Electronic Laboratories Inc.

Westminster, MD, United States

Visit website
A2LA 6785.01ISO/IEC 17025Register refreshed 2026-10-23

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
11
A2LA certificate
1
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 11 scope lines.

A2LA certificate 6785.01 · 11 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6785.01) 10/03/2025 Page 1 of 10 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 ELECTRONIC LABORATORIES INC. 75 Aileron Court, Suite 6 Westminster, MD 21157 Frank Hanky Phone: 443 340 1211 CALIBRATION Valid To: August 31, 2027 Certificate Number: 6785.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations1,5: I. Electrical/DC Low Frequency Parameter/Equipment Range CMC2, 4, 6 (±) Comments DC Voltage – Generate3 Up to 100 mV (0.001 to 1) V (1 to 10) V (10 to 120) V (120 to 1020) V 0.0026 % + 0.8 µV 0.000 72 % + 1 µV 0.000 66 % + 10 µV 0.000 92 % + 100 µV 0.000 86 % + 1000 µV Fluke 5560A/SC1100 DC Voltage – Measure3 Up to 100 mV (0.1 to 1) V (1 to 10) V (10 to 100) V (100 to 1000) V 17µV/V + 0.30 µV 9.7 µV/V + 0.30 µV 9.4 µV/V + 0.50 µV 12 µV/V + 30 µV 13 µV/V + 0.1 mV Agilent 3458A DC Current – Generate3 Up to 120 µA (0.12 to 1.2) mA (1.2 to 12) mA (12 to 120) mA (0.12 to 1.2) A (1.2 to 3.1) A (3.1 to 12) A (12 to 30.2) A 92 µA/A + 0.006 µA 480 µA/A + 0.015 µA 490 µA/A + 0.08 µA 490 µA/A + 0.8 µA 520 µA/A + 0.01 µA 76 µA/A + 0.15 µA 720 µA/A + 0.25 µA 830 µA/A + 0.5 µA Fluke 5560A/SC1100
to 1020 V
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6785.01) 10/03/2025 Page 2 of 10 Parameter/Equipment Range CMC2, 4, 6 (±) Comments DC Current – Measure3 Up to 100 µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A 23 µA/A + 0.80 nA 23 µA/A + 5.0 nA 23 µA/A + 50 nA 39 µA/A + 0.5 µA 110 µA/A + 10 µA Agilent 3458A Parameter/Range Frequency CMC2, 4, 6 (±) Comments AC Voltage – Generate3 Up to 12 mV (12 to 120) mV (0.12 to 1.2) V (1.2 to 12) V (12 to 120) V Up to 5 Hz 5 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz Up to 5 Hz 5 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz Up to 5 Hz (5 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz Up to 5 Hz (5 Hz to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz Up to 5 Hz (5 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz 3.9 % + 0.007 mV 0.0092 % + 0.006 mV 0.024 % + 0.006 mV 0.092 % + 0.015 mV 0.57 % + 0.03 mV 0.58 % + 0.03 mV 0.078 % + 0.007 mV 0.0043 % + 0.006 mV 0.011 % + 0.008 mV 0.027 % + 0.02 mV 0.06 % + 0.03 mV 0.063 % + 0.03 mV 0.078 % + 0.075 mV 0.0047 % + 0.06 mV 0.0067 % + 0.008 mV 0.01 % + 0.014 mV 0.022 % + 0.04 mV 0.087 % + 0.08 mV 0.091 % + 0.08 mV 0.078 % + 0.75 mV 0.0062 % + 0.35 mV 0.02 % + 0.05 mV 0.012 % + 0.05 mV 0.025 % + 0.13 mV 0.023 % + 0.6 mV 0.025 % + 0.6 mV 0.078 % + 7.5 mV 0.0062 % + 3.5 mV 0.0062 % + 0.5 mV 0.011 % + 0.5 mV 0.022 % + 1.3 mV Fluke 5560A/SC1100
