Scope lines
7
COFRAC certificate
1
Site in our directory
1
COFRAC accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 7 scope lines.

COFRAC certificate 1-7286 · 7 lines

LineMethodMatrixRange
1NF EN ISO/IEC 17025HIGH AND MEDIUM VOLTAGE SUPPLY MATERIALS-
2-matériels divers utilisés pour la distribution à haute et moyenne tension
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Accréditation n° 1-7286 LAB FORM 37 – Révision 09 – applicable 15 octobre 2022 Page 3/9 Section Laboratoires ANNEXE TECHNIQUE à l’attestation N° 1-7286 rév. 1 L’accréditation concerne les prestations réalisées par : SCHNEIDER ELECTRIC - LEMT - Laboratoire d'Essais Moyenne Tension 28 RUE HENRI TARZE 38100 GRENOBLE Dans son unité technique : - LABORATOIRE D'ESSAIS MOYENNE TENSION (LEMT) Elle est accordée selon le périmètre suivant : Electricité / Essais des matériels divers utilisés pour la distribution à haute et moyenne tension / Essais de sécurité et de performance (58) Electricity / Various materials intended for high and medium voltage distribution / Safety and performance tests (58) Pour tous les essais concernant cette accréditation : Le laboratoire est reconnu compétent, dans le domaine couvert par la portée générale, pour adopter toute méthode reconnue et pour développer ou mettre en œuvre toute autre méthode dont il aura assuré la validation. (FLEX3). La liste exhaustive des méthodes proposées sous accréditation est mise à disposition par le laboratoire. For all the tests of this accreditation: The laboratory is competent, in the field covered by the general scope, to adopt any recognized method and to develop or implement any other method for wich he has ensured validation (FLEX3). The exhaustive list of methods offered under accreditation is made available by the laboratory.
-
3-Various materials intended for high and medium voltage distribution
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Accréditation n° 1-7286 LAB FORM 37 – Révision 09 – applicable 15 octobre 2022 Page 4/9 Portée générale : Electricité / Matériels divers pour la distribution à haute et moyenne tension (58) Electricity / Various materials intended for high and medium voltage distribution (58) N° Nature de l'essai Nature of the test Objet soumis à essai Object subjected to test Caractéristique mesurée ou recherchée Caracteristics or quantities measured Principe de la méthode Principle of the method DIEL IMP Essai diélectrique (chocs de foudre) / Dielectric test (lightning impulse) Matériels divers utilisés pour la distribution à haute et moyenne tension Various materials intended for high and medium voltage distribution Tension / Voltage (kV) Forme d’onde / Wave shape (µs) Application d’une tension de choc de foudre à sec / Applying a lightning impulse voltage in dry conditions DIEL IDLI Essai diélectrique de distance de sectionnement (chocs de foudre) / Isolating distance dielectric test (Lightning impulse) Tension / Voltage (kV) Forme d’onde / Wave shape (µs) Application d’une tension de choc de foudre à sec / Applying a lightning impulse voltage in dry conditions DIEL PF Essai diélectrique (fréquence industrielle) / Dielectric test (power frequency) 50 Hz & 60 Hz Tension / Voltage (kV) Temps / Time (s) Application d’une tension de courte durée à fréquence industrielle / Applying a short-duration power-frequency voltage DIEL IDPF Essai diélectrique de distance de sectionnement (fréquence industrielle) / Isolating distance dielectric test (power frequency) Tension / Voltage (kV) Temps / Time (s) Application d’une tension de courte durée à fréquence industrielle entre contacts / Applying a short-duration power-frequency voltage between contacts
-
4-Various materials intended for high and medium voltage distribution
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Accréditation n° 1-7286 LAB FORM 37 – Révision 09 – applicable 15 octobre 2022 Page 5/9 Electricité / Matériels divers pour la distribution à haute et moyenne tension (58) Electricity / Various materials intended for high and medium voltage distribution (58) N° Nature de l'essai Nature of the test Objet soumis à essai Object subjected to test Caractéristique mesurée ou recherchée Caracteristics or quantities measured Principe de la méthode Principle of the method PD Essai de décharges partielles / Partial discharge test Matériels divers utilisés pour la distribution à haute et moyenne tension Various materials intended for high and medium voltage distribution Tension / Voltage (kV) Décharge apparente / Apparent discharge (pC) Mesure d’un niveau de DP à une tension industrielle définie / Partial discharge level measurement during test with a defined voltage DIEL BT Essai diélectrique des circuits auxiliaires et de commande / Dielectric test on auxiliary and control circuits Tension / Voltage (kV) Temps / Time (s) Application d’une tension à la fréquence industrielle / Applying a power frequency voltage TEMP RISE Essai d’échauffement / Temperature rise test Echauffement / Temperature rise (K) Mesure de l’échauffement aux points de contacts et raccords à l’aide de thermocouples / Measurement of temperature rise at connections with thermocouples MES RES Essai de mesurage de la résistance du circuit principal / Main circuit resistance measurement test Chute de tension / Voltage drop (mV) Mesure de la chute de tension sous un courant de 100 A cc / Measurement of the voltage drop under 100 Adc
