Registers refreshed 2026-11-08.See refresh dates
United States

Electro Rent Corporation

15385 Oxnard Street, 91411, Van Nuys, CA, United States

Visit website
A2LA 2562.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
23
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 23 scope lines.

A2LA certificate 2562.01 · 23 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540.3-2006-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2562.01) 06/24/2025 Page 2 of 22 Parameter/Equipment Range CMC2, 8, 10 (±) Comments DC Voltage – Generate & Measure (cont) Measure (1.2 to 12) V (12 to 120) V (120 to 1100) V Up to 200 mV (0.2 to 2) V (2 to 20) V (20 to 200) V (200 to 1050) V 1.8 µV/V + 18 µV 3.1 µV/V + 0.18 mV 2.9 µV/V + 1.7 mV 1.8 µV/V + 0.31 µV 2.3 µV/V + 0.56 µV 2.4 µV/V + 3.3 µV 4.4 µV/V + 91 µV 4.2 µV/V + 0.66 mV AT 3458A, option II Fluke 8508A DC Current – Generate & Measure Fixed Points Generate Measure 100 µA 1 mA 10 mA 20 mA 100 mA 200 mA 1 A 10 A 20 A Up to 220 µA (0.22 to 2.2) mA (2.2 to 22) mA (22 to 220) mA 220 mA to 2.2 A (10 to 100) µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA 100 mA to 1 A 1.9 nA 14 nA 0.14 µA 0.28 µA 1.4 µA 2.8 µA 20 µA 0.55 mA 1.1 mA 40 µA/A + 5.5 nA 33 µA/A + 6.2 nA 45 µA/A + 39 nA 48 µA/A + 0.62 µA 70 µA/A + 12 µA 50 µA/A + 0.2 nA 50 µA/A + 1.5 nA 50 µA/A + 9.8 nA 0.012 % + 98 nA 0.014 % + 0.98 µA Guildline 9334A 4 Guildline 9330 4 Fluke Y50204 Fluke 5700A/EP AT 3458A
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2562.01) 06/24/2025 Page 3 of 22 Parameter/Range12 Frequency CMC2, 8, 11 (±) Comments AC Voltage – Generate & Measure 13 1 mV 2 mV 10 mV 20 mV (10 to 30) Hz (30 to 1000) Hz (1 to 120) kHz (120 to 500) kHz (500 to 1000) kHz (1 to 2) MHz (2 to 3) MHz (3 to 5) MHz (5 to 10) MHz (10 to 20) MHz (20 to 30) MHz (10 to 30) Hz (30 to 1000) Hz (1 to 120) kHz (120 to 500) kHz (500 to 1000) kHz (1 to 2) MHz (2 to 3) MHz (3 to 5) MHz (5 to 10) MHz (10 to 20) MHz (20 to 30) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (1 to 2) MHz (2 to 3) MHz (3 to 5) MHz (5 to 10) MHz (10 to 20) MHz (20 to 30) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz 0.22 % 0.19 % 0.19 % 0.20 % 0.20 % 0.20 % 0.28 % 0.28 % 0.28 % 0.40 % 0.84 % 0.22 % 0.19 % 0.19 % 0.20 % 0.20 % 0.14 % 0.24 % 0.24 % 0.24 % 0.37 % 0.83 % 0.04 % 0.033 % 0.02 % 0.032 % 0.045 % 0.097 % 0.14 % 0.09 % 0.09 % 0.13 % 0.13 % 0.13 % 0.21 % 0.44 % 0.03 % 0.019 % 0.014 % Fluke 5790A AC standard w/ 5720A calibrator
