ELICROM PERÚ SAC
Av Faustino Sanchez Carrion 615, Off. 804, Lima, 15076, Peru, Lima, Peru
Visit website- Scope lines
- 23
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 23 scope lines.
A2LA certificate 4286.04 · 23 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4286.04) 11/18/2025 Page 1 of 23
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
ELICROM PERU S.A.C.
Av. Faustino Sánchez Carrión N° 615, Off # 804
Lima, Perú 15076
José Aparcana Phone: 051 017669297
CALIBRATION
Valid To: August 31, 2027 Certificate Number: 4286.04
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations
1, 6:
I. Acoustics
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
Sound Level Meters &
Dosimeters –
Acoustic Calibration
(94, 104, 114) dB
re: 20 μPa
Electric Calibration
(30 to 150) dB
(31.5 to 125) Hz
(250 to 500) Hz
1000 Hz
(2000 to 4000) Hz
8000 Hz
(12 500 to 16 000) Hz
(20 to 20 000) Hz
0.20 dB
0.15 dB
0.13 dB
0.20 dB
0.28 dB
0.51 dB
0.078 dB
Multifunction acoustic
calibrator
Multiproduct
calibrator
Acoustic Calibrator
re: 20 μPa
94 dB
114 dB
1 kHz at 94 dB
1 kHz at 114 dB
0.15 dB
0.15 dB
0.24 Hz
0.24 Hz
Multifunction acoustic
calibrator
Sound level meter
Digital multimeter | ||
| 2 | - | Conductivity standard solution; pH buffer solution; deoxygenated solution; oxygen saturated water; Stabilized Formazin turbidity standardShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4286.04) 11/26/2025 Page 2 of 23
II. Chemical
Parameter/Equipment
Range
CMC2, 5, 9 (±)
Comments
Conductivity Meters3
1 µS/cm
5 µS/cm
10 µS/cm
100 µS/cm
1000 µS/cm
1413 µS/cm
10 000 µS/cm
12 880 µS/cm
100 000 µS/cm
0.62 µS/cm
0.62 µS/cm
0.62 µS/cm
2.1 µS/cm
4.6 µS/cm
4.6 µS/cm
40 µS/cm
50 µS/cm
360 µS/cm
Conductivity standard
solution
TDS Meters3
0.66 mg/L
3.3 mg/L
6.6 mg/L
66 mg/L
660 mgL
941 mg/L
6600 mg/L
66 000 mg/L
0.41 mg/L
0.41 mg/L
0.41 mg/L
1.4 mg/L
3.0 mg/L
3.0 mg/L
26 mg/L
240 mg/L
Conductivity standard
solution
pH Meters3
2 pH Unit
4 pH Unit
7 pH Unit
10 pH Unit
12 pH Unit
0.020 pH Unit
0.011 pH Unit
0.011 pH Unit
0.011 pH Unit
0.030 pH Unit
pH buffer solution
Dissolved Oxygen3 –
Measuring Devices
0 mg/L
(5.47 to 14.62) mg/L
0.0083 mg/L
0.072 mg/L
Comparison with
deoxygenated solution
Comparison to oxygen
saturated water at
controlled temperature
using Benson-Krausen
equation.Where (c) is
concentration in mg/l.
Turbidity Meters3
0.50 NTU
10 NTU
20 NTU
100 NTU
500 NTU
1000 NTU
4000 NTU
1.0 %
1.0 %
3.0 %
1.0 %
0.40 %
1.5 %
0.80 %
Stabilized Formazin
turbidity standard | See scope document |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4286.04) 11/26/2025 Page 3 of 23
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Breath Analyzer
0.2420 g/L
0.6050 g/L
1.2100 g/L
0.0030 g/L
0.0073 g/L
0.015 g/L
Standard reference
solutions
Refractometers3 –
Brix
Refractive Index
(2.50 to 40.00) °Brix
70.00 °Brix
97.00 °Brix
1.336 59 to 1.399 86
1.466 66 to 1.557 68
0.019 °Brix
0.031 °Brix
0.027 °Brix
0.000 027 RI
0.000 074 RI
Standard solutions
RI = refractive index
III. Dimensional
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Calipers3 –
Digital
Analog (Vernier)
Analog (Dial)
Up to 450 mm
Up to 450 mm
Up to 200 mm
(200 to 300) mm
8.2 µm
16 µm
8.2 µm
16 µm
Gauge blocks
Depth Gages3 –
Digital
Analog (Vernier)
Analog (Dial)
Up to 450 mm
Up to 450 mm
Up to 450 mm
5.8 µm
12 µm
5.8 µm
Gauge blocks
Height Gauges3 –
Digital
