Laboratorio di prova - ALSTOM Sesto San Giovanni - Divisione: Certification & Validation
Via Fosse Ardeatine 120, 20099, Sesto San Giovanni, Italy
- Accredited standards
- 8
- ACCREDIA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 8 standard numbers and the 8 official names we hold. When no standard matches, it searches the method text of every scope line.
CISPR 16-2-1Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements
EN 50121-3-2Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus
EN 50155Railway applications - Rolling stock - Electronic equipment
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heatSome clauses
Limits written next to it
Par 13.4.5 - Prova al calore secco/Dry heat test - solo/only EN 60068-2-2:2007
IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity testRange limit
Limits written next to it
Prove di immunità/Immunity tests - solo/only EN 61000-4-4 (±2 kV
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
Limits written next to it
Prove di immunità/Immunity tests - solo/only EN 61000-4-5 (1,2 / 50 µs
CEI EN 55016-2-1:2015/A1:2018/AC:2022; EN 55016-2-1:2014/A1:2017/AC:2020; EN 61000-4-5:2014; EN 61000-4-5:2014/A1:2017; IEC 61000-4-5:2014; IEC 61000-4-5:2014/AMD1:2017; EN 61000-4-4:2012; IEC 61000-4-4:2012; EN 60068-2-1:2007; IEC 60068-2-1:2007; EN 60068-2-2:2007; IEC 60068-2-2:2007; EN IEC 60068-2-14:2023; IEC 60068-2-14:2023; CEI EN 50121-3-2:2017; CEI EN 50121-3-2:2017/A1:2019; EN 50121-3-2:2016; EN 50121-3-2:2016/A1:2019; CEI EN 50155:2022; EN 50155:2021; EN 60068-2-1:2007; EN 60068-2-2:2007
Read from the scope as published by ACCREDIA. Register refreshed 2026-11-20.
Scope as published by ACCREDIA
2 lines
ISO/IEC 17025
Active01129
Accredited scope, certificate 01129
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | CEI EN 55016-2-1:2015/A1:2018/AC:2022; EN 55016-2-1:2014/A1:2017/AC:2020; EN 61000-4-5:2014; EN 61000-4-5:2014/A1:2017; IEC 61000-4-5:2014; IEC 61000-4-5:2014/AMD1:2017; EN 61000-4-4:2012; IEC 61000-4-4:2012; EN 60068-2-1:2007; IEC 60068-2-1:2007; EN 60068-2-2:2007; IEC 60068-2-2:2007; EN IEC 60068-2-14:2023; IEC 60068-2-14:2023; CEI EN 50121-3-2:2017; CEI EN 50121-3-2:2017/A1:2019; EN 50121-3-2:2016; EN 50121-3-2:2016/A1:2019; CEI EN 50155:2022; EN 50155:2021; EN 60068-2-1:2007; EN 60068-2-2:2007 | Apparecchiature elettriche ed elettroniche/Electric and electronic equipment; Apparecchiature elettriche, elettroniche e meccaniche, componenti e materiali/Electric, electronic and mechanical equipment, components and materials; Apparecchiature per applicazioni ferroviarie, tranviarie, filoviarie e metropolitane: materiale rotabile/Appliances for railway applications: Rolling stock - Apparatus; Equipaggiamenti elettronici utilizzati su materiale rotabile/Electronic equipment used on rolling stock | -40 to 125 °C |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. Laboratorio di prova - ALSTOM Sesto San Giovanni - Divisione:
Certification & Validation
UNI CEI EN ISO/IEC 17025:2018
Allegato al certificato di accreditamento n. 01129 rev. 4 del 23/01/2025
Via Fosse Ardeatine 120
20099 Sesto San Giovanni MI
Legenda/Note
Revisione: 17
Sede A
Data: 17/09/2025
pag. 2 di 2
Il simbolo (1), se presente, indica: "Materiale/Prodotto/Matrice" non previsto dal metodo ma assimilabile/The symbol (1), if present, means: Material/Product/Matrix not
provided for by the method but acceptable
Per la definizione della “categoria" di prova indicata nel titolo, si veda il Regolamento Generale ACCREDIA RG-02/For the definition of the test “category” indicated in the title,
see ACCREDIA General Regulation RG-02.
Il QRcode consente di accedere direttamente al sito www.accredia.it per verificare la validità dell'elenco prove e del certificato di accreditamento
rilasciato al laboratorio/The QRcode allows to directly access to the website www.accredia.it to verify the validity of the test list and of the
accreditation certificate issued to the laboratory.
L’eventuale simbolo “X” riportato nella colonna “O&I” indica che il laboratorio è accreditato anche per fornire opinioni e interpretazioni basate sui
risultati delle specifiche prove contrassegnate/Any "X" symbol in the "O&I" column indicates that the laboratory is also accredited to provide opinions
and interpretations based on the results of the specific marked tests.
L'eventuale simbolo (*) indica che è attiva una sospensione dell’accreditamento per la specifica attività riportata a fianco/Any symbol (*) indicates that
a suspension of accreditation is active for the specific activity shown next to it. | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the ACCREDIA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.