Weed Instrument Co., Inc. DBA Curtiss-Wright
707 Jeffrey Way, 78665-0300, Round Rock, TX, United States
Visit website- Scope lines
- 4
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 4 scope lines.
A2LA certificate 2931.01 · 4 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2931.01) 12/31/2025 Page 1 of 3
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
WEED INSTRUMENT CO., INC. DBA
CURTISS-WRIGHT
707 Jeffrey Way
Round Rock, TX 78680
Jacob Sanchez Phone: 512 839 6418
CALIBRATION
Valid To: December 31, 2027 Certificate Number: 2931.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations1, 3:
I. Thermodynamics
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Temperature, RTD’s –
Measuring Equipment
Liquid Nitrogen
Fluke 7380
Ice Bath
Fluke 6020
Fluke 6050
Fluke 9173
-196 °C (LN2)
(-80 to 0) °C
(0 to 100) °C
100 °C
0 °C
(50 to 100) °C
(100 to 200) °C
(200 to 300) °C
(300 to 400) °C
(400 to 550) °C
100 °C
(100 to 425) °C
(425 to 660) °C
0.20 °C
0.020 °C
0.028 °C
0.030 °C
0.014 °C
0.017 °C
0.023 °C
0.022 °C
0.027 °C
0.039 °C
0.030 °C
0.085 °C
0.13 °C
SPRT
Keysight DAQ973A
Keysight 34420A | ||
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2931.01) 12/31/2025 Page 2 of 3
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Temperature,
Thermocouple –
Measuring Equipment
Type B Thermocouple
Type C Thermocouple
Type E Thermocouple
Type J Thermocouple
Type K Thermocouple
Type N Thermocouple
Type R Thermocouple
Type S Thermocouple
(538 to 1093) °C
(1093 to 1427) °C
(1427 to 1450) °C
0 °C
(38 to 538) °C
(538 to 1093) °C
(1093 to 1427) °C
(1427 to 1450) °C
-79 °C
0 °C
(38 to 538) °C
(538 to 871) °C
-79 °C
0 °C
(38 to 538) °C
(538 to 871) °C
-79 °C
0 °C
(38 to 538) °C
(538 to 1093) °C
(1093 to 1260) °C
-79 °C
0 °C
(38 to 538) °C
(538 to 1093) °C
(1093 to 1260) °C
0 °C
(38 to 538) °C
(538 to 1093) °C
(1093 to 1427) °C
(1427 to 1450) °C
0 °C
(38 to 538) °C
(538 to 1093) °C
(1093 to 1427) °C
(1427 to 1450) °C
0.4 °C
1.6 °C
1.7 °C
0.3 °C
0.6 °C
0.8 °C
1.8 °C
1.9 °C
0.3 °C
0.3 °C
0.6 °C
0.7 °C
0.3 °C
0.3 °C
0.6 °C
0.7 °C
0.3 °C
0.3 °C
0.6 °C
0.8 °C
1.4 °C
0.3 °C
0.3 °C
0.6 °C
0.8 °C
1.4 °C
0.4 °C
0.5 °C
0.5 °C
1.6 °C
1.7 °C
0.4 °C
0.6 °C
0.5 °C
1.6 °C
1.7 °C
Type S or R secondary
standard thermocouple
and NI PXIE 4353
thermocouple module
Ak20a TC calibrator | to 1450 °C |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2931.01) 12/31/2025 Page 3 of 3
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Temperature,
Thermocouple –
Measuring Equipment
(Cont)
Secondary Standard
Type S Thermocouple
Type T Thermocouple
(38 to 538) °C
(538 to 1093) °C
(1093 to 1427) °C
(1427 to 1450) °C
-79 °C
0 °C
(38 to 400) °C
0.4 °C
0.4 °C
1.6 °C
1.7 °C
0.3 °C
0.3 °C
0.6 °C
Type R primary
standard thermocouple
and NI PXIE 4353
thermocouple module
___________________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainties (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 This scope meets A2LA’s P112 Flexible Scope Policy.
4 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
WEED INSTRUMENT CO., INC. DBA
CURTISS-WRIGHT
Round Rock, TX
for technical competence in the field of
Calibration
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General
requirements for the competence of testing and calibration laboratories. This laboratory also meets the requirements of R205 –
Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for
a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 31st day of December 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 2931.01
Valid to December 31, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.