4--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2562.01) 06/24/2025 Page 4 of 22 Parameter/Range12 Frequency CMC2, 8, 11 (±) Comments AC Voltage – Generate & Measure 13 (cont) 20 mV 100 mV 70 mV 200 mV (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (1 to 2) MHz (2 to 3) MHz (3 to 5) MHz (5 to 10) MHz (10 to 20) MHz (20 to 30) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (1 to 2) MHz (2 to 3) MHz (3 to 5) MHz (5 to 10) MHz (10 to 20) MHz (20 to 30) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (1 to 2) MHz (2 to 3) MHz (3 to 5) MHz (5 to 10) MHz (10 to 20) MHz (20 to 30) MHz 0.025 % 0.034 % 0.080 % 0.11 % 0.093 % 0.093 % 0.13 % 0.13 % 0.13 % 0.21 % 0.44 % 0.023 % 0.10 % 46 µV/V 70 µV/V 0.015 % 0.023 % 0.037 % 0.067 % 0.063 % 0.12 % 0.12 % 0.12 % 0.18 % 0.41 % 0.019 % 83 µV/V 33 µV/V 49 µV/V 0.0072 % 0.016 % 0.027 % 0.061 % 0.063 % 0.13 % 0.13 % 0.13 % 0.19 % 0.42 % Fluke 5790A AC standard w/ 5720A calibrator
20 to 30 MHz
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2562.01) 06/24/2025 Page 5 of 22 Parameter/Range12 Frequency CMC2, 8, 11 (±) Comments AC Voltage – Generate & Measure 13 (cont) 1 V 2 V 3 V 10 V 20 V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (1 to 2) MHz (2 to 3) MHz (3 to 5) MHz (5 to 10) MHz (10 to 20) MHz (20 to 30) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (0.5 to 1) MHz (1 to 2) MHz (2 to 3) MHz (3 to 5) MHz (5 to 10) MHz (10 to 20) MHz (20 to 30) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz 0.017 % 61 µV/V 22 µV/V 37 µV/V 56 µV/V 0.013 % 0.021 % 0.066 % 0.068 % 0.13 % 0.13 % 0.13 % 0.19 % 0.42 % 0.017 % 60 µV/V 21 µV/V 37 µV/V 56 µV/V 0.013 % 0.021 % 0.070 % 0.076 % 0.080 % 0.14 % 0.15 % 0.15 % 0.26 % 0.55 % 0.016 % 59 µV/V 22 µV/V 38 µV/V 63 µV/V 0.015 % 0.032 % 0.094 % 0.016 % 59 µV/V 22 µV/V Fluke 5790A AC standard w/ 5720A calibrator
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2562.01) 06/24/2025 Page 6 of 22 Parameter/Range12 Frequency CMC2, 8, 11 (±) Comments AC Voltage – Generate & Measure 13 (cont) 20 V 44 V 60 V 100 V 200 V 5725 A Range: 300 V 5725A 750V Range: 600 V 1000 V (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (300 to 500) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz 50 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz 50 Hz to 1 kHz 40 Hz to 20 kHz 38 µV/V 63 µV/V 0.015 % 0.032 % 0.094 % 0.032 % 0.016 % 60 µV/V 26 µV/V 45 µV/V 73 µV/V 0.016 % 0.017 % 62 µV/V 25 µV/V 54 µV/V 77 µV/V 0.017 % 63 µV/V 25 µV/V 54 µV/V 76 µV/V 0.031 % 0.031 % 0.11 % 0.029 % 0.029 % 0.11 % 0.010 % 0.029 % Fluke 5790A AC standard w/ 5720A calibrator Fluke 5790A/3 AC standard w/ 5720A/3 calibrator 5725A amplifier Fluke 5790A AC standard w/ 5720A calibrator 5725A amplifier