Analog (Vernier)
Analog (Dial)
Up to 450 mm
Up to 450 mm
Up to 450 mm
5.8 µm
12 µm
5.8 µm
Gauge blocks | ||
| 4 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4286.04) 11/26/2025 Page 4 of 23
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Outside, Inside & Depth
Micrometers, Indicators,
Thickness Gauges3 –
Digital
Analog
Up to 25 mm
(25 to 50) mm
(50 to 75) mm
(75 to 100) mm
(100 to 125) mm
(125 to 150) mm
(150 to 175) mm
(175 to 200) mm
(200 to 225) mm
(225 to 250) mm
(250 to 275) mm
(275 to 300) mm
(300 to 325) mm
(325 to 350) mm
(350 to 375) mm
(375 to 400) mm
(400 to 425) mm
(425 to 450) mm
Up to 25 mm
(25 to 50) mm
(50 to 75) mm
(75 to 100) mm
(100 to 125) mm
(125 to 150) mm
(150 to 175) mm
(175 to 200) mm
(200 to 225) mm
(225 to 250) mm
(250 to 275) mm
(275 to 300) mm
(300 to 325) mm
(325 to 350) mm
(350 to 375) mm
(375 to 400) mm
(400 to 425) mm
(425 to 450) mm
0.58 µm
0.60 µm
0.60 µm
0.61 µm
0.61 µm
0.62 µm
0.67 µm
0.70 µm
0.70 µm
0.70 µm
0.72 µm
0.76 µm
0.76 µm
0.80 µm
0.83 µm
0.83 µm
0.87 µm
0.87 µm
1.2 µm
1.2 µm
1.2 µm
1.2 µm
1.7 µm
1.7 µm
1.7 µm
1.7 µm
1.7 µm
1.7 µm
1.7 µm
1.7 µm
1.7 µm
1.7 µm
1.8 µm
1.8 µm
1.8 µm
1.8 µm
Gauge blocks
Optical & Stereo
Microscopes, with Reticle
3
Up to 400X
Magnification
4.7 µm
Stage micrometer | to 400 X Magnification |
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4286.04) 11/26/2025 Page 5 of 23
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Sieves3
Up to 710 µm
(710 to 800) mm
3.3 µm
6.5 µm
Magnifying glass
(loupe)
Ultrasonic Thickness
Gauges3
Up to 100 mm
0.58 µm
Gauge blocks
IV. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 5, 7 (±)
Comments
DC Voltage – Generate
Up to 200 mV
(0.22 to 2) V
(2.2 to 20) V
(20 to 200) V
(200 to 1000) V
4.4 µV + 33 µV/V
9.7 µV + 35 µV/V
4.6 µV + 31 µV/V
0.97 mV + 38 µV/V
8.7 mV + 34 µV/V
Multiproduct calibrator
DC Current – Generate
Up to 200 µA
(0.21 to 2) mA
(2 to 20) mA
(20 to 200) mA
(0.2 to 2) A
(2 to 20) A
35 nA + 0.12 nA/µA
45 nA + 0.10 µA/mA
0.34 µA + 63 nA/mA
3.2 µA + 0.11 µA/mA
3.6 µA + 0.36 mA/A
0.10 mA + 0.80 mA/A
Multiproduct calibrator
DC Current – Clamp On
Meters
Up to 10 mA
(> 10 to 100) mA
(> 100 to 1000) mA
(> 1 to 10) A
(> 10 to 100) A
(> 100 to 200) A
(> 200 to 1000) A
0.0082 mA
0.082 mA
0.000 82 A
0.0082 A
78 mA + 4.7 mA/A
69 mA + 4.9 mA/A
0.10 A + 3.2 mA/A
Multiproduct calibrator
& multifunction
workstation
Insulation Resistance –
Fixed Points
Up to 1 MΩ
5 MΩ
10 MΩ
50 MΩ
100 MΩ
500 MΩ
1 GΩ
5 GΩ
10 GΩ
15 GΩ
20 GΩ
0.0024 MΩ
0.013 MΩ
0.12 MΩ
0.58 MΩ
1.2 MΩ
5.8 MΩ
0.012 GΩ
0.061 GΩ
0.11 GΩ
0.18 GΩ
0.24 GΩ
Multiproduct calibrator
& Standard resistance
box | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4286.04) 11/26/2025 Page 6 of 23
Parameter/Equipment
Range
CMC2, 5, 7 (±)
Comments
Resistance – Generate
4 wire
2 wire
1 Ω
10 Ω
100 Ω
1 kΩ
10 kΩ
100 kΩ
1 MΩ
10 MΩ
100 MΩ
1000 MΩ
5.9 mΩ
6.9 mΩ
12 mΩ
93 mΩ
0.93 Ω
9.3 Ω
0.17 kΩ
4.6 kΩ
0.59 MΩ
12 MΩ
Multiproduct calibrator
Parameter/Range
Frequency
CMC2, 5, 7 (±)
Comments
AC Voltage – Generate
(0 to 200) mV
(0 to 200) mV
(0.2 to 2) V
(0.2 to 2) V
(2 to 20) V
(2 to 20) V
(20 to 200) V
(20 to 200) V
(200 to 1000) V
(200 to 1000) V
56 Hz
1 kHz
56 Hz
1 kHz
56 Hz
1 kHz
56 Hz
1 kHz
56 Hz
1 kHz
25 µV + 0.58 mV/V
74 µV + 1.0 mV/V
0.083 mV + 0.61 mV/V
0.15 mV + 1.1 mV/V
0.83 mV + 0.56 mV/V
1.4 mV + 0.88 mV/V
6.2 mV + 0.62 mV/V
42 mV + 1.1 mV/V