3--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6785.01) 10/03/2025 Page 3 of 10 Parameter/Range Frequency CMC2, 4, 6 (±) Comments AC Voltage – Generate3 (cont) (120 to 330) V Up to 5 Hz (5 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz 0.078 % + 7.5 mV 0.0062 % + 3.5 mV 0.0062 % + 0.5 mV 0.011 % + 0.5 mV 0.022 % + 1.3 mV Fluke 5560A/SC1100 AC Voltage – Measure3 Up to 100 mV 100 mV to 1 V (1 to 10) V Up to 40 Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 4) MHz (4 to 8) MHz (8 to 10) MHz Up to 40 Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 4) MHz (4 to 8) MHz (8 to 10) MHz Up to 40 Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 4) MHz (4 to 8) MHz (8 to 10) MHz 0.008 % + 4 µV 0.008 % + 2 µV 0.015 % + 2 µV 0.033 % + 2 µV 0.088 % + 2 µV 0.3 % + 10 µV 1.2 % + 10 µV 4.0 % + 70 µV 4.0 % + 80 µV 15 % + 0.1 mV 0.007 % + 40 µV 0.0074 % + 20 µV 0.014 % + 20 µV 0.03 % + 20 µV 0.08 % + 20 µV 0.3 % + 100 µV 1.1 % + 100 µV 4.0 % + 0.7 mV 4.0 % + 0.8 mV 15 % + 1.0 mV 0.008 % + 0.4 mV 0.0075 % + 0.2 mV 0.014 % + 0.2 mV 0.03 % + 0.2 mV 0.08 % + 0.2 mV 0.3 % + 1.0 mV 0.99 % + 1.0 mV 4.0 % + 7.0 mV 4.0 % + 8.0 mV 15 % + 10 mV Agilent 3458A
120 to 330 V
4--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6785.01) 10/03/2025 Page 4 of 10 Parameter/Range Frequency CMC2, 4, 6 (±) Comments AC Voltage – Measure3 (cont) (10 to 100) V Up to 40 Hz 40Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 0.02 % + 4.0 mV 0.02 % + 2.0 mV 0.02 % + 2.0 mV 0.036 % + 2.0 mV 0.12 % + 2.0 mV Agilent 3458A AC Current – Generate3 (Up to 120) µA 120 µA to 1.2 mA (1.2 to 12) mA (12 to 120) mA 120 mA to 1.2A Up to 3 Hz (3 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz Up to 3 Hz (3 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz Up to 10 Hz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz Up to 3 Hz (3 to 45) Hz 45 Hz to 1kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz Up to 3 Hz (3 to 45) Hz 45 Hz to 1kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 0.042 % + 0.01 µA 0.053 % + 0.01 µA 0.057 % + 0.01 µA 0.056 % + 0.01 µA 0.09 % + 0.04 µA 2.9 % + 0.1 µA 0.0023 % + 0.1 µA 0.0023 % + 0.1 µA 0.0022 % + 0.1 µA 0.0022 % + 0.1 µA 0.014 % + 0.1 µA 0.036 % + 5.0 µA 0.022 % + 0.1 µA 0.022 % + 0.1 µA 0.022 % + 0.1 µA 0.022 % + 0.1 µA 0.14 % + 0.1 µA 0.44 % + 10 µA 0.022 % + 0.01 mA 0.021 % + 0.01 mA 0.013 % + 0.005 mA 0.022 % + 0.008 mA 0.12 % + 0.1 mA 0.44 % + 0.1 mA 0.022 % + 0.1 mA 0.024 % + 0.1 mA 0.029 % + 0.05 mA 0.026 % + 0.08 mA 0.004 % + 0.3 mA 0.46 % + 0.3 mA Fluke 5560A/SC1100
10 to 100 V
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6785.01) 10/03/2025 Page 5 of 10 Parameter/Range Frequency CMC2, 4, 6 (±) Comments AC Current – Generate3 (cont) (1.2 to 3.1) A (3.1 to 12) A (12 to 30.2) A Up to 3 Hz (3 to 45) Hz 45 Hz to 1kHz (1 to 5) kHz (5 to 10) kHz Up to 3 Hz (3 to 45) Hz 45 Hz to 1kHz (1 to 5) kHz (5 to 10) kHz Up to 3 Hz (3 to 45) Hz 45 Hz to 1kHz 0.0071 % + 0.1 mA 0.0077 % + 0.1 mA 0.0094 % + 0.05 mA 0.0084 % + 0.08 mA 0.0013 % + 0.3 mA 0.042 % + 0.1 mA 0.042 % + 0.1 mA 0.032 % + 0.05 mA 0.031 % + 0.08 mA 0.029 % + 0.3 mA 0.16 % + 0.5 mA 0.16 % + 0.5 mA 0.12 % + 0.3 mA Fluke 5560A/SC1100 AC Current – Measure3 Up to 100 µA (0.1 to 1) mA (1 to 10) mA Up to 10 Hz (10 to 40) Hz (40 to 100) Hz 100 Hz to 1 kHz Up to 10 Hz (10 to 40) Hz (40 to 100) Hz 100 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz Up to 10 Hz (10 to 40) Hz (40 to 100) Hz 100 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 0.40 % + 0.03 µA 0.15 % + 0.03 µA 0.065 % + 0.03 µA 0.065 % + 0.03 µA 0.40 % + 0.2 µA 0.15 % + 0.2 µA 0.068 % + 0.2 µA 0.042 % + 0.2 µA 0.068 % + 0.2 µA 0.40 % + 0.4 µA 0.55 % + 1.5 µA 0.40 % + 2 µA 0.15 % + 2 µA 0.062 % + 2 µA 0.033 % + 2 µA 0.064 % + 2 µA 0.40 % + 4 µA 0.55 % + 15 µA Agilent 3458A
