAKKS D-PL-12033-01-01)

DIN EN 61373:2011 -04 EN 61373:2010-09; DIN EN 50125 -3:2003 - 10; en 5; EN 61373; EN 50125

IEC 61496-1Name not checked yet
As written on the certificate · Line 12 (DAKKS D-PL-12033-01-01)

DIN EN 60947 -5-3:2014 EN 60947-5-3:2013 Niederspannungsschaltgeräte - Teil 5-3; DIN EN 61326 -3-1:2018 - 04 EN 61326-3-1:2017-07; DIN EN IEC 61496 -1: 2021-06 EN IEC 61496-1:2020-09 Sicherheit von Maschinen - Berührungslos wirkende Schutzeinrichtungen - Teil 1; EN 60947; EN 60947-5-3

As written on the certificate · Line 21 (DAKKS D-PL-12033-01-01)

DIN EN 61131 -2:2008 - 04; DIN EN 50155:2022 -07 EN 50155:2021-07; DIN EN IEC 61496- 1:2021-06 Sicherheit von Maschinen - Berührungslos wirkende Schutzeinrichtungen - Teil 1; DIN EN 60947 -5-3:2014 - 12 EN 60947-5-3:2013-11 Niederspannungsschaltgeräte - Teil 5-3; ISO 16750 -4:2010 -04 Straßenfahrzeuge - Umgebungsbedingungen und Prüfungen von elektrischer und elektronischer Ausrüstung - Teil 4: Klimatische Beanspruchung Kapitel 5

IEC 60947 series

IEC 60947-1Name not checked yet
As written on the certificate · Line 10 (DAKKS D-PL-12033-01-01)

DIN EN 61000 -6-7:2015 - 12 EN 61000-6-7: 2015-05; DIN EN 55011/A11:2021 EN 55011:2016/A1:2017 /A11:2020; DIN EN 55032:2016 EN 55032:2015; DIN EN IEC 60947 - 1:2022 EN IEC 60947-1:2021 Niederspannungsschaltgeräte - Teil 1; EN 61000

As written on the certificate · Line 25 (DAKKS D-PL-12033-01-01)

DIN EN 50155:2022 -06 EN 50155:2021-07; DIN EN 61010 -1:2020 -03 EN 61010-1:2010; DIN EN IEC 60947 -1: 2022-03 EN IEC 60947-1:2021-02 Niederspannungsschaltgeräte - Teil 1; Isolationsprüfung SEB IEC 61010 -1:2010 -06; Isolationseigenschaften SEB DIN EN IEC 60947 -1: 2022-03 EN IEC 60947-1:2021-02 Niederspannungsschaltgeräte - Teil 1

IEC 60947-5-1Name not checked yet
As written on the certificate · Line 11 (DAKKS D-PL-12033-01-01)

DIN EN 60947 -5-1:2018 EN 60947-5-1:2017; DIN EN IEC 60947 -5- 2:2021 EN IEC 60947-5-2:2020 Niederspannungsschaltgeräte - Teil 5-2; DIN EN IEC 6 0947 -5- 2:2023 EN IEC 60947-5-2:2020; EN 60947; EN 60947-5-1

As written on the certificate · Line 26 (DAKKS D-PL-12033-01-01)

DIN EN 60947 -5-1:2018 - 03 EN 60947-5-1:2017-12; DIN EN IEC 60947 -5-2: 2021-04 EN IEC 60947-5-2:2020- 03 Niederspannungsschaltgeräte - Teil 5-2; DIN EN 61800 -5-1:2017 - 11 EN 61800-5-1:2007/ A1:2017 Elektrische Leistungsantriebssysteme mit einstellbarer Drehzahl - Teil 5-1; Isolationseigenschaften SEB IEC 60947 -5-2:2019 -10 Low -voltage switchgear and controlgear - Part 5-2: Control circuit devices and switching elements - Proximity switches Nur Ab schnitt 7; Isolationseigenschaften SEB DIN EN IEC 60947 -5-2: 2021-04 EN IEC 60947-5-2:2020- 03 Niederspannungsschaltgeräte - Teil 5-2

IEC 60947-5-2Name not checked yet
As written on the certificate · Line 11 (DAKKS D-PL-12033-01-01)

DIN EN 60947 -5-1:2018 EN 60947-5-1:2017; DIN EN IEC 60947 -5- 2:2021 EN IEC 60947-5-2:2020 Niederspannungsschaltgeräte - Teil 5-2; DIN EN IEC 6 0947 -5- 2:2023 EN IEC 60947-5-2:2020; EN 60947; EN 60947-5-1

