FindTestingLabs
Registers collected 2026-08-22.See collection dates
United Kingdom

Thomas Bell-Wright International Consultants

PO Box 26385, Corner of 46th and 47th Streets, Jebel Ali Industrial Area 1, Dubai, United Arab Emirates, United Kingdom

UKAS|4439ISO/IEC 17025Register collected 2026-08-22
Certificates
1
Scope items
8
Locations
2

Contact this laboratory

Watch this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Thomas Bell-Wright International Consultants?

Claim this profile to keep it accurate.

Claim this profile

Register record

UKASCollected
4439Active

Certificates and scope

1
UKAS

ISO/IEC 17025

Active

4439

View scope

Accredited scope, certificate 4439

DisciplineMethodMatrixRange
materialsISO/IEC 17025:2017doors; windows; curtain walling; building cladding; partitions; building components; building materials-
materialsASTM E 84-24; UL 723; BS EN ISO 1182:2020; BS EN ISO 1182:2010; ASTM E 2652-22; ASTM E136-24c; BS EN ISO 11925-2 :2020; BS EN ISO 1716 :2018; BS EN 13823:2020+A1 :2022; ASTM E648-25; NFPA 253:2023; BS EN ISO 9239-1:2010; BS ISO 871:2022; ASTM D1929 – 23; NFPA 268:2022; NFPA 701:2023BUILDING CONSTRUCTION COMPONENTS AND MATERIALS; FLOOR COVERINGS; PLASTICS; EXTERNAL WALL ASSEMBLIES; TEXTILES and FILMS-
materialsBS EN 1366-3:2021 +A1:2024; ASTM E814-24; UL 1479 Ed4:2025 IS 12458:2019; BS EN 1366-4:2021; ISO 3008-4:2021; BS EN 1364-5:2017; UL 555 Ed 7:2020; TGD 19:2017; ASTM E2226-25; ASTM E283/E283M-19; ASTM E783:02(2018); ASTM E 330/E330M-14 (2021); ASTM E 331-00(2023); ASTM E547 - 00(2016); ASTM E1105-15(2023); AAMA 501.1-17; AAMA 501.5-07PENETRATION SEALS; LINEAR JOINT SEALS; AIR TRANSFER GRILLES; DAMPERS; CAVITY BARRIERS; HOSE STREAM APPLICATION; EXTERIOR WINDOWS, CURTAIN WALLS AND DOORS; INSTALLED EXTERIOR WINDOWS, CURTAIN WALLS AND DOORS; EXTERIOR WINDOWS, DOORS, SKYLIGHTS and CURTAIN WALLS; WINDOWS, CURTAIN WALLS and DOORS; EXTERIOR WALLS-
materialsBS EN 1364-2:2018; BS 476 - 22: Section 9:1987 Corr 1 :2014, Corr 2 :2024; ISO 834-9:2003Cor1 :2009; IS/ISO 834-9 :2003Cor1 :2009; ASTM E119-24; NFPA 251:2006; UL 263 Ed 14:2022; BS EN 1365-2:2014; BS 476 - 21; Section 7:1987 Corr 1:2014, Corr 2:2024; ISO 834-5:2000; IS/ISO 834-5:2000; BS EN 1365-3:2000; BS 476 - 21; Section 5:1987 corr 1: 2014, Corr 2:2024; ISO 834-6:2000; IS/ISO 834-6:2000; BS EN 1365-4:1999; BS 476 - 21; Section 6:1987 Corr 1 :2014, Corr 2 :2024; ISO 834-7:2000; IS/ISO 834-7:2000CEILINGS - Non load bearing; FLOORS AND ROOFS - Load bearing; BEAMS - Load bearing; COLUMNS - Load bearing-
