Advanced Technology Services - Caterpillar Technical Center
14009 Old Galena Rd, Tech Center TCL, 61523, Chillicothe, IL, United States
Visit website- Scope lines
- 22
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 22 scope lines.
A2LA certificate 1592.05 · 22 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017 | - | 0.01 to 100 % |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1592.05) Revised 11/03/2025 Page 2 of 21
II. Dimensional Testing/Calibration
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Surface Analysis6
Ra: Up to 260 mm
Ra: Up to 100 mm
2.2 µm
0.31 µm
Mahr LD-260
Zeiss Surfcom 2000
Differential
Transducers
6 (LVDT)
Up to 50.8 mm
(50.9 to 177.8) mm
(177.9 to 304.8) mm
0.17 µm/mm + 6.4 µm
0.069 %
0.061 %
Mitutoyo 197-201
micrometer head w/
Agilent 34410A
Starrett 656-7041 dial
indicator
Starrett 656-12041
dial indicator
Inside Diameter6
(54 to 79.5) mm
(78.5 to 156) mm
(152.5 to 308) mm
4.3 µm
5.7 µm
7.0 µm
Dial bore #4 gage
Dial bore #5 gage
Dial bore #6 gage
Length
6 – 1D
Up to 25.4 mm
Up to 127 mm
Up to 1000 mm
Up to 4000 mm
4.0 µm
0.17 mm
36 µm
0.14 mm
Digital indicator
Chatillon test stand
Mahr 817 CLM height
AACCM 8540-6
Length
6 – 2D
X-Axis: Up to 152.4 mm
Y-Axis: Up to 127 mm
X-Axis: Up to 180 mm
Y-Axis: Up to 127 mm
7.8 µm
7.9 µm
Dynascope microscope
Dynascope microscope
w/ multi lens
External Diameter
6
Up to 25 mm
(25 to 50) mm
(50 to 75) mm
(75 to 100) mm
(100 to 125) mm
(125 to 150) mm
(0.1 to 101.6) mm
2.4 µm
2.6 µm
3.1 µm
3.5 µm
5.2 µm
6.3 µm
3.1 µm
Mitutoyo micrometer
Starrett 733
micrometer
Laser micrometer | to 260 mm |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1592.05) Revised 11/03/2025 Page 3 of 21
III. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
DC Voltage – Generate
(0 to 220) mV
(0.22 to 2.2) V
(2.2 to 11) V
(11 to 22) V
(22 to 220) V
(220 to 1100) V
(1000 to 5000) V
8.9 µV/V + 0.40 µV
5.2 µV/V + 0.7 µV
3.8 µV/V + 2.5 µV
7.4 µV/V + 4.0 µV
5.2 µV/V + 40 µV
6.8 µV/V + 0.40 mV
1.7 mV/V + 2.6 V
Fluke 5730A
SRS-PS350
DC Voltage – Measure
(0 to 200) mV
(0.2 to 2) V
(2 to 20) V
(20 to 200) V
(200 to 1000) V
6.1 µV/V + 0.10 µV
3.7 µV/V + 0.40 µV
3.7 µV/V + 4.0 µV
5.7 µV/V + 40 µV
5.7 µV/V + 0.53 mV
Fluke 8508A
DC Current
– Generate
(0 to 220) µA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(0.22 to 2.2) A
(2.2 to 11) A
(11 to 20.5) A
(0 to 2) A
(2 to 20) A
(20 to 120) A
(120 to 2500) A
(100 to 1000) A
(1000 to 2000) A
45 µA/A + 6.0 nA
38 µA/A + 7.0 nA
38 µA/A + 40 nA
47 µA/A + 0.70 µA
95 µA/A + 12 µA
3.6 mA/A + 0.48 mA
1.3 mA/A + 0.75 mA
0.76 mA/A + 0.080 mA
0.057 mA/A + 0.80 mA
93 µA/A + 4.8 mA
2.1 mA/A + 0.84 A
0.42 A
0.85 A
Fluke 5730A
Fluke 5730A &
Fluke 5725A
Fluke 5522A
Fluke 52120A / coil
Current amplifier w/
transducers
DC Current – Measure
(10 to 200) µA
(0.2 to 2) mA
(2 to 20) mA
(20 to 200) mA
(0.2 to 2) A
(2 to 20) A
13 µA/A + 0.40 nA
15 µA/A + 4.0 nA
17 µA/A + 40 nA
57 µA/A + 0.80 µA
0.21 mA/A + 16 µA
0.45 mA/A + 0.40 mA