7--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2562.01) 06/24/2025 Page 7 of 22 Parameter/Range12 Frequency CMC2, 8, 11 (±) Comments AC Current – Measure 100 µA 1 mA 10 mA 100 mA 1 A 10 A 11 A 20 A 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz (45, 4500, 1000) Hz (45, 500, 1000) Hz (45, 500, 1000) Hz 0.017 % 0.014 % 0.014 % 0.016 % 0.028 % 1.2 mA 1.3 mA 2.2 mA AT 3458A AT 3458A DMM & Y5020A shunt AC Current – Generate (0 to 220) µA (0.22 to 2.2) mA (2.2 to 22) mA (22 to 220) mA (0.22 to 2.2) A (10 to 20) Hz (20 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz 0.023 % + 0.022 µA 0.016 % + 0.015 µA 0.011 % + 0.013 µA 0.027 % + 0.034 µA 0.10 % + 0.081 µA 0.023 % + 0.15 µA 0.016 % + 0.10 µA 0.011 % + 0.095 µA 0.019 % + 0.17 µA 0.10 % + 0.64 µA 0.023 % + 2.4 µA 0.016 % + 1.3 µA 0.011 % + 0.95 µA 0.019 % + 1.4 µA 0.10 % + 5.0 µA 0.023 % + 24 µA 0.016 % + 12 µA 0.011 % + 93 µA 0.019 % + 13 µA 0.1 % + 47 µA 0.025 % + 140 µA 0.025 % + 140 µA 0.025 % + 140 µA 0.039 % + 160 µA 0.62 % + 890 µA Fluke 5700A/EP
0 to 220 µA
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2562.01) 06/24/2025 Page 8 of 22 Parameter/Range12 Frequency CMC2, 8 (±) Comments AC Current – Generate (cont) (3 to 10.9999) A (11 to 20.5) A (100 to 1000) A* (45 to 100) Hz (100 to 1000) Hz (1 to 5) kHz (45 to 100) Hz (100 to 1000) Hz (1 to 5) kHz (50 to 400) Hz 0.42 mA/A + 0.84 mA 0.74 mA/A + 0.59 mA 23 mA/A + 22 µA 0.91 mA/A + 1.1 mA 1.1 mA/A + 0.87 mA 25 mA/A + 42 µA 0.24 % + 0.02 A Fluke 5520A Fluke coil *coil ampere turns Phase – Generate Sinewave Voltage to Voltage (10 to 65) Hz (65 to 500) Hz (0.5 to 1) kHz (1 to 5) kHz 0.67° 0.17° 0.33° 1.7° Fluke 5520A Parameter/Equipment Range CMC2, 8 (±) Comments Resistance – Generate & Measure Fixed Points 4 Measure Only 5 1 Ω 10 Ω 100 Ω 1 kΩ 10 kΩ 100 kΩ 1 MΩ 10 MΩ 100 MΩ 1000 MΩ (0.01 to 1) Ω (1 to 10) Ω (10 to 100) Ω (100 to 1000) Ω (1 to 10) kΩ 7.6 µΩ/Ω 14 µΩ/Ω 3.1 µΩ/Ω 3.8 µΩ/Ω 3.6 µΩ/Ω 5.0 µΩ/Ω 6.6 µΩ/Ω 27 µΩ/Ω 39 µΩ/ Ω 99 µΩ/Ω 14 µΩ/Ω + 84 µΩ 14 µΩ/Ω + 84 µΩ 12 µΩ/Ω + 800 µΩ 11 µΩ/Ω + 2.5 mΩ 11 µΩ/Ω + 25 mΩ Guildline 9334A Keysight 3458A
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2562.01) 06/24/2025 Page 9 of 22 Parameter/Equipment Range CMC2, 8, 11 (±) Comments Resistance – Generate & Measure (cont) Measure Only 5 (10 to 100) kΩ (100 to 1000) kΩ (1 to 10) MΩ (10 to 100) MΩ (0.01 to 1.9999) Ω (0.1 to 19.999) Ω (1 to 199.99) Ω (10 to 19 999) Ω (0.1 to 19.999) kΩ (1 to 199.99) kΩ (10 to 19 999) kΩ (0.1 to 19.999) MΩ (1 to 199.99) MΩ (10 to 1999.9) MΩ 11 µΩ/Ω + 250 mΩ 11 µΩ/Ω + 7 Ω 44 µΩ/Ω + 150 Ω 0.036 % + 1.5 kΩ 4.3 µΩ/Ω + 9.5 µΩ 4.1 µΩ/Ω + 31 µΩ 4.4 µΩ/Ω + 230 µΩ 4.6 µΩ/Ω + 1.8 mΩ 4.8 µΩ/Ω + 14 mΩ 4.3 µΩ/Ω + 240 mΩ 3.7 µΩ/Ω + 4.3 Ω 3.3 µΩ/Ω + 120 Ω 6.5 µΩ/Ω + 7.8 kΩ 0.016 % + 840 kΩ Keysight 3458A Fluke 8508A Oscilloscope – Generate, Amplitude Volt Measure, Resistance AC Voltage Bandwidth – Generate & Measure Pulse – Generate & Measure Transition Time (Generate) 0 V (0.9 to 80) mV (0.08 to 2) V (2 to 20) V (20 to 200) V 50 Ω 1 MΩ 50 kHz to 550 MHz 50 kHz to 3.2 GHz 50 MHz to 33 GHz (70, 500) ps 25 µV 0.049 % + 25 µV 0.069 % + 64 µV 0.069 % + 1.4 mV 0.069 % + 14 mV 1.4 mΩ 19 Ω 3.3 % 3.7 % 3.0 % 6.4 ps + (-0.12 + 30t ) ps Tektronix 9500B oscilloscope calibrator Keysight 3458A 9500B 9500B & 9560 8487A sensor E8257 generator 9500B, 9560 t = transition time in ps
