Registers refreshed 2026-11-20.See refresh dates
Accredited lab directory · Part of the EN 55016 series

EN 55016-2-3 Accredited Testing Labs in Italy

6 laboratories in Italy are accredited by ACCREDIA to perform EN 55016-2-3 testing. We don't know yet whether 1 of them takes outside work. From the accredited scope text: “EN 55016-2-3:2006, EN 55016-2-3:2010/A1:2010/AC:2013/A2: 2014, EN 55016-2-3:2017/A1:2019, EN 55016-2-3:2017/A1:2019/A2:2023 MIL-STD-461G:2015 EN 61000-4-5:1995/A1:2001, EN 61000-4-5:2006, EN 61000-4-5” “EN 55016-2-3:2017/A1:2020, CISPR 16-2-3:2016/AMD1:2019/AMD2:2023, EN 55016-2-3:2017/A1:2019/A2:2023 _ _ Prova di immunità ad impulso/Surge immunity test - solo/only max 16 A 1 phase CEI EN 61000-4-5:2” “EN 55016-2-3:2017/A1:2020, CISPR 16-2-3:2006, CISPR 16-2-3:2010/AMD1:2010/AMD2:2014, CISPR 16-2-3:2016/AMD1:2019, EN 55016-2-3:2006, EN 55016-2-3:2010/A1:2010/AC:2013/A2: 2014, EN 55016-2-3:2017/A1:20” “EN 55016-2-3:2017/A1:2019/A2:2023 Misura della resistenza di isolamento/Measurement of insulation resistance (up to 500MOhm) ENEL GLI03 (EMC) 1982 Potenza di disturbo/Disturbance power CISPR 16-2-2:20”

Labs
6
Primary AB
ACCREDIA6 labs
Part of a series

See all 13 labs in Italy for EN 55016 (any part)

Part 1-2: 3 labs · Part 1-3: 1 lab · Part 1-4: 2 labs · Part 2-1: 9 labs · Part 2-2: 1 lab · Part 2-3: 6 labs

Go to the series ↑

Accredited Labs

TUV ITALIA

Brugine, IT

Scope

EN 55016-2-3:2017/A1:2019/A2:2023 Misura della resistenza di isolamento/Measurement of insulation resistance (up to 500MOhm) ENEL GLI03 (EMC) 1982 Potenza di disturbo/Disturbance power CISPR 16-2-2:2010, EN 55016-2-2:2011 _ _ _ _

View lab

C.E.I.A. Spa a socio unico Sez. LACE Laboratorio di Compatibilità Elettromagnetica

Civitella in Valdichiana, IT

Scope

EN 55016-2-3:2006, EN 55016-2-3:2010/A1:2010/AC:2013/A2: 2014, EN 55016-2-3:2017/A1:2019, EN 55016-2-3:2017/A1:2019/A2:2023 MIL-STD-461G:2015 EN 61000-4-5:1995/A1:2001, EN 61000-4-5:2006, EN 61000-4-5:2014/A1:2017, IEC 61000-4-5:1995/COR1

View lab

Laboratorio EMC Sitael

Mola di Bari, IT

Scope

EN 55016-2-3:2017/A1:2020, CISPR 16-2-3:2016/AMD1:2019/AMD2:2023, EN 55016-2-3:2017/A1:2019/A2:2023 _ _ Prova di immunità ad impulso/Surge immunity test - solo/only max 16 A 1 phase CEI EN 61000-4-5:2016/A1:2018, EN _ Prove d'immunità

View lab

Elettra

Calenzano, IT

Scope

EN 55016-2-3:2017/A1:2020, CISPR 16-2-3:2006, CISPR 16-2-3:2010/AMD1:2010/AMD2:2014, CISPR 16-2-3:2016/AMD1:2019, EN 55016-2-3:2006, EN 55016-2-3:2010/A1:2010/AC:2013/A2: 2014, EN 55016-2-3:2017/A1:2019, EN 55016-2-3:2017/A1:2019/A2:2023 E

View lab

Teslab

Livorno, IT

Scope

EN 55016-2-3:2017/A1:2019/A2:2023 _ Par 5.03 - Variazioni di alimentazione/Supply voltage variations, Par 5.04 - Sovratensione di alimentazione e tensione inversa/Supply over voltage and reverse voltage, Par 5.06 - Emissione RF (disturbi e

View lab

EMC srl

Genova, IT

We don't know yet whether this lab takes outside work.
Scope

EN 55016-2-3:2017/A1:2020, CISPR 16-2-3:2016/AMD1:2019, EN 55016-2-3:2017/A1:2019 CEI EN 61000-4-5:2016/A1:2018, EN 61000-4-5:2014/A1:2017, IEC 61000-4-5:2014/AMD1:2017 Prove di immunità ai transitori - raffiche di impulsi elettrici veloc

View lab

About ISO/IEC 17025 in Italy

Italian Accreditation Body (ACCREDIA) is the primary accreditation body issuing ISO/IEC 17025 accreditation for testing laboratories in Italy.

ISO/IEC 17025 is the international standard for the competence of testing and calibration laboratories. Accreditation to this standard provides independent confirmation that a laboratory operates a quality management system and is technically competent to produce valid results within its declared scope.