FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
China

SGS-CSTC Standard Technical Services Co., Ltd. Wuhan Branch

Building 5, Zone 6, The Private-enterprise Science and Technology Industrial Park, Zhuanyang Avenue, Wuhan Economic and Technological Development Zone, Wuhan, 430058, People's Republic of China, Wuhan, China

A2LA|7129.01ISO/IEC 17025Register refreshed 2026-09-25
Certificates
1
Scope items
5
Standards
32
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at SGS-CSTC Standard Technical Services Co., Ltd. Wuhan Branch?

Claim this profile to keep it accurate.

Register record

A2LARefreshed
7129.01Active

Accredited standards

32

Our reading of the A2LA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

IEC 60601 series

IEC 60601-1Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
As written on the certificate · Line 1 (A2LA 7129.01)

IEC 60601-1; IEC 60601-1-3; IEC 60601-1-6; IEC 62366-1; IEC 60601-1-8; IEC TR 62366-2; IEC 60601-1-11; IEC 60601-2-2; IEC 60601-2-10; IEC 60601-2-18; IEC 60601-2-22; IEC 60601-2-28; IEC 60601-2-36; IEC 60601-2-37; IEC 60601-2-43; IEC 60601-2-44; IEC 60601-2-45; IEC 60601-2-54; IEC 60601-2-57; IEC 80601-2-60; IEC 60601-2-63; IEC 60601-2-65; EN 60601-1; EN 60601-1-3

As written on the certificate · Line 4 (A2LA 7129.01)

IEC 60601-1; EN 60601-1; ANSI/AAMI ES60601-1; CAN/CSA-C22.2 NO. 60601-1; IEC 60601-2-2; EN 60601-2-2; CSA C22.2 NO. 60601-2-2; IEC 61010-1; EN 61010-1; ANSI UL 61010-1; CAN/CSA-C22.2 No. 61010-1

IEC 60601-1-3Name not checked yet
As written on the certificate · Line 1 (A2LA 7129.01)

IEC 60601-1; IEC 60601-1-3; IEC 60601-1-6; IEC 62366-1; IEC 60601-1-8; IEC TR 62366-2; IEC 60601-1-11; IEC 60601-2-2; IEC 60601-2-10; IEC 60601-2-18; IEC 60601-2-22; IEC 60601-2-28; IEC 60601-2-36; IEC 60601-2-37; IEC 60601-2-43; IEC 60601-2-44; IEC 60601-2-45; IEC 60601-2-54; IEC 60601-2-57; IEC 80601-2-60; IEC 60601-2-63; IEC 60601-2-65; EN 60601-1; EN 60601-1-3

IEC 60601-1-6Name not checked yet
As written on the certificate · Line 1 (A2LA 7129.01)

IEC 60601-1; IEC 60601-1-3; IEC 60601-1-6; IEC 62366-1; IEC 60601-1-8; IEC TR 62366-2; IEC 60601-1-11; IEC 60601-2-2; IEC 60601-2-10; IEC 60601-2-18; IEC 60601-2-22; IEC 60601-2-28; IEC 60601-2-36; IEC 60601-2-37; IEC 60601-2-43; IEC 60601-2-44; IEC 60601-2-45; IEC 60601-2-54; IEC 60601-2-57; IEC 80601-2-60; IEC 60601-2-63; IEC 60601-2-65; EN 60601-1; EN 60601-1-3

As written on the certificate · Line 2 (A2LA 7129.01)

EN 60601-1-6; EN 62366-1; EN 60601-1-8; EN 60601-1-11; EN IEC 60601-2-2; EN 60601-2-10; EN 60601-2-18; EN IEC 60601-2-22; EN IEC 60601-2-28 2; EN 60601-2-36; EN 60601-2-37; EN 60601-2-43 2; EN 60601-2-44 2; EN 60601-2-45 2; EN IEC 60601-2-54 2; EN 60601-2-57; EN IEC 80601-2-60; EN 60601-2-63 2; EN 60601-2-65 2; ANSI/AAMI ES 60601-1; ANSI/AAMI/IEC 62366-1; ANSI/AAMI/IEC 60601-1-8; ANSI/AAMI HA 60601-1-11; ANSI AAMI IEC 60601-2-2; CAN/CSA-C22.2 No. 60601-1; CAN/CSA C22.2 No. 60601-1-3 2; CAN/CSA C22.2 No. 62366-1; CAN/CSA C22.2 No. 60601-1-8; CAN/CSA C22.2 No. 60601-2-2; CAN/CSA C22.2 No. 60601-2-10; CAN/CSA C22.2 No. 60601-1-11; CSA C22.2 No. 60601-2-18; CSA C22.2 No. 60601-2-22; CSA C22.2 No. 60601-2-28 2; CSA C22.2 No. 60601-2-36; CSA-C22.2 No. 60601-2-37; CAN/CSA C22.2 No. 60601-2-43 2; CSA C22.2 No. 60601-2-44 2; CAN/CSA C22.2 No. 60601-2-45 2; CAN/CSA-C22.2 No. 60601-2-54 2; CSA C22.2 No. 60601-2-57; CSA C22.2 No. 80601-2-60; CSA C22.2 No. 60601-2-63 2; CSA C22.2 No. 60601-2-65 2

IEC 60601-1-8Name not checked yet
As written on the certificate · Line 1 (A2LA 7129.01)

IEC 60601-1; IEC 60601-1-3; IEC 60601-1-6; IEC 62366-1; IEC 60601-1-8; IEC TR 62366-2; IEC 60601-1-11; IEC 60601-2-2; IEC 60601-2-10; IEC 60601-2-18; IEC 60601-2-22; IEC 60601-2-28; IEC 60601-2-36; IEC 60601-2-37; IEC 60601-2-43; IEC 60601-2-44; IEC 60601-2-45; IEC 60601-2-54; IEC 60601-2-57; IEC 80601-2-60; IEC 60601-2-63; IEC 60601-2-65; EN 60601-1; EN 60601-1-3

As written on the certificate · Line 2 (A2LA 7129.01)

EN 60601-1-6; EN 62366-1; EN 60601-1-8; EN 60601-1-11; EN IEC 60601-2-2; EN 60601-2-10; EN 60601-2-18; EN IEC 60601-2-22; EN IEC 60601-2-28 2; EN 60601-2-36; EN 60601-2-37; EN 60601-2-43 2; EN 60601-2-44 2; EN 60601-2-45 2; EN IEC 60601-2-54 2; EN 60601-2-57; EN IEC 80601-2-60; EN 60601-2-63 2; EN 60601-2-65 2; ANSI/AAMI ES 60601-1; ANSI/AAMI/IEC 62366-1; ANSI/AAMI/IEC 60601-1-8; ANSI/AAMI HA 60601-1-11; ANSI AAMI IEC 60601-2-2; CAN/CSA-C22.2 No. 60601-1; CAN/CSA C22.2 No. 60601-1-3 2; CAN/CSA C22.2 No. 62366-1; CAN/CSA C22.2 No. 60601-1-8; CAN/CSA C22.2 No. 60601-2-2; CAN/CSA C22.2 No. 60601-2-10; CAN/CSA C22.2 No. 60601-1-11; CSA C22.2 No. 60601-2-18; CSA C22.2 No. 60601-2-22; CSA C22.2 No. 60601-2-28 2; CSA C22.2 No. 60601-2-36; CSA-C22.2 No. 60601-2-37; CAN/CSA C22.2 No. 60601-2-43 2; CSA C22.2 No. 60601-2-44 2; CAN/CSA C22.2 No. 60601-2-45 2; CAN/CSA-C22.2 No. 60601-2-54 2; CSA C22.2 No. 60601-2-57; CSA C22.2 No. 80601-2-60; CSA C22.2 No. 60601-2-63 2; CSA C22.2 No. 60601-2-65 2

IEC 60601-1-11Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance - Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment
As written on the certificate · Line 1 (A2LA 7129.01)

IEC 60601-1; IEC 60601-1-3; IEC 60601-1-6; IEC 62366-1; IEC 60601-1-8; IEC TR 62366-2; IEC 60601-1-11; IEC 60601-2-2; IEC 60601-2-10; IEC 60601-2-18; IEC 60601-2-22; IEC 60601-2-28; IEC 60601-2-36; IEC 60601-2-37; IEC 60601-2-43; IEC 60601-2-44; IEC 60601-2-45; IEC 60601-2-54; IEC 60601-2-57; IEC 80601-2-60; IEC 60601-2-63; IEC 60601-2-65; EN 60601-1; EN 60601-1-3

As written on the certificate · Line 2 (A2LA 7129.01)