Fluke 8508A | ||
| 4 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1592.05) Revised 11/03/2025 Page 4 of 21
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Electrical Charge (In
Coulomb) – Measure
(0 to 200) nC
2.8 pC/nC + 0.5 nC
Keithley 6514
Capacitance – Generate
(0.4 to 1.0999) nF
(1.1 to 3.2999) nF
(3.3 to 10.9999) nF
(11 to 32.9999) nF
(33 to 109.999) nF
(110 to 329.999) nF
(0.33 to 1.099 99) µF
(1.1 to 3.2999) µF
(3.3 to 10.9999) µF
(11 to 32.9999) µF
(33 to 109.999) µF
(110 to 329.999) µF
(0.33 to 1.0999) mF
(1.1 to 3.2999) mF
(3.3 to 10.999) mF
(11 to 32.999) mF
(33 to 109.999) mF
14 pF/nF + 5.6 pF
6.1 pF/nF + 3.3 pF
2.5 pF/nF + 1.6 pF
1.5 pF/nF + 83 pF
2.7 pF/nF + 11 pF
4.7 pF/nF + 0.22 nF
2.6 nF/µF + 0.15 nF
4.9 nF/µF + 2.4 nF
3 nF/µF + 9 nF
6.9 nF/µF + 46 nF
5.3 nF/µF + 58 nF
6.6 nF/µF + 0.42 µF
4.9 nF/µF + 2.4 nF
6.8 µF/mF + 4.5 µF
5.3 µF/mF + 7.5 µF
9.9 µF/mF + 79 µF
16 µF/mF + 0.52 mF
Fluke 5522A
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Voltage – Generate
(0 to 2.2) mV
(2.2 to 22) mV
(22 to 220) mV
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
0.3 µV/mV + 5.0 µV
0.12 µV/mV + 5.0 µV
0.1 µV/mV + 5.0 µV
0.25 µV/mV + 5.0 µV
0.6 µV/mV + 6.0 µV
1.3 µV/mV + 12 µV
0.3 µV/mV + 5.0 µV
0.12 µV/mV + 5.0 µV
0.1 µV/mV + 5.0 µV
0.25 µV/mV + 5.0 µV
0.6 µV/mV + 6.0 µV
1.3 µV/mV + 12 µV
1.7 µV/mV + 25 µV
3.4 µV/mV + 25 µV
0.3 µV/mV + 15 µV
0.12 µV/mV + 8.0 µV
0.07 µV/mV + 8.0 µV
Fluke 5730A | 0 to 200 nC |
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1592.05) Revised 11/03/2025 Page 5 of 21
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Voltage – Generate
(cont)
(22 to 220) mV
(0.22 to 2.2) V
(2.2 to 22) V
(22 to 220) V
(220 to 1100) V
(220 to 750) V
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(15 to 50) kHz
(50 to 1) kHz
(30 to 50) kHz
(50 to 100) kHz
0.15 µV/mV + 8.0 µV
0.4 µV/mV + 20 µV
0.8 µV/mV + 25 µV
1.7 µV/mV + 30 µV
3.3 µV/mV + 60 µV
0.3 mV/V + 50 µV
0.11 mV/V + 20 µV
0.048 mV/V + 10 µV
0.08 mV/V + 12 µV
0.1 mV/V + 40 µV
0.4 mV/V + 100 µV
1.2 mV/V + 250 µV
2.0 mV/V + 400 µV
0.3 mV/V + 500 µV
0.11 mV/V + 200 µV
0.048 mV/V + 70 µV
0.08 mV/V + 120 µV
0.1 mV/V + 250 µV
0.4 mV/V + 800 µV
1.2 mV/V + 2.5 mV
2.0 mV/V + 4 mV
0.3 mV/V + 5 mV
0.11 mV/V + 2 mV
0.065 mV/V + 0.7 mV
0.1 mV/V + 1.2 mV
0.18 mV/V + 3 mV
1.1 mV/V + 20 mV
5.4 mV/V + 50 mV
10 mV/V + 100 mV
0.36 mV/V + 20 mV
0.085 mV/V + 4 mV
0.4 mV/V + 11 mV
0.016 V/V + 45 mV
Fluke 5730A
Fluke 5730A w/
5725A
AC Voltage – Measure
(0 to 200) mV
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
0.17 µV/mV + 14 µV
0.14 µV/mV + 4 µV
0.12 µV/mV + 4 µV
Fluke 8508A | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1592.05) Revised 11/03/2025 Page 6 of 21
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Voltage – Measure (cont)
(0 to 200) mV
(0.2 to 2) V
(2 to 20) V
(20 to 200) V
(200 to 1000) V
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
40 Hz to 10 kHz
(10 to 30) kHz
