FindTestingLabs
Registers refreshed 2026-10-18.See refresh dates
Spain

BUREAU VERITAS SUSTAINABLE FUELS MANAGEMENT

Barrio Revilla, 6R, Planta -1 del Edificio EIC del Parque Tecnológico de Ezkerraldea/Meatzaldea, 48500, Abanto Zierbena, Spain

ENAC|1589/LE2949ENAC|1589/LE2950ENAC|1589/LE2951ISO/IEC 17025Register refreshed 2026-10-10
Certificates
3
Scope items
7
Standards
21
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Contact this laboratory

No contact information available

Open ENAC register entry
Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at BUREAU VERITAS SUSTAINABLE FUELS MANAGEMENT?

Claim this profile to keep it accurate.

Register record

ENACRefreshed
1589/LE2949Active
1589/LE2950Active
1589/LE2951Active

Accredited standards

21

Our reading of the ENAC scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

ASTM

ASTM D86Name not checked yet
As written on the certificate · Line 2 (ENAC 1589/LE2950)

ASTM D86; ISO 3405; ASTM D93; ISO 2719; ASTM D6045; ASTM D4737; ISO 4264; ASTM D976; ASTM D4052; ISO 12185; UNE-EN 14104; UNE-EN 116; ASTM D6371

ASTM D93Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester
As written on the certificate · Line 2 (ENAC 1589/LE2950)

ASTM D86; ISO 3405; ASTM D93; ISO 2719; ASTM D6045; ASTM D4737; ISO 4264; ASTM D976; ASTM D4052; ISO 12185; UNE-EN 14104; UNE-EN 116; ASTM D6371

As written on the certificate · Line 3 (ENAC 1589/LE2950)

ASTM D5771; IP 444; UNE-EN 14105; ASTM D93; ISO 2719; UNE-EN 14110; ASTM D6045

ASTM D95Name not checked yet
As written on the certificate · Line 2 (ENAC 1589/LE2949)

ISO 12185; ISO 8754; ASTM D95; ISO 3733

ASTM D976Name not checked yet
As written on the certificate · Line 2 (ENAC 1589/LE2950)

ASTM D86; ISO 3405; ASTM D93; ISO 2719; ASTM D6045; ASTM D4737; ISO 4264; ASTM D976; ASTM D4052; ISO 12185; UNE-EN 14104; UNE-EN 116; ASTM D6371

ASTM D4052Standard Test Method for Density, Relative Density, and API Gravity of Liquids by Digital Density Meter
As written on the certificate · Line 1 (ENAC 1589/LE2950)

UNE-EN ISO/IEC 17025:2017; ASTM D4052; ISO 12185; UNE-EN 116; ASTM D6371; ASTM D5771; IP 444

As written on the certificate · Line 2 (ENAC 1589/LE2950)

ASTM D86; ISO 3405; ASTM D93; ISO 2719; ASTM D6045; ASTM D4737; ISO 4264; ASTM D976; ASTM D4052; ISO 12185; UNE-EN 14104; UNE-EN 116; ASTM D6371

As written on the certificate · Line 1 (ENAC 1589/LE2949)

UNE-EN ISO/IEC 17025:2017; ASTM D4052; ISO 12185; ISO 8754

ASTM D4737Name not checked yet
As written on the certificate · Line 2 (ENAC 1589/LE2950)

ASTM D86; ISO 3405; ASTM D93; ISO 2719; ASTM D6045; ASTM D4737; ISO 4264; ASTM D976; ASTM D4052; ISO 12185; UNE-EN 14104; UNE-EN 116; ASTM D6371

ASTM D5771Name not checked yet
As written on the certificate · Line 1 (ENAC 1589/LE2950)

UNE-EN ISO/IEC 17025:2017; ASTM D4052; ISO 12185; UNE-EN 116; ASTM D6371; ASTM D5771; IP 444

As written on the certificate · Line 3 (ENAC 1589/LE2950)

ASTM D5771; IP 444; UNE-EN 14105; ASTM D93; ISO 2719; UNE-EN 14110; ASTM D6045

ASTM D6045Name not checked yet
As written on the certificate · Line 2 (ENAC 1589/LE2950)