EN 60601-1-6; EN 62366-1; EN 60601-1-8; EN 60601-1-11; EN IEC 60601-2-2; EN 60601-2-10; EN 60601-2-18; EN IEC 60601-2-22; EN IEC 60601-2-28 2; EN 60601-2-36; EN 60601-2-37; EN 60601-2-43 2; EN 60601-2-44 2; EN 60601-2-45 2; EN IEC 60601-2-54 2; EN 60601-2-57; EN IEC 80601-2-60; EN 60601-2-63 2; EN 60601-2-65 2; ANSI/AAMI ES 60601-1; ANSI/AAMI/IEC 62366-1; ANSI/AAMI/IEC 60601-1-8; ANSI/AAMI HA 60601-1-11; ANSI AAMI IEC 60601-2-2; CAN/CSA-C22.2 No. 60601-1; CAN/CSA C22.2 No. 60601-1-3 2; CAN/CSA C22.2 No. 62366-1; CAN/CSA C22.2 No. 60601-1-8; CAN/CSA C22.2 No. 60601-2-2; CAN/CSA C22.2 No. 60601-2-10; CAN/CSA C22.2 No. 60601-1-11; CSA C22.2 No. 60601-2-18; CSA C22.2 No. 60601-2-22; CSA C22.2 No. 60601-2-28 2; CSA C22.2 No. 60601-2-36; CSA-C22.2 No. 60601-2-37; CAN/CSA C22.2 No. 60601-2-43 2; CSA C22.2 No. 60601-2-44 2; CAN/CSA C22.2 No. 60601-2-45 2; CAN/CSA-C22.2 No. 60601-2-54 2; CSA C22.2 No. 60601-2-57; CSA C22.2 No. 80601-2-60; CSA C22.2 No. 60601-2-63 2; CSA C22.2 No. 60601-2-65 2

IEC 60601-2-2Name not checked yet
As written on the certificate · Line 1 (A2LA 7129.01)

IEC 60601-1; IEC 60601-1-3; IEC 60601-1-6; IEC 62366-1; IEC 60601-1-8; IEC TR 62366-2; IEC 60601-1-11; IEC 60601-2-2; IEC 60601-2-10; IEC 60601-2-18; IEC 60601-2-22; IEC 60601-2-28; IEC 60601-2-36; IEC 60601-2-37; IEC 60601-2-43; IEC 60601-2-44; IEC 60601-2-45; IEC 60601-2-54; IEC 60601-2-57; IEC 80601-2-60; IEC 60601-2-63; IEC 60601-2-65; EN 60601-1; EN 60601-1-3

As written on the certificate · Line 2 (A2LA 7129.01)

EN 60601-1-6; EN 62366-1; EN 60601-1-8; EN 60601-1-11; EN IEC 60601-2-2; EN 60601-2-10; EN 60601-2-18; EN IEC 60601-2-22; EN IEC 60601-2-28 2; EN 60601-2-36; EN 60601-2-37; EN 60601-2-43 2; EN 60601-2-44 2; EN 60601-2-45 2; EN IEC 60601-2-54 2; EN 60601-2-57; EN IEC 80601-2-60; EN 60601-2-63 2; EN 60601-2-65 2; ANSI/AAMI ES 60601-1; ANSI/AAMI/IEC 62366-1; ANSI/AAMI/IEC 60601-1-8; ANSI/AAMI HA 60601-1-11; ANSI AAMI IEC 60601-2-2; CAN/CSA-C22.2 No. 60601-1; CAN/CSA C22.2 No. 60601-1-3 2; CAN/CSA C22.2 No. 62366-1; CAN/CSA C22.2 No. 60601-1-8; CAN/CSA C22.2 No. 60601-2-2; CAN/CSA C22.2 No. 60601-2-10; CAN/CSA C22.2 No. 60601-1-11; CSA C22.2 No. 60601-2-18; CSA C22.2 No. 60601-2-22; CSA C22.2 No. 60601-2-28 2; CSA C22.2 No. 60601-2-36; CSA-C22.2 No. 60601-2-37; CAN/CSA C22.2 No. 60601-2-43 2; CSA C22.2 No. 60601-2-44 2; CAN/CSA C22.2 No. 60601-2-45 2; CAN/CSA-C22.2 No. 60601-2-54 2; CSA C22.2 No. 60601-2-57; CSA C22.2 No. 80601-2-60; CSA C22.2 No. 60601-2-63 2; CSA C22.2 No. 60601-2-65 2

As written on the certificate · Line 4 (A2LA 7129.01)

IEC 60601-1; EN 60601-1; ANSI/AAMI ES60601-1; CAN/CSA-C22.2 NO. 60601-1; IEC 60601-2-2; EN 60601-2-2; CSA C22.2 NO. 60601-2-2; IEC 61010-1; EN 61010-1; ANSI UL 61010-1; CAN/CSA-C22.2 No. 61010-1

IEC 60601-2-10Name not checked yet
As written on the certificate · Line 1 (A2LA 7129.01)

IEC 60601-1; IEC 60601-1-3; IEC 60601-1-6; IEC 62366-1; IEC 60601-1-8; IEC TR 62366-2; IEC 60601-1-11; IEC 60601-2-2; IEC 60601-2-10; IEC 60601-2-18; IEC 60601-2-22; IEC 60601-2-28; IEC 60601-2-36; IEC 60601-2-37; IEC 60601-2-43; IEC 60601-2-44; IEC 60601-2-45; IEC 60601-2-54; IEC 60601-2-57; IEC 80601-2-60; IEC 60601-2-63; IEC 60601-2-65; EN 60601-1; EN 60601-1-3

As written on the certificate · Line 2 (A2LA 7129.01)

EN 60601-1-6; EN 62366-1; EN 60601-1-8; EN 60601-1-11; EN IEC 60601-2-2; EN 60601-2-10; EN 60601-2-18; EN IEC 60601-2-22; EN IEC 60601-2-28 2; EN 60601-2-36; EN 60601-2-37; EN 60601-2-43 2; EN 60601-2-44 2; EN 60601-2-45 2; EN IEC 60601-2-54 2; EN 60601-2-57; EN IEC 80601-2-60; EN 60601-2-63 2; EN 60601-2-65 2; ANSI/AAMI ES 60601-1; ANSI/AAMI/IEC 62366-1; ANSI/AAMI/IEC 60601-1-8; ANSI/AAMI HA 60601-1-11; ANSI AAMI IEC 60601-2-2; CAN/CSA-C22.2 No. 60601-1; CAN/CSA C22.2 No. 60601-1-3 2; CAN/CSA C22.2 No. 62366-1; CAN/CSA C22.2 No. 60601-1-8; CAN/CSA C22.2 No. 60601-2-2; CAN/CSA C22.2 No. 60601-2-10; CAN/CSA C22.2 No. 60601-1-11; CSA C22.2 No. 60601-2-18; CSA C22.2 No. 60601-2-22; CSA C22.2 No. 60601-2-28 2; CSA C22.2 No. 60601-2-36; CSA-C22.2 No. 60601-2-37; CAN/CSA C22.2 No. 60601-2-43 2; CSA C22.2 No. 60601-2-44 2; CAN/CSA C22.2 No. 60601-2-45 2; CAN/CSA-C22.2 No. 60601-2-54 2; CSA C22.2 No. 60601-2-57; CSA C22.2 No. 80601-2-60; CSA C22.2 No. 60601-2-63 2; CSA C22.2 No. 60601-2-65 2

IEC 60601-2-18Name not checked yet
As written on the certificate · Line 1 (A2LA 7129.01)

IEC 60601-1; IEC 60601-1-3; IEC 60601-1-6; IEC 62366-1; IEC 60601-1-8; IEC TR 62366-2; IEC 60601-1-11; IEC 60601-2-2; IEC 60601-2-10; IEC 60601-2-18; IEC 60601-2-22; IEC 60601-2-28; IEC 60601-2-36; IEC 60601-2-37; IEC 60601-2-43; IEC 60601-2-44; IEC 60601-2-45; IEC 60601-2-54; IEC 60601-2-57; IEC 80601-2-60; IEC 60601-2-63; IEC 60601-2-65; EN 60601-1; EN 60601-1-3

As written on the certificate · Line 2 (A2LA 7129.01)

EN 60601-1-6; EN 62366-1; EN 60601-1-8; EN 60601-1-11; EN IEC 60601-2-2; EN 60601-2-10; EN 60601-2-18; EN IEC 60601-2-22; EN IEC 60601-2-28 2; EN 60601-2-36; EN 60601-2-37; EN 60601-2-43 2; EN 60601-2-44 2; EN 60601-2-45 2; EN IEC 60601-2-54 2; EN 60601-2-57; EN IEC 80601-2-60; EN 60601-2-63 2; EN 60601-2-65 2; ANSI/AAMI ES 60601-1; ANSI/AAMI/IEC 62366-1; ANSI/AAMI/IEC 60601-1-8; ANSI/AAMI HA 60601-1-11; ANSI AAMI IEC 60601-2-2; CAN/CSA-C22.2 No. 60601-1; CAN/CSA C22.2 No. 60601-1-3 2; CAN/CSA C22.2 No. 62366-1; CAN/CSA C22.2 No. 60601-1-8; CAN/CSA C22.2 No. 60601-2-2; CAN/CSA C22.2 No. 60601-2-10; CAN/CSA C22.2 No. 60601-1-11; CSA C22.2 No. 60601-2-18; CSA C22.2 No. 60601-2-22; CSA C22.2 No. 60601-2-28 2; CSA C22.2 No. 60601-2-36; CSA-C22.2 No. 60601-2-37; CAN/CSA C22.2 No. 60601-2-43 2; CSA C22.2 No. 60601-2-44 2; CAN/CSA C22.2 No. 60601-2-45 2; CAN/CSA-C22.2 No. 60601-2-54 2; CSA C22.2 No. 60601-2-57; CSA C22.2 No. 80601-2-60; CSA C22.2 No. 60601-2-63 2; CSA C22.2 No. 60601-2-65 2