0.11 µV/mV + 2 µV
0.14 µV/mV + 4 µV
0.34 µV/mV + 8 µV
0.15 mV/V + 0.12 mV
0.12 mV/V + 0.02 mV
0.09 mV/V + 0.02 mV
0.075 mV/V + 0.02 mV
0.11 mV/V + 0.02 mV
0.22 mV/V + 0.04 mV
0.57 mV/V + 0.2 mV
10 mV/V + 20 mV
0.15 mV/V + 1.2 mV
0.12 mV/V + 0.2 mV
0.09 mV/V + 0.2 mV
0.075 mV/V + 0.2 mV
0.11 mV/V + 0.2 mV
0.22 mV/V + 2 mV
3 mV/V + 20 mV
10 mV/V + 200 mV
0.12 mV/V + 1.2 mV
0.12 mV/V + 0.2 mV
0.075 mV/V + 0.2 mV
0.11 mV/V + 2 mV
0.22 mV/V + 4 mV
0.57 mV/V + 20 mV
0.12 mV/V + 200 mV
0.23 mV/V + 400 mV
Fluke 8508A
AC Current – Generate
(9 to 220) µA
(0.22 to 2.2) mA
(10 to 20) Hz
(20 to 40) Hz
(40 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
(40 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
0.27 nA/µA + 2.4 nA
0.13 nA/µA + 89 nA
0.081 nA/µA + 7.3 nA
0.29 nA/µA + 2.6 nA
1.2 nA/µA + 11 nA
0.27 µA/mA + 19 µA
0.17 µA/mA + 21 nA
0.11 µA/mA + 12 nA
0.23 µA/mA + 52 nA
1.2 µA/mA + 0.27 µA
Fluke 8508A | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1592.05) Revised 11/03/2025 Page 7 of 21
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Current – Generate (cont)
(2.2 to 22) mA
(22 to 220) mA
(0.22 to 2.2) A
(0 to 2) A
(2 to 20) A
(20 to 120) A
120 A to 3 kA
120 A to 1 kA
(120 to 300) A
(0 to 100) A
(0 to 50) A
(10 to 20) Hz
(20 to 40) Hz
(40 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
(40 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(20 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(10 to 65) Hz
(65 to 300) Hz
300 Hz to 1 kHz
(1 to 3) kHz
(3 to 6) kHz
(6 to 10) kHz
(10 to 65) Hz
(65 to 300) Hz
300 Hz to 1 kHz
(1 to 3) kHz
(3 to 6) kHz
(6 to 10) kHz
10 to 65) Hz
(65 to 300) Hz
300 Hz to 1 kHz
(1 to 3) kHz
(3 to 6) kHz
(6 to 10) kHz
(10 to 65) Hz
(65 to 300) Hz
300 Hz to 1 kHz
(1 to 3) kHz
(3 to 6) kHz
(6 to 10) kHz
0.31 µA/mA + 0.67 µA
0.19 µA/mA + 0.42 µA
0.17 µA/mA + 0.015 µA
0.23 µA/mA + 0.51 µA
1.2 µA/mA + 2.7 µA
0.29 µA/mA + 2.3 µA
0.17 µA/mA + 0.15 µA
0.12 µA/mA + 0.075 µA
6.6 nA/mA + 2.1 µA
1.2 µA/mA + 0.027 mA
0.13 mA/A + 7.3 µA
0.47 mA/A + 0.24 mA
3.6 mA/A + 0.63 mA
5.9 mA/A + 9.3 mA
0.014 mA/A + 1.1 mA
0.081 mA/A + 1.1 mA
5.9 mA/A + 9.3 mA
1.2 mA/A + 25 mA
1.6 mA/A + 62 mA
0.025 mA/A + 9.4 mA
0.032 mA/A + 9.4 mA
0.081 mA/A + 9.4 mA
0.23 mA/A + 31 mA
0.78 mA/A + 62 mA
2.3 mA/A + 94 mA
0.028 mA/A + 19 mA
0.033 mA/A + 28 mA
0.082 mA/A + 94 mA
0.23 mA/A + 0.23 A
0.78 mA/A + 0.42 A
3.1 mA/A + 0.70 A
1.4 mA/A + 0.84 A
1.4 mA/A + 0.84 A
0.71 mA/A + 0.84 A
1.6 mA/A + 1.2 A
1.7 mA/A + 1.2 A
2.6 mA/A + 1.2 A
Fluke 5730A
Fluke 52120A /
coil
Fluke 52120A w/
25/50 turn coil
Fluke 52120A w/
25 turn coil | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1592.05) Revised 11/03/2025 Page 8 of 21
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Current – Measure
(0 to 200) µA
(0.1 to 2.0) mA
(2.0 to 20) mA
(20 to 200) mA
(0.2 to 2.0) A
(2.0 to 20) A
10 Hz to 10 kHz
10 Hz to 10 kHz
10 Hz to 10 kHz
10 Hz to 5 kHz
10 Hz to 2 kHz
(2 to 10) kHz
10 Hz to 2 kHz
(2 to 10) kHz
