SIRIM QAS INTERNATIONAL SDN BHD
RFEMC Testing Section, SIRIM QAS International Sdn Bhd c/o Penang Skills Development Center, 1, Jalan Sultan Azlan Shah, Bandar Bayan Baru, Penang, Malaysia, Penang, Malaysia
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at SIRIM QAS INTERNATIONAL SDN BHD?
Claim this profile to keep it accurate.
Register record
- A2LARefreshed
- 7755.01Active
Accredited standards
We have not yet extracted the standard numbers from this lab’s scope document. The scope text we hold is below.
Scope as published by A2LA
3 lines
ISO/IEC 17025
Active7755.01
The scope document we hold says it is valid until 2028-06-30.
Accredited scope, certificate 7755.01
This scope has not been split into individual lines yet. Below is the text of the scope document as published.
Part 1 of 3
(A2LA Cert. No. 7755.01) 07/27/2026 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 SIRIM QAS INTERNATIONAL SDN BHD RFEMC Testing Section, SIRIM QAS International Sdn Bhd. c/o Penang Skills Development Center 1, Jalan Sultan Azlan Shah, Bandar Bayan Baru, 11900 Bayan Lepas, Penang, Malaysia Norhayati Md Jonit Phone: +60123398176 Email: hayatimd@sirim.my ELECTRICAL Valid To: June 30, 2028 Certificate Number: 7755.01 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following electromagnetic compatibility, product safety, and wireless (CTIA, CCF) tests: Test Technology: Test Method(s) 1, 2: Emissions Radiated and Conducted CISPR 11; EN 55011; AS/NZS CISPR 11; BS EN 55011; CISPR 14-1; EN 55014-1; EN IEC 55014-1; AS/NZS CISPR 14.1; AS/NZS CISPR 14.1; J 55014-1; BS EN 55014-1; BS EN IEC 55014-1; CISPR 15; EN IEC 55015; AS/NZS CISPR 15; J 55015; BS EN 55015; BS EN IEC 55015; CISPR 32; EN 55032; AS/NZS CISPR 32; J55032; BS EN 55032; IEC 61000-6-3; EN 61000-6-3; EN IEC 61000-6-3; AS/NZS 61000.6.3; BS EN 61000-6-3; BS EN IEC 61000-6-3; IEC 61000-6-4; EN 61000-6-4; EN IEC 61000-6-4; BS EN 61000-6-4; BS EN IEC 61000-6-4; AS/NZS 61000.6.4 Harmonic Current Emissions IEC 61000-3-2; EN IEC 61000-3-2; BS EN IEC 61000-3-2 Voltage Changes, Fluctuations, and Flicker IEC 61000-3-3; EN 61000-3-3; BS EN 61000-3-3
Part 2 of 3
(A2LA Cert. No. 7755.01) 07/27/2026 Page 2 of 2 Test Technology: Test Method(s) 1, 2: Immunity Electrostatic Discharge (ESD) EN 61000-4-2, IEC 61000-4-2 Radiated Immunity IEC 61000-4-3;EN IEC 61000-4-3; BS EN IEC 61000-4-3 Electrical Fast Transient / Burst (EFT) IEC 61000-4-4; EN 61000-4-4; BS EN 61000-4-4 Surge Immunity IEC 61000-4-5; EN 61000-4-5; BS EN 61000-4-5 Conducted Immunity IEC 61000-4-6; EN 61000-4-6; BS EN 61000-4-6; EN IEC 61000-4-6; BS EN IEC 61000-4-6 Power Frequency Magnetic Field Immunity IEC 61000-4-8; EN 61000-4-8; BS EN 61000-4-8 Voltage Dips, Short Interruption and Voltage Variance IEC 61000-4-11; EN 61000-4-11; EN IEC 61000-4-11; BS EN 61000-4-11; BS EN IEC 61000-4-11 Generic or Product Specific EMC Standards Medical Equipment IEC 60601-1-2 (excluding section 8.11); IEC 61326-1; IEC 61326-2-6 RF Bluetooth / Wifi ETSI EN 300 328; ETSI EN 301 893 Short-Range Devices (SRDs) ETSI EN 300 440 (sections 4.2.2, 4.2.4, 4,3.5 only); ETSI EN 300 220-1 (sections 5.2, 5.9 only) Automotive EMC Bulk Current Injection (Ford, GM) ISO 11452-4 1 When the date, edition, version, etc. is not identified in the scope of accreditation, laboratories may use the version that immediately precedes the current version for a period of one year from the date of publication of the standard measurement method, per Annex A, Part C of A2LA R101 - General Requirements: Accreditation of Conformity Assessment Bodies. 2 The laboratory is only accredited for testing activities outlined within the test methods listed above. Reference to any other activity within these standards, such as risk management or risk assessment, does not fall within the laboratory’s accredited capabilities.
Part 3 of 3
r SIRIM QAS INTERNATIONAL SDN BHD Penang, Malaysia for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 27th day of July 2026. Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 7755.01 Valid to June 30, 2028 For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation. Accredited Laborator A2LA has accredited
Text extracted from the accredited scope document. Layout and tables from the original may not carry over; the scope document itself is the authoritative copy.
Location
RFEMC Testing Section, SIRIM QAS International Sdn Bhd c/o Penang Skills Development Center, 1, Jalan Sultan Azlan Shah, Bandar Bayan Baru, Penang, Malaysia, Penang, MY
39.95407, -75.15606
Open in MapsAccreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.