FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
Germany

HIMA Paul Hildebrandt GmbH Abteilung EDS, Team TLab

Albert-Bassermann-Straße 28, 68782, Brühl, Germany

DAKKS|D-PL-21561-01-01ISO/IEC 17025Register refreshed 2026-09-25
Certificates
1
Scope items
10
Standards
37
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Contact this laboratory

No contact information available

Open DAKKS register entry
Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at HIMA Paul Hildebrandt GmbH Abteilung EDS, Team TLab?

Claim this profile to keep it accurate.

Register record

DAKKSRefreshed
D-PL-21561-01-01Active

Accredited standards

37

Our reading of the DAKKS scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

IEC 61000 series

IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
As written on the certificate · Line 3 (DAKKS D-PL-21561-01-01)

DIN EN 61000-4-2:2009-12; VDE 0847-4-2:2009-12; DIN EN 61000-4-4; VDE 0847-4-4:2013-04; DIN EN 61000-4-5; VDE 0847-4-5:2019-03; DIN EN 61000-4-6; VDE 0847-4-6:2014-08; DIN EN 61000-4-8; VDE 0847-4-8:2010-11; DIN EN 61000-4-9; VDE 0847-4-9:2017-05

As written on the certificate · Line 5 (DAKKS D-PL-21561-01-01)

DIN EN IEC 61000 -6-2; VDE 0839-6-2:2019-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 61000 -6-7; VDE 0839-6-7:2015-12; DIN EN 61000-4-29; DIN EN IEC 61000 -6-4; VDE 0839-6-4:2020-09; DIN EN 55016-2-1; DIN EN 54 -2/A1:2007 -01; DIN EN 298:2012 -11; DIN EN 50121 -3-2; VDE 0115-121-3-2:2017-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 50121 -4; VDE 0115-121-4:2017-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 50130 -4; VDE 0830-1-4: 2015-04

As written on the certificate · Line 6 (DAKKS D-PL-21561-01-01)

DIN EN 50155; VDE 0115-200:2018-05; DIN EN 50121-3-2; VDE 0115-121-3-2:2017-11; DIN EN 50270; VDE 0843-30:2015-10; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 61000-4-29; DIN IEC 60533:2021-05; DIN EN 61131-2; VDE 0411-500:2008-04; DIN EN 61131-6; VDE 0411-506:2013-10; DIN EN 61326-1; VDE 0843-20-1:2013-07; DIN EN IEC 61326-1:2022-11

As written on the certificate · Line 7 (DAKKS D-PL-21561-01-01)

DIN EN 61326 -3-1; VDE 0843-20-3-1:2018-04; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 61000-4-29; DIN EN IEC 61326 -3-2; VDE 0843-20-3-2:2019-10; DIN EN 61800 -3; VDE 0160-103:2019-04; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DNVGL -CG -0339:2019 -12; Lloyd’s Register Type Approval System Test Specification Number 1 May 2018; Bureau Veritas (BV) NR 467.C1 DT R12 E January 2020; NE 21; Edition : 2017 -08 -01; DIN EN 61000-4-3

IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity testCertificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 7 (DAKKS D-PL-21561-01-01)

DIN EN 61326 -3-1; VDE 0843-20-3-1:2018-04; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 61000-4-29; DIN EN IEC 61326 -3-2; VDE 0843-20-3-2:2019-10; DIN EN 61800 -3; VDE 0160-103:2019-04; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DNVGL -CG -0339:2019 -12; Lloyd’s Register Type Approval System Test Specification Number 1 May 2018; Bureau Veritas (BV) NR 467.C1 DT R12 E January 2020; NE 21; Edition : 2017 -08 -01; DIN EN 61000-4-3

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
As written on the certificate · Line 3 (DAKKS D-PL-21561-01-01)

DIN EN 61000-4-2:2009-12; VDE 0847-4-2:2009-12; DIN EN 61000-4-4; VDE 0847-4-4:2013-04; DIN EN 61000-4-5; VDE 0847-4-5:2019-03; DIN EN 61000-4-6; VDE 0847-4-6:2014-08; DIN EN 61000-4-8; VDE 0847-4-8:2010-11; DIN EN 61000-4-9; VDE 0847-4-9:2017-05

As written on the certificate · Line 5 (DAKKS D-PL-21561-01-01)

DIN EN IEC 61000 -6-2; VDE 0839-6-2:2019-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 61000 -6-7; VDE 0839-6-7:2015-12; DIN EN 61000-4-29; DIN EN IEC 61000 -6-4; VDE 0839-6-4:2020-09; DIN EN 55016-2-1; DIN EN 54 -2/A1:2007 -01; DIN EN 298:2012 -11; DIN EN 50121 -3-2; VDE 0115-121-3-2:2017-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 50121 -4; VDE 0115-121-4:2017-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 50130 -4; VDE 0830-1-4: 2015-04

As written on the certificate · Line 6 (DAKKS D-PL-21561-01-01)