0.5 nA/ µA + 22 nA
0.31 µA/mA + 20 µA
0.71 µA/mA + 10 µA
0.29 µA/mA + 10 µA
0.062 mA/A + 0.20 mA
0.074 mA/A + 0.20 mA
0.82 mA/A + 2.0 mA
2.5 mA/A + 2.0 mA
Fluke 8508A
Oscilloscopes –
DC Signal:
50 Ω Load
1 MΩ Load
Amplitude Square Wave:
50 Ω, 10 Hz to 10 kHz
1 MΩ:
10 Hz to 1 kHz
(1 to 10) kHz
Leveled Sine Wave
(Into 50 Ω Load) @
50kHz Reference
Flatness @ 50 kHz
Reference
Time Markers
(50 Ω Load)
(-6.6 to 6.6) V
(-130 to 130) V
± 1 mV to 6.6 V (p-p)
± 1 mV to 130 V (p-p)
± 1 mV to 130 V (p-p)
± 5 mV to 5.5 V (p-p)
± 5 mV to 5.5 V (p-p)
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
± 5 mV to 3.5 V (p-p)
(600 to 1100) MHz
5 s to 50 ms
20 ms to 2 ns
39 mV/V + 40 µV
0.94 mV/V + 40 µV
51 mV/V + 40 µV
0.92 mV/V + 40 µV
2.2 mV/V + 40 µV
0.37 V/V + 0.10 mV
0.35 V/V + 0.10 mV
0.44 V/V + 0.10 mV
0.83 V/V + 0.10 mV
1.1 V/V + 0.10 mV
(58 + 1000t) µs/s
5.7 µs/s
Fluke 5522A
t = time in seconds | ||
| 9 | - | OilShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1592.05) Revised 11/03/2025 Page 9 of 21
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Resistance – Generate
Fixed Points
0.1 Ω
25 Ω
65 Ω
100 Ω
260 Ω
400 Ω
0 Ω
1 Ω
1.9 Ω
10 Ω
19 Ω
100 Ω
190 Ω
1 kΩ
1.9 kΩ
10 kΩ
19 kΩ
100 kΩ
190 kΩ
1 MΩ
1.9 MΩ
10 MΩ
19 MΩ
100 MΩ
330 MΩ
1.1 GΩ
14 µΩ/Ω
6.1 µΩ/Ω
5.4 µΩ/Ω
5.8 µΩ/Ω
4.9 µΩ/Ω
4.3 µΩ/Ω
46 µΩ
0.10 mΩ
0.18 mΩ
0.25 mΩ
0.49 mΩ
1.1 mΩ
2.1 mΩ
6.9 mΩ
13 mΩ
0.068 Ω
0.13 Ω
0.88 Ω
1.7 Ω
14 Ω
35 Ω
0.42 kΩ
0.94 kΩ
12 kΩ
3.1 MΩ
17 MΩ
Leeds & Northrup
standard resistor
w/ oil bath
Fluke 5730A
Fluke 5522A
Resistance – Measure
(0 to 2) Ω
(2 to 20) Ω
(20 to 200) Ω
(0.2 to 2.0) kΩ
(2.0 to 20) kΩ
(20 to 200) kΩ
(0.2 to 2.0) MΩ
(2 to 20) MΩ
(20 to 200) MΩ
(0.2 to 2) GΩ
22 µΩ/Ω + 4.0 µΩ
12 µΩ/Ω + 14 µΩ
9.6 µΩ/Ω + 50 µΩ
9.5 µΩ/Ω + 0.5 mΩ
9.4 µΩ/Ω + 5.0 mΩ
9.6 µΩ/Ω + 50 mΩ
11 µΩ/Ω + 1.0 Ω
30 µΩ/Ω + 0.10 kΩ
0.20 mΩ/Ω + 10 kΩ
1.8 mΩ/Ω + 1 M
Ω
Fluke 8508A | See scope document |
| 10 | - | Air; FuelShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1592.05) Revised 11/03/2025 Page 10 of 21
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Simulation of
Thermocouple Indicators
& Indicating Systems
Type E
Type J
Type K
Type T
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.50 °C
0.16 °C
0.14 °C
0.16 °C
0.21 °C
0.27 °C
0.16 °C
0.14 °C
0.17 °C
0.23 °C
0.33 °C
0.18 °C
0.16 °C
0.26 °C
0.40 °C
0.63 °C
0.24 °C
0.16 °C
0.14 °C
Fluke 5522A
IV. Fluid Quantities
Parameter/Equipment
Range
CMC
2, 4, 8 (±)
Comments
Mass Fuel Flow –
Measuring Equipment
(10 to 15 000) g/min
0.41 % + 0.59 g/min
Gravimetric
calibrator
(g = gram)
Mass Air Flow –
Measuring Equipment
(20 to 40 000) kg/h
(1.3 to 5500) kg/h
0.49 %
0.33 %
Subsonic nozzles,
critical flow
Venturis | See scope document |
| 11 | FTI Omnitrak OT-400 flow calibration system (gravimetric method); Verification w/ standard weights; Morehouse model-L Deadweight machine; Comparison w/ standard load cell | Water; Oil | See scope document |
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1592.05) Revised 11/03/2025 Page 12 of 21