72 mV + 0.63 mV/V
0.51 V + 1.5 mV/V
Multiproduct calibrator
AC Current – Generate
(0.2 to 2) mA
(0.2 to 2) mA
(2 to 20) mA
(2 to 20) mA
(20 to 200) mA
(20 to 200) mA
(0.21 to 2) A
(0.21 to 2) A
(2 to 20) A
(2 to 20) A
40 Hz
56 Hz
40 Hz
56 Hz
40 Hz
56 Hz
40 Hz
56 Hz
40 Hz
56 Hz
0.62 µA + 2.4 µA/mA
0.46 µA + 0.92 µA/mA
5.1 µA + 2.4 µA/mA
47 µA + 0.72 µA/mA
51 µA + 2.4 µA/mA
42 µA + 0.94 µA/mA
0.50 mA + 2.5 mA/A
0.41 mA + 1.3 mA/A
5.4 mA + 2.8 mA/A
0.89 mA + 1.9 mA/A
Multiproduct calibrator | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4286.04) 11/26/2025 Page 7 of 23
Parameter/Equipment
Range
CMC2, 4, 8 (±)
Comments
AC Current – Clamp On
Meters (All Types)
56 Hz
Up to 100 A
(> 100 to 300) A
(> 300 to 500) A
(> 500 to 700) A
(> 700 to 1000) A
9.1 µA + 0.62 µA/mA
91 µA + 0.62 µA/mA
0.84 mA + 1.1 mA/A
6.5 mA + 1.4 mA/A
72 mA + 4.9 mA/A
Multiproduct calibrator
& multifunction
workstation
DC Voltage – Measure
(0 to 100) mV
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
1.4 µV + 63 µV/V
3.3 µV + 39 µV/V
8.1 µV + 35 µV/V
-37 µV + 43 µV/V
0.64 mV + 42 µV/V
Precision multimeter
DC Current – Measure
(0 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(1 to 10) A
(10 to 30) A
0.45 nA + 0.45 nA/µA
29 nA + 0.11 µA/mA
50 nA + 0.091 µA/mA
0.29 µA + 0.14 µA/mA
7.4 µA + 0.39 mA/A
0.46 mA + 0.64 mA/A
4.5 mA + 1.0 mA/A
Precision multimeter
Parameter/Range
Frequency
CMC2, 4, 8 (±)
Comments
AC Current – Measure
(0.1 to 1) mA
(0.1 to 1) mA
(1 to 10) mA
(1 to 10) mA
(10 to 100) mA
(10 to 100) mA
(0.1 to 1) A
(0.1 to 1) A
(1 to 10) A
(1 to 10) A
(10 to 30) A
(10 to 30) A
40 Hz
56 Hz
40 Hz
56 Hz
40 Hz
56 Hz
40 Hz
56 Hz
40 Hz
56 Hz
40 Hz
56 Hz
0.27 µA + 2.7 µA/mA
0.30 µA + 1.1 µA/mA
0.56 µA + 2.9 µA/mA
1.0 µA + 1.3 µA/mA
5.6 µA + 2.9 µA/mA
10 µA + 1.3 µA/mA
0.089 mA + 3.0 mA/A
0.10 mA + 1.8 mA/A
3.6 mA + 3.1 mA/A
4.0 mA + 2.2 mA/A
12 mA + 2.8 mA/A
12 mA + 2.2 mA/A
Precision multimeter | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4286.04) 11/26/2025 Page 8 of 23
Parameter/Range
Frequency
CMC2, 4, 8 (±)
Comments
AC Voltage – Measure
(0 to 200) mV
(0 to 200) mV
(0.2 to 2) V
(0.2 to 2) V
(2 to 20) V
(2 to 20) V
(20 to 200) V
(20 to 200) V
(200 to 1000) V
(200 to 1000) V
56 Hz
1 kHz
56 Hz
1 kHz
56 Hz
1 kHz
56 Hz
1 kHz
56 Hz
1 kHz
65 µV + 0.19 mV/V
41 µV + 1.1 mV/V
40 µV + 0.65 mV/V
83 µV + 1.1 mV/V
2.3 mV + 0.57 mV/V
0.79 mV + 0.94 mV/V
10 mV + 0.63 mV/V
6.6 mV + 1.6 mV/V
-0.79 V + 4.3 mV/V
-0.50 V + 4.6 mV/V
Precision multimeter
Parameter/Range
Range
CMC2, 4, 8 (±)
Comments
Resistance (2 Wire) –
Measure
100 kΩ
1 MΩ
10 MΩ
0.0096 kΩ
0.16 kΩ
4.5 kΩ
Precision multimeter
Resistance (4 Wire) –
Measure
1 Ω
10 Ω
100 Ω
1 kΩ
10 kΩ
100 kΩ
5.9 mΩ
6.9 mΩ
12 mΩ
0.094 Ω
0.95 Ω
9.8 Ω
Precision multimeter
V. Fluid Quantities
Parameter/Equipment
Range CMC2, 5 (±) Comments
Volume – Laboratory
Glassware
One-mark Volumetric
Flasks
Graduated Pipettes
Up to 10 mL
(> 10 to 25) mL
(> 25 to 50) mL
(> 50 to 100) mL
(> 100 to 250) mL
(> 250 to 500) mL
(> 500 to 1000) mL
(> 1000 to 2000) mL
(> 2000 to 5000) mL
Up to 50 mL
0.0022 mL
0.0037 mL
0.0056 mL
0.0080 mL
0.012 mL
0.020 mL
0.034 mL
0.057 mL
0.13 mL
4.6 nL + 0.022 µL/mL
Gravimetric method | ||
| 9 | - | Laboratory GlasswareShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4286.04) 11/26/2025 Page 9 of 23
Parameter/Equipment
Range CMC2, 5, 9 (±) Comments
Volume – Laboratory