ASTM D86; ISO 3405; ASTM D93; ISO 2719; ASTM D6045; ASTM D4737; ISO 4264; ASTM D976; ASTM D4052; ISO 12185; UNE-EN 14104; UNE-EN 116; ASTM D6371

As written on the certificate · Line 3 (ENAC 1589/LE2950)

ASTM D5771; IP 444; UNE-EN 14105; ASTM D93; ISO 2719; UNE-EN 14110; ASTM D6045

ASTM D6371Name not checked yet
As written on the certificate · Line 1 (ENAC 1589/LE2950)

UNE-EN ISO/IEC 17025:2017; ASTM D4052; ISO 12185; UNE-EN 116; ASTM D6371; ASTM D5771; IP 444

As written on the certificate · Line 2 (ENAC 1589/LE2950)

ASTM D86; ISO 3405; ASTM D93; ISO 2719; ASTM D6045; ASTM D4737; ISO 4264; ASTM D976; ASTM D4052; ISO 12185; UNE-EN 14104; UNE-EN 116; ASTM D6371

ISO

ISO 2719Determination of flash point - Pensky-Martens closed cup method
As written on the certificate · Line 2 (ENAC 1589/LE2950)

ASTM D86; ISO 3405; ASTM D93; ISO 2719; ASTM D6045; ASTM D4737; ISO 4264; ASTM D976; ASTM D4052; ISO 12185; UNE-EN 14104; UNE-EN 116; ASTM D6371

As written on the certificate · Line 3 (ENAC 1589/LE2950)

ASTM D5771; IP 444; UNE-EN 14105; ASTM D93; ISO 2719; UNE-EN 14110; ASTM D6045

ISO 3405Petroleum and related products from natural or synthetic sources - Determination of distillation characteristics at atmospheric pressure
As written on the certificate · Line 2 (ENAC 1589/LE2950)

ASTM D86; ISO 3405; ASTM D93; ISO 2719; ASTM D6045; ASTM D4737; ISO 4264; ASTM D976; ASTM D4052; ISO 12185; UNE-EN 14104; UNE-EN 116; ASTM D6371

ISO 3733Petroleum products and bituminous materials - Determination of water - Distillation method
As written on the certificate · Line 2 (ENAC 1589/LE2949)

ISO 12185; ISO 8754; ASTM D95; ISO 3733

ISO 4264Petroleum products - Calculation of cetane index of middle-distillate fuels by the four variable equation
As written on the certificate · Line 2 (ENAC 1589/LE2950)

ASTM D86; ISO 3405; ASTM D93; ISO 2719; ASTM D6045; ASTM D4737; ISO 4264; ASTM D976; ASTM D4052; ISO 12185; UNE-EN 14104; UNE-EN 116; ASTM D6371

ISO 7507-4Petroleum and liquid petroleum products - Calibration of vertical cylindrical tanks - Part 4: Internal electro-optical distance-ranging method
As written on the certificate · Line 1 (ENAC 1589/LE2951)

ISO 7507-4; UNE-EN ISO/IEC 17025:2017

ISO 8754Petroleum products - Determination of sulfur content - Energy-dispersive X-ray fluorescence spectrometry
As written on the certificate · Line 1 (ENAC 1589/LE2949)

UNE-EN ISO/IEC 17025:2017; ASTM D4052; ISO 12185; ISO 8754

As written on the certificate · Line 2 (ENAC 1589/LE2949)

ISO 12185; ISO 8754; ASTM D95; ISO 3733

ISO 12185Crude petroleum, petroleum products and related products - Determination of density - Laboratory density meter with an oscillating U-tube sensor
As written on the certificate · Line 1 (ENAC 1589/LE2950)

UNE-EN ISO/IEC 17025:2017; ASTM D4052; ISO 12185; UNE-EN 116; ASTM D6371; ASTM D5771; IP 444

As written on the certificate · Line 2 (ENAC 1589/LE2950)

ASTM D86; ISO 3405; ASTM D93; ISO 2719; ASTM D6045; ASTM D4737; ISO 4264; ASTM D976; ASTM D4052; ISO 12185; UNE-EN 14104; UNE-EN 116; ASTM D6371

