Q-Lab China
Room 206, Building D, No. 800 Pu Xing Rd., Shanghai, 201114, People's Republic of China, Shanghai, China
Visit website- Scope lines
- 3
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 3 scope lines.
A2LA certificate 2383.02 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2383.02) 12/23/2025 Page 1 of 2
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
Q-LAB CHINA
Room 206, Building D, No. 800 Pu Xing Rd
Shanghai, People’s Republic of China 201114
Kobe Qu Phone: 86 21 58797970
CALIBRATION
Valid To: November 30, 2027 Certificate Number: 2383.02
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations
1, 5:
I. Optical Radiation
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Irradiance and Radiometers
(0.001 to 2000) W/m2
@ (250 to 800) nm
6.5 %
For UV and visible light
sensors used in weathering
devices such as xenon arc
and fluorescent UV
Control Parameters in
Weathering Instruments
3 –
Temperature
Relative Humidity
Irradiance
(0 to 100) °C
(10 to 95) % RH
(0.001 to 2000) W/m2
@ (250 to 800) nm
1.7 °C
3.4 % RH
6.8 %
As used in artificial
weathering instruments
Digital thermometer
Rotronic hygropalm
Working radiometer
________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration. | 0.001 to 2000 W/m2 |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2383.02) 12/23/2025 Page 2 of 2
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMC, the value is defined as the percentage of reading, unless otherwise noted.
5 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
Q-LAB CHINA
Shanghai, PEOPLE’S REPUBLIC OF CHINA
for technical competence in the field of
Calibration
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories . This laboratory also meets R205 – Specific
Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a
defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 23rd of December 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 2383.02
Valid to November 30, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.