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2562.01) 06/24/2025 Page 10 of 22 Parameter/Equipment Range CMC2, 8, 11 (±) Comments Oscilloscope – (cont) Pulse – Generate & Measure Measure Generate Only – Transition Time 20 ps to 20 ns < 20 ps 6.4 ps + (0.12 + 30t ) ps 5.3 ps SD24/11801C t = transition time in ps Tek 067-1338-00 II. Electrical – RF/Microwave Parameter/Range Frequency CMC 2, 8, 11 (±) Comments Milliwatt Reference – Power – Measure: 1 mW @ 50 Ω Power – Generate: 1 mW @ 50 Ω 50 MHz 50 MHz 0.21 % 2.1 µW 432A w/478AH76, 3458A E44xX series Power – Measure9 (-10 to 20) dBm (-20 to -10) dBm (20 to 30) dBm (10 to 20) dBm (9 to 100) kHz (9 to 100) kHz 9 kHz to 20 GHz SWR < 1.2 (100 to 300) kHz SWR < 1.6:1 300 kHz to 1 MHz SWR < 1.2:1 1 MHz to 2 GHz SWR < 1.1:1 0.10 dB 0.26 dB 0.16 dB 0.14 dB 0.13 dB 0.13 dB Agilent E9304A- H19 w/ E4419B E9304A-H19 E9300A-H25 Agilent 8482A- H84 w/ E4419B
11--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2562.01) 06/24/2025 Page 11 of 22 Parameter/Range Frequency CMC2, 8, 11 (±) Comments Power – Measure9 (cont) (10 to 20) dBm (-20 to 10) dBm (10 to 20) dBm (100 to 300) kHz SWR < 1.6:1 300 kHz to 1 MHz SWR < 1.2:1 1 MHz to 2 GHz SWR < 1.1:1 (2 to 4.2) GHz SWR < 1.3:1 (100 to 300) kHz SWR < 1.6:1 300 kHz to 1 MHz SWR < 1.2:1 1 MHz to 2 GHz SWR < 1.1:1 (2 to 4.2) GHz SWR < 1.3:1 (50 to 100) MHz SWR < 1.15:1 (0.1 to 2) GHz SWR < 1.1:1 (2 to 12.4) GHz SWR < 1.15:1 (12.4 to 18) GHz SWR < 1.2:1 (18 to 26.5) GHz SWR < 1.25:1 (26.5 to 40) GHz SWR < 1.4:1 (40 to 50) GHz SWR < 1.5:1 0.14 dB 0.13 dB 0.13 dB 0.14 dB 0.057 dB 0.052 dB 0.054 dB 0.055 dB 0.15 dB 0.15 dB 0.15 dB 0.15 dB 0.16 dB 0.16 dB 0.2 dB Agilent 8482A- H84 w/ E4419B Agilent 8487A- H84 w/ E4419B Agilent 8487D w/ E4419B
10 to 20 dBm
12--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2562.01) 06/24/2025 Page 12 of 22 Parameter/Equipment Frequency CMC2, 8 (±) Comments Power – Measure9 (cont) (-60 to -20) dBm (50 to 100) MHz SWR < 1.15:1 (0.1 to 2) GHz SWR < 1.1:1 (2 to 12.4) GHz SWR < 1.15:1 (12.4 to 18) GHz SWR < 1.2:1 (18 to 26.5) GHz SWR < 1.25:1 (26.5 to 40) GHz SWR < 1.4:1 (40 to 50) GHz SWR < 1.5:1 (50 to 100) MHz SWR < 1.15:1 (0.1 to 2) GHz SWR < 1.1:1 (2 to 12.4) GHz SWR < 1.15:1 (12.4 to 18) GHz SWR < 1.2:1 (18 to 26.5) GHz SWR < 1.25:1 (26.5 to 40) GHz SWR < 1.4:1 (40 to 50) GHz SWR < 1.5:1 0.076 dB 0.077 dB 0.081 dB 0.082 dB 0.09 dB 0.11 dB 0.16 dB 0.18 dB 0.18 dB 0.19 dB 0.19 dB 0.19 dB 0.20 dB 0.23 dB Agilent 8487D w/ E4419B
-60 to -20 dBm
