UTEST Technical Laboratory Co. Ltd.
Unit 1001, No. 15, Block 3, No. 88, Xiangshan Avenue, Yongning Street, Zengcheng District, Guangzhou City, Guangdong Province, People's Republic of China, Guangdong Province, China
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at UTEST Technical Laboratory Co. Ltd.?
Claim this profile to keep it accurate.
Register record
- A2LARefreshed
- 4810.01Active
Certificates and scope
1ISO/IEC 17025
Active4810.01
The scope document we hold says it was valid until 2026-04-30. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.
Accredited scope, certificate 4810.01
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | electrical | IEC 62301: 2011; CSA C62301-11 (2016); CSA 381.1-08; CAS 381.1-17; e-CFR Title 10, Chapter 11, Subchapter D, Part 430 Appendix Z to Subpart B; CSA C381.2-17 (2017); ENERGY STAR Program Requirements for Luminaires, Version 2.0; ENERGY STAR Program Requirements for Lamps (Version 1.1 and 2.1); ENERGY STAR Test Method for Lamps – Start Time (September 2015); ENERGY STAR Elevated Temperature Light Output Ratio Test Method (September 2015); ENERGY STAR Ambient Temperature Life Testing Test Method (September 2015); ENERGY STAR Elevated Temperature Life Testing Test Method (September 2015); ENERGY STAR Program Requirements for Luminaires Version 2.2; ENERGY STAR Program Requirements for Luminaires and Lamps (Start Time Test Method, Oct-2017); ENERGY STAR Program Requirements for Downlights Version 1.0; ENERGY STAR® Program Requirements for Electric Vehicle Supply Equipment (only for AC), Version 1.2 | - | - |
| 2 | electrical | IES LM-16 (1993); IES LM-79 (2008); IES LM-58 (2013); CIE Pub. 13.3 (1995); CIE Pub. 15 (2004); ANSI C78.377 (2011, 2015); SASO 2870 (2018); SASO 2902 (2018); IES LM-79:2019; IES LM-40 (2010); IES LM-65 (2001, 2010, 2014); IES LM-84 (2014); IES LM-9 (2009); IES LM-66 (2000, 2011, 2014); ANSI C78.5 (1997, 2003); ANSI C82.2 (2002); ANSI C82.77:2002; ANSI C82.77-10:2014; IES LM-45; IES LM-82-12; IES LM-41 (1998, 2014); IES LM-10 (1996); IES LM-31 (1995); ANSI/UL 153:2018; ANSI/UL 1598:2021; ANSI/UL 1598C; ANSI/UL 1993:5; ANSI C62.41.2:2002; 10 CFR 430 Appendix BB to Subpart B; Energy related Products (EU 2019/2020); IEC 62612 | - | - |
| 3 | - | - | - | - |
| 4 | electrical | EN 60335-1; EN 60335-2-2; EN 60335-2-3; EN 60335-2-6; EN 60335-2-8; EN 60335-2-9; EN 60335-2-10; EN 60335-2-12; EN 60335-2-13; EN 60335-2-14; EN 60335-2-15; EN 60335-2-16; EN 60335-2-23; EN 60335-2-24; EN 60335-2-29; AS/NZS 60335.1; AS/NZS 60335.2.2; AS/NZS 60335.2.3; AS/NZS 60335.2.6; AS/NZS 60335.2.8; AS/NZS 60335.2.9; AS/NZS 60335.2.29; IEC 62233; EN 62233; UL4200A; IEC 60065; IEC 60950-1; IEC 60950-22; IEC 62368-1; EN 60065; EN 60950-1; EN 60950-22; EN 62368-1; AS/NZS 60065; AS/NZS 60950.1; AS/NZS 60950.22; AS/NZS 62368.1; IEC 60601-1; EN 60601-1; IEC 61558-1; IEC 61558-2-5; IEC 61558-2-6; IEC 61558-2-9; IEC 61558-2-15; IEC 61558-2-16; EN 61558-1; EN 61558-2-5; EN 61558-2-6; EN 61558-2-7; EN 61558-2-9; EN 61558-2-15; EN 61558-2-16; AS/NZS 61558.1; AS/NZS 61558.2.5; AS/NZS 61558.2.6; AS/NZS 61558.2.7; AS/NZS 61558.2.9; AS/NZS 61558.2.15; AS/NZS 61558-2-16; IEC 60825-1; EN 60825-1; IEC 60529; EN 60529; ISTA 1A (Vibration Test); ASTM E283; GB/T 2423.10; ANSI/IEEE C136.31; ASTM B117-19; ASTM D714-02; GB/T 2423.17 | Household and Similar Equipment; Audio/Video, Information and Communication Technology Equipment; Electrical Equipment for Medical Use; Power Transformers, Power Supplies, Reactors and Similar Products; Safety of Laser Products; Ingress Protection | - |
| 5 | electrical | IEC 60601-1; AS/NZS/IEC/EN 60335-1; AS/NZS/IEC/EN 62368 | - | - |
| 6 | electrical | - | - | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Unit 1001, No. 15, Block 3, No. 88, Xiangshan Avenue, Yongning Street, Zengcheng District, Guangzhou City, Guangdong Province, People's Republic of China, Guangdong Province, CN
37.35052, -121.89372
Open in MapsOther Locations
1 other site in this organization
Labs with overlapping accredited scope in China
- Hwa-Hsing (Dongguan) Testing Co.,Guangdong · ~3,685 kmA2LAShares 1 accredited test methodIEC 60601-1
- Eurofins Electrical Testing Service (Shanghai) Co.,Shanghai · ~3,783 kmA2LAShares 1 accredited test methodIEC 60601-1
- TUV Rheinland (Shanghai) Co.,Shanghai · ~3,783 kmA2LAShares 1 accredited test methodIEC 60601-1
- DEKRA Testing and Certification (Shanghai) Ltd., Guangzhou BranchGuangzhou · ~11,154 kmA2LAShares 1 accredited test methodIEC 60601-1
- SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou BranchGuangzhou, Guangdong · ~11,154 kmA2LAShares 1 accredited test methodIEC 60601-1
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.