IEC 60601-2-22Name not checked yet
As written on the certificate · Line 1 (A2LA 7129.01)

IEC 60601-1; IEC 60601-1-3; IEC 60601-1-6; IEC 62366-1; IEC 60601-1-8; IEC TR 62366-2; IEC 60601-1-11; IEC 60601-2-2; IEC 60601-2-10; IEC 60601-2-18; IEC 60601-2-22; IEC 60601-2-28; IEC 60601-2-36; IEC 60601-2-37; IEC 60601-2-43; IEC 60601-2-44; IEC 60601-2-45; IEC 60601-2-54; IEC 60601-2-57; IEC 80601-2-60; IEC 60601-2-63; IEC 60601-2-65; EN 60601-1; EN 60601-1-3

As written on the certificate · Line 2 (A2LA 7129.01)

EN 60601-1-6; EN 62366-1; EN 60601-1-8; EN 60601-1-11; EN IEC 60601-2-2; EN 60601-2-10; EN 60601-2-18; EN IEC 60601-2-22; EN IEC 60601-2-28 2; EN 60601-2-36; EN 60601-2-37; EN 60601-2-43 2; EN 60601-2-44 2; EN 60601-2-45 2; EN IEC 60601-2-54 2; EN 60601-2-57; EN IEC 80601-2-60; EN 60601-2-63 2; EN 60601-2-65 2; ANSI/AAMI ES 60601-1; ANSI/AAMI/IEC 62366-1; ANSI/AAMI/IEC 60601-1-8; ANSI/AAMI HA 60601-1-11; ANSI AAMI IEC 60601-2-2; CAN/CSA-C22.2 No. 60601-1; CAN/CSA C22.2 No. 60601-1-3 2; CAN/CSA C22.2 No. 62366-1; CAN/CSA C22.2 No. 60601-1-8; CAN/CSA C22.2 No. 60601-2-2; CAN/CSA C22.2 No. 60601-2-10; CAN/CSA C22.2 No. 60601-1-11; CSA C22.2 No. 60601-2-18; CSA C22.2 No. 60601-2-22; CSA C22.2 No. 60601-2-28 2; CSA C22.2 No. 60601-2-36; CSA-C22.2 No. 60601-2-37; CAN/CSA C22.2 No. 60601-2-43 2; CSA C22.2 No. 60601-2-44 2; CAN/CSA C22.2 No. 60601-2-45 2; CAN/CSA-C22.2 No. 60601-2-54 2; CSA C22.2 No. 60601-2-57; CSA C22.2 No. 80601-2-60; CSA C22.2 No. 60601-2-63 2; CSA C22.2 No. 60601-2-65 2

IEC 60601-2-28Medical electrical equipment - Part 2-28: Particular requirements for the basic safety and essential performance of X-ray tube assemblies for medical diagnosis
As written on the certificate · Line 1 (A2LA 7129.01)

IEC 60601-1; IEC 60601-1-3; IEC 60601-1-6; IEC 62366-1; IEC 60601-1-8; IEC TR 62366-2; IEC 60601-1-11; IEC 60601-2-2; IEC 60601-2-10; IEC 60601-2-18; IEC 60601-2-22; IEC 60601-2-28; IEC 60601-2-36; IEC 60601-2-37; IEC 60601-2-43; IEC 60601-2-44; IEC 60601-2-45; IEC 60601-2-54; IEC 60601-2-57; IEC 80601-2-60; IEC 60601-2-63; IEC 60601-2-65; EN 60601-1; EN 60601-1-3

As written on the certificate · Line 2 (A2LA 7129.01)

EN 60601-1-6; EN 62366-1; EN 60601-1-8; EN 60601-1-11; EN IEC 60601-2-2; EN 60601-2-10; EN 60601-2-18; EN IEC 60601-2-22; EN IEC 60601-2-28 2; EN 60601-2-36; EN 60601-2-37; EN 60601-2-43 2; EN 60601-2-44 2; EN 60601-2-45 2; EN IEC 60601-2-54 2; EN 60601-2-57; EN IEC 80601-2-60; EN 60601-2-63 2; EN 60601-2-65 2; ANSI/AAMI ES 60601-1; ANSI/AAMI/IEC 62366-1; ANSI/AAMI/IEC 60601-1-8; ANSI/AAMI HA 60601-1-11; ANSI AAMI IEC 60601-2-2; CAN/CSA-C22.2 No. 60601-1; CAN/CSA C22.2 No. 60601-1-3 2; CAN/CSA C22.2 No. 62366-1; CAN/CSA C22.2 No. 60601-1-8; CAN/CSA C22.2 No. 60601-2-2; CAN/CSA C22.2 No. 60601-2-10; CAN/CSA C22.2 No. 60601-1-11; CSA C22.2 No. 60601-2-18; CSA C22.2 No. 60601-2-22; CSA C22.2 No. 60601-2-28 2; CSA C22.2 No. 60601-2-36; CSA-C22.2 No. 60601-2-37; CAN/CSA C22.2 No. 60601-2-43 2; CSA C22.2 No. 60601-2-44 2; CAN/CSA C22.2 No. 60601-2-45 2; CAN/CSA-C22.2 No. 60601-2-54 2; CSA C22.2 No. 60601-2-57; CSA C22.2 No. 80601-2-60; CSA C22.2 No. 60601-2-63 2; CSA C22.2 No. 60601-2-65 2

IEC 60601-2-36Name not checked yet
As written on the certificate · Line 1 (A2LA 7129.01)

IEC 60601-1; IEC 60601-1-3; IEC 60601-1-6; IEC 62366-1; IEC 60601-1-8; IEC TR 62366-2; IEC 60601-1-11; IEC 60601-2-2; IEC 60601-2-10; IEC 60601-2-18; IEC 60601-2-22; IEC 60601-2-28; IEC 60601-2-36; IEC 60601-2-37; IEC 60601-2-43; IEC 60601-2-44; IEC 60601-2-45; IEC 60601-2-54; IEC 60601-2-57; IEC 80601-2-60; IEC 60601-2-63; IEC 60601-2-65; EN 60601-1; EN 60601-1-3

As written on the certificate · Line 2 (A2LA 7129.01)

EN 60601-1-6; EN 62366-1; EN 60601-1-8; EN 60601-1-11; EN IEC 60601-2-2; EN 60601-2-10; EN 60601-2-18; EN IEC 60601-2-22; EN IEC 60601-2-28 2; EN 60601-2-36; EN 60601-2-37; EN 60601-2-43 2; EN 60601-2-44 2; EN 60601-2-45 2; EN IEC 60601-2-54 2; EN 60601-2-57; EN IEC 80601-2-60; EN 60601-2-63 2; EN 60601-2-65 2; ANSI/AAMI ES 60601-1; ANSI/AAMI/IEC 62366-1; ANSI/AAMI/IEC 60601-1-8; ANSI/AAMI HA 60601-1-11; ANSI AAMI IEC 60601-2-2; CAN/CSA-C22.2 No. 60601-1; CAN/CSA C22.2 No. 60601-1-3 2; CAN/CSA C22.2 No. 62366-1; CAN/CSA C22.2 No. 60601-1-8; CAN/CSA C22.2 No. 60601-2-2; CAN/CSA C22.2 No. 60601-2-10; CAN/CSA C22.2 No. 60601-1-11; CSA C22.2 No. 60601-2-18; CSA C22.2 No. 60601-2-22; CSA C22.2 No. 60601-2-28 2; CSA C22.2 No. 60601-2-36; CSA-C22.2 No. 60601-2-37; CAN/CSA C22.2 No. 60601-2-43 2; CSA C22.2 No. 60601-2-44 2; CAN/CSA C22.2 No. 60601-2-45 2; CAN/CSA-C22.2 No. 60601-2-54 2; CSA C22.2 No. 60601-2-57; CSA C22.2 No. 80601-2-60; CSA C22.2 No. 60601-2-63 2; CSA C22.2 No. 60601-2-65 2

IEC 60601-2-37Name not checked yet
As written on the certificate · Line 1 (A2LA 7129.01)

IEC 60601-1; IEC 60601-1-3; IEC 60601-1-6; IEC 62366-1; IEC 60601-1-8; IEC TR 62366-2; IEC 60601-1-11; IEC 60601-2-2; IEC 60601-2-10; IEC 60601-2-18; IEC 60601-2-22; IEC 60601-2-28; IEC 60601-2-36; IEC 60601-2-37; IEC 60601-2-43; IEC 60601-2-44; IEC 60601-2-45; IEC 60601-2-54; IEC 60601-2-57; IEC 80601-2-60; IEC 60601-2-63; IEC 60601-2-65; EN 60601-1; EN 60601-1-3

As written on the certificate · Line 2 (A2LA 7129.01)

