Poland

Pracownia Specjalistyczna Ochrony Środowiska "SILECO" S.C. Kazimierz Bek, Przemysław Bek, Patrycja Tylutko

ul. Wolności 191, 41-800, Zabrze, Poland

PCA|AB 1066ISO/IEC 17025Register refreshed 2026-09-25
Certificates
1
Scope items
5
Standards
19
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Pracownia Specjalistyczna Ochrony Środowiska "SILECO" S.C. Kazimierz Bek, Przemysław Bek, Patrycja Tylutko?

Claim this profile to keep it accurate.

Register record

PCARefreshed
AB 1066Active

Accredited standards

19

Our reading of the PCA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

EN

EN 1911Stationary source emissions - Determination of mass concentration of gaseous chlorides expressed as HCl - Standard reference method
As written on the certificate · Line 3 (PCA AB 1066)

PN- EN 12619:2013-05; PN-EN ISO 16911-1:2013-07; PN-EN 13211+AC:2006; PN-Z-04008-4:1999; PN-EN 13649:2005; PN-EN 1911:2011; ISO 15713:2006; PN-EN 14385:2005

As written on the certificate · Line 4 (PCA AB 1066)

PN-EN 14181:2015-02; PN-Z-04030-7:1994; PN-EN 14792:2006; PN-EN 14791:2017-04; PN-EN 15058:2006; PN-ISO 10396:2001; PN-EN 14789:2006; PN-EN 14790:2017-04; PN-EN 1911:2011; ISO 15713:2006; PN-EN 13211+AC:2006

EN 12619Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method
As written on the certificate · Line 3 (PCA AB 1066)

PN- EN 12619:2013-05; PN-EN ISO 16911-1:2013-07; PN-EN 13211+AC:2006; PN-Z-04008-4:1999; PN-EN 13649:2005; PN-EN 1911:2011; ISO 15713:2006; PN-EN 14385:2005

EN 13211Air quality - Stationary source emissions - Manual method of determination of the concentration of total mercury
As written on the certificate · Line 3 (PCA AB 1066)

PN- EN 12619:2013-05; PN-EN ISO 16911-1:2013-07; PN-EN 13211+AC:2006; PN-Z-04008-4:1999; PN-EN 13649:2005; PN-EN 1911:2011; ISO 15713:2006; PN-EN 14385:2005

As written on the certificate · Line 4 (PCA AB 1066)

PN-EN 14181:2015-02; PN-Z-04030-7:1994; PN-EN 14792:2006; PN-EN 14791:2017-04; PN-EN 15058:2006; PN-ISO 10396:2001; PN-EN 14789:2006; PN-EN 14790:2017-04; PN-EN 1911:2011; ISO 15713:2006; PN-EN 13211+AC:2006

EN 13284-1Stationary source emissions - Determination of low range mass concentration of dust - Part 1: Manual gravimetric method
As written on the certificate · Line 2 (PCA AB 1066)

PN-Z-04030-7:1994; PN-EN 13284-1:2018-02; PN-ISO 10396:2001; PN-EN 14792:2006; PN-EN 14791:2017-04; PN-EN 14789:2006; PN-EN 15058:2006; PN-EN 14790:2017-04

EN 13649Name not checked yet
As written on the certificate · Line 3 (PCA AB 1066)

PN- EN 12619:2013-05; PN-EN ISO 16911-1:2013-07; PN-EN 13211+AC:2006; PN-Z-04008-4:1999; PN-EN 13649:2005; PN-EN 1911:2011; ISO 15713:2006; PN-EN 14385:2005

EN 14181Stationary source emissions - Quality assurance of automated measuring systems
As written on the certificate · Line 4 (PCA AB 1066)

PN-EN 14181:2015-02; PN-Z-04030-7:1994; PN-EN 14792:2006; PN-EN 14791:2017-04; PN-EN 15058:2006; PN-ISO 10396:2001; PN-EN 14789:2006; PN-EN 14790:2017-04; PN-EN 1911:2011; ISO 15713:2006; PN-EN 13211+AC:2006