As written on the certificate · Line 26 (DAKKS D-PL-12033-01-01)

DIN EN 60947 -5-1:2018 - 03 EN 60947-5-1:2017-12; DIN EN IEC 60947 -5-2: 2021-04 EN IEC 60947-5-2:2020- 03 Niederspannungsschaltgeräte - Teil 5-2; DIN EN 61800 -5-1:2017 - 11 EN 61800-5-1:2007/ A1:2017 Elektrische Leistungsantriebssysteme mit einstellbarer Drehzahl - Teil 5-1; Isolationseigenschaften SEB IEC 60947 -5-2:2019 -10 Low -voltage switchgear and controlgear - Part 5-2: Control circuit devices and switching elements - Proximity switches Nur Ab schnitt 7; Isolationseigenschaften SEB DIN EN IEC 60947 -5-2: 2021-04 EN IEC 60947-5-2:2020- 03 Niederspannungsschaltgeräte - Teil 5-2

IEC 60947-5-3Name not checked yet
As written on the certificate · Line 12 (DAKKS D-PL-12033-01-01)

DIN EN 60947 -5-3:2014 EN 60947-5-3:2013 Niederspannungsschaltgeräte - Teil 5-3; DIN EN 61326 -3-1:2018 - 04 EN 61326-3-1:2017-07; DIN EN IEC 61496 -1: 2021-06 EN IEC 61496-1:2020-09 Sicherheit von Maschinen - Berührungslos wirkende Schutzeinrichtungen - Teil 1; EN 60947; EN 60947-5-3

As written on the certificate · Line 21 (DAKKS D-PL-12033-01-01)

DIN EN 61131 -2:2008 - 04; DIN EN 50155:2022 -07 EN 50155:2021-07; DIN EN IEC 61496- 1:2021-06 Sicherheit von Maschinen - Berührungslos wirkende Schutzeinrichtungen - Teil 1; DIN EN 60947 -5-3:2014 - 12 EN 60947-5-3:2013-11 Niederspannungsschaltgeräte - Teil 5-3; ISO 16750 -4:2010 -04 Straßenfahrzeuge - Umgebungsbedingungen und Prüfungen von elektrischer und elektronischer Ausrüstung - Teil 4: Klimatische Beanspruchung Kapitel 5

CISPR

CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurementCertificate says EN 55011. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 10 (DAKKS D-PL-12033-01-01)

DIN EN 61000 -6-7:2015 - 12 EN 61000-6-7: 2015-05; DIN EN 55011/A11:2021 EN 55011:2016/A1:2017 /A11:2020; DIN EN 55032:2016 EN 55032:2015; DIN EN IEC 60947 - 1:2022 EN IEC 60947-1:2021 Niederspannungsschaltgeräte - Teil 1; EN 61000

CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurementCertificate says EN 55022. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 16 (DAKKS D-PL-12033-01-01)

DIN EN 61000 -4-3:2011 - 04 EN 61000-4-3:2006-05/ A1:2008-02/A2:2010-07; DIN EN 55022:2011 EN 55022:2010; EN 61000; EN 61000-4-3; EN 55022

CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirementsCertificate says EN 55032. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 10 (DAKKS D-PL-12033-01-01)

DIN EN 61000 -6-7:2015 - 12 EN 61000-6-7: 2015-05; DIN EN 55011/A11:2021 EN 55011:2016/A1:2017 /A11:2020; DIN EN 55032:2016 EN 55032:2015; DIN EN IEC 60947 - 1:2022 EN IEC 60947-1:2021 Niederspannungsschaltgeräte - Teil 1; EN 61000

CISPR 16 series

CISPR 16-1-2Name not checked yetCertificate says EN 55016-1-2. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 7 (DAKKS D-PL-12033-01-01)

DIN EN 55016 -1-2:2019 - 10 EN 55016-1-2:2014; DIN EN 55016 -2-1:2019 - 10 EN 55016-2-1: 2017-10; EN 55016; EN 55016-1-2; EN 55016-2-1

CISPR 16-2-1Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurementsCertificate says EN 55016-2-1. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 7 (DAKKS D-PL-12033-01-01)

DIN EN 55016 -1-2:2019 - 10 EN 55016-1-2:2014; DIN EN 55016 -2-1:2019 - 10 EN 55016-2-1: 2017-10; EN 55016; EN 55016-1-2; EN 55016-2-1

CISPR 16-4-2Name not checked yetCertificate says EN 55016-4-2. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 8 (DAKKS D-PL-12033-01-01)