EN 60601-1-6; EN 62366-1; EN 60601-1-8; EN 60601-1-11; EN IEC 60601-2-2; EN 60601-2-10; EN 60601-2-18; EN IEC 60601-2-22; EN IEC 60601-2-28 2; EN 60601-2-36; EN 60601-2-37; EN 60601-2-43 2; EN 60601-2-44 2; EN 60601-2-45 2; EN IEC 60601-2-54 2; EN 60601-2-57; EN IEC 80601-2-60; EN 60601-2-63 2; EN 60601-2-65 2; ANSI/AAMI ES 60601-1; ANSI/AAMI/IEC 62366-1; ANSI/AAMI/IEC 60601-1-8; ANSI/AAMI HA 60601-1-11; ANSI AAMI IEC 60601-2-2; CAN/CSA-C22.2 No. 60601-1; CAN/CSA C22.2 No. 60601-1-3 2; CAN/CSA C22.2 No. 62366-1; CAN/CSA C22.2 No. 60601-1-8; CAN/CSA C22.2 No. 60601-2-2; CAN/CSA C22.2 No. 60601-2-10; CAN/CSA C22.2 No. 60601-1-11; CSA C22.2 No. 60601-2-18; CSA C22.2 No. 60601-2-22; CSA C22.2 No. 60601-2-28 2; CSA C22.2 No. 60601-2-36; CSA-C22.2 No. 60601-2-37; CAN/CSA C22.2 No. 60601-2-43 2; CSA C22.2 No. 60601-2-44 2; CAN/CSA C22.2 No. 60601-2-45 2; CAN/CSA-C22.2 No. 60601-2-54 2; CSA C22.2 No. 60601-2-57; CSA C22.2 No. 80601-2-60; CSA C22.2 No. 60601-2-63 2; CSA C22.2 No. 60601-2-65 2

IEC 60601-2-43Medical electrical equipment - Part 2-43: Particular requirements for the basic safety and essential performance of X-ray equipment for interventional procedures
As written on the certificate · Line 1 (A2LA 7129.01)

IEC 60601-1; IEC 60601-1-3; IEC 60601-1-6; IEC 62366-1; IEC 60601-1-8; IEC TR 62366-2; IEC 60601-1-11; IEC 60601-2-2; IEC 60601-2-10; IEC 60601-2-18; IEC 60601-2-22; IEC 60601-2-28; IEC 60601-2-36; IEC 60601-2-37; IEC 60601-2-43; IEC 60601-2-44; IEC 60601-2-45; IEC 60601-2-54; IEC 60601-2-57; IEC 80601-2-60; IEC 60601-2-63; IEC 60601-2-65; EN 60601-1; EN 60601-1-3

As written on the certificate · Line 2 (A2LA 7129.01)

EN 60601-1-6; EN 62366-1; EN 60601-1-8; EN 60601-1-11; EN IEC 60601-2-2; EN 60601-2-10; EN 60601-2-18; EN IEC 60601-2-22; EN IEC 60601-2-28 2; EN 60601-2-36; EN 60601-2-37; EN 60601-2-43 2; EN 60601-2-44 2; EN 60601-2-45 2; EN IEC 60601-2-54 2; EN 60601-2-57; EN IEC 80601-2-60; EN 60601-2-63 2; EN 60601-2-65 2; ANSI/AAMI ES 60601-1; ANSI/AAMI/IEC 62366-1; ANSI/AAMI/IEC 60601-1-8; ANSI/AAMI HA 60601-1-11; ANSI AAMI IEC 60601-2-2; CAN/CSA-C22.2 No. 60601-1; CAN/CSA C22.2 No. 60601-1-3 2; CAN/CSA C22.2 No. 62366-1; CAN/CSA C22.2 No. 60601-1-8; CAN/CSA C22.2 No. 60601-2-2; CAN/CSA C22.2 No. 60601-2-10; CAN/CSA C22.2 No. 60601-1-11; CSA C22.2 No. 60601-2-18; CSA C22.2 No. 60601-2-22; CSA C22.2 No. 60601-2-28 2; CSA C22.2 No. 60601-2-36; CSA-C22.2 No. 60601-2-37; CAN/CSA C22.2 No. 60601-2-43 2; CSA C22.2 No. 60601-2-44 2; CAN/CSA C22.2 No. 60601-2-45 2; CAN/CSA-C22.2 No. 60601-2-54 2; CSA C22.2 No. 60601-2-57; CSA C22.2 No. 80601-2-60; CSA C22.2 No. 60601-2-63 2; CSA C22.2 No. 60601-2-65 2

IEC 60601-2-44Medical electrical equipment - Part 2-44: Particular requirements for the basic safety and essential performance of X-ray equipment for computed tomography
As written on the certificate · Line 1 (A2LA 7129.01)

IEC 60601-1; IEC 60601-1-3; IEC 60601-1-6; IEC 62366-1; IEC 60601-1-8; IEC TR 62366-2; IEC 60601-1-11; IEC 60601-2-2; IEC 60601-2-10; IEC 60601-2-18; IEC 60601-2-22; IEC 60601-2-28; IEC 60601-2-36; IEC 60601-2-37; IEC 60601-2-43; IEC 60601-2-44; IEC 60601-2-45; IEC 60601-2-54; IEC 60601-2-57; IEC 80601-2-60; IEC 60601-2-63; IEC 60601-2-65; EN 60601-1; EN 60601-1-3

As written on the certificate · Line 2 (A2LA 7129.01)

EN 60601-1-6; EN 62366-1; EN 60601-1-8; EN 60601-1-11; EN IEC 60601-2-2; EN 60601-2-10; EN 60601-2-18; EN IEC 60601-2-22; EN IEC 60601-2-28 2; EN 60601-2-36; EN 60601-2-37; EN 60601-2-43 2; EN 60601-2-44 2; EN 60601-2-45 2; EN IEC 60601-2-54 2; EN 60601-2-57; EN IEC 80601-2-60; EN 60601-2-63 2; EN 60601-2-65 2; ANSI/AAMI ES 60601-1; ANSI/AAMI/IEC 62366-1; ANSI/AAMI/IEC 60601-1-8; ANSI/AAMI HA 60601-1-11; ANSI AAMI IEC 60601-2-2; CAN/CSA-C22.2 No. 60601-1; CAN/CSA C22.2 No. 60601-1-3 2; CAN/CSA C22.2 No. 62366-1; CAN/CSA C22.2 No. 60601-1-8; CAN/CSA C22.2 No. 60601-2-2; CAN/CSA C22.2 No. 60601-2-10; CAN/CSA C22.2 No. 60601-1-11; CSA C22.2 No. 60601-2-18; CSA C22.2 No. 60601-2-22; CSA C22.2 No. 60601-2-28 2; CSA C22.2 No. 60601-2-36; CSA-C22.2 No. 60601-2-37; CAN/CSA C22.2 No. 60601-2-43 2; CSA C22.2 No. 60601-2-44 2; CAN/CSA C22.2 No. 60601-2-45 2; CAN/CSA-C22.2 No. 60601-2-54 2; CSA C22.2 No. 60601-2-57; CSA C22.2 No. 80601-2-60; CSA C22.2 No. 60601-2-63 2; CSA C22.2 No. 60601-2-65 2

IEC 60601-2-45Medical electrical equipment - Part 2-45: Particular requirements for the basic safety and essential performance of mammographic X-ray equipment and mammographic stereotactic devices
As written on the certificate · Line 1 (A2LA 7129.01)

IEC 60601-1; IEC 60601-1-3; IEC 60601-1-6; IEC 62366-1; IEC 60601-1-8; IEC TR 62366-2; IEC 60601-1-11; IEC 60601-2-2; IEC 60601-2-10; IEC 60601-2-18; IEC 60601-2-22; IEC 60601-2-28; IEC 60601-2-36; IEC 60601-2-37; IEC 60601-2-43; IEC 60601-2-44; IEC 60601-2-45; IEC 60601-2-54; IEC 60601-2-57; IEC 80601-2-60; IEC 60601-2-63; IEC 60601-2-65; EN 60601-1; EN 60601-1-3

As written on the certificate · Line 2 (A2LA 7129.01)

EN 60601-1-6; EN 62366-1; EN 60601-1-8; EN 60601-1-11; EN IEC 60601-2-2; EN 60601-2-10; EN 60601-2-18; EN IEC 60601-2-22; EN IEC 60601-2-28 2; EN 60601-2-36; EN 60601-2-37; EN 60601-2-43 2; EN 60601-2-44 2; EN 60601-2-45 2; EN IEC 60601-2-54 2; EN 60601-2-57; EN IEC 80601-2-60; EN 60601-2-63 2; EN 60601-2-65 2; ANSI/AAMI ES 60601-1; ANSI/AAMI/IEC 62366-1; ANSI/AAMI/IEC 60601-1-8; ANSI/AAMI HA 60601-1-11; ANSI AAMI IEC 60601-2-2; CAN/CSA-C22.2 No. 60601-1; CAN/CSA C22.2 No. 60601-1-3 2; CAN/CSA C22.2 No. 62366-1; CAN/CSA C22.2 No. 60601-1-8; CAN/CSA C22.2 No. 60601-2-2; CAN/CSA C22.2 No. 60601-2-10; CAN/CSA C22.2 No. 60601-1-11; CSA C22.2 No. 60601-2-18; CSA C22.2 No. 60601-2-22; CSA C22.2 No. 60601-2-28 2; CSA C22.2 No. 60601-2-36; CSA-C22.2 No. 60601-2-37; CAN/CSA C22.2 No. 60601-2-43 2; CSA C22.2 No. 60601-2-44 2; CAN/CSA C22.2 No. 60601-2-45 2; CAN/CSA-C22.2 No. 60601-2-54 2; CSA C22.2 No. 60601-2-57; CSA C22.2 No. 80601-2-60; CSA C22.2 No. 60601-2-63 2; CSA C22.2 No. 60601-2-65 2