Glassware (cont)
Graduated Measuring
Cylinders
Burettes
Pyknometers:
Type 3 (Gay-Lussac),
Type 4 (Reischauer),
Type 5 (Hubbard),
Type 6 (With
Thermometer Coupled)
Centrifuge Tube
(6 in, 8 in)
Imhoff Cone
Beaker
Water Trap
Standard Test Measures
(Seraphin Test Measures)
Up to 5 mL
(> 5 to 10) mL
(> 10 to 25) mL
(> 25 to 50) mL
(> 50 to 100) mL
(> 100 to 250) mL
(> 250 to 500) mL
(> 500 to 1000) mL
(> 1000 to 2000) mL
Up to 400 mL
Up to 1 mL
(> 1 to 2) mL
(> 2 to 5) mL
(> 5 to 10) mL
(> 10 to 25) mL
(> 25 to 50) mL
(> 50 to 100) mL
Up to 25 mL
(> 25 to 50) mL
(> 50 to 100) mL
Up to 1000 mL
Up to 5 mL
(> 5 to 10) mL
(> 10 to 50) mL
(> 50 to 100) mL
(> 100 to 150) mL
(> 150 to 200) mL
(> 200 to 250) mL
(> 250 to 500) mL
(> 500 to 1000) mL
Up to 1 mL
(> 1 to 2) mL
(> 2 to 5) mL
(> 5 to 10) mL
(> 10 to 25) mL
Up to 5 gal
0.029 µL + 0.018 µL/mL
0.065 µL + 0.017 µL/mL
0.13 µL + 0.018 µL/mL
0.056 µL + 0.021 µL/mL
0.25 µL + 0.019 µL/mL
1.2 µL + 0.017 µL/mL
1.4 µL + 0.019 µL/mL
8.0 µL + 0.016 µL/mL
-0.5 µL + 0.025 µL/mL
13 nl + 0.022 µL/mL
0.027 µL
0.046 µL
0.11 µL
0.22 µL
0.55 µL
1.1 µL
2.2 µL
36 nl + 0.026 µL/mL
-0.94 µL + 0.065 µL/mL
-5.4 µL + 0.15 µL/mL
0.35 µL + 0.14 µL/mL
0.000 42 mL
0.000 46 mL
0.0023 mL
0.0046 mL
0.0061 mL
0.0093 mL
0.012 mL
0.042 mL
0.047 mL
22 nl + 0.0095 µL/mL
13 nl + 0.018 µL/mL
19 nl + 0.020 µL/mL
31 nl + 0.018 µL/mL
42 nl + 0.020 µL/mL
0.05 % IV
Gravimetric
method | to 5 gal |
| 10 | - | Laboratory GlasswareShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4286.04) 11/26/2025 Page 10 of 23
Parameter/Equipment
Range CMC2, 5 (±) Comments
Volume – Laboratory
Glassware (cont)
Single Volume Pipettes
Up to 0.5 mL
(> 0.5 to 1.5) mL
(> 1.5 to 2.5) mL
(> 2.5 to 3.5) mL
(> 3.5 to 4.5) mL
(> 4.5 to 5) mL
(> 5 to 6) mL
(> 6 to 7) mL
(> 7 to 14) mL
(> 14 to 20) mL
(> 20 to 30) mL
(> 30 to 35) mL
(> 35 to 40) mL
(> 40 to 50) mL
(> 50 to 60) mL
(> 60 to 70) mL
(> 70 to 80) mL
(> 80 to 90) mL
(> 90 to 100) mL
(> 100 to 200) mL
(> 200 to 250) mL
0.000 29 mL
0.000 56 mL
0.000 92 mL
0.000 93 mL
0.000 94 mL
0.000 92 mL
0.000 94 mL
0.000 96 mL
0.0012 mL
0.0014 mL
0.0015 mL
0.0016 mL
0.0019 mL
0.0020 mL
0.0021 mL
0.0023 mL
0.0031 mL
0.0033 mL
0.0034 mL
0.0056 mL
0.0065 mL
Gravimetric method
Piston Operated Volumetric
Apparatus3–
Piston Pipettes
Piston Burettes
Dispensers
Up to 10 μL
(> 10 to 100) μL
(> 100 to 1000) μL
(> 1000 to 10 000) μL
Up to 1 mL
(> 1 to 2) mL
(> 2 to 5) mL
(> 5 to 10) mL
(> 10 to 25) mL
(> 25 to 50) mL
Up to 0.5 mL
(> 0.5 to 5) mL
(> 5 to 50) mL
(> 50 to 100) mL
1.0 nL + 0.057 nL/mL
0.63 nL + 0.13 nL/mL
3.3 nL + 0.14 nL/mL
-4.0 nL + 0.14 nL/mL
0.000 14 mL
0.000 28 mL
0.000 70 mL
0.0014 mL
0.0035 mL
0.0071 mL
15 nL + 0.12 µL/mL
3.7nL + 0.14 µL/mL
5.7 nL + 0.14 µL/mL
0.14 µL/mL
Gravimetric method | to 0.5 mL |
| 11 | - | Viscosity standard solutionShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4286.04) 11/26/2025 Page 11 of 23
Parameter/Equipment
Range CMC2, 5, 9 (±) Comments
Viscometer3 –
Rotational Devices
Rotational Devices
Cinematic Devices
(5.809 to 636.5) cP
(> 636.5 to 6024) cP
(> 6024 to 197 200) cP
(> 197 200 to 843 100) cP
(1.150 to 10) mm²/s
(> 10 to 100) mm²/s
(> 100 to 1000) mm²/s
(> 1000 to 10 000) mm²/s
(> 10 000 to 74 230) mm²/s
0.29 %
0.38 %
0.44 %
0.44 %
0.16 %
0.22 %
0.29 %
0.38 %
0.44 %
Viscosity standard
solution
Flow Rate – Liquids3
Mass
Volumetric
Mass
Volumetric