DIN EN 55016 -4-2:2019 - 09 EN 55016-4-2: 2011; DIN EN IEC 61000 -6- 1:2019 EN IEC 61000-6-1:2019; DIN EN IEC 61000 -6-2: 2019-11 EN IEC 61000-6-2:2019- 02; EN 55016; EN 55016-4-2

IEC 61800 series

IEC 61800-3Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods for PDS and machine tools
As written on the certificate · Line 13 (DAKKS D-PL-12033-01-01)

DIN EN 61131 -2:2008 -04; DIN EN 12015:2021 -01 EN 12015:2020-06; DIN EN 12016:2013 -12 EN 12016:2013-08; DIN EN IEC 61800 -3: 2019-04 EN IEC 61800-3:2018-09 Drehzahlveränderbare elektrische Antriebe - Teil 3; EN 61131

IEC 61800-5-1Name not checked yet
As written on the certificate · Line 26 (DAKKS D-PL-12033-01-01)

DIN EN 60947 -5-1:2018 - 03 EN 60947-5-1:2017-12; DIN EN IEC 60947 -5-2: 2021-04 EN IEC 60947-5-2:2020- 03 Niederspannungsschaltgeräte - Teil 5-2; DIN EN 61800 -5-1:2017 - 11 EN 61800-5-1:2007/ A1:2017 Elektrische Leistungsantriebssysteme mit einstellbarer Drehzahl - Teil 5-1; Isolationseigenschaften SEB IEC 60947 -5-2:2019 -10 Low -voltage switchgear and controlgear - Part 5-2: Control circuit devices and switching elements - Proximity switches Nur Ab schnitt 7; Isolationseigenschaften SEB DIN EN IEC 60947 -5-2: 2021-04 EN IEC 60947-5-2:2020- 03 Niederspannungsschaltgeräte - Teil 5-2

IEC 61800-5-2Name not checked yet
As written on the certificate · Line 14 (DAKKS D-PL-12033-01-01)

DIN EN 61800 -5-2:2017 - 11 EN 61800-5-2:2017-04 Elektrische Leistungsantriebssysteme mit einstellbarer Drehzahl - Teil 5-2; DIN EN 50121 -3-2:2017; DIN EN 50121 -4:2017 -11; DIN EN 50155:2018 -05 EN 50155:2017-10; EN 61800-5-2

Other standards

ETSI EN 301 489-1Name not checked yet
As written on the certificate · Line 15 (DAKKS D-PL-12033-01-01)

DIN EN 301489 -1:2020 - 06 ETSI EN 301 489-1:2019- 11; DIN EN 301489 -3:2023 - 05 ETSI EN 301 489-3:2023- 01 Elektromagnetische Verträglichkeit für Funkeinrichtungen und -dienste - Teil 3; DIN EN 61000 -4-6:2009 - 12 EN 61000-4-6:2009-03; en 1; EN 301489

ETSI EN 301 489-3Name not checked yet
As written on the certificate · Line 15 (DAKKS D-PL-12033-01-01)

DIN EN 301489 -1:2020 - 06 ETSI EN 301 489-1:2019- 11; DIN EN 301489 -3:2023 - 05 ETSI EN 301 489-3:2023- 01 Elektromagnetische Verträglichkeit für Funkeinrichtungen und -dienste - Teil 3; DIN EN 61000 -4-6:2009 - 12 EN 61000-4-6:2009-03; en 1; EN 301489

ISO 16750-4Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 4: Climatic loads
As written on the certificate · Line 17 (DAKKS D-PL-12033-01-01)

ISO 16750 -4; EN 60068; EN 61373

As written on the certificate · Line 21 (DAKKS D-PL-12033-01-01)

DIN EN 61131 -2:2008 - 04; DIN EN 50155:2022 -07 EN 50155:2021-07; DIN EN IEC 61496- 1:2021-06 Sicherheit von Maschinen - Berührungslos wirkende Schutzeinrichtungen - Teil 1; DIN EN 60947 -5-3:2014 - 12 EN 60947-5-3:2013-11 Niederspannungsschaltgeräte - Teil 5-3; ISO 16750 -4:2010 -04 Straßenfahrzeuge - Umgebungsbedingungen und Prüfungen von elektrischer und elektronischer Ausrüstung - Teil 4: Klimatische Beanspruchung Kapitel 5

Scope as published by DAKKS

29 lines
DAKKS

ISO/IEC 17025

Active

D-PL-12033-01-01

View scope
DAKKS

ISO/IEC 17025

Active

D-PL-12033-01-00

View scope

Location

Felix-Wankel-Straße 2, Ostfildern, 73760, DE

48.71435, 9.30703

Open in Maps

Accreditation data refreshed from the DAKKS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.