IEC 60601-2-54Medical electrical equipment - Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy
As written on the certificate · Line 1 (A2LA 7129.01)

IEC 60601-1; IEC 60601-1-3; IEC 60601-1-6; IEC 62366-1; IEC 60601-1-8; IEC TR 62366-2; IEC 60601-1-11; IEC 60601-2-2; IEC 60601-2-10; IEC 60601-2-18; IEC 60601-2-22; IEC 60601-2-28; IEC 60601-2-36; IEC 60601-2-37; IEC 60601-2-43; IEC 60601-2-44; IEC 60601-2-45; IEC 60601-2-54; IEC 60601-2-57; IEC 80601-2-60; IEC 60601-2-63; IEC 60601-2-65; EN 60601-1; EN 60601-1-3

As written on the certificate · Line 2 (A2LA 7129.01)

EN 60601-1-6; EN 62366-1; EN 60601-1-8; EN 60601-1-11; EN IEC 60601-2-2; EN 60601-2-10; EN 60601-2-18; EN IEC 60601-2-22; EN IEC 60601-2-28 2; EN 60601-2-36; EN 60601-2-37; EN 60601-2-43 2; EN 60601-2-44 2; EN 60601-2-45 2; EN IEC 60601-2-54 2; EN 60601-2-57; EN IEC 80601-2-60; EN 60601-2-63 2; EN 60601-2-65 2; ANSI/AAMI ES 60601-1; ANSI/AAMI/IEC 62366-1; ANSI/AAMI/IEC 60601-1-8; ANSI/AAMI HA 60601-1-11; ANSI AAMI IEC 60601-2-2; CAN/CSA-C22.2 No. 60601-1; CAN/CSA C22.2 No. 60601-1-3 2; CAN/CSA C22.2 No. 62366-1; CAN/CSA C22.2 No. 60601-1-8; CAN/CSA C22.2 No. 60601-2-2; CAN/CSA C22.2 No. 60601-2-10; CAN/CSA C22.2 No. 60601-1-11; CSA C22.2 No. 60601-2-18; CSA C22.2 No. 60601-2-22; CSA C22.2 No. 60601-2-28 2; CSA C22.2 No. 60601-2-36; CSA-C22.2 No. 60601-2-37; CAN/CSA C22.2 No. 60601-2-43 2; CSA C22.2 No. 60601-2-44 2; CAN/CSA C22.2 No. 60601-2-45 2; CAN/CSA-C22.2 No. 60601-2-54 2; CSA C22.2 No. 60601-2-57; CSA C22.2 No. 80601-2-60; CSA C22.2 No. 60601-2-63 2; CSA C22.2 No. 60601-2-65 2

IEC 60601-2-57Name not checked yet
As written on the certificate · Line 1 (A2LA 7129.01)

IEC 60601-1; IEC 60601-1-3; IEC 60601-1-6; IEC 62366-1; IEC 60601-1-8; IEC TR 62366-2; IEC 60601-1-11; IEC 60601-2-2; IEC 60601-2-10; IEC 60601-2-18; IEC 60601-2-22; IEC 60601-2-28; IEC 60601-2-36; IEC 60601-2-37; IEC 60601-2-43; IEC 60601-2-44; IEC 60601-2-45; IEC 60601-2-54; IEC 60601-2-57; IEC 80601-2-60; IEC 60601-2-63; IEC 60601-2-65; EN 60601-1; EN 60601-1-3

As written on the certificate · Line 2 (A2LA 7129.01)

EN 60601-1-6; EN 62366-1; EN 60601-1-8; EN 60601-1-11; EN IEC 60601-2-2; EN 60601-2-10; EN 60601-2-18; EN IEC 60601-2-22; EN IEC 60601-2-28 2; EN 60601-2-36; EN 60601-2-37; EN 60601-2-43 2; EN 60601-2-44 2; EN 60601-2-45 2; EN IEC 60601-2-54 2; EN 60601-2-57; EN IEC 80601-2-60; EN 60601-2-63 2; EN 60601-2-65 2; ANSI/AAMI ES 60601-1; ANSI/AAMI/IEC 62366-1; ANSI/AAMI/IEC 60601-1-8; ANSI/AAMI HA 60601-1-11; ANSI AAMI IEC 60601-2-2; CAN/CSA-C22.2 No. 60601-1; CAN/CSA C22.2 No. 60601-1-3 2; CAN/CSA C22.2 No. 62366-1; CAN/CSA C22.2 No. 60601-1-8; CAN/CSA C22.2 No. 60601-2-2; CAN/CSA C22.2 No. 60601-2-10; CAN/CSA C22.2 No. 60601-1-11; CSA C22.2 No. 60601-2-18; CSA C22.2 No. 60601-2-22; CSA C22.2 No. 60601-2-28 2; CSA C22.2 No. 60601-2-36; CSA-C22.2 No. 60601-2-37; CAN/CSA C22.2 No. 60601-2-43 2; CSA C22.2 No. 60601-2-44 2; CAN/CSA C22.2 No. 60601-2-45 2; CAN/CSA-C22.2 No. 60601-2-54 2; CSA C22.2 No. 60601-2-57; CSA C22.2 No. 80601-2-60; CSA C22.2 No. 60601-2-63 2; CSA C22.2 No. 60601-2-65 2

IEC 60601-2-63Name not checked yet
As written on the certificate · Line 1 (A2LA 7129.01)

IEC 60601-1; IEC 60601-1-3; IEC 60601-1-6; IEC 62366-1; IEC 60601-1-8; IEC TR 62366-2; IEC 60601-1-11; IEC 60601-2-2; IEC 60601-2-10; IEC 60601-2-18; IEC 60601-2-22; IEC 60601-2-28; IEC 60601-2-36; IEC 60601-2-37; IEC 60601-2-43; IEC 60601-2-44; IEC 60601-2-45; IEC 60601-2-54; IEC 60601-2-57; IEC 80601-2-60; IEC 60601-2-63; IEC 60601-2-65; EN 60601-1; EN 60601-1-3

As written on the certificate · Line 2 (A2LA 7129.01)

EN 60601-1-6; EN 62366-1; EN 60601-1-8; EN 60601-1-11; EN IEC 60601-2-2; EN 60601-2-10; EN 60601-2-18; EN IEC 60601-2-22; EN IEC 60601-2-28 2; EN 60601-2-36; EN 60601-2-37; EN 60601-2-43 2; EN 60601-2-44 2; EN 60601-2-45 2; EN IEC 60601-2-54 2; EN 60601-2-57; EN IEC 80601-2-60; EN 60601-2-63 2; EN 60601-2-65 2; ANSI/AAMI ES 60601-1; ANSI/AAMI/IEC 62366-1; ANSI/AAMI/IEC 60601-1-8; ANSI/AAMI HA 60601-1-11; ANSI AAMI IEC 60601-2-2; CAN/CSA-C22.2 No. 60601-1; CAN/CSA C22.2 No. 60601-1-3 2; CAN/CSA C22.2 No. 62366-1; CAN/CSA C22.2 No. 60601-1-8; CAN/CSA C22.2 No. 60601-2-2; CAN/CSA C22.2 No. 60601-2-10; CAN/CSA C22.2 No. 60601-1-11; CSA C22.2 No. 60601-2-18; CSA C22.2 No. 60601-2-22; CSA C22.2 No. 60601-2-28 2; CSA C22.2 No. 60601-2-36; CSA-C22.2 No. 60601-2-37; CAN/CSA C22.2 No. 60601-2-43 2; CSA C22.2 No. 60601-2-44 2; CAN/CSA C22.2 No. 60601-2-45 2; CAN/CSA-C22.2 No. 60601-2-54 2; CSA C22.2 No. 60601-2-57; CSA C22.2 No. 80601-2-60; CSA C22.2 No. 60601-2-63 2; CSA C22.2 No. 60601-2-65 2

IEC 60601-2-65Name not checked yet
As written on the certificate · Line 1 (A2LA 7129.01)

IEC 60601-1; IEC 60601-1-3; IEC 60601-1-6; IEC 62366-1; IEC 60601-1-8; IEC TR 62366-2; IEC 60601-1-11; IEC 60601-2-2; IEC 60601-2-10; IEC 60601-2-18; IEC 60601-2-22; IEC 60601-2-28; IEC 60601-2-36; IEC 60601-2-37; IEC 60601-2-43; IEC 60601-2-44; IEC 60601-2-45; IEC 60601-2-54; IEC 60601-2-57; IEC 80601-2-60; IEC 60601-2-63; IEC 60601-2-65; EN 60601-1; EN 60601-1-3

As written on the certificate · Line 2 (A2LA 7129.01)

