Yokogawa Corporation of America
2 Dart Road, 30265, Newnan, GA, United States
Visit website- Scope lines
- 10
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 10 scope lines.
A2LA certificate 3474.01 · 10 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 1050 V |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3474.01) 01/05/2026 Page 2 of 9
Parameter/Equipment
Range
CMC2, 3, 4 (±)
Comments
DC Current – Measure
Up to 199.990 000 µA
(>0.199 99 to 1.999 900 00) mA
(>1.9999 to 19.999 000 0) mA
(>19.999 to 199.990 000) mA
(>0.199 99 to 1.999 900 00) A
(1.9999 to 20) A
14 µA/A + 1.5 µA
18 µA/A + 1.5 µA
48 µA/A + 1.5 µA
88 µA/A + 3.6 µA
340 µA/A + 32 µA
530 µA/A + 0.46 mA
Fluke 8508A
Resistance – Generate
Up to 11 Ω
(11 to 33) Ω
(33 to 110) Ω
(110 to 330) Ω
(0.33 to 1.1) kΩ
(1.1 to 3.3) kΩ
(3.3 to 11) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
(110 to 330) kΩ
(0.33 to 1.1) MΩ
(1.1 to 3.3) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
(330 to 1100) MΩ
31 μΩ/Ω + 7.6 mΩ
23 μΩ/Ω + 11 mΩ
22 μΩ/Ω + 11 mΩ
22 μΩ/Ω + 15 mΩ
22 μΩ/Ω + 15 mΩ
22 μΩ/Ω + 150 mΩ
22 μΩ/Ω + 76 mΩ
22 μΩ/Ω + 760 mΩ
22 μΩ/Ω + 760 mΩ
25 μΩ/Ω + 7.6 Ω
25 μΩ/Ω + 7.6 Ω
46 μΩ/Ω + 120 Ω
0.010 % + 190 Ω
0.020 % + 1.9 kΩ
0.039 % + 2.2 kΩ
0.23 % + 75 kΩ
1.2 % + 380 kΩ
Fluke 5522A
Resistance – Measure
Up to 2 Ω
Up to 20 Ω
Up to 200 Ω
Up to 2 kΩ
Up to 20 kΩ
Up to 200 kΩ
Up to 2 MΩ
Up to 20 MΩ
Up to 200 MΩ
Up to 2 GΩ
0.51 % + 54 µΩ
7.5 µΩ /Ω + 5.9 µΩ
7.6 µΩ /Ω + 0.15 mΩ
7.6 µΩ /Ω + 1.5 mΩ
7.6 µΩ /Ω + 15 mΩ
43 µΩ /Ω + 0.15 Ω
9.6 µΩ /Ω + 1.1 Ω
22 µΩ /Ω + 91 Ω
0.013 % + 9.1 kΩ
0.14 % + 910 kΩ
Fluke 8508A
Oscilloscopes –
Level Sine Amp
50 Ω
Level Sine Flatness
Relative to 50 kHz
Reference
4.4 mV to 5.560 V
p-p
0.1 Hz to 550 MHz
550 MHz to 1.16 GHz
(1.16 to 2.5) GHz
(2.5 to 3.2) GHz
2.1 %
5.0 % flatness
6.0 % flatness
5.5 % flatness
5.5 % flatness
Fluke 9500B
0.2 Hz to 550
MHz
5V
3V
2V | to 20 A |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3474.01) 01/05/2026 Page 3 of 9
Parameter/Equipment
Range
CMC2, 3, 4 (±)
Comments
Oscilloscopes –
(cont)
Square Wave Amp
DC Signal Level
Edge Transition Time
Time Marker Output
Frequency
2 mV to 200 V
p-p
2 mV to 5 Vp-p
±1 mV to ±200 V
±1 mV to ±5 V
10 Hz to 2 MHz
(0.5 to 10) ns
(10 to 40) Hz
40 Hz to 11.999 kHz
12 kHz to 10 MHz
0.18 %
0.18 %
0.086 %
0.097 %
210 ps
0.20 %
73 µHz/Hz + 240 µHz
53 µHz/Hz + 47 mHz
12 µHz/Hz + 340 mHz
Fluke 9500B
Into 1 MΩ load
Into 50 Ω load
(10 Hz)
Into 1 MΩ load
Into 50 Ω load
Fluke 9500B
Electrical Calibration of
Thermocouple Indicating
Systems3–
Type E
Type J
Type K
Type T
(250 to 1000) °C
(210 to 1200) °C
(200 to 1372) °C
(250 to 400) °C
0.45 °C
0.27 °C
0.37 °C
0.56 °C
Fluke 5522A
DC Power – Generate
33 mV to 1020 V
(0.33 to 329.99) mA
(0.33 to 2.9999) A
(3 to 20.5) A
0.18 mW/W + 1.8 µW
0.17 mW/W + 25 µW
0.54 mW/W + 85 µW
Fluke 5522A
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Voltage – Generate
(1.0 to 33) mV
(10 to 45) Hz
45 Hz to 10 kHz
0.061 % + 4.6 µV
0.012 % + 4.6 µV
Fluke 5522A | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3474.01) 01/05/2026 Page 4 of 9
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Voltage – Generate (cont)
(1.0 to 33) mV
(33 to 330) mV
(0.33 to 3.3) V
(3.3 to 33) V
(33 to 330) V
