Visional Technology,

Flexipark Free Zone Building A8, San Rafael de Alajuela, 20108, Costa Rica, San Rafael de Alajuela, Costa Rica

A2LA|4111.02ISO/IEC 17025Register refreshed 2026-10-09
Certificates
1
Scope items
6
Standards
0
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Visional Technology,?

Claim this profile to keep it accurate.

Register record

A2LARefreshed
4111.02Active

Accredited standards

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Scope as published by A2LA

6 lines
A2LA

ISO/IEC 17025

Active

4111.02

The scope document we hold says it is valid until 2027-07-31.

View scope

Accredited scope, certificate 4111.02

LineDisciplineMethodMatrixRange
1dimensional--to 758 mm
2dimensional--to 1000 mm
3dimensional
(A2LA Cert. No. 4111.02) 8/26/2025 Page 3 of 5 Parameter/Equipment Range CMC2, 4 (±) Comments Length Standards Up to 12 inch Up to 758 mm (2.0 + 0.91L) μin (0.52 + 0.000 67L) μm Labmaster universal (ULM), CMM, vision system Micrometers Up to 1 inch (1 to 2) inch (2.8 + 0.3L) µin (14 + 1L ) µin Gage blocks Calipers Up to 24 inch (140 + 0.25L) µin Gage blocks Spheres Size Form Up to 25 mm Up to 25 mm 0.43 μm 0.13 μm CMM with comparison to calibrated standard, Labmaster Universal (ULM) Cylindrical Gages Plain Pin and Plug Gages Plain Ring Gages Up to 4 inch Up to 7 inch 4.0 μin 11 μin Labmaster universal (ULM), master gage blocks Thread Wires (1 to 120) TPI (0.2 to 10) Pitch 7.8 µin 0.20 µm Labmaster universal (ULM), master gage blocks Steel Rulers Up to 640 mm (3.9 + 0.0022L) μm Vision measurement system Computer Tomography Systems - CT Machines Length Measurement Error (E) Sphere Distance Deviation (SD) Probing Error Size (PS) Probing Error Form (PF) Measuring volume with a space of diagonal < 205 mm 1.5 μm 0.8 μm 0.6 μm 0.9 μm Sphere array reference, master sphere
4dimensional--to 2 inch
5dimensional
(A2LA Cert. No. 4111.02) 8/26/2025 Page 5 of 5 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the Calibration and Measurement Capability Uncertainty (CMC) found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the uncertainty introduced by the item being calibrated, (e.g. , resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in millimeters (metric units) or inches (imperial units); D is the numerical value of the nominal diameter of the device measured in millimeters (metric units) or inches (imperial units) ; and A is the nominal numerical value of an angle measured in decimal degrees. 5 This scope meets A2LA’s P112 Flexible Scope Policy. 6 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for the types of dimensional tests listed above and is considered equivalent to that of a calibration. 7 Repeatability of the Unit Under Test has not been utilized in the calculation of the CMC value for this measurement parameter.
6-ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.