Parameter/Equipment
Range
CMC2, 4, 8 (±)
Comments
Pressure
– Measuring
Equipment (cont)
Pneumatic (Absolute
Pressure)
(6 to 62.2) kPa
(>62.2 to 206.9) kPa
(104 to 2064.7) kPa
(>2064.7 to 6890.3) kPa
0.12 Pa/kPa + 2 Pa
0.14 Pa/kPa + 12 Pa
0.13 Pa/kPa + 40 Pa
0.14 Pa/kPa + 8.6 Pa
Fluke PPC4™
pressure controller/
calibrator
Rotational Speed, Non-
Contact
(50 to 5000) RPM
0.30 RPM
Phototach & Fluke
PM6680B
Torque – Measuring
Equipment
(1 to 8605.9) Nꞏm
(0 to 2370) Nꞏm
(0 to 5924) Nꞏm
(0 to 11 848) Nꞏm
(0 to 23 696) Nꞏm
(0 to 59 241) Nꞏm
0.019 % + 0.021 Nꞏm
3.5 Nꞏm
8.8 Nꞏm
18 Nꞏm
35 Nꞏm
88 Nꞏm
Lever arm w/ NIST
class F weights
Standard load cells
w/ dynamometer
Torque Wrenches
(4.5 to 23) Nꞏm
(27 to 136) Nꞏm
(163 to 814) Nꞏm
0.14 Nꞏm
1.7 Nꞏm
2.8 Nꞏm
Precision torque
transducers
Torque – Shafts
(0 to 169) Nꞏm
(0 to 338) Nꞏm
(0 to 847) Nꞏm
(0 to 1694) Nꞏm
(0 to 3390) Nꞏm
(0 to 8474) Nꞏm
(0 to 16 948) Nꞏm
(0 to 33 895) Nꞏm
(0 to 84 739) Nꞏm
0.26 Nꞏm
0.49 Nꞏm
1.2 Nꞏm
2.5 Nꞏm
5.6 Nꞏm
17 Nꞏm
28 Nꞏm
57 Nꞏm
0.13 kNꞏm
Torque shaft cal
bench w/ arm
VI. Thermodynamics
Parameter/Equipment
Range
CMC
2, 8 (±)
Comments
Temperature, RTD –
Measuring Equipment
(0 to 99) °C
(100 to 150) °C
0.07 °C
0.05 °C
SPRT & temperature
bath | ||
| 13 | - | Mechanical Components & PartsShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1592.05) Revised 11/03/2025 Page 13 of 21
Parameter/Equipment
Range
CMC2, 8 (±)
Comments
Dew Point – Measuring
Equipment
(0 to 25) °C
0.20 °C
Thunder Scientific
1200
Relative Humidity –
Measuring Equipment
(10 to 95) % RH
0.83 % RH
Thunder Scientific
1200
VII. Time & Frequency
Parameter/Equipment
Range
CMC
2, 8 (±)
Comments
Frequency – Measuring
Equipment
1 µHz to 80 MHz
2.3 x 10
-6 Hz/Hz
Agilent 33250A
Frequency – Measure
10 Hz to 225 MHz
5.8 x 10-6 Hz/Hz
Fluke PM6680B
Mechanical Testing
Parameter
Range Technique / Method
Force Testing – Mechanical
Components & Parts
Tangential Tension
Compression & Tension
(89 to 445) N
(0 to 4.5) N
(4.5 to 900) N
(900 to 4450) N
C-K Engineering tangential tension
machine
Chatillon TCD-1100 w/ load cell
Mass Measurement –
Mechanical Components &
Parts
(0 to 5200) g
(0 to 60) kg
Sartorious scale
Digi Matex scale
_____________________________________________ | See scope document |
| 14 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1592.05) Revised 11/03/2025 Page 14 of 21
SATELLITE
ADVANCED TECHNOLOGY SERVICES – CATERPILLAR TECHNICAL CENTER
AC 6132 Dock 29 Rench Rd Route 29
Mossville, IL 61552
Brady Van Hoorebeke Phone: 309 494 5123
CALIBRATION
I. Dimensional
Parameter Range CMC
2, 8 (±)
Comments
Linear Displacement,
Travel – Measuring
Equipment
Up to 500 mm
0.055 mm
Gage blocks
III. Thermodynamics
Parameter Range CMC
2, 8 (±)
Comments
Temperature – Measuring
Equipment
(-80 to 300) °C
0.27 °C
Class B RTD w/
Fluke 1586A
Humidity – Measuring
Equipment
(20 to 80) % RH
3.6 % RH
Omega IBTHX-SD