DIN EN 50155; VDE 0115-200:2018-05; DIN EN 50121-3-2; VDE 0115-121-3-2:2017-11; DIN EN 50270; VDE 0843-30:2015-10; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 61000-4-29; DIN IEC 60533:2021-05; DIN EN 61131-2; VDE 0411-500:2008-04; DIN EN 61131-6; VDE 0411-506:2013-10; DIN EN 61326-1; VDE 0843-20-1:2013-07; DIN EN IEC 61326-1:2022-11

As written on the certificate · Line 7 (DAKKS D-PL-21561-01-01)

DIN EN 61326 -3-1; VDE 0843-20-3-1:2018-04; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 61000-4-29; DIN EN IEC 61326 -3-2; VDE 0843-20-3-2:2019-10; DIN EN 61800 -3; VDE 0160-103:2019-04; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DNVGL -CG -0339:2019 -12; Lloyd’s Register Type Approval System Test Specification Number 1 May 2018; Bureau Veritas (BV) NR 467.C1 DT R12 E January 2020; NE 21; Edition : 2017 -08 -01; DIN EN 61000-4-3

IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
As written on the certificate · Line 3 (DAKKS D-PL-21561-01-01)

DIN EN 61000-4-2:2009-12; VDE 0847-4-2:2009-12; DIN EN 61000-4-4; VDE 0847-4-4:2013-04; DIN EN 61000-4-5; VDE 0847-4-5:2019-03; DIN EN 61000-4-6; VDE 0847-4-6:2014-08; DIN EN 61000-4-8; VDE 0847-4-8:2010-11; DIN EN 61000-4-9; VDE 0847-4-9:2017-05

As written on the certificate · Line 5 (DAKKS D-PL-21561-01-01)

DIN EN IEC 61000 -6-2; VDE 0839-6-2:2019-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 61000 -6-7; VDE 0839-6-7:2015-12; DIN EN 61000-4-29; DIN EN IEC 61000 -6-4; VDE 0839-6-4:2020-09; DIN EN 55016-2-1; DIN EN 54 -2/A1:2007 -01; DIN EN 298:2012 -11; DIN EN 50121 -3-2; VDE 0115-121-3-2:2017-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 50121 -4; VDE 0115-121-4:2017-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 50130 -4; VDE 0830-1-4: 2015-04

As written on the certificate · Line 6 (DAKKS D-PL-21561-01-01)

DIN EN 50155; VDE 0115-200:2018-05; DIN EN 50121-3-2; VDE 0115-121-3-2:2017-11; DIN EN 50270; VDE 0843-30:2015-10; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 61000-4-29; DIN IEC 60533:2021-05; DIN EN 61131-2; VDE 0411-500:2008-04; DIN EN 61131-6; VDE 0411-506:2013-10; DIN EN 61326-1; VDE 0843-20-1:2013-07; DIN EN IEC 61326-1:2022-11

As written on the certificate · Line 7 (DAKKS D-PL-21561-01-01)

DIN EN 61326 -3-1; VDE 0843-20-3-1:2018-04; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 61000-4-29; DIN EN IEC 61326 -3-2; VDE 0843-20-3-2:2019-10; DIN EN 61800 -3; VDE 0160-103:2019-04; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DNVGL -CG -0339:2019 -12; Lloyd’s Register Type Approval System Test Specification Number 1 May 2018; Bureau Veritas (BV) NR 467.C1 DT R12 E January 2020; NE 21; Edition : 2017 -08 -01; DIN EN 61000-4-3

IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
As written on the certificate · Line 3 (DAKKS D-PL-21561-01-01)

DIN EN 61000-4-2:2009-12; VDE 0847-4-2:2009-12; DIN EN 61000-4-4; VDE 0847-4-4:2013-04; DIN EN 61000-4-5; VDE 0847-4-5:2019-03; DIN EN 61000-4-6; VDE 0847-4-6:2014-08; DIN EN 61000-4-8; VDE 0847-4-8:2010-11; DIN EN 61000-4-9; VDE 0847-4-9:2017-05

As written on the certificate · Line 5 (DAKKS D-PL-21561-01-01)

DIN EN IEC 61000 -6-2; VDE 0839-6-2:2019-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 61000 -6-7; VDE 0839-6-7:2015-12; DIN EN 61000-4-29; DIN EN IEC 61000 -6-4; VDE 0839-6-4:2020-09; DIN EN 55016-2-1; DIN EN 54 -2/A1:2007 -01; DIN EN 298:2012 -11; DIN EN 50121 -3-2; VDE 0115-121-3-2:2017-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 50121 -4; VDE 0115-121-4:2017-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 50130 -4; VDE 0830-1-4: 2015-04

As written on the certificate · Line 6 (DAKKS D-PL-21561-01-01)

DIN EN 50155; VDE 0115-200:2018-05; DIN EN 50121-3-2; VDE 0115-121-3-2:2017-11; DIN EN 50270; VDE 0843-30:2015-10; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 61000-4-29; DIN IEC 60533:2021-05; DIN EN 61131-2; VDE 0411-500:2008-04; DIN EN 61131-6; VDE 0411-506:2013-10; DIN EN 61326-1; VDE 0843-20-1:2013-07; DIN EN IEC 61326-1:2022-11

As written on the certificate · Line 7 (DAKKS D-PL-21561-01-01)