EN 60601-1-6; EN 62366-1; EN 60601-1-8; EN 60601-1-11; EN IEC 60601-2-2; EN 60601-2-10; EN 60601-2-18; EN IEC 60601-2-22; EN IEC 60601-2-28 2; EN 60601-2-36; EN 60601-2-37; EN 60601-2-43 2; EN 60601-2-44 2; EN 60601-2-45 2; EN IEC 60601-2-54 2; EN 60601-2-57; EN IEC 80601-2-60; EN 60601-2-63 2; EN 60601-2-65 2; ANSI/AAMI ES 60601-1; ANSI/AAMI/IEC 62366-1; ANSI/AAMI/IEC 60601-1-8; ANSI/AAMI HA 60601-1-11; ANSI AAMI IEC 60601-2-2; CAN/CSA-C22.2 No. 60601-1; CAN/CSA C22.2 No. 60601-1-3 2; CAN/CSA C22.2 No. 62366-1; CAN/CSA C22.2 No. 60601-1-8; CAN/CSA C22.2 No. 60601-2-2; CAN/CSA C22.2 No. 60601-2-10; CAN/CSA C22.2 No. 60601-1-11; CSA C22.2 No. 60601-2-18; CSA C22.2 No. 60601-2-22; CSA C22.2 No. 60601-2-28 2; CSA C22.2 No. 60601-2-36; CSA-C22.2 No. 60601-2-37; CAN/CSA C22.2 No. 60601-2-43 2; CSA C22.2 No. 60601-2-44 2; CAN/CSA C22.2 No. 60601-2-45 2; CAN/CSA-C22.2 No. 60601-2-54 2; CSA C22.2 No. 60601-2-57; CSA C22.2 No. 80601-2-60; CSA C22.2 No. 60601-2-63 2; CSA C22.2 No. 60601-2-65 2

IEC 61010 series

IEC 61010-1Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
As written on the certificate · Line 3 (A2LA 7129.01)

IEC 61010-1; IEC 61010-2-010; IEC 61010-2-011; IEC 61010-2-020; IEC 61010-2-030; IEC 61010-2-040; IEC 61010-2-051; IEC 61010-2-081; IEC 61010-2-091; IEC 61010-2-101; EN 61010-1; EN IEC 61010-2-010; EN IEC 61010-2-011; EN 61010-2-020; EN IEC 61010-2-030; EN IEC 61010-2-040; EN IEC 61010-2-051; EN IEC 61010-2-081; EN IEC 61010-2-091; EN IEC 61010-2-101; ANSI UL 61010-1; CAN/CSA-C22.2 No. 61010-1; UL 61010-2-010; CSA C22.1 No. 61010-2-010; UL 61010-2-011; CSA C22.2 No. 61010-2-011; UL 61010-2-020; CSA C22.2 No. 61010-2-020; UL 61010-2-030; CSA C22.2 No. 61010-2-030; UL 61010-2-040; CSA C22.2 No. 61010-2-040; UL 61010-2-051; CSA C22.2 No. 61010-2-051; UL 61010-2-081; CSA C22.2 No. 61010-2-081; UL 61010-2-091; CSA C22.2 No. 61010-2-091; UL 61010-2-101; CAN/CSA-C22.2 No. 61010-2-101; IEC 60825-1; EN 60825-1; CAN/CSA-E60825-1

As written on the certificate · Line 4 (A2LA 7129.01)

IEC 60601-1; EN 60601-1; ANSI/AAMI ES60601-1; CAN/CSA-C22.2 NO. 60601-1; IEC 60601-2-2; EN 60601-2-2; CSA C22.2 NO. 60601-2-2; IEC 61010-1; EN 61010-1; ANSI UL 61010-1; CAN/CSA-C22.2 No. 61010-1

IEC 61010-2-010Name not checked yet
As written on the certificate · Line 3 (A2LA 7129.01)

IEC 61010-1; IEC 61010-2-010; IEC 61010-2-011; IEC 61010-2-020; IEC 61010-2-030; IEC 61010-2-040; IEC 61010-2-051; IEC 61010-2-081; IEC 61010-2-091; IEC 61010-2-101; EN 61010-1; EN IEC 61010-2-010; EN IEC 61010-2-011; EN 61010-2-020; EN IEC 61010-2-030; EN IEC 61010-2-040; EN IEC 61010-2-051; EN IEC 61010-2-081; EN IEC 61010-2-091; EN IEC 61010-2-101; ANSI UL 61010-1; CAN/CSA-C22.2 No. 61010-1; UL 61010-2-010; CSA C22.1 No. 61010-2-010; UL 61010-2-011; CSA C22.2 No. 61010-2-011; UL 61010-2-020; CSA C22.2 No. 61010-2-020; UL 61010-2-030; CSA C22.2 No. 61010-2-030; UL 61010-2-040; CSA C22.2 No. 61010-2-040; UL 61010-2-051; CSA C22.2 No. 61010-2-051; UL 61010-2-081; CSA C22.2 No. 61010-2-081; UL 61010-2-091; CSA C22.2 No. 61010-2-091; UL 61010-2-101; CAN/CSA-C22.2 No. 61010-2-101; IEC 60825-1; EN 60825-1; CAN/CSA-E60825-1

IEC 61010-2-011Name not checked yet
As written on the certificate · Line 3 (A2LA 7129.01)

IEC 61010-1; IEC 61010-2-010; IEC 61010-2-011; IEC 61010-2-020; IEC 61010-2-030; IEC 61010-2-040; IEC 61010-2-051; IEC 61010-2-081; IEC 61010-2-091; IEC 61010-2-101; EN 61010-1; EN IEC 61010-2-010; EN IEC 61010-2-011; EN 61010-2-020; EN IEC 61010-2-030; EN IEC 61010-2-040; EN IEC 61010-2-051; EN IEC 61010-2-081; EN IEC 61010-2-091; EN IEC 61010-2-101; ANSI UL 61010-1; CAN/CSA-C22.2 No. 61010-1; UL 61010-2-010; CSA C22.1 No. 61010-2-010; UL 61010-2-011; CSA C22.2 No. 61010-2-011; UL 61010-2-020; CSA C22.2 No. 61010-2-020; UL 61010-2-030; CSA C22.2 No. 61010-2-030; UL 61010-2-040; CSA C22.2 No. 61010-2-040; UL 61010-2-051; CSA C22.2 No. 61010-2-051; UL 61010-2-081; CSA C22.2 No. 61010-2-081; UL 61010-2-091; CSA C22.2 No. 61010-2-091; UL 61010-2-101; CAN/CSA-C22.2 No. 61010-2-101; IEC 60825-1; EN 60825-1; CAN/CSA-E60825-1

IEC 61010-2-020Name not checked yet
As written on the certificate · Line 3 (A2LA 7129.01)

IEC 61010-1; IEC 61010-2-010; IEC 61010-2-011; IEC 61010-2-020; IEC 61010-2-030; IEC 61010-2-040; IEC 61010-2-051; IEC 61010-2-081; IEC 61010-2-091; IEC 61010-2-101; EN 61010-1; EN IEC 61010-2-010; EN IEC 61010-2-011; EN 61010-2-020; EN IEC 61010-2-030; EN IEC 61010-2-040; EN IEC 61010-2-051; EN IEC 61010-2-081; EN IEC 61010-2-091; EN IEC 61010-2-101; ANSI UL 61010-1; CAN/CSA-C22.2 No. 61010-1; UL 61010-2-010; CSA C22.1 No. 61010-2-010; UL 61010-2-011; CSA C22.2 No. 61010-2-011; UL 61010-2-020; CSA C22.2 No. 61010-2-020; UL 61010-2-030; CSA C22.2 No. 61010-2-030; UL 61010-2-040; CSA C22.2 No. 61010-2-040; UL 61010-2-051; CSA C22.2 No. 61010-2-051; UL 61010-2-081; CSA C22.2 No. 61010-2-081; UL 61010-2-091; CSA C22.2 No. 61010-2-091; UL 61010-2-101; CAN/CSA-C22.2 No. 61010-2-101; IEC 60825-1; EN 60825-1; CAN/CSA-E60825-1

IEC 61010-2-030Name not checked yet
As written on the certificate · Line 3 (A2LA 7129.01)

IEC 61010-1; IEC 61010-2-010; IEC 61010-2-011; IEC 61010-2-020; IEC 61010-2-030; IEC 61010-2-040; IEC 61010-2-051; IEC 61010-2-081; IEC 61010-2-091; IEC 61010-2-101; EN 61010-1; EN IEC 61010-2-010; EN IEC 61010-2-011; EN 61010-2-020; EN IEC 61010-2-030; EN IEC 61010-2-040; EN IEC 61010-2-051; EN IEC 61010-2-081; EN IEC 61010-2-091; EN IEC 61010-2-101; ANSI UL 61010-1; CAN/CSA-C22.2 No. 61010-1; UL 61010-2-010; CSA C22.1 No. 61010-2-010; UL 61010-2-011; CSA C22.2 No. 61010-2-011; UL 61010-2-020; CSA C22.2 No. 61010-2-020; UL 61010-2-030; CSA C22.2 No. 61010-2-030; UL 61010-2-040; CSA C22.2 No. 61010-2-040; UL 61010-2-051; CSA C22.2 No. 61010-2-051; UL 61010-2-081; CSA C22.2 No. 61010-2-081; UL 61010-2-091; CSA C22.2 No. 61010-2-091; UL 61010-2-101; CAN/CSA-C22.2 No. 61010-2-101; IEC 60825-1; EN 60825-1; CAN/CSA-E60825-1

IEC 61010-2-040Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-040: Particular requirements for sterilizers and washer-disinfectors used to treat medical materials
As written on the certificate · Line 3 (A2LA 7129.01)