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2562.01) 06/24/2025 Page 13 of 22 Parameter/Range Frequency CMC2, 8, 11 (±) Comments Power – Measure 9 (cont) (-20 to 10) dBm (10 to 20) dBm SWR < 1.2:1 (-20 to 10) dBm SWR < 1.2:1 (-30 to -20) dBm SWR < 1.2:1 (50 to 67) GHz (0.01 to 2) GHz (2 to 26.5) GHz (26.5 to 50) GHz (50 to 67) GHz (0.01 to 2) GHz (2 to 26.5) GHz (26.5 to 50) GHz (50 to 67) GHz (0.01 to 2) GHz (2 to 26.5) GHz (26.5 to 50) GHz (50 to 67) GHz 0.23 dB 0.21 dB 0.21 dB 0.21 dB 0.21 dB 0.21 dB 0.21 dB 0.21 dB 0.21 dB 0.34 dB 0.34 dB 0.34 dB 0.34 dB KT-V8486A E4419B KT-N8488A E4419B Power – Generate (Includes DUT Mismatch 1.4 VSWR) (-10 to 20) dBm (-20 to -10) dBm (10 to 20) dBm (-20 to 10) dBm (10 to 20) dBm (9 to 100) kHz (9 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz 1 MHz to 2 GHz (2 to 4.2) GHz (100 to 300) kHz 300 kHz to 1 MHz 1 MHz to 2 GHz (2 to 4.2) GHz (50 to 100) MHz (0.1 to 2) GHz (2 to 12.4) GHz (12.4 to 18) GHz (18 to 26.5) GHz (26.5 to 40) GHz (40 to 50) GHz 0.10 dB 0.26 dB 0.14 dB 0.13 dB 0.21 dB 0.35 dB 0.05 dB 0.06 dB 0.18 dB 0.33 dB 0.22 dB 0.22 dB 0.35 dB 0.35 dB 0.44 dB 0.60 dB 0.61 dB Measure transfer 33250A, E4419B, E9304H19 33250A, E4419B, 8482A-H84 E8257D, E4419B, 8482A-H84 E8257D, E4419B, 8487A-H84
14--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2562.01) 06/24/2025 Page 14 of 22 Parameter/Range Frequency CMC2, 8, 11 (±) Comments Power – Generate (Includes DUT Mismatch 1.4 VSWR) (cont) (-20 to 10) dBm (-60 to -20) dBm (-20 to 10) dBm (50 to 100) MHz (0.1 to 2) GHz (2 to 12.4) GHz (12.4 to 18) GHz (18 to 26.5) GHz (26.5 to 40) GHz (40 to 50) GHz (50 to 100) MHz (0.1 to 2) GHz (2 to 12.4) GHz (12.4 to 18) GHz (18 to 26.5) GHz (26.5 to 40) GHz (40 to 50) GHz (50 to 67) GHz 0.18 dB 0.19 dB 0.33 dB 0.33 dB 0.43 dB 0.59 dB 0.60 dB 0.24 dB 0.24 dB 0.37 dB 0.37 dB 0.46 dB 0.61 dB 0.62 dB 0.23 dB + M E8257D, E4419B, 8487A-H84 E8257D, E4419B, 8487D-H84 M = Mismatch error E8257D, KT-E8361A V8486A Power Generate – (-20 to 10) dBm Ratio Steps: (-1 to -11) dB (-10 to -50) dB (-50 to -110) dB 50 MHz 0.054 dB + R 0.012 dB + 0.000 31 dB/dB + R 0.011 dB + 0.000 62 dB/dB + R 0.015 dB + 0.000 98 dB/dB + R Substitution/transfer using CMC measurement to set initial reference on UUT as limited by R Characterized step attenuators. Note: CMC shown at 50 MHz Type N, other frequency & connectors will be greater magnitude
-20 to 10 dBm