As written on the certificate · Line 5 (PCA AB 1066)

ASTM D 1739:98 (2017); PN-EN 21877:2020-03; PB-3 wydanie B z dnia 26.05.2025 r.; PB-4 wydanie B z dnia 26.05.2025 r.; PB-5 wydanie B z dnia 26.05.2025 r.; PN-EN ISO 21258:2010; VDI 2462-2:2011; PN-EN 14181:2015; PN-Z-04030-7:1994

EN 14385Stationary source emissions - Determination of the total emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl and V
As written on the certificate · Line 3 (PCA AB 1066)

PN- EN 12619:2013-05; PN-EN ISO 16911-1:2013-07; PN-EN 13211+AC:2006; PN-Z-04008-4:1999; PN-EN 13649:2005; PN-EN 1911:2011; ISO 15713:2006; PN-EN 14385:2005

EN 14789Stationary source emissions - Determination of volume concentration of oxygen - Standard reference method: Paramagnetism
As written on the certificate · Line 2 (PCA AB 1066)

PN-Z-04030-7:1994; PN-EN 13284-1:2018-02; PN-ISO 10396:2001; PN-EN 14792:2006; PN-EN 14791:2017-04; PN-EN 14789:2006; PN-EN 15058:2006; PN-EN 14790:2017-04

As written on the certificate · Line 4 (PCA AB 1066)

PN-EN 14181:2015-02; PN-Z-04030-7:1994; PN-EN 14792:2006; PN-EN 14791:2017-04; PN-EN 15058:2006; PN-ISO 10396:2001; PN-EN 14789:2006; PN-EN 14790:2017-04; PN-EN 1911:2011; ISO 15713:2006; PN-EN 13211+AC:2006

EN 14790Stationary source emissions - Determination of the water vapour in ducts - Standard reference method
As written on the certificate · Line 2 (PCA AB 1066)

PN-Z-04030-7:1994; PN-EN 13284-1:2018-02; PN-ISO 10396:2001; PN-EN 14792:2006; PN-EN 14791:2017-04; PN-EN 14789:2006; PN-EN 15058:2006; PN-EN 14790:2017-04

As written on the certificate · Line 4 (PCA AB 1066)

PN-EN 14181:2015-02; PN-Z-04030-7:1994; PN-EN 14792:2006; PN-EN 14791:2017-04; PN-EN 15058:2006; PN-ISO 10396:2001; PN-EN 14789:2006; PN-EN 14790:2017-04; PN-EN 1911:2011; ISO 15713:2006; PN-EN 13211+AC:2006

EN 14791Stationary source emissions - Determination of mass concentration of sulphur oxides - Standard reference method
As written on the certificate · Line 2 (PCA AB 1066)

PN-Z-04030-7:1994; PN-EN 13284-1:2018-02; PN-ISO 10396:2001; PN-EN 14792:2006; PN-EN 14791:2017-04; PN-EN 14789:2006; PN-EN 15058:2006; PN-EN 14790:2017-04

As written on the certificate · Line 4 (PCA AB 1066)

PN-EN 14181:2015-02; PN-Z-04030-7:1994; PN-EN 14792:2006; PN-EN 14791:2017-04; PN-EN 15058:2006; PN-ISO 10396:2001; PN-EN 14789:2006; PN-EN 14790:2017-04; PN-EN 1911:2011; ISO 15713:2006; PN-EN 13211+AC:2006

EN 14792Stationary source emissions - Determination of mass concentration of nitrogen oxides - Standard reference method: Chemiluminescence
As written on the certificate · Line 2 (PCA AB 1066)

PN-Z-04030-7:1994; PN-EN 13284-1:2018-02; PN-ISO 10396:2001; PN-EN 14792:2006; PN-EN 14791:2017-04; PN-EN 14789:2006; PN-EN 15058:2006; PN-EN 14790:2017-04

As written on the certificate · Line 4 (PCA AB 1066)

