Cook Research Incorporated (CRI)
1 Geddes Way, 47906, West Lafayette, IN, United States
Visit website- Accredited standards
- 54
- A2LA certificates
- 3
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 54 standard numbers and the 22 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM27
ASTM A938
ASTM E8Standard Test Methods for Tension Testing of Metallic Materials
ASTM E1356
ASTM F640
ASTM F1828
ASTM F2004
ASTM F2052
ASTM F2081
ASTM F2082
ASTM F2119
ASTM F2129
ASTM F2182
Show all 27
ASTM F2213
ASTM F2477
ASTM F2516
ASTM F2606
ASTM F2743
ASTM F2942Exclusion
Limits written next to it
ASTM F2942 (Excluding A3)
ASTM F3044
ASTM F3067
ASTM F3211
ASTM F3320
ASTM F3505
ASTM G5
ASTM G31
ASTM G59
ASTM G71
ISO11
ISO 5084Textiles - Determination of thickness of textiles and textile products
ISO 7198Cardiovascular implants and extracorporeal systems - Vascular prostheses - Tubular vascular grafts and vascular patches
ISO 9626Stainless steel needle tubing for the manufacture of medical devices - Requirements and test methods
ISO 10555-1Intravascular catheters - Sterile and single-use catheters - Part 1: General requirements
ISO 10555-4Intravascular catheters - Sterile and single-use catheters - Part 4: Balloon dilatation catheters
ISO 10993-4Biological evaluation of medical devices - Part 4: Selection of tests for interactions with blood
ISO 11070Sterile single-use intravascular introducers, dilators and guidewires
ISO 16428Implants for surgery - Test solutions and environmental conditions for static and dynamic corrosion tests on implantable materials and medical devices
ISO 20695Enteral feeding systems - Design and testing
ISO 20696Sterile urethral catheters for single use
ISO 20697Sterile drainage catheters and accessory devices for single use
IEC 60601 series5
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 60601-2-2
IEC 60601-2-18
IEC 60601-2-21
IEC 60601-2-182
IEC 61000 series3
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
ISO 25539 series3
ISO 25539-1Cardiovascular implants - Endovascular devices - Part 1: Endovascular prostheses
ISO 25539-2Cardiovascular implants - Endovascular devices - Part 2: Vascular stents
ISO 25539-3Cardiovascular implants - Endovascular devices - Part 3: Vena cava filters
ISO 8600 series3
ISO 8600-1Endoscopes - Medical endoscopes and endotherapy devices - Part 1: General requirements
ISO 8600-3Endoscopes - Medical endoscopes and endotherapy devices - Part 3: Determination of field of view and direction of view of endoscopes with optics
ISO 8600-6Endoscopes - Medical endoscopes and endotherapy devices - Part 6: Vocabulary
Other standards2
EN 13868
USP 788
ASTM A938; ISO 25539-1; ISO 25539-2; ISO 25539-3; TORQ-553
ISO 10555-4; ISO 25539-1; ISO 25539-2; PRES-197; ASTM E8 / E8M; ASTM F2516; ASTM F2606; ASTM F1828; ISO 20695; ISO 20696; ISO 20697; ISO 7198; ISO 11070; ISO 10555-1; ISO 25539-1; ISO 25539-2; ISO 25539-3; JIS T 3215; JIS T 3216; JIS T 3229; JIS T 3242; JIS T 3245; JIS T 3246; JIS T 3247; JIS T 3260; JIS T 3268; JIS T 3270; PULT-210; ASTM F640; ISO 25539-1; ISO 25539-2; ISO 25539-3; RAD-01; ASTM F3067; ISO 25539-1; ISO 25539-2; ISO 25539-3; RF-300; ASTM F2743; ASTM F3320; PROF-01
