FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
Italy

ECS S.r.l.s.

Via Leonardo da Vinci, 10/B, 31048, San Biagio di Callalta, Italy

ACCREDIA|00990ISO/IEC 17025Register refreshed 2026-09-25
Certificates
1
Scope items
6
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at ECS S.r.l.s.?

Claim this profile to keep it accurate.

Register record

ACCREDIARefreshed
00990Active

Certificates and scope

1
ACCREDIA

ISO/IEC 17025

Active

00990

View scope

Accredited scope, certificate 00990

LineDisciplineMethodMatrixRange
1chemicalUNI CEI EN ISO/IEC 17025:2018; APAT CNR IRSA 4030 A1 Man 29 2003; APAT CNR IRSA 4100 B Man 29 2003; APAT CNR IRSA 4090 A1 Man 29 2003; Rapporti ISTISAN 2007/31 pag 164 Met ISS CAA036; APAT CNR IRSA 2110 Man 29 2003; Rapporti ISTISAN 2007/31 pag 90 Met ISS BJA021; UNI EN ISO 8467:1997; APAT CNR IRSA 4020 Man 29 2003; APAT CNR IRSA 3010 A + 3020 Man 29 2003Waste water0.1 to mg/L
2chemicalUNI CEI EN ISO/IEC 17025:2018; UNI EN ISO 17294-2:2023; APAT CNR IRSA 5060 Man 29 2003; APAT CNR IRSA 4050 Man 29 2003; APAT CNR IRSA 2030 Man 29 2003; APAT CNR IRSA 3010 A + 3020 Man 29 2003; APAT CNR IRSA 3150 C Man 29 2003; APAT CNR IRSA 5170 Man 29 2003; APAT CNR IRSA 4030 A2 Man 29 2003; APAT CNR IRSA 2060 Man 29 2003; ISO 15705:2002; APAT CNR IRSA 2090 B Man 29 2003; APAT CNR IRSA 4040 A1 Man 29 2003Drinking water-
3chemicalNIOSH 7301 2003; NIOSH 1501 2003; NIOSH 1300 1994; DM 06/09/1994 GU n 288 10/12/1994 All 2 met B; DM 06/09/1994 GU n 288 10/12/1994 All 2 Met A; DM 17/06/2002 GU n 220 19/09/2002 suppl.7 Met III.3; DM 17/06/2002 GU n 220 19/09/2002 suppl.7 Met III.4; UNI CEN/TS 13649:2015; UNI EN 13284-1:2017; UNI EN 14790:2017; UNI EN 14039:2005; UNI EN 14346:2007 Met A; UNI EN 13657:2004; APAT CNR IRSA 3020 Man 29 2003; UNI EN 12457Stationary source emissions-
4chemicalUNI CEI EN ISO/IEC 17025:2018; CNR IRSA 2 Q 64 Vol 2 1984/Notiziario IRSA 2 2008; UNI EN 12457-2:2004; UNI EN 1484:1999; APAT CNR IRSA 4020 Man 29 2003; APAT CNR IRSA 2060 Man 29 2003; ISO 15705:2002; UNI EN 15216:2021; DM 21/03/1973 GU n° 104 20/04/1973 All IV sez 1 DM 26/04/1993 GU n° 162 13/07/1993 All III DM 22/07/1998 GU 228 30/09/1998 DM 06/08/2015 GU n° 288 11/12/2015; DM 06/09/1994 GU n 288 10/12/1994 All 3; ISO 22262-1:2012; CNR IRSA 19 Q 64 Vol 3 1993; UNI EN 17503:2022; EPA 8315A 1996; DM 13/09/1999Soil-
5chemicalUNI CEI EN ISO/IEC 17025:2018; DM 13/09/1999 SO n 185 GU n 248 21/10/1999 Met XIII.2 DM 25/03/2002 GU n 84 10/04/2002; DM 13/09/1999 SO n 185 GU n 248 21/10/1999 Met V.2; DM 13/09/1999 SO n 185 GU n 248 21/10/1999 Met VII.3; UNI EN 17503:2022; DM 13/09/1999 SO n 185 GU n 248 21/10/1999 Met III.1; DM 13/09/1999 SO n 185 GU n 248 21/10/1999 Met II.2; UNI EN 13657:2004, APAT CNR IRSA 3020 Man 29 2003; CNR IRSA 16 Q 64 Vol 3 1986; DM 21/03/2005 GU n 79 06/04/2005 Met I.2Soil-
6chemicalRapporti ISTISAN 2019/07 pag 99 Met ISS PGA901; UNI EN ISO 19458:2006; APAT CNR IRSA 1030 Man 29 2003; UNI EN 12619:2013/EC1:2013; UNI EN 14792:2017; UNI CEN/TS 17638:2021; UNI EN 14789:2017; UNI EN ISO 16911-1:2013; UNI 10169:2001Drinking water0.5 to 650 mg/Nmc; mg/m3

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Via Leonardo da Vinci, 10/B, San Biagio di Callalta, 31048, IT

45.68487, 12.37735

Open in Maps

Accreditation data refreshed from the ACCREDIA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.