PN-EN 14181:2015-02; PN-Z-04030-7:1994; PN-EN 14792:2006; PN-EN 14791:2017-04; PN-EN 15058:2006; PN-ISO 10396:2001; PN-EN 14789:2006; PN-EN 14790:2017-04; PN-EN 1911:2011; ISO 15713:2006; PN-EN 13211+AC:2006

EN 15058Stationary source emissions - Determination of the mass concentration of carbon monoxide - Standard reference method: non-dispersive infrared spectrometry
As written on the certificate · Line 2 (PCA AB 1066)

PN-Z-04030-7:1994; PN-EN 13284-1:2018-02; PN-ISO 10396:2001; PN-EN 14792:2006; PN-EN 14791:2017-04; PN-EN 14789:2006; PN-EN 15058:2006; PN-EN 14790:2017-04

As written on the certificate · Line 4 (PCA AB 1066)

PN-EN 14181:2015-02; PN-Z-04030-7:1994; PN-EN 14792:2006; PN-EN 14791:2017-04; PN-EN 15058:2006; PN-ISO 10396:2001; PN-EN 14789:2006; PN-EN 14790:2017-04; PN-EN 1911:2011; ISO 15713:2006; PN-EN 13211+AC:2006

EN 21877Name not checked yet
As written on the certificate · Line 5 (PCA AB 1066)

ASTM D 1739:98 (2017); PN-EN 21877:2020-03; PB-3 wydanie B z dnia 26.05.2025 r.; PB-4 wydanie B z dnia 26.05.2025 r.; PB-5 wydanie B z dnia 26.05.2025 r.; PN-EN ISO 21258:2010; VDI 2462-2:2011; PN-EN 14181:2015; PN-Z-04030-7:1994

ISO

ISO 10396Stationary source emissions - Sampling for the automated determination of gas emission concentrations for permanently-installed monitoring systems
As written on the certificate · Line 2 (PCA AB 1066)

PN-Z-04030-7:1994; PN-EN 13284-1:2018-02; PN-ISO 10396:2001; PN-EN 14792:2006; PN-EN 14791:2017-04; PN-EN 14789:2006; PN-EN 15058:2006; PN-EN 14790:2017-04

As written on the certificate · Line 4 (PCA AB 1066)

PN-EN 14181:2015-02; PN-Z-04030-7:1994; PN-EN 14792:2006; PN-EN 14791:2017-04; PN-EN 15058:2006; PN-ISO 10396:2001; PN-EN 14789:2006; PN-EN 14790:2017-04; PN-EN 1911:2011; ISO 15713:2006; PN-EN 13211+AC:2006

ISO 15713Stationary source emissions - Sampling and determination of gaseous fluoride content
As written on the certificate · Line 3 (PCA AB 1066)

PN- EN 12619:2013-05; PN-EN ISO 16911-1:2013-07; PN-EN 13211+AC:2006; PN-Z-04008-4:1999; PN-EN 13649:2005; PN-EN 1911:2011; ISO 15713:2006; PN-EN 14385:2005

As written on the certificate · Line 4 (PCA AB 1066)

PN-EN 14181:2015-02; PN-Z-04030-7:1994; PN-EN 14792:2006; PN-EN 14791:2017-04; PN-EN 15058:2006; PN-ISO 10396:2001; PN-EN 14789:2006; PN-EN 14790:2017-04; PN-EN 1911:2011; ISO 15713:2006; PN-EN 13211+AC:2006

ISO 16911-1Stationary source emissions - Manual and automatic determination of velocity and volume flow rate in ducts - Part 1: Manual reference method
As written on the certificate · Line 3 (PCA AB 1066)

PN- EN 12619:2013-05; PN-EN ISO 16911-1:2013-07; PN-EN 13211+AC:2006; PN-Z-04008-4:1999; PN-EN 13649:2005; PN-EN 1911:2011; ISO 15713:2006; PN-EN 14385:2005

ISO 21258Stationary source emissions - Determination of the mass concentration of dinitrogen monoxide (N2O) - Reference method: Non-dispersive infrared method
As written on the certificate · Line 5 (PCA AB 1066)