As written on the certificate · Line 1 (ENAC 1589/LE2949)

UNE-EN ISO/IEC 17025:2017; ASTM D4052; ISO 12185; ISO 8754

As written on the certificate · Line 2 (ENAC 1589/LE2949)

ISO 12185; ISO 8754; ASTM D95; ISO 3733

EN

EN 116Name not checked yet
As written on the certificate · Line 1 (ENAC 1589/LE2950)

UNE-EN ISO/IEC 17025:2017; ASTM D4052; ISO 12185; UNE-EN 116; ASTM D6371; ASTM D5771; IP 444

As written on the certificate · Line 2 (ENAC 1589/LE2950)

ASTM D86; ISO 3405; ASTM D93; ISO 2719; ASTM D6045; ASTM D4737; ISO 4264; ASTM D976; ASTM D4052; ISO 12185; UNE-EN 14104; UNE-EN 116; ASTM D6371

EN 14104Name not checked yet
As written on the certificate · Line 2 (ENAC 1589/LE2950)

ASTM D86; ISO 3405; ASTM D93; ISO 2719; ASTM D6045; ASTM D4737; ISO 4264; ASTM D976; ASTM D4052; ISO 12185; UNE-EN 14104; UNE-EN 116; ASTM D6371

EN 14105Name not checked yet
As written on the certificate · Line 3 (ENAC 1589/LE2950)

ASTM D5771; IP 444; UNE-EN 14105; ASTM D93; ISO 2719; UNE-EN 14110; ASTM D6045

EN 14110Name not checked yet
As written on the certificate · Line 3 (ENAC 1589/LE2950)

ASTM D5771; IP 444; UNE-EN 14105; ASTM D93; ISO 2719; UNE-EN 14110; ASTM D6045

EN 14275Name not checked yet
As written on the certificate · Line 4 (ENAC 1589/LE2950)

UNE-EN 14275

Scope as published by ENAC

7 lines
ENAC

ISO/IEC 17025

Active

1589/LE2949

View scope

Accredited scope, certificate 1589/LE2949

LineDisciplineMethodMatrixRange
1chemicalUNE-EN ISO/IEC 17025:2017; ASTM D4052; ISO 12185; ISO 8754Gasóleos; Diesel Oil0.01 to 4 % m/m
2chemicalISO 12185; ISO 8754; ASTM D95; ISO 3733Fuel OilSee scope document

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

ENAC

ISO/IEC 17025

Active

1589/LE2950

View scope

Accredited scope, certificate 1589/LE2950

LineDisciplineMethodMatrixRange
1materialsUNE-EN ISO/IEC 17025:2017; ASTM D4052; ISO 12185; UNE-EN 116; ASTM D6371; ASTM D5771; IP 444Productos Petrolíferos; Petroleum ProductsSee scope document
2materialsASTM D86; ISO 3405; ASTM D93; ISO 2719; ASTM D6045; ASTM D4737; ISO 4264; ASTM D976; ASTM D4052; ISO 12185; UNE-EN 14104; UNE-EN 116; ASTM D6371Biodiesel and Biodiesel Blends-
3chemicalASTM D5771; IP 444; UNE-EN 14105; ASTM D93; ISO 2719; UNE-EN 14110; ASTM D6045Glycerol; Monoglycerides; Diglycerides; Triglycerides; Methanol; ColorSee scope document
4environmentalUNE-EN 14275Gasolina y gasóleo; Petrol and diesel-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

ENAC

ISO/IEC 17025

Active

1589/LE2951

View scope

Accredited scope, certificate 1589/LE2951

LineDisciplineMethodMatrixRange
1materialsISO 7507-4; UNE-EN ISO/IEC 17025:2017vertical cylindrical storage tanks for petroleum liquid productsto 54 m

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Barrio Revilla, 6R, Planta -1 del Edificio EIC del Parque Tecnológico de Ezkerraldea/Meatzaldea, Abanto Zierbena, 48500, ES

43.31886, -3.07538

Open in Maps

Accreditation data refreshed from the ENAC register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ENAC entry linked above.