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6785.01) 10/03/2025 Page 6 of 10 Parameter/Range Frequency CMC2, 4, 6 (±) Comments AC Current – Measure3 (cont) (10 to 100) mA (0.1 to 1) A Up to 10 Hz (10 to 40) Hz (40 to 100) Hz 100 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz Up to 10 Hz (10 to 40) Hz (40 to 100) Hz 100 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz 0.40 % + 20 µA 0.15 % + 20 µA 0.062 % + 20 µA 0.033 % + 20 µA 0.062 % + 20 µA 0.40 % + 40 µA 0.55 % + 0.15 mA 0.40 % + 0.2 mA 0.16 % + 0.2 mA 0.08 % + 0.2 mA 0.10 % + 0.2 mA 0.30 % + 0.2 mA 0.96 % + 0.4 mA Agilent 3458A Parameter/Equipment Range CMC2, 4, 6 (±) Comments Resistance – Generate3 Up to 12 Ω (12 to 120) Ω (120 to 1200) Ω (1.2 to 12) kΩ (12 to 120) kΩ 120 kΩ to 1.2 MΩ (1.2 to 12) MΩ (12 to 120) MΩ (120 to 1200) MΩ 0.004 % + 0.001 Ω 0.0022 % + 0.001 Ω 0.0019 % + 0.002 Ω 0.012 % + 0.02 Ω 0.0022 % + 0.02 Ω 0.0027 % + 0.002 Ω 0.0029 % + 0.03 kΩ 0.035 % + 0.0025 MΩ 0.33 % + 0.1 MΩ Fluke 5560A/SC1100 Resistance – Measure3 Up to 10 Ω (10 to 100) Ω (0.1 to 1) kΩ (1 to 10) kΩ (10 to 100) kΩ (0.1 to 1) MΩ (1 to 10) MΩ (10 to 100) MΩ (0.1 to 1) GΩ 0.0018 % + 50 μΩ 0.0017 % + 0.5 mΩ 0.0013 % + 0.5 mΩ 0.0012 % + 5.0 mΩ 0.0013 % + 50 mΩ 0.0019 % + 2 Ω 0.0056 % + 100 Ω 0.051 % + 1.0 kΩ 0.52 % + 10 kΩ Agilent 3458A
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6785.01) 10/03/2025 Page 7 of 10 Parameter/Equipment Range CMC2, 4, 6 (±) Comments Capacitance – Generate3 Up to 350 pF 350 pF to 1.1 nF (1.1 to 1.2) nF (1.2 to 11) nF (11 to 12) nF (12 to 110) nF (110 to 120) nF 120 nF to 1.1 μF (1.1 to 1.2) μF (1.2 to 11) μF (11 to 12) μF (12 to 110) μF (110 to 120) μF 120 μF to 1.1 mF (1.1 to 1.2) mF (1.2 to 11) mF (11 to 12) mF (12 to 120) mF 0.017 % + 0.004 nF 0.036 % + 0.004 nF 0.025 % + 0.004 nF 0.1 % + 0.005 nF 0.06 % + 0.005 nF 0.11 % + 0.03 nF 0.11 % + 0.03 nF 0.11 % + 0.0003 μF 0.11 % + 0.0003 μF 0.14 % + 0.008 nF 0.12 % + 0.008 nF 0.14 % + 0.025 nF 0.12 % + 0.025 nF 0.56 % + 0.25 nF 0.52 % + 0.25 nF 0.35 % + 0.01 mF 0.21 % + 0.003 nF 0.36 % + 0.03 nF Fluke 5560A/SC1100 Electrical Simulation of RTDs3 Pt 385; 100 Ω (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C 0.039 °C 0.039 °C 0.055 °C 0.070 °C 0.078 °C 0.094 °C 0.18 °C Fluke 5560A/SC1100 Electrical Simulation of Thermocouples - Source & Measure3 Type J Type K Type T Up to -190 °C (-190 to -100) °C (-100 to 150) °C (150 to 750) °C (750 to 1200) °C Up to -190 °C (-190 to -100) °C (-100 to 120) °C (120 to 1000) °C (1000 to 1350) °C Up to -190 °C (-190 to -150) °C (-150 to 120) °C (120 to 400) °C 0.42 °C 0.20 °C 0.18 °C 0.19 °C 0.23 °C 0.56 °C 0.23 °C 0.26 °C 0.29 °C 0.41 °C 0.67 °C 0.51 °C 0.25 °C 0.19 °C Fluke 5560A/SC1100