Mass
Volumetric
Up to 100 kg/min
Up to 100 l/min
Up to 500 kg/min
Up to 500 l/min
Up to 500 kg/min
Up to 500 l/min
0.026 %
0.031 %
0.11 %
0.11 %
0.34 %
0.34 %
Gravimetric flow rig
Direct comparison
with Coriolis
reference standard
Direct comparison
with standard flow
rig or standard
ultrasonic flow meter
Flow Rate – Gases
Volumetric
(0.015 to 0.5) l/min
(> 0.5 to 30) l/min
(0.48R + 0.0070) %
(0.033R + 0.0015) %
Gas flow primary
standards
Viscosity Cups3 –
Ford Cup # 1
Ford Cup # 2
Ford Cup # 3
Ford Cup # 4
Ford Cup # 5
(10 to 35) mm²/s
(20 to 120) mm²/s
(49 to 220) mm²/s
(70 to 370) mm²/s
(200 to 1200) mm²/s
0.16 %
0.16 %
0.16 %
0.16 %
0.16 %
Viscosity standard
solution | See scope document |
| 12 | - | Viscosity standard solution; Gas DetectionShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4286.04) 11/26/2025 Page 12 of 23
Parameter/Equipment
Range CMC2, 5, 9 (±) Comments
Viscosity Cups3 – (cont)
Zahn Cup # 1
Zahn Cup # 2
Zahn Cup # 3
Zahn Cup # 4
Zahn Cup # 5
Shell Cup # 1
Shell Cup # 2
Shell Cup # 2 ½
Shell Cup # 3
Shell Cup # 3 ½
Shell Cup # 4
Shell Cup # 5
Shell Cup # 6
Stein Hall Cup
(5 to 78) mm²/s
(20 to 250) mm²/s
(100 to 800) mm²/s
(200 to 1200) mm²/s
(400 to 1800) mm²/s
(2 to 20) mm²/s
(10 to 50) mm²/s
(20 to 80) mm²/s
(30 to 120) mm²/s
(40 to 170) mm²/s
(70 to 270) mm²/s
(125 to 520) mm²/s
(320 to 1300) mm²/s
15 s
0.26 %
0.29 %
0.29 %
0.32 %
0.38 %
0.26 %
0.26 %
0.26 %
0.29 %
0.32 %
0.29 %
0.32 %
0.38 %
0.040 %
Viscosity standard
solution
Gas Detection
Equipment -
H2S
O2
CO
Methane (% LEL)
25 parts in 10
6 H2S
18 % O2
3 parts in 106 CO
40 parts in 106 CO
100 parts in 106 CO
500 parts in 106 CO
1000 parts in 106 CO
50 % LEL
0.78 parts in 10
6 H2S
0.36 % O2
0.58 parts in 106 CO
0.70 parts in 106 CO
2.1 parts in 106 CO
2.1 parts in 106 CO
9.8 parts in 106 CO
1.2 % LEL
Standard gas
LEL = lower
explosive limit | See scope document |
| 13 | - | Standard gasShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4286.04) 11/26/2025 Page 13 of 23
Parameter/Equipment
Range CMC2, 5 (±) Comments
Gas Detection
Equipment – (cont)
SO2
NO
NH
3
3 parts in 10
6 SO2
40 parts in 106 SO2
500 parts in 106 SO2
1000 parts in 106 SO2
3 parts in 10
6 NO
40 parts in 106 NO
500 parts in 106 NO
1000 parts in 106 NO
25 parts in 10
6 NH3
50 parts in 106 NH3
100 parts in 106 NH3
0.58 parts in 10
6 SO2
0.70 parts in 106 SO2
4.0 parts in 106 SO2
8.0 parts in 106 SO2
0.58 parts in 10
6 NO
0.73 parts in 106 NO
4.1 parts in 106 NO
7.1 parts in 106 NO
1.4 parts in 10
6 NH3
2.5 parts in 106 NH3
2.0 parts in 106 NH3
Standard gas
Hydrometry: Specific
Gravity (Relative Density)
Hydrometers & Equivalent
Values in Other
Hydrometer Scales:
Density (g/mL, g/cm³,
kg/m³)
Baumé Light
Hydrometers
Baumé Heavy
Hydrometers
API Hydrometers &
Thermo-hydrometers
(API Scale for Petroleum
Products)
Lactometers (Quevenne
Scale)
(0.500 to 0.650) SG
(0.650 to 0.950) SG
(0.950 to 1.150) SG
(1.150 to 1.300) SG
(1.300 to 1.450) SG
(1.450 to 1.500) SG
(1.500 to 1.650) SG
(1.650 to 1.750) SG
(1.750 to 1.800) SG
(1.800 to 1.900) SG
(1.900 to 1.950) SG
(1.950 to 2.000) SG
(10.0 a 70.0) °Bé Lt
(0.0 a 70.0) °Bé Hy
(-1.0 a 101.0) °API
(15 to 40) °Q
0.000 12 SG
0.000 058 SG
0.000 059 SG
0.000 059 SG
0.000 059 SG
0.000 059 SG
0.000 067 SG
0.000 068 SG
0.000 069 SG
0.000 070 SG
0.000 072 SG
0.000 072 SG
0.012 °Bé Lt
0.012 °Bé Hy
0.012 °API
0.060 °Q