15--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2562.01) 06/24/2025 Page 15 of 22 Parameter/Range Frequency CMC2, 8, 11 (±) Comments Network Analyzer Dynamic Accuracy Test – dB Steps Network Analyzer Calibration Comparison 3.5 mm Rho 0.999 Rho 0.001 5 dBm Change (0 to 5) dB (-1 to -10) dB (-11 to -19) dB (-21 to -30) dB (-31 to -40) dB (-41 to -50) dB (-51 to -60) dB 10 MHz (0.125 to 2) GHz (2.125 to 8) GHz (8.125 to 20) GHz (20.125 to 26.5) GHz 10 MHz (0.125 to 2) GHz (2.125 to 8) GHz (8.125 to 20) GHz (20.125 to 26.5) GHz 0.002 lin (0.0012 to 0.0014) lin (0.0011 to 0.000 78) lin (0.000 69 to 0.000 095) lin (0.000 091 to 0.000 71) lin (0.000 75 to 0.0011) lin (0.0011 to 0.0015) lin (0.0015 to 0.0018) lin 0.0060 lin 0.0045 lin 0.0061 lin (0.012 + 6.7 × 10 -6 f) lin (0.015 - 5.6 × 10-6 f) lin 0.000 99 lin 0.000 90 lin 0.0011 lin (0.0019 + 2.9 × 10 -6 f) lin (0.0025 + 4.5 × 10-6 f) lin KT 8482A 4419B Two CW signals offset & phase locked (in dB steps) E8361A w/ data- based SOL cal kit f = frequency in GHz Phase Noise for Analyzers – (Offset Frequency) 10 Hz 100 Hz 1 kHz 10 kHz 30 kHz 100 kHz 1000 kHz 3000 kHz 6000 kHz 9990 kHz 1 GHz 2.6 dB @ 89 dbc/Hz 2.6 dB @ 115 dbc/Hz 1.3 dB @ 135 dbc/Hz 1.0 dB @ 147 dbc/Hz 1.0 dB @ 149 dbc/Hz 1.0 dB @ 151 dbc/Hz 1.0 dB @ 160 dbc/Hz 1.0 dB @ 160 dbc/Hz 1.0 dB @ 165 dbc/Hz 1.0 dB @ 167 dbc/Hz Low noise oscillator
to 5 dB
16--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2562.01) 06/24/2025 Page 16 of 22 Parameter/Equipment Frequency CMC2, 8 (±) Comments Phase Noise for Signal Sources – (Offset Frequency) ≤ 100 kHz ≤ 100 kHz ≤ 1 MHz Carrier: ≤ 100 MHz 0.1 GHz < f ≤ 26.5GHz 50 kHz < f ≤ 26.5 GHz 2.3 dB 2.3 dB 2.3 dB (LREF - LDUT) ≥ 10dB, f = frequency E5500A Cal Factor & Effective Efficiency 6 @ 50 Ω – Nominal 1 µW, 1 mW (-30 to +5) dBm (0.009 to 0.05) MHz (0.1 to 4200) MHz (4.2 to 12.4) GHz (12.4 to 15) GHz (15 to 26) GHz (26 to 40) GHz (40 to 50) GHz 1.2 % cal factor 1.2 % cal factor 1.4 % cal factor 1.5 % cal factor 2.5 % cal factor 2.7 % cal factor 2.7 % cal factor RF power transfer & DC substitution Parameter/Equipment Range CMC2, 8 (±) Comments S-Parameters – S 11(22) Measure – @ 50 Ω 2.4 mm: 45 MHz to 2 GHz (2 to 20) GHz (0.3 to 1) lin (0.03 to 0.3) lin (0.01 to 0.03) lin (0.3 to 1) lin (0.01 to 0.3) lin (0.3 to 1) lin (0.03 to 0.3) lin (0.01 to 0.03) lin (0.3 to 1) lin (0.01 to 0.3) lin (0.019 to 0.028) lin (0.017 to 0.018) lin 0.017 lin (3.5 to 1.6)° (180 to 3.5)° (0.023 to 0.034) lin (0.018 to 0.023) lin 0.018 lin (5 to 2)° (180 to 5)° E8361A, 85056A
to 100000 kHz
17

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2562.01) 06/24/2025 Page 17 of 22 Parameter/Equipment Range CMC2, 8 (±) Comments S-Parameters – (cont) S 11(22) Measure – @ 50 Ω 2.4 mm: (20 to 40) GHz (40 to 50) GHz S 12(21) Measure – 2.4 mm: 45 MHz to 50 GHz S 11(22) Measure – @ 50 Ω 3.5 mm: 45 MHz to 2 GHz (2 to 20) GHz (0.3 to 1) lin (0.01 to 0.3) lin (0.3 to 1) lin (0.03 to 0.3) lin (0.01 to 0.03) lin (0.3 to 1) lin (0.01 to 0.3) lin (0.3 to 1) lin (0.03 to 0.3) lin (0.01 to 0.03) lin (0.3 to 1) lin (0.01 to 0.3) lin (0 to -60) dB (0.3 to 1) lin (0.03 to 0.3) lin (0.01 to 0.03) lin (0.3 to 1) lin (0.01 to 0.3) lin (0.3 to 1) lin (0.03 to 0.3) lin (0.01 to 0.03) lin (0.3 to 1) lin (0.01 to 0.3) lin (5 to 2)° (180 to 5)° (0.037 to 0.056) lin (0.03 to 0.037) lin 0.03 lin (9 to 3.2)° (180 to 9)° (0.044 to 0.07) lin (0.034 to 0.044) lin 0.034 lin (11 to 4)° (180 to 11)° (0.08 to 0.6) dB (0.5 to 5.8)° (0.01 to 0.022) lin (0.009 to 0.01) lin 0.009 lin (2 to 1.3)° (54 to 2)° (0.012 to 0.015) lin (0.008 to 0.013) lin 0.008 lin (2.6 to 0.82)° (0.0045 to 2.6)° E8361A, 85056A E8361A, 85056A E8361A, 85052C
18

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2562.01) 06/24/2025 Page 18 of 22 Parameter/Equipment Range CMC2, 8 (±) Comments S-Parameters – (cont) S 11(22) Measure – @ 50 Ω 3.5 mm: (20 to 26) GHz S 12(21) Measure – 3.5 mm: 45 MHz to 26 GHz S11(22) Measure – @ 50 Ω 7 mm, Type N6: 1 MHz to 2 GHz (2 to 18) GHz S 12(21) Measure – 7 mm, Type N6: 1 MHz to 18 GHz (0.3 to 1) lin (0.03 to 0.3) lin (0.01 to 0.03) lin (0.3 to 1) lin (0.01 to 0.3) lin (0 to -60) dB (0.01 to 1) lin (0.3 to 1) lin (0.03 to 0.3) lin (0.01 to 0.03) lin (0.01 to 1) lin (0.3 to 1) lin (0.03 to 0.3) lin (0.01 to 0.03) lin (0 to -60) dB (0.013 to 0.017) lin (0.008 to 0.014) lin 0.009 lin (2.8 to 1)° (53 to 2.8)° (0.05 to 0.27) dB (0.3 to 1.9)° (0.003 to 0.01) lin (1 to 0.6)° (6 to 1)° (16 to 6)° (0.002 to 0.007) lin (1.6 to 0.4)° (5 to 1.6)° (11 to 5)° (0.05 to 0.27) dB (0.3 to 1.9)° E8361A, 85052C E8361A, 85050C
19--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2562.01) 06/24/2025 Page 19 of 22 Parameter/Equipment Range CMC2, 8, 11 (±) Comments S-Parameters – (cont) S 11(22) Measure – @ 50 Ω 1.85 mm: (1 to 67) GHz (0.1 to 1) lin (0.001 to 0.1) lin (0 to -60) dB (0.0089 to 0.027) lin (0.65 to 180)° (0.0089 to 0.020) lin (5.1 to 180)° (0.09 to 0.37) dB (0.45 to 4.5)° E8361A, 85050C E8361A, 85058B RF Power – Measure Relative Level Insertion Loss 100 kHz to 50 GHz 100 kHz to 50 GHz 0.013 dB + 0.004 dB/10 dB 0.026 dB + 0.004 dB/10 dB E4448A/233 Amplitude Modulation – Measure 200 MHz to 3 GHz 0.010 kHz to 50 GHz (30 to 90) % ratio; 1 kHz Rate 5 % ratio; 50 Hz to 5 kHz Rate 30 % ratio; 50 Hz to 5 kHz Rate 99 % ratio; 50 Hz to 5 kHz Rate 5 % ratio; (5 to 100) kHz Rate 30 % ratio; (5 to 100) kHz Rate 99 % ratio; (5 to 100) kHz Rate 0.43 % AM 2.4 % AM 1.2 % AM 0.42 % AM 2.4 % AM 0.88 % AM 0.32 % AM E4448A/233
1 to 67 GHz