ISO 25539-2; ISO 25539-3; ECOR-001; ISO 25539-1; ISO 25539-2; ISO 25539-3; DPLY-04; ASTM E1356; ASTM F2004; DSC-438; ECHO-01; ISO 7198; ISO 25539-1; ISO 25539-2; ISO 25539-3; EXAM-100; ISO 5084; ISO 7198; ISO 25539-1; MEAS-825; BS EN 13868; ISO 7198; ISO 20697; ISO 25539-1; ISO 25539-2; ASTM F3505; MEAS-829; ASTM F3211; ASTM F2477; ISO 7198; ISO 25539-1; ISO 25539-2; FATG-320; ASTM F3211; ASTM F2942; ISO 25539-2; ISO 25539-3; FATG-401
ISO 25539-1; ISO 25539-2; ISO 25539-3; FATG-500 Lab Developed Method; FATG-600 Lab Developed Method; FATG-610 Lab Developed Method; FATG-800 Lab Developed Method; ASTM F3211; ASTM F2942 (Excluding A3); FATG-700 Lab Developed Method; ASTM F3211; ASTM F2942; FATG-900 Lab Developed Method; BS EN 13868; ISO 10555-1; ISO 7198; ISO 25539-1; ISO 25539-2; ISO 20695; ISO 20696; ISO 20697; FLOW-225 Lab Developed Method; ANSI/AAMI VP20; ISO 10555-1; ISO 20695; ISO 20696; ISO 20697; ISO 7198; ISO 25539-1; ASTM F1828; FLOW-302 Lab Developed Method; ASTM F2052; ASTM F2213; ASTM F2182; ASTM F2119; MRI-400 Lab Developed Method
QCA-01; HISTO-01; ISO 10993-4; THRMB-01; THRMB-02; USP 788; AAMI TIR42; ISO 10555-1; ISO 25539-2; PART-02; ASTM F2743; ISO 25539-3; PART-03; PART-04; ISO 10555-1; JIS T 3268; POWR-864; ANSI/AAMI VP20; ISO 7198; ISO 10555-4; ISO 20697; ISO 25539-1; JIS T 3247; ISO 11070; PRES-191; ASTM F2081; PRES-195
ASTM F2082; BFR-100 Lab Developed Method; ASTM G31; ISO 9626; ISO 16428; ISO 11070; ISO 10555-1; ISO 20695; ISO 20696; ISO 20697; ISO 25539-1; ISO 25539-2; ISO 25539-3; JIS T 3214; JIS T 3215; JIS T 3216; JIS T 3260; ACOR-716 Lab Developed Method; ASTM F2129; ASTM F3044; ASTM G5; ASTM G59; ASTM G71
ELEC-100; IEC 60601-2-21; ANSI/AAMI 60601-2-21; IEC 60601-1; ANSI/AAMI ES60601-1; BSEP-202; IEC 60601-2-182; BSEP-218; IEC 60601-1-2
ANSI/AAMI/IEC 60601-1-2; IEC 61000-4-2; ESD-001; IEC 60601-1-2; ANSI/AAMI/IEC 60601-1-2; IEC 61000-4-4; IEC 61000-4-5; FAST-002; ISO 8600-1; ISO 8600-3; ISO 8600-6; OPT-248; IEC 60601-1 Edition 3.2 2020-08 CONSOLIDATED VERSION; ANSI/AAMI ES60601-1:2005/(R)2012 & A1:2012, C1:2009/(R)2012 & A2:2010/(R)2012 (Cons. Text) [Incl. AMD2:2021]; ANSI AAMI IEC 60601-1-2:2014 [Including AMD 1:2021]; IEC 60601-2-18: Edition 3.0 2009-08; ANSI AAMI/IEC 60601-2-2 Edition 6.0 2017-03
Read from the A2LA scope documents we downloaded on 2026-10-27. Register refreshed 2026-11-20.
Scope as published by A2LA
10 lines
ISO/IEC 17025
Active2194.01
The scope document we hold says it is valid until 2028-06-30.
ISO/IEC 17025
Active2194.02
The scope document we hold says it is valid until 2028-06-30.
ISO/IEC 17025
Active2194.03
Location
Labs with overlapping accredited scope in United States
- Technical Maintenance, Inc. - ROCKFORDRockford, IL · ~268 kmA2LAShares 1 accredited test methodIEC 61000-4-2
- Trescal, Inc. - Cleveland, OHOakwood Village, OH · ~271 kmA2LAShares 1 accredited test methodIEC 61000-4-2
- Technical Maintenance, Inc. - HILLIARDHilliard, OH · ~323 kmA2LAShares 1 accredited test methodIEC 61000-4-2
- NSF InternationalAnn Arbor, MI · ~335 kmA2LAShares 1 accredited test methodIEC 61000-4-2
- Analysis and Measurement Services Corporation (AMS)Knoxville, TN · ~561 kmA2LAShares 1 accredited test methodIEC 61000-4-2
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.