PROCHEM SRL Studio Chimico Professionale
Via Roma, 20, 07017, Ploaghe, Italy
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at PROCHEM SRL Studio Chimico Professionale?
Claim this profile to keep it accurate.
Register record
- ACCREDIARefreshed
- 02079Active
Accredited standards
2Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
APAT CNR IRSA 4020 Man 29 2003Name not checked yet
APAT CNR IRSA 4020 Man 29 2003; APAT CNR IRSA 2030 Man 29 2003; APAT CNR IRSA 3020 Man 29 2003; APAT CNR IRSA 2060 Man 29 2003; UNI EN 12457-2:2004
EN 12457-2Characterisation of waste - Leaching - Compliance test for leaching of granular waste materials and sludges - Part 2: One stage batch test at a liquid to solid ratio of 10 l/kg for materials with particle size below 4 mm (without or with size reduction)
APAT CNR IRSA 4020 Man 29 2003; APAT CNR IRSA 2030 Man 29 2003; APAT CNR IRSA 3020 Man 29 2003; APAT CNR IRSA 2060 Man 29 2003; UNI EN 12457-2:2004
Scope as published by ACCREDIA
2 lines
ISO/IEC 17025
Active02079
Accredited scope, certificate 02079
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | chemical | APAT CNR IRSA 4020 Man 29 2003; APAT CNR IRSA 2030 Man 29 2003; APAT CNR IRSA 3020 Man 29 2003; APAT CNR IRSA 2060 Man 29 2003; UNI EN 12457-2:2004 | Drinking water | 0.1 to 12880 µg/L; µS/cm; mg/L |
| 2 | - | - | - | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Italy
- BIOMIL S.R.L.Livorno · ~271 kmACCREDIAShares 2 accredited methods and materialsAPAT CNR IRSA 4020 Man 29 2003Drinking water
- Bio ConsultFollonica · ~302 kmACCREDIAShares 2 accredited methods and materialsAPAT CNR IRSA 4020 Man 29 2003Drinking water
- BioconsultRoma · ~349 kmACCREDIAShares 2 accredited methods and materialsAPAT CNR IRSA 4020 Man 29 2003Drinking water
- BLUECHEMICALLucca · ~381 kmACCREDIAShares 2 accredited methods and materialsAPAT CNR IRSA 4020 Man 29 2003Drinking water
- Chelab S.r.l.Cairo Montenotte · ~415 kmACCREDIAShares 2 accredited methods and materialsAPAT CNR IRSA 4020 Man 29 2003Drinking water
Accreditation data refreshed from the ACCREDIA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.