DIN EN 61326 -3-1; VDE 0843-20-3-1:2018-04; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 61000-4-29; DIN EN IEC 61326 -3-2; VDE 0843-20-3-2:2019-10; DIN EN 61800 -3; VDE 0160-103:2019-04; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DNVGL -CG -0339:2019 -12; Lloyd’s Register Type Approval System Test Specification Number 1 May 2018; Bureau Veritas (BV) NR 467.C1 DT R12 E January 2020; NE 21; Edition : 2017 -08 -01; DIN EN 61000-4-3

IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
As written on the certificate · Line 3 (DAKKS D-PL-21561-01-01)

DIN EN 61000-4-2:2009-12; VDE 0847-4-2:2009-12; DIN EN 61000-4-4; VDE 0847-4-4:2013-04; DIN EN 61000-4-5; VDE 0847-4-5:2019-03; DIN EN 61000-4-6; VDE 0847-4-6:2014-08; DIN EN 61000-4-8; VDE 0847-4-8:2010-11; DIN EN 61000-4-9; VDE 0847-4-9:2017-05

As written on the certificate · Line 5 (DAKKS D-PL-21561-01-01)

DIN EN IEC 61000 -6-2; VDE 0839-6-2:2019-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 61000 -6-7; VDE 0839-6-7:2015-12; DIN EN 61000-4-29; DIN EN IEC 61000 -6-4; VDE 0839-6-4:2020-09; DIN EN 55016-2-1; DIN EN 54 -2/A1:2007 -01; DIN EN 298:2012 -11; DIN EN 50121 -3-2; VDE 0115-121-3-2:2017-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 50121 -4; VDE 0115-121-4:2017-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 50130 -4; VDE 0830-1-4: 2015-04

As written on the certificate · Line 6 (DAKKS D-PL-21561-01-01)

DIN EN 50155; VDE 0115-200:2018-05; DIN EN 50121-3-2; VDE 0115-121-3-2:2017-11; DIN EN 50270; VDE 0843-30:2015-10; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 61000-4-29; DIN IEC 60533:2021-05; DIN EN 61131-2; VDE 0411-500:2008-04; DIN EN 61131-6; VDE 0411-506:2013-10; DIN EN 61326-1; VDE 0843-20-1:2013-07; DIN EN IEC 61326-1:2022-11

As written on the certificate · Line 7 (DAKKS D-PL-21561-01-01)

DIN EN 61326 -3-1; VDE 0843-20-3-1:2018-04; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 61000-4-29; DIN EN IEC 61326 -3-2; VDE 0843-20-3-2:2019-10; DIN EN 61800 -3; VDE 0160-103:2019-04; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DNVGL -CG -0339:2019 -12; Lloyd’s Register Type Approval System Test Specification Number 1 May 2018; Bureau Veritas (BV) NR 467.C1 DT R12 E January 2020; NE 21; Edition : 2017 -08 -01; DIN EN 61000-4-3

IEC 61000-4-9Electromagnetic compatibility (EMC) - Part 4-9: Testing and measurement techniques - Impulse magnetic field immunity test
As written on the certificate · Line 3 (DAKKS D-PL-21561-01-01)

DIN EN 61000-4-2:2009-12; VDE 0847-4-2:2009-12; DIN EN 61000-4-4; VDE 0847-4-4:2013-04; DIN EN 61000-4-5; VDE 0847-4-5:2019-03; DIN EN 61000-4-6; VDE 0847-4-6:2014-08; DIN EN 61000-4-8; VDE 0847-4-8:2010-11; DIN EN 61000-4-9; VDE 0847-4-9:2017-05

IEC 61000-4-18Name not checked yet
As written on the certificate · Line 4 (DAKKS D-PL-21561-01-01)

DIN EN 61000 -4-18; VDE 0847-4-18:2007-12; DIN EN 61000 -4-18/A1; VDE 0847-4-18/A1:2011-04; DIN EN 61000 -4-29; VDE 0847-4-29:2001-10; DIN EN 55016 -2-1; VDE 0877-16-2-1: 2019-11; DIN EN IEC 61000 -6-1; VDE 0839-6-1:2019-11

IEC 61000-4-29Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
As written on the certificate · Line 4 (DAKKS D-PL-21561-01-01)

DIN EN 61000 -4-18; VDE 0847-4-18:2007-12; DIN EN 61000 -4-18/A1; VDE 0847-4-18/A1:2011-04; DIN EN 61000 -4-29; VDE 0847-4-29:2001-10; DIN EN 55016 -2-1; VDE 0877-16-2-1: 2019-11; DIN EN IEC 61000 -6-1; VDE 0839-6-1:2019-11

As written on the certificate · Line 5 (DAKKS D-PL-21561-01-01)

DIN EN IEC 61000 -6-2; VDE 0839-6-2:2019-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 61000 -6-7; VDE 0839-6-7:2015-12; DIN EN 61000-4-29; DIN EN IEC 61000 -6-4; VDE 0839-6-4:2020-09; DIN EN 55016-2-1; DIN EN 54 -2/A1:2007 -01; DIN EN 298:2012 -11; DIN EN 50121 -3-2; VDE 0115-121-3-2:2017-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 50121 -4; VDE 0115-121-4:2017-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 50130 -4; VDE 0830-1-4: 2015-04