IEC 61010-1; IEC 61010-2-010; IEC 61010-2-011; IEC 61010-2-020; IEC 61010-2-030; IEC 61010-2-040; IEC 61010-2-051; IEC 61010-2-081; IEC 61010-2-091; IEC 61010-2-101; EN 61010-1; EN IEC 61010-2-010; EN IEC 61010-2-011; EN 61010-2-020; EN IEC 61010-2-030; EN IEC 61010-2-040; EN IEC 61010-2-051; EN IEC 61010-2-081; EN IEC 61010-2-091; EN IEC 61010-2-101; ANSI UL 61010-1; CAN/CSA-C22.2 No. 61010-1; UL 61010-2-010; CSA C22.1 No. 61010-2-010; UL 61010-2-011; CSA C22.2 No. 61010-2-011; UL 61010-2-020; CSA C22.2 No. 61010-2-020; UL 61010-2-030; CSA C22.2 No. 61010-2-030; UL 61010-2-040; CSA C22.2 No. 61010-2-040; UL 61010-2-051; CSA C22.2 No. 61010-2-051; UL 61010-2-081; CSA C22.2 No. 61010-2-081; UL 61010-2-091; CSA C22.2 No. 61010-2-091; UL 61010-2-101; CAN/CSA-C22.2 No. 61010-2-101; IEC 60825-1; EN 60825-1; CAN/CSA-E60825-1

IEC 61010-2-051Name not checked yet
As written on the certificate · Line 3 (A2LA 7129.01)

IEC 61010-1; IEC 61010-2-010; IEC 61010-2-011; IEC 61010-2-020; IEC 61010-2-030; IEC 61010-2-040; IEC 61010-2-051; IEC 61010-2-081; IEC 61010-2-091; IEC 61010-2-101; EN 61010-1; EN IEC 61010-2-010; EN IEC 61010-2-011; EN 61010-2-020; EN IEC 61010-2-030; EN IEC 61010-2-040; EN IEC 61010-2-051; EN IEC 61010-2-081; EN IEC 61010-2-091; EN IEC 61010-2-101; ANSI UL 61010-1; CAN/CSA-C22.2 No. 61010-1; UL 61010-2-010; CSA C22.1 No. 61010-2-010; UL 61010-2-011; CSA C22.2 No. 61010-2-011; UL 61010-2-020; CSA C22.2 No. 61010-2-020; UL 61010-2-030; CSA C22.2 No. 61010-2-030; UL 61010-2-040; CSA C22.2 No. 61010-2-040; UL 61010-2-051; CSA C22.2 No. 61010-2-051; UL 61010-2-081; CSA C22.2 No. 61010-2-081; UL 61010-2-091; CSA C22.2 No. 61010-2-091; UL 61010-2-101; CAN/CSA-C22.2 No. 61010-2-101; IEC 60825-1; EN 60825-1; CAN/CSA-E60825-1

IEC 61010-2-081Name not checked yet
As written on the certificate · Line 3 (A2LA 7129.01)

IEC 61010-1; IEC 61010-2-010; IEC 61010-2-011; IEC 61010-2-020; IEC 61010-2-030; IEC 61010-2-040; IEC 61010-2-051; IEC 61010-2-081; IEC 61010-2-091; IEC 61010-2-101; EN 61010-1; EN IEC 61010-2-010; EN IEC 61010-2-011; EN 61010-2-020; EN IEC 61010-2-030; EN IEC 61010-2-040; EN IEC 61010-2-051; EN IEC 61010-2-081; EN IEC 61010-2-091; EN IEC 61010-2-101; ANSI UL 61010-1; CAN/CSA-C22.2 No. 61010-1; UL 61010-2-010; CSA C22.1 No. 61010-2-010; UL 61010-2-011; CSA C22.2 No. 61010-2-011; UL 61010-2-020; CSA C22.2 No. 61010-2-020; UL 61010-2-030; CSA C22.2 No. 61010-2-030; UL 61010-2-040; CSA C22.2 No. 61010-2-040; UL 61010-2-051; CSA C22.2 No. 61010-2-051; UL 61010-2-081; CSA C22.2 No. 61010-2-081; UL 61010-2-091; CSA C22.2 No. 61010-2-091; UL 61010-2-101; CAN/CSA-C22.2 No. 61010-2-101; IEC 60825-1; EN 60825-1; CAN/CSA-E60825-1

IEC 61010-2-091Name not checked yet
As written on the certificate · Line 3 (A2LA 7129.01)

IEC 61010-1; IEC 61010-2-010; IEC 61010-2-011; IEC 61010-2-020; IEC 61010-2-030; IEC 61010-2-040; IEC 61010-2-051; IEC 61010-2-081; IEC 61010-2-091; IEC 61010-2-101; EN 61010-1; EN IEC 61010-2-010; EN IEC 61010-2-011; EN 61010-2-020; EN IEC 61010-2-030; EN IEC 61010-2-040; EN IEC 61010-2-051; EN IEC 61010-2-081; EN IEC 61010-2-091; EN IEC 61010-2-101; ANSI UL 61010-1; CAN/CSA-C22.2 No. 61010-1; UL 61010-2-010; CSA C22.1 No. 61010-2-010; UL 61010-2-011; CSA C22.2 No. 61010-2-011; UL 61010-2-020; CSA C22.2 No. 61010-2-020; UL 61010-2-030; CSA C22.2 No. 61010-2-030; UL 61010-2-040; CSA C22.2 No. 61010-2-040; UL 61010-2-051; CSA C22.2 No. 61010-2-051; UL 61010-2-081; CSA C22.2 No. 61010-2-081; UL 61010-2-091; CSA C22.2 No. 61010-2-091; UL 61010-2-101; CAN/CSA-C22.2 No. 61010-2-101; IEC 60825-1; EN 60825-1; CAN/CSA-E60825-1

IEC 61010-2-101Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-101: Particular requirements for in vitro diagnostic (IVD) medical equipment
As written on the certificate · Line 3 (A2LA 7129.01)

IEC 61010-1; IEC 61010-2-010; IEC 61010-2-011; IEC 61010-2-020; IEC 61010-2-030; IEC 61010-2-040; IEC 61010-2-051; IEC 61010-2-081; IEC 61010-2-091; IEC 61010-2-101; EN 61010-1; EN IEC 61010-2-010; EN IEC 61010-2-011; EN 61010-2-020; EN IEC 61010-2-030; EN IEC 61010-2-040; EN IEC 61010-2-051; EN IEC 61010-2-081; EN IEC 61010-2-091; EN IEC 61010-2-101; ANSI UL 61010-1; CAN/CSA-C22.2 No. 61010-1; UL 61010-2-010; CSA C22.1 No. 61010-2-010; UL 61010-2-011; CSA C22.2 No. 61010-2-011; UL 61010-2-020; CSA C22.2 No. 61010-2-020; UL 61010-2-030; CSA C22.2 No. 61010-2-030; UL 61010-2-040; CSA C22.2 No. 61010-2-040; UL 61010-2-051; CSA C22.2 No. 61010-2-051; UL 61010-2-081; CSA C22.2 No. 61010-2-081; UL 61010-2-091; CSA C22.2 No. 61010-2-091; UL 61010-2-101; CAN/CSA-C22.2 No. 61010-2-101; IEC 60825-1; EN 60825-1; CAN/CSA-E60825-1

IEC

IEC 60825-1Name not checked yet
As written on the certificate · Line 3 (A2LA 7129.01)

IEC 61010-1; IEC 61010-2-010; IEC 61010-2-011; IEC 61010-2-020; IEC 61010-2-030; IEC 61010-2-040; IEC 61010-2-051; IEC 61010-2-081; IEC 61010-2-091; IEC 61010-2-101; EN 61010-1; EN IEC 61010-2-010; EN IEC 61010-2-011; EN 61010-2-020; EN IEC 61010-2-030; EN IEC 61010-2-040; EN IEC 61010-2-051; EN IEC 61010-2-081; EN IEC 61010-2-091; EN IEC 61010-2-101; ANSI UL 61010-1; CAN/CSA-C22.2 No. 61010-1; UL 61010-2-010; CSA C22.1 No. 61010-2-010; UL 61010-2-011; CSA C22.2 No. 61010-2-011; UL 61010-2-020; CSA C22.2 No. 61010-2-020; UL 61010-2-030; CSA C22.2 No. 61010-2-030; UL 61010-2-040; CSA C22.2 No. 61010-2-040; UL 61010-2-051; CSA C22.2 No. 61010-2-051; UL 61010-2-081; CSA C22.2 No. 61010-2-081; UL 61010-2-091; CSA C22.2 No. 61010-2-091; UL 61010-2-101; CAN/CSA-C22.2 No. 61010-2-101; IEC 60825-1; EN 60825-1; CAN/CSA-E60825-1

IEC 62366-1Name not checked yet
As written on the certificate · Line 1 (A2LA 7129.01)

IEC 60601-1; IEC 60601-1-3; IEC 60601-1-6; IEC 62366-1; IEC 60601-1-8; IEC TR 62366-2; IEC 60601-1-11; IEC 60601-2-2; IEC 60601-2-10; IEC 60601-2-18; IEC 60601-2-22; IEC 60601-2-28; IEC 60601-2-36; IEC 60601-2-37; IEC 60601-2-43; IEC 60601-2-44; IEC 60601-2-45; IEC 60601-2-54; IEC 60601-2-57; IEC 80601-2-60; IEC 60601-2-63; IEC 60601-2-65; EN 60601-1; EN 60601-1-3

As written on the certificate · Line 2 (A2LA 7129.01)

