Registers refreshed 2026-11-08.See refresh dates
United States

SensoScientific

685 Cochran Street, Suite 200, 93065, Simi Valley, CA, United States

Visit website
A2LA 3766.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
3
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 3 scope lines.

A2LA certificate 3766.01 · 3 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3766.01) 09/11/2025 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 SENSOSCIENTIFIC, INC. 685 Cochran Street, Suite 200 Simi Valley, CA 93065 Michael Terpapyan Phone: 323 804 4853 CALIBRATION Valid To: July 31, 2027 Certificate Number: 3766.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations1, 4: I. Thermodynamics Parameter/Equipment Range CMC2, 5 (±) Comments Temperature3 – Measure and Measuring Devices (-40 to 80) °C (-70 to 160) °C (-35 to 150) °C (-95 to 140) °C (-200 to 160) °C (-40 to 80) °C 0.40 °C 0.12 °C 0.41 °C 0.072 °C 0.14 °C 0.51 °C Chamber with temperature - humidity sensor Chamber with PRT Bath with PRT and probe Dry block with PRT and probe Temperature field calibration with PRT sensor Field calibration with temperature - humidity sensor Humidity3 – Measure and Measuring Devices (20 to 80) % RH (15 to 90) % RH 1.5 % RH 2.0 % RH Chamber with temperature - humidity sensor Field calibration with temperature - humidity sensor ___________________________ 1 This laboratory offers commercial calibration service.
-200 to 160 °C
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3766.01) 09/11/2025 Page 2 of 2 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the Calibration and Measurement Capability Uncertainty (CMC) found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 This scope meets A2LA’s P112 Flexible Scope Policy. 5 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
3ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

685 Cochran Street, Suite 200, Simi Valley, CA, 93065, US

34.26774, -118.75381

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.