As written on the certificate · Line 6 (DAKKS D-PL-21561-01-01)

DIN EN 50155; VDE 0115-200:2018-05; DIN EN 50121-3-2; VDE 0115-121-3-2:2017-11; DIN EN 50270; VDE 0843-30:2015-10; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 61000-4-29; DIN IEC 60533:2021-05; DIN EN 61131-2; VDE 0411-500:2008-04; DIN EN 61131-6; VDE 0411-506:2013-10; DIN EN 61326-1; VDE 0843-20-1:2013-07; DIN EN IEC 61326-1:2022-11

As written on the certificate · Line 7 (DAKKS D-PL-21561-01-01)

DIN EN 61326 -3-1; VDE 0843-20-3-1:2018-04; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 61000-4-29; DIN EN IEC 61326 -3-2; VDE 0843-20-3-2:2019-10; DIN EN 61800 -3; VDE 0160-103:2019-04; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DNVGL -CG -0339:2019 -12; Lloyd’s Register Type Approval System Test Specification Number 1 May 2018; Bureau Veritas (BV) NR 467.C1 DT R12 E January 2020; NE 21; Edition : 2017 -08 -01; DIN EN 61000-4-3

IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
As written on the certificate · Line 4 (DAKKS D-PL-21561-01-01)

DIN EN 61000 -4-18; VDE 0847-4-18:2007-12; DIN EN 61000 -4-18/A1; VDE 0847-4-18/A1:2011-04; DIN EN 61000 -4-29; VDE 0847-4-29:2001-10; DIN EN 55016 -2-1; VDE 0877-16-2-1: 2019-11; DIN EN IEC 61000 -6-1; VDE 0839-6-1:2019-11

IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
As written on the certificate · Line 5 (DAKKS D-PL-21561-01-01)

DIN EN IEC 61000 -6-2; VDE 0839-6-2:2019-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 61000 -6-7; VDE 0839-6-7:2015-12; DIN EN 61000-4-29; DIN EN IEC 61000 -6-4; VDE 0839-6-4:2020-09; DIN EN 55016-2-1; DIN EN 54 -2/A1:2007 -01; DIN EN 298:2012 -11; DIN EN 50121 -3-2; VDE 0115-121-3-2:2017-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 50121 -4; VDE 0115-121-4:2017-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 50130 -4; VDE 0830-1-4: 2015-04

IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
As written on the certificate · Line 5 (DAKKS D-PL-21561-01-01)

DIN EN IEC 61000 -6-2; VDE 0839-6-2:2019-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 61000 -6-7; VDE 0839-6-7:2015-12; DIN EN 61000-4-29; DIN EN IEC 61000 -6-4; VDE 0839-6-4:2020-09; DIN EN 55016-2-1; DIN EN 54 -2/A1:2007 -01; DIN EN 298:2012 -11; DIN EN 50121 -3-2; VDE 0115-121-3-2:2017-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 50121 -4; VDE 0115-121-4:2017-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 50130 -4; VDE 0830-1-4: 2015-04

IEC 61000-6-7Name not checked yet
As written on the certificate · Line 5 (DAKKS D-PL-21561-01-01)

DIN EN IEC 61000 -6-2; VDE 0839-6-2:2019-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 61000 -6-7; VDE 0839-6-7:2015-12; DIN EN 61000-4-29; DIN EN IEC 61000 -6-4; VDE 0839-6-4:2020-09; DIN EN 55016-2-1; DIN EN 54 -2/A1:2007 -01; DIN EN 298:2012 -11; DIN EN 50121 -3-2; VDE 0115-121-3-2:2017-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 50121 -4; VDE 0115-121-4:2017-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 50130 -4; VDE 0830-1-4: 2015-04

EN

EN 54-2Name not checked yet
As written on the certificate · Line 5 (DAKKS D-PL-21561-01-01)

DIN EN IEC 61000 -6-2; VDE 0839-6-2:2019-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 61000 -6-7; VDE 0839-6-7:2015-12; DIN EN 61000-4-29; DIN EN IEC 61000 -6-4; VDE 0839-6-4:2020-09; DIN EN 55016-2-1; DIN EN 54 -2/A1:2007 -01; DIN EN 298:2012 -11; DIN EN 50121 -3-2; VDE 0115-121-3-2:2017-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 50121 -4; VDE 0115-121-4:2017-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 50130 -4; VDE 0830-1-4: 2015-04

As written on the certificate · Line 8 (DAKKS D-PL-21561-01-01)

DIN EN 60068 -2-1; VDE 0468-2-1:2008-01; DIN EN 60068 -2-2; VDE 0468-2-2:2008-05; DIN EN 60068 -2-14 ; VDE 0468-2-14:2010-04; DIN EN 60068 -2-30:2006 -06; DIN EN 60068 -2-78 ; VDE 0468-2-78:2014-02; DIN EN 61800 -2; VDE 0160-102:2016-08; DIN EN 61800 -5-1; VDE 0160-105-1:2017-11; DIN EN 54 -2/A1:2007 -01; DIN EN 298:2012 -11; DIN EN 50155 ; VDE 0115-200:2018-05

