Ledford Gage
P.O. Box 100, 227 Industrial Drive, 67110, Mulvane, KS, United States
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at Ledford Gage?
Claim this profile to keep it accurate.
Register record
- A2LARefreshed
- 1560.01Active
Accredited standards
1Our reading of the A2LA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
ASTM E18Standard Test Methods for Rockwell Hardness of Metallic Materials
ASTM E18
Scope as published by A2LA
5 lines
ISO/IEC 17025
Active1560.01
The scope document we hold says it is valid until 2027-12-31.
Accredited scope, certificate 1560.01
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | dimensional | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 1 in |
| 2 | dimensional | - | - | to 6 in |
| 3 | mechanical | ASTM E18 | - | 5 to 1000 ozf·in; lbf·in; lbf·ft |
| 4 | - | (A2LA Cert. No. 1560.01) 10/09/2025 Page 4 of 4
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches,
T = torque measured value, and R is the numerical value of the resolution of the device under test in µin.
5 In the statement of CMC, percentages are to be read as percent of reading unless otherwise noted.
6 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 5 | - | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Johnson Gage and InspectionWichita, KS · ~25 kmA2LAShares 2 accredited test methodsANSI/NCSL Z540-1-1994ASTM E18
- Probata CorporationEdmond, OK · ~203 kmA2LAShares 2 accredited test methodsANSI/NCSL Z540-1-1994ASTM E18
- Trescal, Inc. - Dallas, TXIrving, TX · ~518 kmA2LAShares 2 accredited test methodsANSI/NCSL Z540-1-1994ASTM E18
- United StandardsBloomington, MN · ~881 kmA2LAShares 2 accredited test methodsANSI/NCSL Z540-1-1994ASTM E18
- Martin Calibration, Inc dba Great Lakes Calibration,Suite E Addison, IL · ~933 kmA2LAShares 2 accredited test methodsANSI/NCSL Z540-1-1994ASTM E18
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.