_____________________________________________ | to 500 mm |
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1592.05) Revised 11/03/2025 Page 15 of 21
SATELLITE
ADVANCED TECHNOLOGY SERVICES - CATERPILLAR PROVING GROUNDS
Peoria Proving Ground, 27194 Caterpillar Lane
Washington, IL 61571
Brady Van Hoorebeke Phone: 309 494 5123
CALIBRATION
I. Acoustical Quantities
Parameter/Range
Frequency
CMC
2, 8 (±)
Comments
Acoustic Level – Sound
Pressure Level Measuring
Equipment
94 dB re 2 x 10
-5 Pa
(31.5 to 125) Hz
(250 to 500) Hz
1 kHz
2 kHz
4 kHz
8 kHz
12.5 kHz
16 kHz
0.63 dB
0.49 dB
0.32 dB
0.56 dB
0.64 dB
0.82 dB
1.8 dB
1.9 dB
B&K 4226
multifunction
acoustic calibrator &
B&K 4231 sound
level source
II. Dimensional
Parameter/Equipment
Range
CMC
2, 7, 8 (±)
Comments
Linear Displacement,
Travel – Measuring
Equipment
(0 to 2032) mm
(2033 to 7620) mm
(5 + 0.16L) µm
(15 + 0.23L) µm
Heidenhain linear
encoder LS106
Angle – Measuring
Equipment
(0 to 60)°
0.16°
Gage blocks w/ sine
bar | ||
| 16 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1592.05) Revised 11/03/2025 Page 16 of 21
III. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
DC Voltage – Generate
(0 to 330) mV
(0 to 3.3) V
(3.3 to 33) V
(30 to 330) V
(100 to 1020) V
0.06 µV/mV + 3 µV
0.05 mV/V + 5 µV
0.05 mV/V + 50 µV
0.055 mV/V + 500 µV
0.055 mV/V + 1500 µV
Fluke 5502A
DC Voltage – Measure
(0 to 100) mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
(0 to 100) mV
100 mV to 1 V
(1 to 10) V
(10 to 80) V
90 µV/V + 4.2 µV
47 µV/V + 8.4 µV
36 µV/V + 60 µV
49 µV/V + 0.72 mV
56 µV/V + 10 mV
67 µV/V + 4 µV
210 µV/V + 8.1 µV
200 µV/V + 58 µV
610 µV/V + 1 mV
Agilent 34410A
Somat cal
stand/Keithley 2750
DC Current
– Generate
(0 to 330) µA
(330 to 3.3) mA
(3.3 to 33) mA
(33 to 330) mA
(0 to 1.1) A
(1.1 to 3) A
(0 to 11) A
(11 to 20.5) A
(100 to 3000) A
0.15 nA/µA + 0.02 µA
0.13 µA/mA + 0.05 µA
0.1 µA/mA + 0.25 µA
0.1 µA/mA + 2.5 µA
0.38 mA/A + 44 µA
0.38 mA/A + 44 µA
0.6 mA/A + 500 µA
1.0 mA/A + 750 µA
0.015 A
Fluke 5502A
Current amplifier
w/transducers
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Voltage – Generate
(1.0 to 33) mV
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
1.5 µV/mV + 20 µV
33 µV/mV + 20 µV
66 µV/mV + 20 µV
66 µV/mV + 20 µV
120 µV/mV + 33 µV
330 µV/mV + 60 µV
Fluke 5502A | ||
| 17 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1592.05) Revised 11/03/2025 Page 17 of 21
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Voltage – Generate
(cont)
(33 to 330) mV
(0.33 to 3.3) V
(3.3 to 33) V
(33 to 329) V
(330 to 1020) V
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
0.5 µV/mV + 20 µV
0.3 µV/mV + 20 µV
0.7 µV/mV + 20 µV
1 µV/mV + 40 µV
2.3 µV/mV + 170 µV
5 µV/mV + 330 µV
0.5 mV/V + 60 µV
0.3 mV/V + 60 µV
0.7 mV/V + 60 µV
1.0 mV/V + 60 µV
2.3 mV/V + 200 µV
5 mV/V + 900 µV
0.5 mV/V + 800 µV
0.3 mV/V + 600 µV
0.7 mV/V + 600 µV
1.0 mV/V + 600 µV
2.3 mV/V + 2000 µV
0.5 mV/V + 3.0 mV
0.8 mV/V + 9.0 mV
0.9 mV/V + 9.0 mV
1.2 mV/V + 9.0 mV