Cuckow method | See scope document |
| 14 | OIML; ASTM | - | See scope document |
| 15 | ASTM Classes 3, 4, 5, 6 & 7 | - | See scope document |
| 16 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4286.04) 11/26/2025 Page 16 of 23
Parameter/Equipment
Range
CMC2, 5, 6,9 (±)
Comments
Scales & Balances3
Up to 200 mg
(>0,2 to 6) g
(> 6 to 30) g
(> 30 to 110) g
(> 110 to 220) g
(> 220 to 350) g
(> 350 to 700) g
(> 700 to 1200) g
(> 1200 to 2500) g
(> 2500 to 4300) g
(> 4300 to 6200) g
(> 6.2 to 30) kg
(> 30 to 100) kg
(> 100 to 300) kg
(> 300 to 600) kg
(> 600 to 1500) kg
(> 1500 to 2000) kg
1.6 µg
1.1 µg + 0.71 µg/g
0.74 µg + 0.34 µg/g
0.62 µg + 0.14 µg/g
75 µg + 0.088 µg/g
0.82 mg
0.83 mg
0.77 mg + 0.080 µg/g
0.069 mg + 0.20 µg/g
8.2 mg
8.3 mg
0.082 g
0.84 g
4.1 g
4.2 g
3.8 g + 0.66 mg/kg
0.44 kg
Standard weights
Torque Wrenches &
Drivers
Up to 813 N·m
1.8 %
Torque transducers
Pressure3 –
Pneumatic (Including
Pressure Modules &
Pressure Switch)3
Barometric
(-15 to 0) psi
Up to 300 psi
(> 300 to 1000) psi
(> 1000 to 10 000) psi
(600 to < 650) mbar
(650 to < 800) mbar
(800 to < 950) mbar
(950 to < 1000) mbar
(1000 to < 1030) mbar
0.0058 psi
0.0056 psi + 0.000 012R
0.14 psi
1.2 psi
0.26 mbar
0.28 mbar
0.29 mbar
0.31 mbar
0.34 mbar
Digital pressure
calibrator
Vacuum chamber &
standard barometer | to 2000 kg |
| 17 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4286.04) 11/26/2025 Page 17 of 23
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Centrifugues3 –
Rotational Speed
(60 to 900) rpm
(> 900 to 3000) rpm
(> 3000 to 12 000) rpm
(> 12 000 to 18 000) rpm
(> 18 000 to 20 000) rpm
(> 20 000 to 30 000) rpm
(> 30 000 to 40 000) rpm
(> 40 000 to 50 000) rpm
(> 50 000 to 60 000) rpm
1.2 rpm
1.3 rpm
1.7 rpm
2.1 rpm
2.2 rpm
3.0 rpm
3.7 rpm
4.5 rpm
5.3 rpm
Digital tachometer
Air Velocity –
Anemometers & Air
Velocity Meters
Balometers- Air
Velocity
Balometers- Flow Rate
0.30 m/s
(> 0.30 to 5) m/s
(> 5 to 10) m/s
(> 10 to 20) m/s
(> 20 to 30) m/s
(0.50 to 1) m/s
(> 1 to 8) m/s
(> 8 to 12) m/s
(25 to 100) ft³/min
(> 100 to 500) ft³/min
(> 500 to 1000) ft³/min
(> 1000 to 1580) ft³/min
0.030 m/s
0.088 m/s
0.090 m/s
0.13 m/s
0.21 m/s
0.030 m/s
0.088 m/s
0.090 m/s
1.6 ft³/min
4.7 ft³/min
6.9 ft³/min
11 ft³/min
Wind tunnel &
standard
anemometer
VII. Optical Quantities
Parameter/Equipment
Range
CMC2, 4, 9 (±)
Comments
Colorimeters3 - Total
Residual Chlorine
&Residual Free Chlorine
0.10 mg/L Cl₂
0.50 mg/L Cl₂
1.0 mg/L Cl₂
1.5 mg/L Cl₂
2.0 mg/L Cl₂
0.0058 mg/L Cl₂
0.0061 mg/L Cl₂
0.0065 mg/L Cl₂
0.0091 mg/L Cl₂
0.020 mg/L Cl₂
Total residual
chlorine standards
Light Meters
(30 to 10 000) lux
(> 10 000 to 20 000) lux
1.0 %
1.1 %
Reference standard
lamp | ||
| 18 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4286.04) 11/26/2025 Page 18 of 23
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Spectrophotometers3 –
Absorbance
λ: (235 to 350) nm
λ: (440 to 750) nm
Transmittance
λ: (235 to 350) nm
λ: (440 to 750) nm
Wavelength
SBW: (0.5, 1.0) nm
SBW: (1.5, 2.0) nm
SBW: (3.0, 4.0) nm
SBW: (0.5, 1.0, 1.5,
2.0, 3.0, 4.0) nm
(0.1 to 1.5) A
(0.3 to 0.6) A
(0.6 to 1.5) A
(5.5 to 80.5) %
(2.5 to 26.0) %
(26.0 to 50.5) %
(240 to 638) nm
(240 to 638) nm
(240 to 638) nm
(430 to 880) nm
0.0010 A
0.000 91 A
0.0010 A
0.012 % of Transmittance
0.022 % of Transmittance
0.041 % of Transmittance
0.070 nm
0.080 nm
0.12 nm
0.11 nm
Potassium dichromate