EN 60601-1-6; EN 62366-1; EN 60601-1-8; EN 60601-1-11; EN IEC 60601-2-2; EN 60601-2-10; EN 60601-2-18; EN IEC 60601-2-22; EN IEC 60601-2-28 2; EN 60601-2-36; EN 60601-2-37; EN 60601-2-43 2; EN 60601-2-44 2; EN 60601-2-45 2; EN IEC 60601-2-54 2; EN 60601-2-57; EN IEC 80601-2-60; EN 60601-2-63 2; EN 60601-2-65 2; ANSI/AAMI ES 60601-1; ANSI/AAMI/IEC 62366-1; ANSI/AAMI/IEC 60601-1-8; ANSI/AAMI HA 60601-1-11; ANSI AAMI IEC 60601-2-2; CAN/CSA-C22.2 No. 60601-1; CAN/CSA C22.2 No. 60601-1-3 2; CAN/CSA C22.2 No. 62366-1; CAN/CSA C22.2 No. 60601-1-8; CAN/CSA C22.2 No. 60601-2-2; CAN/CSA C22.2 No. 60601-2-10; CAN/CSA C22.2 No. 60601-1-11; CSA C22.2 No. 60601-2-18; CSA C22.2 No. 60601-2-22; CSA C22.2 No. 60601-2-28 2; CSA C22.2 No. 60601-2-36; CSA-C22.2 No. 60601-2-37; CAN/CSA C22.2 No. 60601-2-43 2; CSA C22.2 No. 60601-2-44 2; CAN/CSA C22.2 No. 60601-2-45 2; CAN/CSA-C22.2 No. 60601-2-54 2; CSA C22.2 No. 60601-2-57; CSA C22.2 No. 80601-2-60; CSA C22.2 No. 60601-2-63 2; CSA C22.2 No. 60601-2-65 2

IEC 80601-2-60Name not checked yet
As written on the certificate · Line 1 (A2LA 7129.01)

IEC 60601-1; IEC 60601-1-3; IEC 60601-1-6; IEC 62366-1; IEC 60601-1-8; IEC TR 62366-2; IEC 60601-1-11; IEC 60601-2-2; IEC 60601-2-10; IEC 60601-2-18; IEC 60601-2-22; IEC 60601-2-28; IEC 60601-2-36; IEC 60601-2-37; IEC 60601-2-43; IEC 60601-2-44; IEC 60601-2-45; IEC 60601-2-54; IEC 60601-2-57; IEC 80601-2-60; IEC 60601-2-63; IEC 60601-2-65; EN 60601-1; EN 60601-1-3

As written on the certificate · Line 2 (A2LA 7129.01)

EN 60601-1-6; EN 62366-1; EN 60601-1-8; EN 60601-1-11; EN IEC 60601-2-2; EN 60601-2-10; EN 60601-2-18; EN IEC 60601-2-22; EN IEC 60601-2-28 2; EN 60601-2-36; EN 60601-2-37; EN 60601-2-43 2; EN 60601-2-44 2; EN 60601-2-45 2; EN IEC 60601-2-54 2; EN 60601-2-57; EN IEC 80601-2-60; EN 60601-2-63 2; EN 60601-2-65 2; ANSI/AAMI ES 60601-1; ANSI/AAMI/IEC 62366-1; ANSI/AAMI/IEC 60601-1-8; ANSI/AAMI HA 60601-1-11; ANSI AAMI IEC 60601-2-2; CAN/CSA-C22.2 No. 60601-1; CAN/CSA C22.2 No. 60601-1-3 2; CAN/CSA C22.2 No. 62366-1; CAN/CSA C22.2 No. 60601-1-8; CAN/CSA C22.2 No. 60601-2-2; CAN/CSA C22.2 No. 60601-2-10; CAN/CSA C22.2 No. 60601-1-11; CSA C22.2 No. 60601-2-18; CSA C22.2 No. 60601-2-22; CSA C22.2 No. 60601-2-28 2; CSA C22.2 No. 60601-2-36; CSA-C22.2 No. 60601-2-37; CAN/CSA C22.2 No. 60601-2-43 2; CSA C22.2 No. 60601-2-44 2; CAN/CSA C22.2 No. 60601-2-45 2; CAN/CSA-C22.2 No. 60601-2-54 2; CSA C22.2 No. 60601-2-57; CSA C22.2 No. 80601-2-60; CSA C22.2 No. 60601-2-63 2; CSA C22.2 No. 60601-2-65 2

Scope as published by A2LA

5 lines
A2LA

ISO/IEC 17025

Active

7129.01

The scope document we hold says it is valid until 2028-01-31.

View scope

Accredited scope, certificate 7129.01

LineDisciplineMethodMatrixRange
1electricalIEC 60601-1; IEC 60601-1-3; IEC 60601-1-6; IEC 62366-1; IEC 60601-1-8; IEC TR 62366-2; IEC 60601-1-11; IEC 60601-2-2; IEC 60601-2-10; IEC 60601-2-18; IEC 60601-2-22; IEC 60601-2-28; IEC 60601-2-36; IEC 60601-2-37; IEC 60601-2-43; IEC 60601-2-44; IEC 60601-2-45; IEC 60601-2-54; IEC 60601-2-57; IEC 80601-2-60; IEC 60601-2-63; IEC 60601-2-65; EN 60601-1; EN 60601-1-3--
2electricalEN 60601-1-6; EN 62366-1; EN 60601-1-8; EN 60601-1-11; EN IEC 60601-2-2; EN 60601-2-10; EN 60601-2-18; EN IEC 60601-2-22; EN IEC 60601-2-28 2; EN 60601-2-36; EN 60601-2-37; EN 60601-2-43 2; EN 60601-2-44 2; EN 60601-2-45 2; EN IEC 60601-2-54 2; EN 60601-2-57; EN IEC 80601-2-60; EN 60601-2-63 2; EN 60601-2-65 2; ANSI/AAMI ES 60601-1; ANSI/AAMI/IEC 62366-1; ANSI/AAMI/IEC 60601-1-8; ANSI/AAMI HA 60601-1-11; ANSI AAMI IEC 60601-2-2; CAN/CSA-C22.2 No. 60601-1; CAN/CSA C22.2 No. 60601-1-3 2; CAN/CSA C22.2 No. 62366-1; CAN/CSA C22.2 No. 60601-1-8; CAN/CSA C22.2 No. 60601-2-2; CAN/CSA C22.2 No. 60601-2-10; CAN/CSA C22.2 No. 60601-1-11; CSA C22.2 No. 60601-2-18; CSA C22.2 No. 60601-2-22; CSA C22.2 No. 60601-2-28 2; CSA C22.2 No. 60601-2-36; CSA-C22.2 No. 60601-2-37; CAN/CSA C22.2 No. 60601-2-43 2; CSA C22.2 No. 60601-2-44 2; CAN/CSA C22.2 No. 60601-2-45 2; CAN/CSA-C22.2 No. 60601-2-54 2; CSA C22.2 No. 60601-2-57; CSA C22.2 No. 80601-2-60; CSA C22.2 No. 60601-2-63 2; CSA C22.2 No. 60601-2-65 2Medical equipment, electrical safety and EMC-
3electricalIEC 61010-1; IEC 61010-2-010; IEC 61010-2-011; IEC 61010-2-020; IEC 61010-2-030; IEC 61010-2-040; IEC 61010-2-051; IEC 61010-2-081; IEC 61010-2-091; IEC 61010-2-101; EN 61010-1; EN IEC 61010-2-010; EN IEC 61010-2-011; EN 61010-2-020; EN IEC 61010-2-030; EN IEC 61010-2-040; EN IEC 61010-2-051; EN IEC 61010-2-081; EN IEC 61010-2-091; EN IEC 61010-2-101; ANSI UL 61010-1; CAN/CSA-C22.2 No. 61010-1; UL 61010-2-010; CSA C22.1 No. 61010-2-010; UL 61010-2-011; CSA C22.2 No. 61010-2-011; UL 61010-2-020; CSA C22.2 No. 61010-2-020; UL 61010-2-030; CSA C22.2 No. 61010-2-030; UL 61010-2-040; CSA C22.2 No. 61010-2-040; UL 61010-2-051; CSA C22.2 No. 61010-2-051; UL 61010-2-081; CSA C22.2 No. 61010-2-081; UL 61010-2-091; CSA C22.2 No. 61010-2-091; UL 61010-2-101; CAN/CSA-C22.2 No. 61010-2-101; IEC 60825-1; EN 60825-1; CAN/CSA-E60825-1Testing and Measuring Equipment; Laser Equipment-
4electricalIEC 60601-1; EN 60601-1; ANSI/AAMI ES60601-1; CAN/CSA-C22.2 NO. 60601-1; IEC 60601-2-2; EN 60601-2-2; CSA C22.2 NO. 60601-2-2; IEC 61010-1; EN 61010-1; ANSI UL 61010-1; CAN/CSA-C22.2 No. 61010-1--
5electrical
For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation. Accredited Laboratory A2LA has accredited SGS-CSTC STANDARD TECHNICAL SERVICES CO., LTD. WUHAN BRANCH Wuhan, People’s Republic of China for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This laboratory also meets A2LA R256 – Specific Program Requirements. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 24th day of December 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 7129.01 Valid to January 31, 2028

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.