2.4 mV/V + 80 mV
0.5 mV/V + 20 mV
0.8 mV/V + 20 mV
0.9 mV/V + 20 mV
Fluke 5502A
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Resistance – Generate
(0 to 11) Ω
(11 to 33) Ω
(33 to 110) Ω
(110 to 330) Ω
(0.330 to 1.1) kΩ
(1.1 to 3.3) kΩ
(3.3 to 11) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
0.12 mΩ/Ω + 0.01 Ω
0.12 mΩ/Ω + 0.015 Ω
0.09 mΩ/Ω + 0.015 Ω
0.09 mΩ/Ω + 0.02 Ω
0.09 mΩ/Ω + 0.02 Ω
0.09 mΩ/Ω + 0.2 Ω
0.09 mΩ/Ω + 0.1 Ω
0.09 mΩ/Ω + 1 Ω
0.11 mΩ/Ω + 1 Ω
Fluke 5502A | ||
| 18 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1592.05) Revised 11/03/2025 Page 18 of 21
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Resistance – Generate
(cont)
(110 to 330) kΩ
(0.330 to 1.1) MΩ
(1.1 to 3.3) MΩ
(3.3 to 11) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
(330 to 1100) MΩ
0.12 mΩ/Ω + 10 Ω
0.15 Ω/Ω + 10 Ω
0.15 Ω/Ω + 150 Ω
0.6 Ω/Ω + 250 Ω
0.1 Ω/Ω + 2.5 kΩ
0.5 Ω/Ω + 3 kΩ
1.5 Ω/Ω + 5 MΩ
Fluke 5502A
Resistance – Measure
(0 to 100) Ω
100 Ω to 1 kΩ
(1 to 10) kΩ
(10 to 100) kΩ
100 kΩ to 1 MΩ
(1 to 10) MΩ
100 Ω to 100 kΩ
100 kΩ to 1 MΩ
0.15 mΩ/Ω + 4.8 mΩ
0.12 mΩ/Ω + 12 mΩ
0.12 mΩ/Ω + 12 mΩ
0.12 mΩ/Ω + 1.2 Ω
0.14 mΩ/Ω + 12 Ω
0.49 mΩ/Ω + 0.12 kΩ
1.4 mΩ/Ω + 1.4 Ω
1.9 mΩ/Ω + 1.4 Ω
Agilent 34410A
Somat cal
stand/Keithley 2750
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Current – Generate
(29 to 330) µA
(0.33 to 3.3) mA
(3.3 to 33) mA
(33 to 330) mA
(10 to 20) Hz
(20 to 45) Hz
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
2.0 nA/µA + 0.1 µA
1.5 nA/µA + 0.1 µA
1.3 nA/µA + 0.1µA
3.0 nA/µA + 0.15 µA
8.0 nA/µA + 0.2 µA
16 nA/µA + 0.4 µA
2.0 µA/mA + 0.15 µA
1.3 µA/mA + 0.15 µA
1.0 µA/mA + 0.15 µA
2.0 µA/mA + 0.2 µA
5.0 µA/mA + 0.3 µA
10 µA/mA + 0.6 µA
1.8 µA/mA + 2 µA
0.9 µA/mA + 2 µA
0.4 µA/mA + 2 µA
0.8 µA/mA + 2 µA
2.0 µA/mA + 3 µA
4.0 µA/mA + 4 µA
1.8 µA/mA + 20 µA
0.9 µA/mA + 20 µA
Fluke 5502A | ||
| 19 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1592.05) Revised 11/03/2025 Page 19 of 21
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Current – Generate
(cont)
(33 to 330) mA
(0.33 to 1.1) A
(1.1 to 3) A
(3 to 11) A
(11 to 20.5) A
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
(100 to 1000) Hz
(1 to 5) kHz
(45 to 100) Hz
(100 to 1000) Hz
(1 to 5) kHz
0.4 µA/mA + 20 µA
1.0 µA/mA + 50 µA
2.0 µA/mA + 100 µA
4.0 µA/mA + 200 µA
1.8 mA/A + 100 µA
0.5 mA/A + 100 µA
6.0 mA/A + 1000 µA
25 mA/A + 5000 µA
1.8 mA/A + 100 µA
0.6 mA/A + 100 µA
6.0 mA/A + 1000 µA
25 mA/A + 5000 µA
0.6 mA/A + 2000 µA
1.0 mA/A + 2000 µA
30 mA/A + 2000 µA
1.2 mA/A + 5000 µA
1.5 mA/A + 5000 µA
30 mA/A + 5000 µA
Fluke 5502A
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Simulation of
Thermocouple Indicators
& Indicating Systems
Type E
Type J
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
0.50 °C
0.16 °C
0.14 °C
0.16 °C
0.21 °C
0.27 °C
0.16 °C
0.14 °C
0.17 °C
0.23 °C
Fluke 5502A | ||
| 20 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1592.05) Revised 11/03/2025 Page 20 of 21