quartz cells
Neutral density glass
filters
Potassium dichromate
quartz cells
Neutral density glass
filters
Holmium glass filter
Didymium glass filter
VIII. Thermodynamics
Parameter/Equipment
Range CMC2, 5 (±) Comments
Liquid & Dry Baths
(Dry Wells) 3
(-80 to -40) °C
(-40 to -25) °C
(-25 to 0) °C
(0 to 140) °C
(141 to 299) °C
(300 to 499) °C
(500 to 599) °C
(600 to 799) °C
(800 to 999) °C
(1000 to 1100) °C
0.030 °C
0.028 °C
0.026 °C
0.027 °C
0.032 °C
0.073 °C
0.079 °C
0.66 °C
1.3 °C
1.3 °C
Reference RTD
thermometers,
thermistors,
thermocouples | ||
| 19 | - | Climatic Chambers (Including Ovens, Incubators, Stoves, Refrigerators, Freezers, Muffles, Thermo-reactors, Weather Cameras, Centrifuges); Autoclaves; Bi-metal ThermometersShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4286.04) 11/26/2025 Page 19 of 23
Parameter/Equipment
Range CMC2, 5, 9 (±) Comments
Climatic Chambers
(Including Ovens,
Incubators, Stoves,
Refrigerators, Freezers,
Muffles, Thermo-reactors,
Weather Cameras,
Centrifuges) 3
Humidity (% RH)
Temperature
(10 to 30) % RH
(> 30 to 50) % RH
(> 50 to 70) % RH
(> 70 to 90) % RH
(-80 to -50) °C
(-50 to -25) °C
(-25 to 0) °C
(0 to 50) °C
(50 to 100) °C
(100 to 150) °C
(150 to 200) °C
(200 to 400) °C
(400 to 600) °C
(600 to 1100) °C
0.73 % RH
0.86 % RH
0.81 % RH
0.98 % RH
0.064 °C
0.063 °C
0.063 °C
0.066 °C
0.066 °C
0.066 °C
0.067 °C
0.077 °C
0.29 °C
1.3 °C
Reference standard
thermometers,
thermistors,
thermocouples,
thermo-hygrometers
Autoclaves3 –
Temperature
Temperature deviation
in time & space
Stability
Uniformity
(100 to 180) °C
(100 to 180) °C
(100 to 180) °C
(100 to 180) °C
0.094 °C
0.082 °C
0.041 °C
0.084 °C
Temperature
dataloggers
Bi-metal Thermometers3
(-25 to 0) °C
(0 to 100) °C
(100 to 150) °C
(150 to 200) °C
(200 to 300) °C
(300 to 450) °C
0.17 °C
0.16 °C
0.24 °C
1.2 °C
1.3 °C
1.4 °C
Reference RTD
thermometers &
temperature blocks | See scope document |
| 20 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4286.04) 11/26/2025 Page 20 of 23
Parameter/Equipment
Range CMC2, 5 (±) Comments
Digital Thermometers3
(-25 to -5) °C
(-5 to 25) °C
(25 to 50) °C
(50 to 100) °C
(100 to 150) °C
(150 to 200) °C
(200 to 400) °C
(400 to 600) °C
(600 to 800) °C
(800 to 1100) °C
0.14 °C
0.087 °C
0.082 °C
0.11 °C
0.16 °C
0.91 °C
1.5 °C
2.2 °C
3.0 °C
4.6 °C
Reference RTD
thermometers &
temperature blocks
Partial Immersion
Liquid-In-Glass
Thermometers
(-20 to 0) °C
(0 to 25) °C
(25 to 50) °C
(50 to 70) °C
(70 to 90) °C
(90 to 110) °C
(110 to 130) °C
(130 to 150) °C
(150 to 200) °C
(200 to 250) °C
(250 to 300) °C
0.086 °C
0.086 °C
0.086 °C
0.086 °C
0.086 °C
0.086 °C
0.10 °C
0.11 °C
0.16 °C
0.19 °C
0.21 °C
Reference RTD
thermometers &
temperature blocks
Total Immersion Liquid-
In-Glass Thermometers
(-20 to -10) °C
(> -10 to 0) °C
(> 0 to 50) °C
(> 50 to 100) °C
(> 100 to 140) °C
(> 140 to 150) °C
(> 150 to 200) °C
(> 200 to 250) °C
(> 250 to 300) °C
(> 300 to 350) °C
(> 350 to 400) °C
0.091 °C
0.077 °C
0.081 °C
0.092 °C
0.10 °C
0.10 °C
0.24 °C
0.43 °C
0.43 °C
0.43 °C
0.50 °C
Reference standard
thermometers &
temperature blocks | ||
| 21 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4286.04) 11/26/2025 Page 21 of 23
Parameter/Equipment
Range CMC2, 5 (±) Comments
Thermocouples –
Type B
Type E
Type J
Type K
Type R
Type S
Type T
600 °C
(> 600 to 800) °C
(> 800 to 1100) °C
(-80 to 100) °C
(> 100 to 300) °C
