Registers refreshed 2026-11-20.See refresh dates
China

Shenzhen Huaxia Testing Technology Co.,

102A, 102B, Building 2, Shanghenglang New Industrial Zone, Shanghenglang Community, Dalang Street, Longhua District, shenzhen, 518000, People's Republic of China, shenzhen, China

Visit website
A2LA 4742.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
8
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 8 standard numbers and the 4 official names we hold. When no standard matches, it searches the method text of every scope line.

ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
ANSI C63.26
EN 18031-1
EN 18031-2
EN 18031-3
FCC PART 15Radio Frequency Devices
ICES-001Industrial, Scientific and Medical (ISM) Equipment
IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirements+1 national

National versions in the same scope

AS/NZS 62368.1national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.

Scope as published by A2LA

5 lines
A2LA

ISO/IEC 17025

Active

4742.01

The scope document we hold says it is valid until 2028-02-29.

View scope

Accredited scope, certificate 4742.01

LineMethodMatrixRange
1ISO/IEC 17025:2017; CFR 47, FCC Part 15 Subpart B (using ANSI C63.4:20142); CFR 47, FCC Part 18 (using FCC MP-5:1986); ICES-001; ICES-003; ICES-005; CFR 47, FCC Part 15 Subpart C (using ANSI C63.10:2020); CFR 47, FCC Part 15 Subpart E (using ANSI C63.10:2020 and FCC KDB 905462 D02 (v02), April 8, 2016); CFR 47, FCC Part 22, Part 24, Part 25, Part 27 (using ANSI C63.26:2015); RSS-GEN; RSS-132; RSS-133; RSS-139; RSS-210 (≤ 40 GHz); RSS-247; RSS-248; RSS-310; ANSI C63.26-2015; ANSI C63.10-2020+Cor. 1-2023+C63.10a-2024; IEEE/ANSI C95.1 (MPE calculation only); EN 62368-1; BS EN 62368-1; IEC 62368-1; UL 62368-1; AS/NZS 62368.1; J62368-1-See scope document
2IEC 62368-1--
3EN 18031-1; EN 18031-2; EN 18031-3; ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2020-to 40000 MHz
4FCC KDB 905462 D02 (v02), April 8, 2016; ANSI C63.26:2015-to 40000 MHz
5

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation. Accredited Laboratory A2LA has accredited SHENZHEN HUAXIA TESTING TECHNOLOGY CO., LTD Shenzhen, People’s Republic of China for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 20th day of January 2026. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 4742.01 Valid to February 29, 2028

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.