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Simulation of
Thermocouple Indicators
& Indicating Systems
(cont)
Type K
Type T
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.33 °C
0.18 °C
0.16 °C
0.26 °C
0.40 °C
0.63 °C
0.24 °C
0.16 °C
0.14 °C
Fluke 5502A
IV. Mechanical
Parameter/Equipment
Range
CMC
2, 8 (±)
Comments
Force – Measuring
Equipment
Up to 966 N
(0 to 2224.1) N
(0 to 8896.4) N
(0 to 22 241.1) N
(0 to 1200) kN
0.22 N
6.7 N
29 N
68 N
2 kN
NIST Class F
weights
ATS press & load
cells
Instron press &
load cells
Torque – Shafts
(0 to 10 000) Nꞏm
22 Nꞏm + 0.0021 Nꞏm/(Nꞏm)
Drive shaft
calibrator
Pressure – Measuring
Equipment
Hydraulic (Relative
Pressure)
Pneumatic (Absolute
Pressure)
0 kPa to 12 MPa
(12 to 40) MPa
(40 to 42) MPa
(42 to 140) MPa
(6 to 689.8) kPa
(689.8 to 6894.8) kPa
6.3 kPa
8.9 kPa
7.6 kPa
32 kPa
0.12 kPa
1.2 kPa
Fluke PPCH
DH Instruments
PPC3 | ||
| 21 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1592.05) Revised 11/03/2025 Page 21 of 21
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Vibration - Accelerometers
(10 to 99) Hz
100 Hz
(101 to 920) Hz
(921 to 5000) Hz
5001 Hz to 10 kHz
(10 to 15) kHz
(15 to 20) kHz
2.2 %
1.9 %
2.0 %
2.4 %
2.8 %
4.5 %
5.4 %
Modal Shop 9155C
V. Time & Frequency
Parameter/Equipment
Range
CMC2, 8 (±)
Comments
Frequency – Measuring
Equipment
100 Hz to 100 kHz
310 µHz/Hz
Somat Cal
Stand/Keithley 2750
____________________________________________
1 This laboratory is not available for commercial service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 This scope meets A2LA’s P112 Flexible Scope Policy.
4 In the statement of CMC, a percent refers to a percent of reading unless otherwise noted.
5 The measurands stated are generated using the indi cated instrument (see Commen ts). This capability is
suitable for the calibration of the devices intended to measure the measurand in the ranges indicated.
CMC’s are expressed as either a specific value that cove rs the full range or as a fraction/percentage of
the reading plus a fixed floor specification.
6 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for
the types of dimensional tests listed above and is considered equivalent to that of a calibration.
7 In the statement of CMC, L is the numerical value of the nominal length of the device measured in
millimeters.
8 The type of instrument or material being calib rated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 22 | ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Cloud TENFenton, MO · ~277 kmA2LAShares 1 accredited materialOil
- Clark Testing ServicesBuchanan, MI · ~281 kmA2LAShares 1 accredited materialOil
- SGS North AmericaGrass Lake, MI · ~463 kmA2LAShares 1 accredited materialOil
- ALS OIL & LUBRICANTS (TRIBOLOGY)Kansas City, KS · ~480 kmA2LAShares 1 accredited materialOil
- ALS OIL & LUBRICANTS (TRIBOLOGY)Valley View, OH · ~662 kmA2LAShares 1 accredited materialOil
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.