materialsBR135; BS 8414-1:2015+A1:2017; BS 8414-1:2020; BS 8414-2:2015+A1:2017; BS 8414-2:2020; BS EN 13501-1:2018; BS EN 13501-2:2023; BS 476 - 20:1987 (Amd 1:1990, Corr 1:2014, Corr 2:2024); EN 1363-1:2020; EN 1363-2:1999 (Clauses 1 to 6 and clause 8); ISO 834-1:1999 (Amd 1:2012 & Amd 2 :2021); IS/ISO 834-1:1999 (Amd 1:2012); EN 1364-1:2015; BS 476 - 22: Section 5 :1987 Corr 1 :2014, Corr 2 :2024; ISO 834-8:2002 corr 1 :2009; IS/ISO 834-8 :2002 corr 1 :2009; ASTM E119-24; NFPA 251:2006; UL 263 Ed 14:2022; BS EN 1365-1:2012; BS 476 - 21:Section 8 :1987 Corr 1:2014, Corr 2 :2024; ISO 834-4:2000; IS/ISO 834-4:2000NON-LOADBEARING EXTERNAL CLADDING SYSTEMS; CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS; BUILDING CONSTRUCTION COMPONENTS AND MATERIALS - Fire resistance; WALLS AND PARTITIONS - Non load bearing; WALLS and PARTITIONS - Load bearing-
materialsBS EN 12153:2000; BS EN 12155:2000; BS EN 12179:2000; BS EN 14019:2016; AAMA 501.7-17; CWCT Section 5:2005; CWCT Section 6:2005; CWCT Section 7:2005; CWCT Section 9: 2005; CWCT Section 11:2005; CWCT Section 12:2005; CWCT Section 15:2005; CWCT Technical Note No 67; BS EN 13829:2001; BS EN ISO 9972:2015; ATTMA TS1:2007; ATTMA TSL1:2016 & 2021; ATTMA TSL2:2010 & 2021; AAMA 501.2-15; AAMA 501.4-18CURTAIN WALLING; BUILDING ENVELOPES; GLAZED ROOFING; WHOLE BUILDINGS; STOREFRONTS, CURTAIN WALLS and SLOPED GLAZING SYSTEMS20 to 50 °C
materialsASTM E 2353-21; ASTM E935-21; ANSI Z97.1-2015(R2020); CPSC 16 CFR 1201.4; ASTM E 1592-05(2017); BS EN 1026:2016; BS EN 1027:2016; BS EN 12211:2016SAFETY GLASS; SHEET METAL ROOFING and SIDING SYSTEMS; WINDOWS and DOORS-
materialsEN 1634-1:2014+A1 :2018; BS 476 - 22:1987: Section 6, 7 and 8 Corr 1:2014, Corr 2:2024; ISO 3008-1:2019; IS 17518-1:2022; ISO 3008-3:2016; UL 10B: Ed10: 2024; UL 10C 3rd Ed. 2016 (R2021); UL 10D 2nd Ed. 2017 (R2022); NFPA 252:2022; IS 16947:2018 (R2024); NFPA 288:2022; BS EN 1634-2:2008; BS EN 13381-4:2013; BS EN 13381-8:2013; BS EN 1366-6:2004; UL 9 Ed 8 2024; BS 476 - 22:1987: Section 10 Corr 1 :2014, Corr 2 :2024; ISO 3009:2003; NFPA 257:2022; IS 16945:2018 (R2024); EN 1364-3:2014; EN 1364-4:2014; IMO FTP Code 2010:2012 Edition - MSC 307(88) – Annex 1 : Part 3 – Appendix 1; ISO 20902-1:2018; UL 2079 5th Edition 2025DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES; BUILDING HARDWARE; APPLIED PASSIVE PROTECTION PRODUCTS; APPLIED REACTIVE PROTECTION PRODUCTS; RAISED ACCESS AND HOLLOW CORE FLOORS; WINDOW ASSEMBLIES; GLAZING; CURTAIN WALLING; MARINE CONSTRUCTIONS - bulkheads, doors and windows; BUILDING JOINT SYSTEMS-

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one.

Location

PO Box 26385, Corner of 46th and 47th Streets, Jebel Ali Industrial Area 1, Dubai, United Arab Emirates, GB

25.22332, 55.15941

Open in Maps

Accreditation data collected from the UKAS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the UKAS entry linked above.