EN 298Name not checked yet
As written on the certificate · Line 5 (DAKKS D-PL-21561-01-01)

DIN EN IEC 61000 -6-2; VDE 0839-6-2:2019-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 61000 -6-7; VDE 0839-6-7:2015-12; DIN EN 61000-4-29; DIN EN IEC 61000 -6-4; VDE 0839-6-4:2020-09; DIN EN 55016-2-1; DIN EN 54 -2/A1:2007 -01; DIN EN 298:2012 -11; DIN EN 50121 -3-2; VDE 0115-121-3-2:2017-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 50121 -4; VDE 0115-121-4:2017-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 50130 -4; VDE 0830-1-4: 2015-04

As written on the certificate · Line 8 (DAKKS D-PL-21561-01-01)

DIN EN 60068 -2-1; VDE 0468-2-1:2008-01; DIN EN 60068 -2-2; VDE 0468-2-2:2008-05; DIN EN 60068 -2-14 ; VDE 0468-2-14:2010-04; DIN EN 60068 -2-30:2006 -06; DIN EN 60068 -2-78 ; VDE 0468-2-78:2014-02; DIN EN 61800 -2; VDE 0160-102:2016-08; DIN EN 61800 -5-1; VDE 0160-105-1:2017-11; DIN EN 54 -2/A1:2007 -01; DIN EN 298:2012 -11; DIN EN 50155 ; VDE 0115-200:2018-05

EN 50121-3-2Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus
As written on the certificate · Line 5 (DAKKS D-PL-21561-01-01)

DIN EN IEC 61000 -6-2; VDE 0839-6-2:2019-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 61000 -6-7; VDE 0839-6-7:2015-12; DIN EN 61000-4-29; DIN EN IEC 61000 -6-4; VDE 0839-6-4:2020-09; DIN EN 55016-2-1; DIN EN 54 -2/A1:2007 -01; DIN EN 298:2012 -11; DIN EN 50121 -3-2; VDE 0115-121-3-2:2017-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 50121 -4; VDE 0115-121-4:2017-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 50130 -4; VDE 0830-1-4: 2015-04

As written on the certificate · Line 6 (DAKKS D-PL-21561-01-01)

DIN EN 50155; VDE 0115-200:2018-05; DIN EN 50121-3-2; VDE 0115-121-3-2:2017-11; DIN EN 50270; VDE 0843-30:2015-10; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 61000-4-29; DIN IEC 60533:2021-05; DIN EN 61131-2; VDE 0411-500:2008-04; DIN EN 61131-6; VDE 0411-506:2013-10; DIN EN 61326-1; VDE 0843-20-1:2013-07; DIN EN IEC 61326-1:2022-11

EN 50121-4Railway applications - Electromagnetic compatibility - Part 4: Emission and immunity of the signalling and telecommunications apparatus
As written on the certificate · Line 5 (DAKKS D-PL-21561-01-01)

DIN EN IEC 61000 -6-2; VDE 0839-6-2:2019-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 61000 -6-7; VDE 0839-6-7:2015-12; DIN EN 61000-4-29; DIN EN IEC 61000 -6-4; VDE 0839-6-4:2020-09; DIN EN 55016-2-1; DIN EN 54 -2/A1:2007 -01; DIN EN 298:2012 -11; DIN EN 50121 -3-2; VDE 0115-121-3-2:2017-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 50121 -4; VDE 0115-121-4:2017-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 50130 -4; VDE 0830-1-4: 2015-04

EN 50130-4Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems
As written on the certificate · Line 5 (DAKKS D-PL-21561-01-01)

DIN EN IEC 61000 -6-2; VDE 0839-6-2:2019-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 61000 -6-7; VDE 0839-6-7:2015-12; DIN EN 61000-4-29; DIN EN IEC 61000 -6-4; VDE 0839-6-4:2020-09; DIN EN 55016-2-1; DIN EN 54 -2/A1:2007 -01; DIN EN 298:2012 -11; DIN EN 50121 -3-2; VDE 0115-121-3-2:2017-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 50121 -4; VDE 0115-121-4:2017-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 50130 -4; VDE 0830-1-4: 2015-04

EN 50155Railway applications - Rolling stock - Electronic equipment
As written on the certificate · Line 6 (DAKKS D-PL-21561-01-01)

DIN EN 50155; VDE 0115-200:2018-05; DIN EN 50121-3-2; VDE 0115-121-3-2:2017-11; DIN EN 50270; VDE 0843-30:2015-10; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 61000-4-29; DIN IEC 60533:2021-05; DIN EN 61131-2; VDE 0411-500:2008-04; DIN EN 61131-6; VDE 0411-506:2013-10; DIN EN 61326-1; VDE 0843-20-1:2013-07; DIN EN IEC 61326-1:2022-11

As written on the certificate · Line 8 (DAKKS D-PL-21561-01-01)