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6785.01) 10/03/2025 Page 8 of 10 Parameter/Equipment Range CMC2, 4 (±) Comments Oscilloscope3 – Amplitude/Vertical Gain Characteristics – DC (Z = 50 Ω) DC (Z = 1 MΩ) Square Wave 10 Hz to 10 kHz (Z = 50 Ω) 10 Hz to 10 kHz (Z = 1 MΩ) Rise Time 5 mVp-p to 2.5 Vp-p 1 kHz to 10 MHz Leveled Sine Wave 5 mVp-p to 5.5 Vp-p Time Marker Up to 25 mV (25 to 110) mV (0.11 to 2.2) V (2.2 to 6.6) V Up to 25 mV (25 to 110) mV (0.11 to 2.2) V (2.2 to 11) V (11 to 130) V (1 to 25) mV (25 to 110) mV (0.11 to 2.2) V (2.2 to 6.6) V (1 to 25) mV (25 to 110) mV (0.11 to 2.2) V (2.2 to 11) V (11 to 130) V (≤300) ps 50 kHz (reference) 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz (600 to 1100) MHz (2 to 5) ns 10 ns (20 to 50) ns 100 ns to 20 ms 50 ms to 5 s 0.24 % + 40 µV 0.25 % + 40 µV 0.36 % + 40 µV 0.27 % + 40 µV 0.052 % + 40 μV 0.72 % + 40 μV 0.27 % + 40 μV 0.073 % + 40 μV 0.052 % + 40 μV 0.26 % + 40 μV 0.25 % + 40 μV 0.38 % + 40 μV 0.28 % + 40 μV 0.11 % + 40 μV 0.10 % + 40 μV 0.54 % + 40 μV 0.15 % + 40 μV 0.10 % + 40 μV 100 ps 2.1 % + 300 μV 3.6 % + 300 μV 4.1 % + 300 μV 6.0 % + 300 μV 7.0 % + 300 μV 200 µs/s 1000 µs/s 200 µs/s 320 µs/s (25 + 1000t) µs/s Fluke 5560A/SC1100 t = time marker period
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6785.01) 10/03/2025 Page 9 of 10 II. Mechanical Parameter/Equipment Range CMC2, 4, 7 (±) Comments Torque – Measuring Equipment3 (5 to 50) lbf·in (50 to 500) lbf·in (25 to 250) lbf·ft (75 to 750) lbf·ft 0.56 % 0.44 % + 0.10 lbf·in 0.51 % + 0.033 lbf·ft 0.45 % + 0.20 lbf·ft AWS torque transducers Tachometers3 Non-Contact (60 to 100) RPM (100 to 1000) RPM (>1000 to 10 000) RPM (>10 000 to 100 000) RPM 0.027 RPM 0.25 RPM 0.8 RPM 2.0 RPM Fluke 5560A/SC1100 Rotational Speed – Measure3 Non-Contact (10 to 100) RPM (>100 to 1000) RPM (>1000 to 10 000) RPM (>10 000 to 100 000) RPM 1.7 RPM 1.9 RPM 3.9 RPM 12 RPM Shimpo DT-207LR III. Thermodynamic Parameter/Equipment Range CMC2 (±) Comments Relative Humidity – Measure3 (15 to 40) % RH (>40 to 90) % RH (90 to 95) % RH 1.3 % RH 1.7 % RH 2.3 % RH Vaisala HMI41/HMP46 IV. Time & Frequency Parameter/Equipment Range CMC2, 4 (±) Comments Frequency – Generate3 Up to 120 Hz (120 to 1200) Hz (1.2 to 12) kHz (12 to 120) kHz (120 to 1200) kHz (1.2 kHz to 2MHz 0.33 % + 5 µHz 0.000 21 % + 5 µHz 0.058 % + 5 µHz 0.0059 % + 5 µHz 0.000 61 % + 5 µHz 0.29 % + 5 µHz Fluke 5560A/SC1100 ____________________________________________
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6785.01) 10/03/2025 Page 10 of 10 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavio r of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects suc h as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of the CMC, percent (%) indicates percent of indicated value. 5 This scope meets A2LA P112 Flexible Scope Policy. 6 The measurands stated are measured with the Agilent 3458A series of instruments. This capability is suitable for the calibration of the devices intended to generate the measurand in the ranges indicated. CMC are expressed as either a specific value that covers the full range or as a combination of the fraction of the reading/output plus a range specification. (Certain parameters are available as fixed source input values only (e. g. Resistance). 7 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification.
11ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.