20--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2562.01) 06/24/2025 Page 20 of 22 Parameter/Equipment Range CMC2, 8, 11 (±) Comments Angular (Frequency) Modulation – Measure 200 MHz to 20 GHz (100 to 240) kHz Peak Deviation Modulation Index > 1 0.80 kHz AT-E4448A AT-33250A AT-34401A rubidium oscillator Angular (Phase) Modulation – Measure 200 MHz to 20 GHz (1 to 10) Radian Modulation Index 0.78 % + 0.0025 radian AT-E4448A rubidium oscillator Angular & Amplitude Modulation (Digital Signal) – Measure 16 QAM 256 QAM 64 QAM, B PSK QPSK (0.5 to 44) GHz 0.83 % EVM AT 89441A EVM=error vector magnitude III. Time & Frequency Parameter/Range Range CMC 2, 14 (±) Comments Frequency – Measure 5, 10 MHz 1 Hz to 120 MHz 250 kHz to 50 GHz 2.5 pHz/Hz 10 pHz/Hz 10 nHz/Hz + 0.10 Hz NIST FMAS, GPS receiver (1 Hz Steps) E4448A/233 ext lock Frequency – Measuring Equipment 10 MHz Distribution 1 Hz to 10 MHz 10 pHz/Hz 2.3 µHz/Hz Rubidium, 58503B distribution amplifiers AT 33250 waveform generator
200000000 to 20000000000 Hz
21--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2562.01) 06/24/2025 Page 21 of 22 Parameter/Range Range CMC2, 14 (±) Comments Frequency – Measuring Equipment (cont) 250 kHz to 67 GHz 10 nHz/Hz + 1.2 mHz E8257D-550 ext lock Time Interval – Measuring Equipment & Measure 1 ns to 10 s 0.92 ns + TI0.04 μs/s 33250A/ 53132A/12 TI = Time interval in seconds __________________________________________ 1 This laboratory does not normally offer commercial calibration services. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Agilent 3458A with Option 2, settings DCV, 100PLC, ACAL within prior 24 Hrs, 1 year cal cycle. 4 Transfer using Agilent 3458A. 5 Agilent 3458A four wire ohms, ACAL within prior 24 Hrs, NPLC 100 < 100E6 Ohm > NPLC 10 6 Calibration Factor 100 kHz to 10 MHz is effective efficiency only. 7 Measure and Generate is limited to below 5 kHz; Measure only above 5 kHz. 8 The stated measured values are determined usi ng the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percentage or fraction of the reading plus a fixed floor specification. 9 The statement of CMC does not include the effects of mismatch error. 10 Add (12 μV/V) * (Vinput / 1000)2 for voltage > 100 V unless used as a characterized transfer. 11 In the statement of CMC, the value is defined as the percentage of reading unless otherwise noted, and R is the resolution contribution from the unit under test. 12 Points identified in the Parameter/Range reflect the reference standard range for which the CMC applies. 13 The 5790A/3 may be used to characterize the 5720A/3 and 5725A to generate CMC values. 14 The type of instrument or material being calibra ted is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
250000 to 67000000000 Hz
22

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2562.01) 06/24/2025 Page 22 of 22 15 This scope meets A2LA’s P112 Flexible Scope Policy.
23ISO/IEC 17025:2017; ANSI/NCSL Z540.3-2006--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

15385 Oxnard Street, Van Nuys, CA, 91411, US

34.18662, -118.44867

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.