DIN EN 60068 -2-1; VDE 0468-2-1:2008-01; DIN EN 60068 -2-2; VDE 0468-2-2:2008-05; DIN EN 60068 -2-14 ; VDE 0468-2-14:2010-04; DIN EN 60068 -2-30:2006 -06; DIN EN 60068 -2-78 ; VDE 0468-2-78:2014-02; DIN EN 61800 -2; VDE 0160-102:2016-08; DIN EN 61800 -5-1; VDE 0160-105-1:2017-11; DIN EN 54 -2/A1:2007 -01; DIN EN 298:2012 -11; DIN EN 50155 ; VDE 0115-200:2018-05

As written on the certificate · Line 9 (DAKKS D-PL-21561-01-01)

DIN EN 50155; VDE 0115-200:2022-06; DIN EN 61131 -2; VDE 0411-500:2008-04; DIN EN 61131 -6; VDE 0411-506:2013-10; DNVGL -CG -0339:2019 -12; Lloyd’s Register Type Approval System Test Specification Number 1 December 2020; Bureau Veritas (BV) NR 467.C1 DT R12 E January 2020; DIN EN 50155 ; VDE 0115-200:2018-05; DIN EN 50155; VDE 0115-200:2022-06; DIN IEC 60060 -1; VDE 0432-1:2014-09

EN 50270Name not checked yet
As written on the certificate · Line 6 (DAKKS D-PL-21561-01-01)

DIN EN 50155; VDE 0115-200:2018-05; DIN EN 50121-3-2; VDE 0115-121-3-2:2017-11; DIN EN 50270; VDE 0843-30:2015-10; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 61000-4-29; DIN IEC 60533:2021-05; DIN EN 61131-2; VDE 0411-500:2008-04; DIN EN 61131-6; VDE 0411-506:2013-10; DIN EN 61326-1; VDE 0843-20-1:2013-07; DIN EN IEC 61326-1:2022-11

IEC

IEC 60060-1Name not checked yet
As written on the certificate · Line 9 (DAKKS D-PL-21561-01-01)

DIN EN 50155; VDE 0115-200:2022-06; DIN EN 61131 -2; VDE 0411-500:2008-04; DIN EN 61131 -6; VDE 0411-506:2013-10; DNVGL -CG -0339:2019 -12; Lloyd’s Register Type Approval System Test Specification Number 1 December 2020; Bureau Veritas (BV) NR 467.C1 DT R12 E January 2020; DIN EN 50155 ; VDE 0115-200:2018-05; DIN EN 50155; VDE 0115-200:2022-06; DIN IEC 60060 -1; VDE 0432-1:2014-09

IEC 60533Name not checked yet
As written on the certificate · Line 6 (DAKKS D-PL-21561-01-01)

DIN EN 50155; VDE 0115-200:2018-05; DIN EN 50121-3-2; VDE 0115-121-3-2:2017-11; DIN EN 50270; VDE 0843-30:2015-10; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 61000-4-29; DIN IEC 60533:2021-05; DIN EN 61131-2; VDE 0411-500:2008-04; DIN EN 61131-6; VDE 0411-506:2013-10; DIN EN 61326-1; VDE 0843-20-1:2013-07; DIN EN IEC 61326-1:2022-11

IEC 60950-1Information technology equipment - Safety - Part 1: General requirements
As written on the certificate · Line 10 (DAKKS D-PL-21561-01-01)

DIN EN 60950 -1:2003 -03; DIN EN 61131 -2; VDE 0411 -500:2008-04

IEC 61131-2Name not checked yet
As written on the certificate · Line 6 (DAKKS D-PL-21561-01-01)

DIN EN 50155; VDE 0115-200:2018-05; DIN EN 50121-3-2; VDE 0115-121-3-2:2017-11; DIN EN 50270; VDE 0843-30:2015-10; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 61000-4-29; DIN IEC 60533:2021-05; DIN EN 61131-2; VDE 0411-500:2008-04; DIN EN 61131-6; VDE 0411-506:2013-10; DIN EN 61326-1; VDE 0843-20-1:2013-07; DIN EN IEC 61326-1:2022-11

As written on the certificate · Line 9 (DAKKS D-PL-21561-01-01)

DIN EN 50155; VDE 0115-200:2022-06; DIN EN 61131 -2; VDE 0411-500:2008-04; DIN EN 61131 -6; VDE 0411-506:2013-10; DNVGL -CG -0339:2019 -12; Lloyd’s Register Type Approval System Test Specification Number 1 December 2020; Bureau Veritas (BV) NR 467.C1 DT R12 E January 2020; DIN EN 50155 ; VDE 0115-200:2018-05; DIN EN 50155; VDE 0115-200:2022-06; DIN IEC 60060 -1; VDE 0432-1:2014-09

As written on the certificate · Line 10 (DAKKS D-PL-21561-01-01)

DIN EN 60950 -1:2003 -03; DIN EN 61131 -2; VDE 0411 -500:2008-04

IEC 61131-6Name not checked yet
As written on the certificate · Line 6 (DAKKS D-PL-21561-01-01)

DIN EN 50155; VDE 0115-200:2018-05; DIN EN 50121-3-2; VDE 0115-121-3-2:2017-11; DIN EN 50270; VDE 0843-30:2015-10; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 61000-4-29; DIN IEC 60533:2021-05; DIN EN 61131-2; VDE 0411-500:2008-04; DIN EN 61131-6; VDE 0411-506:2013-10; DIN EN 61326-1; VDE 0843-20-1:2013-07; DIN EN IEC 61326-1:2022-11

