What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 3 scope lines.
A2LA certificate 1446.01 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1446.01) 07/17/2024 Page 1 of 2
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
UNLIMITED SERVICES, INC.
1321 Cedar Street
Port Huron, MI 48060
Wayne Mattise Phone: 586 727 8890
CALIBRATION
Valid To: August 31, 2026 Certificate Number: 1446.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with A2LA’s Calibration Program Requirements) , accreditation is granted
to this laboratory to perform the following calibrations
1, 4:
I. Dimensional
Parameter/Equipment
Range
CMC2 (±)
Comments
Optical Comparators &
Measuring Machines
3 –
Length of Travel
Magnification
Table Squareness
Angularity
Up to 6 in
Up to 8 in
Up to 12 in
10x to 100x
3 in
(0 to 180)°
0.000 20 in
0.000 24 in
0.000 32 in
0.038 % of Magnification
0.000 19 in
1.1 arc min
Glass master scales
Glass grid
Glass grid
Angle & gage blocks
_____________________________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration. | 0 to 180 ° |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1446.01) 07/17/2024 Page 2 of 2
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 3 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.