FindTestingLabs
Registers refreshed 2026-10-18.See refresh dates
Thailand

ESPEC ENGINEERING (THAILAND) CO.,LTD.

700/860, Amata City Chonburi Industrial Estate, (Phase8), Moo5, Tambol Nongkakha, Amphur Panthong, Chonburi, 20160, Thailand, Chonburi, Thailand

A2LA|5733.01ISO/IEC 17025Register refreshed 2026-10-09
Certificates
1
Scope items
4
Standards
10
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at ESPEC ENGINEERING (THAILAND) CO.,LTD.?

Claim this profile to keep it accurate.

Register record

A2LARefreshed
5733.01Active

Accredited standards

10

Our reading of the A2LA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
As written on the certificate · Line 3 (A2LA 5733.01)

MIL-STD-883; IEC -2-14; ISO 16750-4; IEC 61215-1-1; IEC 60068-2-14; IEC 60068-2-1; IEC 60068-2-2; MIL-STD-810; ISO 9455-17; IEC 60068-2-78; IEC 60068-2-30; IEC 60068-2-38; ISO 12405-4

IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
As written on the certificate · Line 3 (A2LA 5733.01)

MIL-STD-883; IEC -2-14; ISO 16750-4; IEC 61215-1-1; IEC 60068-2-14; IEC 60068-2-1; IEC 60068-2-2; MIL-STD-810; ISO 9455-17; IEC 60068-2-78; IEC 60068-2-30; IEC 60068-2-38; ISO 12405-4

IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
As written on the certificate · Line 3 (A2LA 5733.01)

MIL-STD-883; IEC -2-14; ISO 16750-4; IEC 61215-1-1; IEC 60068-2-14; IEC 60068-2-1; IEC 60068-2-2; MIL-STD-810; ISO 9455-17; IEC 60068-2-78; IEC 60068-2-30; IEC 60068-2-38; ISO 12405-4

IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
As written on the certificate · Line 3 (A2LA 5733.01)

MIL-STD-883; IEC -2-14; ISO 16750-4; IEC 61215-1-1; IEC 60068-2-14; IEC 60068-2-1; IEC 60068-2-2; MIL-STD-810; ISO 9455-17; IEC 60068-2-78; IEC 60068-2-30; IEC 60068-2-38; ISO 12405-4

IEC 60068-2-38Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test
As written on the certificate · Line 3 (A2LA 5733.01)

MIL-STD-883; IEC -2-14; ISO 16750-4; IEC 61215-1-1; IEC 60068-2-14; IEC 60068-2-1; IEC 60068-2-2; MIL-STD-810; ISO 9455-17; IEC 60068-2-78; IEC 60068-2-30; IEC 60068-2-38; ISO 12405-4

IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
As written on the certificate · Line 3 (A2LA 5733.01)

MIL-STD-883; IEC -2-14; ISO 16750-4; IEC 61215-1-1; IEC 60068-2-14; IEC 60068-2-1; IEC 60068-2-2; MIL-STD-810; ISO 9455-17; IEC 60068-2-78; IEC 60068-2-30; IEC 60068-2-38; ISO 12405-4

IEC 61215-1-1Name not checked yet
As written on the certificate · Line 3 (A2LA 5733.01)

MIL-STD-883; IEC -2-14; ISO 16750-4; IEC 61215-1-1; IEC 60068-2-14; IEC 60068-2-1; IEC 60068-2-2; MIL-STD-810; ISO 9455-17; IEC 60068-2-78; IEC 60068-2-30; IEC 60068-2-38; ISO 12405-4

ISO 9455-17Soft soldering fluxes - Test methods - Part 17: Surface insulation resistance comb test and electrochemical migration test of flux residues
As written on the certificate · Line 3 (A2LA 5733.01)

MIL-STD-883; IEC -2-14; ISO 16750-4; IEC 61215-1-1; IEC 60068-2-14; IEC 60068-2-1; IEC 60068-2-2; MIL-STD-810; ISO 9455-17; IEC 60068-2-78; IEC 60068-2-30; IEC 60068-2-38; ISO 12405-4

ISO 12405-4Electrically propelled road vehicles —Test specification for lithium-ion traction battery packs and systems - Part 4: Performance testing
As written on the certificate · Line 3 (A2LA 5733.01)

MIL-STD-883; IEC -2-14; ISO 16750-4; IEC 61215-1-1; IEC 60068-2-14; IEC 60068-2-1; IEC 60068-2-2; MIL-STD-810; ISO 9455-17; IEC 60068-2-78; IEC 60068-2-30; IEC 60068-2-38; ISO 12405-4

ISO 16750-4Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 4: Climatic loads
As written on the certificate · Line 3 (A2LA 5733.01)

MIL-STD-883; IEC -2-14; ISO 16750-4; IEC 61215-1-1; IEC 60068-2-14; IEC 60068-2-1; IEC 60068-2-2; MIL-STD-810; ISO 9455-17; IEC 60068-2-78; IEC 60068-2-30; IEC 60068-2-38; ISO 12405-4

Scope as published by A2LA

4 lines
A2LA

ISO/IEC 17025

Active

5733.01

The scope document we hold says it was valid until 2026-03-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.

View scope

Accredited scope, certificate 5733.01

LineDisciplineMethodMatrixRange
1dimensionalDKD-R5-7 with JTM K 07-See scope document
2-
(A2LA Cert. No. 5733.01) Revised 02/17/2026 Page 2 of 3 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 This scope meets A2LA’s P112 Flexible Scope Policy.
3mechanicalMIL-STD-883; IEC -2-14; ISO 16750-4; IEC 61215-1-1; IEC 60068-2-14; IEC 60068-2-1; IEC 60068-2-2; MIL-STD-810; ISO 9455-17; IEC 60068-2-78; IEC 60068-2-30; IEC 60068-2-38; ISO 12405-4Fasteners-75 to 200 °C
4mechanicalISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.