(330 to 1020) V
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.015 % + 4.6 µV
0.077 % + 4.6 µV
0.27 % + 9.1 µV
0.023 % + 38 µV
0.011 % + 6.1 µV
0.012 % + 6.1 µV
0.027 % + 6.1 µV
0.061 % + 24 µV
0.023 % + 38 µV
0.015 % + 46 µV
0.015 % + 46 µV
0.023 % + 38 µV
0.054 % + 95 µV
0.18 % + 0.46 mV
0.023 % + 0.50 mV
0.012 % + 0.46 mV
0.018 % + 0.46 mV
0.027 % + 0.46 mV
0.069 % + 1.2 mV
0.015 % + 1.5 mV
0.015 % + 4.6 mV
0.019 % + 4.6 mV
0.023 % + 4.6 mV
0.15 % + 38 mV
0.023 % + 7.9 µV
0.019 % + 7.9 µV
0.023 % + 7.8 µV
Fluke 5522A
AC Voltage – Measure
Up to 199.990 000 mV
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
0.012 % + 5.3 µV
0.010 % + 3.9 µV
0.010 % + 1.9 µV
0.013 % + 3.8 µV
0.030 % + 7.6 µV
0.066 % + 18 µV
Fluke 8508A | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3474.01) 01/05/2026 Page 5 of 9
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Voltage – Measure (cont)
(>0.1999 to 1.999 900 00) V
(>1.9999 to 19.999 000 0) V
(>19.999 to 199.990 000) V
(>199.99 to 1050) V
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
40 Hz to 5 kHz
0.010 % + 19 µV
0.0084 % + 19 µV
0.0069 % + 19 µV
0.010 % + 19 µV
0.020 % + 38 µV
0.050 % + 180 µV
0.23 % + 1.8 mV
0.77 % + 18 mV
0.010 % + 0.19 mV
84 µV/V + 0.19 mV
68 µV/V + 0.19 mV
0.010 % + 0.19 mV
0.020 % + 0.38 mV
0.05 % + 1.8 mV
0.0084 % + 1.9 mV
0.041 % + 1.9 mV
0.010 % + 2.0 mV
0.020 % + 3.9 mV
0.05 % + 18 mV
0.011 % + 20 mV
Fluke 8508A
AC Current – Generate
(29 to 329.9999) µA
(0.33 to 3.299 999) mA
(3.3 to 32.999 99) mA
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
0.019 mA/A + 0.076 µA
0.012 mA/A + 0.076 µA
9.6 µA/A + 0.076 µA
0.023 mA/A + 0.11 µA
0.061 mA/A + 0.15 µA
0.12 mA/A + 0.3 µA
20 µA/A + 0.16 µA
11 µA/A + 0.11 µA
8.3 µA/A + 0.11 µA
16 µA/A + 0.15 µA
38 µA/A + 0.23 µA
77 µA/A + 0.46 µA
31 µA/A + 1.6 µA
8.4 µA/A + 1.5 µA
5.2 µA/A + 1.5 µA
7.5 µA/A + 0.15 µA
16 µA/A + 2.3 µA
31 µA/A + 3.0 µA
Fluke 5522A | ||
| 6 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3474.01) 01/05/2026 Page 6 of 9
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Current – Generate
(cont)
(33 to 329.9999) mA
(0.33 to 1.1) A
(1.1 to 3) A
(3 to 11) A
(11 to 20.5) A
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
30 µA/A + 16 µA
8.6 µA/A + 15 µA
1.6 µA/A + 15 µA
8.2 µA/A + 38 µA
16 µA/A + 76 µA
31 µA/A + 150 µA
27 µA/A + 77 µA
3.8 µA/A + 76 µA
46 µA/A + 760 µA
46 µA/A + 760 µA
11 µA/A + 0.083 mA
4.6 µA/A + 0.076 mA
46 µA/A + 0.76 mA
190 µA/A + 3.8 mA
4.7 µA/A + 1.5 mA
7.8 µA/A + 1.5 mA
230 µA/A + 1.5 mA
10 µA/A + 3.8 mA
12 µA/A + 3.8 mA
230 µA/A + 3.8 mA
Fluke 5522A
AC Current – Measure
Up to 199.9900 µA
(>0.199 99 to 1.999 900) mA
(>1.9999 to 19.999 00) mA
(>19.999 to 199.9900) mA
(>0.1999 to 1.999 900) A
(>1.999 900 to 20) A
10 Hz to 10 kHz
(10 to 30) kHz
10 Hz to 10 kHz
(10 to 30) kHz
10 Hz to 10 kHz
(10 to 30) kHz
10 Hz to 10kHz
(10 to 30) kHz
10 Hz to 2 kHz
(2 to 10) kHz
10 Hz to 2 kHz
(2 to 10) kHz
0.048 % + 18 µA
0.061 % + 18 µA
0.028 % + 18 µA
0.061 % + 18 µA
0.028 % + 18 µA
0.061 % + 18 µA
0.028 % + 18 µA
0.057 % + 18 µA
0.066 % + 19 µA
0.23 % + 19 µA
0.070 % + 66 µA
0.19 % + 63 µA
Fluke 8508A | to 0.00019999 A |
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3474.01) 01/05/2026 Page 7 of 9
Parameter/Range