ASTM D 1739:98 (2017); PN-EN 21877:2020-03; PB-3 wydanie B z dnia 26.05.2025 r.; PB-4 wydanie B z dnia 26.05.2025 r.; PB-5 wydanie B z dnia 26.05.2025 r.; PN-EN ISO 21258:2010; VDI 2462-2:2011; PN-EN 14181:2015; PN-Z-04030-7:1994

Other standards

ASTM D1739Name not checked yet
As written on the certificate · Line 5 (PCA AB 1066)

ASTM D 1739:98 (2017); PN-EN 21877:2020-03; PB-3 wydanie B z dnia 26.05.2025 r.; PB-4 wydanie B z dnia 26.05.2025 r.; PB-5 wydanie B z dnia 26.05.2025 r.; PN-EN ISO 21258:2010; VDI 2462-2:2011; PN-EN 14181:2015; PN-Z-04030-7:1994

PN-Z-04030-7:1994Name not checked yet
As written on the certificate · Line 2 (PCA AB 1066)

PN-Z-04030-7:1994; PN-EN 13284-1:2018-02; PN-ISO 10396:2001; PN-EN 14792:2006; PN-EN 14791:2017-04; PN-EN 14789:2006; PN-EN 15058:2006; PN-EN 14790:2017-04

As written on the certificate · Line 4 (PCA AB 1066)

PN-EN 14181:2015-02; PN-Z-04030-7:1994; PN-EN 14792:2006; PN-EN 14791:2017-04; PN-EN 15058:2006; PN-ISO 10396:2001; PN-EN 14789:2006; PN-EN 14790:2017-04; PN-EN 1911:2011; ISO 15713:2006; PN-EN 13211+AC:2006

As written on the certificate · Line 5 (PCA AB 1066)

ASTM D 1739:98 (2017); PN-EN 21877:2020-03; PB-3 wydanie B z dnia 26.05.2025 r.; PB-4 wydanie B z dnia 26.05.2025 r.; PB-5 wydanie B z dnia 26.05.2025 r.; PN-EN ISO 21258:2010; VDI 2462-2:2011; PN-EN 14181:2015; PN-Z-04030-7:1994

Scope as published by PCA

5 lines
PCA

ISO/IEC 17025

Active

AB 1066

The scope document we hold says it is valid until 2029-07-08.

View on PCA

Accredited scope, certificate AB 1066

LineDisciplineMethodMatrixRange
1environmental-Ambient air-
2environmentalPN-Z-04030-7:1994; PN-EN 13284-1:2018-02; PN-ISO 10396:2001; PN-EN 14792:2006; PN-EN 14791:2017-04; PN-EN 14789:2006; PN-EN 15058:2006; PN-EN 14790:2017-04Flue gas0.001 to 100 g/m3
3environmentalPN- EN 12619:2013-05; PN-EN ISO 16911-1:2013-07; PN-EN 13211+AC:2006; PN-Z-04008-4:1999; PN-EN 13649:2005; PN-EN 1911:2011; ISO 15713:2006; PN-EN 14385:2005Flue gas1 to 5000 mg/m3
4environmentalPN-EN 14181:2015-02; PN-Z-04030-7:1994; PN-EN 14792:2006; PN-EN 14791:2017-04; PN-EN 15058:2006; PN-ISO 10396:2001; PN-EN 14789:2006; PN-EN 14790:2017-04; PN-EN 1911:2011; ISO 15713:2006; PN-EN 13211+AC:2006Air0.001 to 5000 g/m3; mg/m3; %
5environmentalASTM D 1739:98 (2017); PN-EN 21877:2020-03; PB-3 wydanie B z dnia 26.05.2025 r.; PB-4 wydanie B z dnia 26.05.2025 r.; PB-5 wydanie B z dnia 26.05.2025 r.; PN-EN ISO 21258:2010; VDI 2462-2:2011; PN-EN 14181:2015; PN-Z-04030-7:1994Ambient air0.001 to 980 g/m2; mg/m3

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

ul. Wolności 191, Zabrze, 41-800, PL

50.30862, 18.78637

Open in Maps

Accreditation data refreshed from the PCA register on .