(> 300 to 800) °C
(> 800 to 1000) °C
(-80 to 100) °C
(> 100 to 300) °C
(> 300 to 800) °C
(> 800 to 1100) °C
(-80 to 100) °C
(> 100 to 300) °C
(> 300 to 800) °C
(> 800 to 1100) °C
(-20 to 100) °C
(> 100 to 300) °C
(> 300 to 600) °C
(> 600 to 800) °C
(> 800 to 1000) °C
(-20 to 100) °C
(> 100 to 300) °C
(> 300 to 600) °C
(> 600 to 800) °C
(> 800 to 1000) °C
(-80 to 100) °C
(> 100 to 300) °C
(> 300 to 400) °C
1.1 °C
1.2 °C
2.3 °C
0.11 °C
0.22 °C
1.1 °C
2.3 °C
0.14 °C
0.23 °C
1.1 °C
2.3 °C
0.15 °C
0.24 °C
1.1 °C
2.3 °C
0.81 °C
0.83 °C
1.3 °C
1.4 °C
2.4 °C
0.81 °C
0.83 °C
1.3 °C
1.4 °C
2.4 °C
0.15 °C
0.24 °C
1.0 °C
Temperature sources
monitored with
standard thermometer.
Thermocouple output
is read using process
calibrator.
Infrared Temperature –
Measuring Equipment
(≥-10 to 1) °C
(> 1 to 30) °C
(> 30 to 100) °C
(> 100 to 200) °C
(> 200 to 300) °C
(> 300 to 420) °C
(> 420 to 500) °C
0.69 °C
0.73 °C
0.77 °C
1.2 °C
2.1 °C
3.1 °C
4.0 °C
Fluke 4180 black body
Fluke 4181 black body
Ɛ = (0.9 to 1.0)
λ = (8 to 14) μm | ||
| 22 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4286.04) 11/26/2025 Page 22 of 23
Parameter/Equipment
Range CMC2, 4, 9 (±) Comments
Thermo-Hygrometers,
Dataloggers & Heat
Stress WBGT Meters*–
Humidity4
Temperature
(10 to 30) % RH
(30 to 50) % RH
(50 to 70) % RH
(70 to 90) % RH
(-20 to 0) °C
(0 to 20) °C
(20 to 30) °C
(30 to 40) °C
(40 to 60) °C
0.62 % RH
0.67 % RH
0.72 % RH
0.81 % RH
0.44 °C
0.19 °C
0.16 °C
0.13 °C
0.11 °C
Reference thermo-
hygrometer & climatic
chamber
*Including Wet bulb,
dry bulb, globe
temperature, & dew
point
Moisture Analyzers3
Up to 100 % h
0.058 % h
Convection oven &
balance
% h = percent
humidity of the
sample
IX. Time & Frequency
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Stopwatches & Timers3
Up to 2048 s
(> 2048 to 32 768) s
3.0 ms
1.9 ms + 0.17 ms/s
Reference stopwatch
Non-Contact
Tachometers
(60 to 300) rpm
(> 300 to 900) rpm
(> 900 to 3000) rpm
(> 3000 to 12 000) rpm
(> 12 000 to 18 000) rpm
(> 18 000 to 20 000) rpm
(> 20 000 to 30 000) rpm
(> 30 000 to 40 000) rpm
(> 40 000 to 50 000) rpm
(> 50 000 to 60 000) rpm
0.12 rpm
0.13 rpm
0.59 rpm
0.72 rpm
0.86 rpm
0.90 rpm
1.2 rpm
1.5 rpm
1.8 rpm
2.2 rpm
Multiproduct
calibrator &
multifunction
workstation
_____________________________________________ | ||
| 23 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4286.04) 11/26/2025 Page 23 of 23
1 This laboratory offers commercial calibration and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavi or of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 The contributions from the “best existing device” are not included in the CMC claim.
5 The CMC claim is smaller than that of the expanded uncertainty claim for INEN as listed in the BIPM
Key Comparison Database. A2LA has evaluated the laboratory’s CMC claim and has verified this
information to be correct and appropriate.
6 In the statement of CMC, R is the reading of the unit under test.
7 This scope meets A2LA’s P112 Flexible Scope Policy.
8 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
9 In statement of CMC, percentages are percentage of reading, unless otherwise indicated. | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Av Faustino Sanchez Carrion 615, Off. 804, Lima, 15076, Peru, Lima, PE
-12.04598, -77.03059
Open in MapsAccreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.