As written on the certificate · Line 9 (DAKKS D-PL-21561-01-01)

DIN EN 50155; VDE 0115-200:2022-06; DIN EN 61131 -2; VDE 0411-500:2008-04; DIN EN 61131 -6; VDE 0411-506:2013-10; DNVGL -CG -0339:2019 -12; Lloyd’s Register Type Approval System Test Specification Number 1 December 2020; Bureau Veritas (BV) NR 467.C1 DT R12 E January 2020; DIN EN 50155 ; VDE 0115-200:2018-05; DIN EN 50155; VDE 0115-200:2022-06; DIN IEC 60060 -1; VDE 0432-1:2014-09

IEC 60068 series

IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
As written on the certificate · Line 8 (DAKKS D-PL-21561-01-01)

DIN EN 60068 -2-1; VDE 0468-2-1:2008-01; DIN EN 60068 -2-2; VDE 0468-2-2:2008-05; DIN EN 60068 -2-14 ; VDE 0468-2-14:2010-04; DIN EN 60068 -2-30:2006 -06; DIN EN 60068 -2-78 ; VDE 0468-2-78:2014-02; DIN EN 61800 -2; VDE 0160-102:2016-08; DIN EN 61800 -5-1; VDE 0160-105-1:2017-11; DIN EN 54 -2/A1:2007 -01; DIN EN 298:2012 -11; DIN EN 50155 ; VDE 0115-200:2018-05

IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
As written on the certificate · Line 8 (DAKKS D-PL-21561-01-01)

DIN EN 60068 -2-1; VDE 0468-2-1:2008-01; DIN EN 60068 -2-2; VDE 0468-2-2:2008-05; DIN EN 60068 -2-14 ; VDE 0468-2-14:2010-04; DIN EN 60068 -2-30:2006 -06; DIN EN 60068 -2-78 ; VDE 0468-2-78:2014-02; DIN EN 61800 -2; VDE 0160-102:2016-08; DIN EN 61800 -5-1; VDE 0160-105-1:2017-11; DIN EN 54 -2/A1:2007 -01; DIN EN 298:2012 -11; DIN EN 50155 ; VDE 0115-200:2018-05

IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
As written on the certificate · Line 8 (DAKKS D-PL-21561-01-01)

DIN EN 60068 -2-1; VDE 0468-2-1:2008-01; DIN EN 60068 -2-2; VDE 0468-2-2:2008-05; DIN EN 60068 -2-14 ; VDE 0468-2-14:2010-04; DIN EN 60068 -2-30:2006 -06; DIN EN 60068 -2-78 ; VDE 0468-2-78:2014-02; DIN EN 61800 -2; VDE 0160-102:2016-08; DIN EN 61800 -5-1; VDE 0160-105-1:2017-11; DIN EN 54 -2/A1:2007 -01; DIN EN 298:2012 -11; DIN EN 50155 ; VDE 0115-200:2018-05

IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
As written on the certificate · Line 8 (DAKKS D-PL-21561-01-01)

DIN EN 60068 -2-1; VDE 0468-2-1:2008-01; DIN EN 60068 -2-2; VDE 0468-2-2:2008-05; DIN EN 60068 -2-14 ; VDE 0468-2-14:2010-04; DIN EN 60068 -2-30:2006 -06; DIN EN 60068 -2-78 ; VDE 0468-2-78:2014-02; DIN EN 61800 -2; VDE 0160-102:2016-08; DIN EN 61800 -5-1; VDE 0160-105-1:2017-11; DIN EN 54 -2/A1:2007 -01; DIN EN 298:2012 -11; DIN EN 50155 ; VDE 0115-200:2018-05

IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
As written on the certificate · Line 8 (DAKKS D-PL-21561-01-01)

DIN EN 60068 -2-1; VDE 0468-2-1:2008-01; DIN EN 60068 -2-2; VDE 0468-2-2:2008-05; DIN EN 60068 -2-14 ; VDE 0468-2-14:2010-04; DIN EN 60068 -2-30:2006 -06; DIN EN 60068 -2-78 ; VDE 0468-2-78:2014-02; DIN EN 61800 -2; VDE 0160-102:2016-08; DIN EN 61800 -5-1; VDE 0160-105-1:2017-11; DIN EN 54 -2/A1:2007 -01; DIN EN 298:2012 -11; DIN EN 50155 ; VDE 0115-200:2018-05

IEC 61326 series

IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
As written on the certificate · Line 6 (DAKKS D-PL-21561-01-01)

DIN EN 50155; VDE 0115-200:2018-05; DIN EN 50121-3-2; VDE 0115-121-3-2:2017-11; DIN EN 50270; VDE 0843-30:2015-10; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 61000-4-29; DIN IEC 60533:2021-05; DIN EN 61131-2; VDE 0411-500:2008-04; DIN EN 61131-6; VDE 0411-506:2013-10; DIN EN 61326-1; VDE 0843-20-1:2013-07; DIN EN IEC 61326-1:2022-11

IEC 61326-3-1Name not checked yet
As written on the certificate · Line 7 (DAKKS D-PL-21561-01-01)