Frequency
CMC2, 3, 4 (±)
Comments
Capacitance – Generate
(0.19 to 1.0999) nF
(1.10 to 3.2999) nF
(3.3 to 329.999) nF
(.33 to 1.099 99) µF
(1.1 to 3.299 99) µF
(3.3 to 10.9999) µF
(11 to 32.9999) µF
(33 to 109.999) µF
(110 to 329.999) µF
(0.33 to 1.099 99) mF
(1.1 to 3.2999) mF
(3.3 to 10.9999) mF
(11 to 32.9999) mF
10 Hz to 10 kHz
(10 to 3000) Hz
(10 to 1000) Hz
(10 to 600) Hz
(10 to 300) Hz
(10 to 150) Hz
(10 to 120) Hz
(10 to 80) Hz
(0 to 50) Hz
(0 to 20) Hz
(0 to 6) Hz
(0 to 2) Hz
(0 to 0.6) Hz
1.1 %
0.55 %
0.23 %
0.23 %
0.23 %
0.24 %
0.32 %
0.41 %
0.35 %
0.35 %
0.35 %
0.35 %
0.64 %
Fluke 5522A
Phase – Generate
(0 to ± 179.99)°
45 Hz to 10 kHz
0.12°
Fluke 5522A
Parameter/Equipment
Range
CMC2, 3(±)
Comments
AC Power – Generate, PF = 1,
(45 to 65) Hz
(33 to 330) mV
330 mV to 1020 V
(3.3 to 9) mA
(9 to 33) mA
(33 to 90) mA
(90 to 330) mA
(0.33 to 0.9) A
(0.9 to 2.2) A
(2.2 to 4.5) A
(4.5 to 20) A
(3.3 to 9) mA
(9 to 33) mA
(33 to 90) mA
1.1 mW/W + 2.8 nW
0.77 mW/W + 1.8 nW
1.1 mW/W + 33 nW
0.77 mW/W + 14 nW
0.99 mW/W + 0.33 µW
0.84 mW/W + 0.27 µW
0.92 mW/W + 0.12 µW
0.61 mW/W + 0.08 µW
0.92 mW/W + 0.12 µW
0.61 mW/W + 0.08 µW
0.92 mW/W + 0.72 µW
Fluke 5522A | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3474.01) 01/05/2026 Page 8 of 9
Parameter/Equipment
Range
CMC2, 3(±)
Comments
AC Power – Generate, PF
= 1, (45 to 65) Hz (cont)
330 mV to 1020 V
(90 to 330) mA
(0.33 to 0.9) A
(0.9 to 2.2) A
(2.2 to 4.5) A
(4.5 to 20) A
0.61 mW/W + 0.51 µW
0.84 mW/W + 5.7 µW
0.69 mW/W + 4.4 µW
0.18 mW/W + 1.8 µW
0.17 mW/W + 25 µW
Fluke 5522A
II. Mechanical
Parameter/Equipment Range CMC
2, 4, 5 (±) Comments
Pressure – Measuring
Equipment
(0.2 to 25) psi
(1.7 to 100) psi
(1 to 1000) psi
(1000 to 10 000) psi
0.000 62 % + 0.54 mpsi
0.000 49 % + 0.50 mpsi
0.0019 % + 0.23 mpsi
0.0055 % + 0.48 psi
Ruska 2465-725
Ruska 2465-727
Ruska 2465-729
Fluke PPCH-G
A70M
III. Time & Frequency
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Frequency – Measuring
Equipment
(10 to 40) Hz
40 Hz to 11.999 kHz
12 kHz to 10 MHz
73 µHz/Hz + 240 µHz
53 µHz/Hz + 47 mHz
12 µHz/Hz + 340 mHz
Fluke 9500B
_______________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration. | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3474.01) 01/05/2026 Page 9 of 9
3 The stated measured values are determined usi ng the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a
fraction/percentage of the reading plus a fixed floor specification.
4 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated.
5 The type of instrument or material being calib rated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
6 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 10 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Applied Technical ServicesMarietta, GA · ~72 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Technical Maintenance, Inc. - PEACHTREE CORNERSPeachtree Corners, GA · ~85 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Trescal, Inc. - Atlanta, GAAlpharetta, GA · ~90 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Hottinger Bruel & KjaerDuluth, GA · ~92 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Quality Tech ServicesByron, GA · ~126 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.