-
5-Various materials intended for high and medium voltage distribution
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Accréditation n° 1-7286 LAB FORM 37 – Révision 09 – applicable 15 octobre 2022 Page 6/9 Electricité / Matériels divers pour la distribution à haute et moyenne tension (58) Electricity / Various materials intended for high and medium voltage distribution (58) N° Nature de l'essai Nature of the test Objet soumis à essai Object subjected to test Caractéristique mesurée ou recherchée Caracteristics or quantities measured Principe de la méthode Principle of the method ELM CHA Essai de fonctionnement mécanique à la température ambiante / Mechanical operation test at ambient temperature Matériels divers utilisés pour la distribution à haute et moyenne tension Various materials intended for high and medium voltage distribution Vitesse O/F (m/s) Durée O/F (ms) Courant (A) Tension (V) Couple (N.m) Force (N) / Speed O/C (m/s) Time O/C (s) Current (A) Voltage (V) Torque (N.m) Strength (N) Mesures des caractéristiques mécaniques et électriques avant et après essais / Measurements of mechanical and electrical characteristics before and after tests CLIM Essai à haute et basse température / High and low temperature test Matériels divers utilisés pour la distribution à haute et moyenne tension Various materials intended for high and medium voltage distribution Vitesse O/F (m/s) Durée O/F (ms) Courant (A) Tension (V) Couple (N.m) Force (N) / Speed O/C (m/s) Time O/C (s) Current (A) Voltage (V) Torque (N.m) Strength (N) Mesures des caractéristiques mécaniques et électriques à haute et basse température / Measurement of mechanical and electrical characteristics at high and low temperature
-
6-Various materials intended for high and medium voltage distribution
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Accréditation n° 1-7286 LAB FORM 37 – Révision 09 – applicable 15 octobre 2022 Page 7/9 Electricité / Matériels divers pour la distribution à haute et moyenne tension (58) Electricity / Various materials intended for high and medium voltage distribution (58) N° Nature de l'essai Nature of the test Objet soumis à essai Object subjected to test Caractéristique mesurée ou recherchée Caracteristics or quantities measured Principe de la méthode Principle of the method LEAK Essai d’étanchéité / Tightness test Matériels divers utilisés pour la distribution à haute et moyenne tension Various materials intended for high and medium voltage distribution Bar.cm3/s Mesure de la concentration de SF6 ou d'hélium à T0 et T1 afin de déterminer le taux de fuite / Measurement of the SF6 or helium concentration at T0 and T1 to define the leakage rate IP IK Essai de vérification du degré de protection / Verification of the protection level Pénétration / Pas pénétration / Penetration/ No penetration / Dégradation / Pas dégradation / Deterioration / Not deterioration Tenter la pénétration du calibre objet dans tout espace de l’échantillon / Attempt the penetration of the specified test probes in the enclosure / Vérification de la résistance de l‘enveloppe aux impacts mécaniques / Verification of the envelope protection against mechanicals impacts IND Essai de vérification de la fonction propre de l’indicateur de position / Verification of position indicator test Matériels divers utilisés pour la distribution à haute et moyenne tension Various materials intended for high and medium voltage distribution Etat de positionnement du synoptique / Condition of the synoptic’s positioning Vérification visuelle de l’indicateur de position par rapport à la position du sectionneur / Visual verification of the position indicator compared to the disconnector position
-
7-Various materials intended for high and medium voltage distribution
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Accréditation n° 1-7286 LAB FORM 37 – Révision 09 – applicable 15 octobre 2022 Page 8/9 Electricité / Matériels divers pour la distribution à haute et moyenne tension (58) Electricity / Various materials intended for high and medium voltage distribution (58) N° Nature de l'essai Nature of the test Objet soumis à essai Object subjected to test Caractéristique mesurée ou recherchée Caracteristics or quantities measured Principe de la méthode Principle of the method MEC END Essai de fonctionnement mécanique / Mechanical operation test Matériels divers utilisés pour la distribution à haute et moyenne tension Various materials intended for high and medium voltage distribution Vitesse O/F (m/s) Durée O/F (ms) Courant (A) Tension (V) / Speed O/C (m/s) Time O/C (s) Current (A) Voltage (V) Mesures des caractéristiques mécaniques et électriques avant et après essais / Measurement of mechanical and electrical characteristics before and after test PRES Essai mecanique / mechanical test : Tenue de pression pour les compartiments à remplissage de gaz / Pressure withstand test for gas-filled compartments Pression / Pressure (bar) Temps / Time (s) Surpression du compartiment à remplissage de gaz / Overpressure of gas filled compartment # Accréditation rendue obligatoire dans le cadre réglementaire français précisé par le texte cité en référence dans le document Cofrac LAB INF 99 disponible sur www.cofrac.fr
-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.