DIN EN 61326 -3-1; VDE 0843-20-3-1:2018-04; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 61000-4-29; DIN EN IEC 61326 -3-2; VDE 0843-20-3-2:2019-10; DIN EN 61800 -3; VDE 0160-103:2019-04; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DNVGL -CG -0339:2019 -12; Lloyd’s Register Type Approval System Test Specification Number 1 May 2018; Bureau Veritas (BV) NR 467.C1 DT R12 E January 2020; NE 21; Edition : 2017 -08 -01; DIN EN 61000-4-3

IEC 61326-3-2Name not checked yet
As written on the certificate · Line 7 (DAKKS D-PL-21561-01-01)

DIN EN 61326 -3-1; VDE 0843-20-3-1:2018-04; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 61000-4-29; DIN EN IEC 61326 -3-2; VDE 0843-20-3-2:2019-10; DIN EN 61800 -3; VDE 0160-103:2019-04; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DNVGL -CG -0339:2019 -12; Lloyd’s Register Type Approval System Test Specification Number 1 May 2018; Bureau Veritas (BV) NR 467.C1 DT R12 E January 2020; NE 21; Edition : 2017 -08 -01; DIN EN 61000-4-3

IEC 61800 series

IEC 61800-2Name not checked yet
As written on the certificate · Line 8 (DAKKS D-PL-21561-01-01)

DIN EN 60068 -2-1; VDE 0468-2-1:2008-01; DIN EN 60068 -2-2; VDE 0468-2-2:2008-05; DIN EN 60068 -2-14 ; VDE 0468-2-14:2010-04; DIN EN 60068 -2-30:2006 -06; DIN EN 60068 -2-78 ; VDE 0468-2-78:2014-02; DIN EN 61800 -2; VDE 0160-102:2016-08; DIN EN 61800 -5-1; VDE 0160-105-1:2017-11; DIN EN 54 -2/A1:2007 -01; DIN EN 298:2012 -11; DIN EN 50155 ; VDE 0115-200:2018-05

IEC 61800-3Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods for PDS and machine tools
As written on the certificate · Line 7 (DAKKS D-PL-21561-01-01)

DIN EN 61326 -3-1; VDE 0843-20-3-1:2018-04; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 61000-4-29; DIN EN IEC 61326 -3-2; VDE 0843-20-3-2:2019-10; DIN EN 61800 -3; VDE 0160-103:2019-04; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DNVGL -CG -0339:2019 -12; Lloyd’s Register Type Approval System Test Specification Number 1 May 2018; Bureau Veritas (BV) NR 467.C1 DT R12 E January 2020; NE 21; Edition : 2017 -08 -01; DIN EN 61000-4-3

IEC 61800-5-1Name not checked yet
As written on the certificate · Line 8 (DAKKS D-PL-21561-01-01)

DIN EN 60068 -2-1; VDE 0468-2-1:2008-01; DIN EN 60068 -2-2; VDE 0468-2-2:2008-05; DIN EN 60068 -2-14 ; VDE 0468-2-14:2010-04; DIN EN 60068 -2-30:2006 -06; DIN EN 60068 -2-78 ; VDE 0468-2-78:2014-02; DIN EN 61800 -2; VDE 0160-102:2016-08; DIN EN 61800 -5-1; VDE 0160-105-1:2017-11; DIN EN 54 -2/A1:2007 -01; DIN EN 298:2012 -11; DIN EN 50155 ; VDE 0115-200:2018-05

Other standards

CISPR 16-2-1Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurementsCertificate says EN 55016-2-1. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 4 (DAKKS D-PL-21561-01-01)

DIN EN 61000 -4-18; VDE 0847-4-18:2007-12; DIN EN 61000 -4-18/A1; VDE 0847-4-18/A1:2011-04; DIN EN 61000 -4-29; VDE 0847-4-29:2001-10; DIN EN 55016 -2-1; VDE 0877-16-2-1: 2019-11; DIN EN IEC 61000 -6-1; VDE 0839-6-1:2019-11

As written on the certificate · Line 5 (DAKKS D-PL-21561-01-01)

DIN EN IEC 61000 -6-2; VDE 0839-6-2:2019-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 61000 -6-7; VDE 0839-6-7:2015-12; DIN EN 61000-4-29; DIN EN IEC 61000 -6-4; VDE 0839-6-4:2020-09; DIN EN 55016-2-1; DIN EN 54 -2/A1:2007 -01; DIN EN 298:2012 -11; DIN EN 50121 -3-2; VDE 0115-121-3-2:2017-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 50121 -4; VDE 0115-121-4:2017-11; DIN EN 61000-4-2; DIN EN 61000-4-4; DIN EN 61000-4-5; DIN EN 61000-4-6; DIN EN 61000-4-8; DIN EN 50130 -4; VDE 0830-1-4: 2015-04

Scope as published by DAKKS

10 lines
DAKKS

ISO/IEC 17025

Active

D-PL-21561-01-01

View scope

Location

Albert-Bassermann-Straße 28, Brühl, 68782, DE

49.40752, 8.54123

Open in Maps

Accreditation data refreshed from the DAKKS register on .