Registers refreshed 2026-11-08.See refresh dates
Germany

bioplan Institut für angewandte Biologie und Landschaftsplanung Gesellschaft mit beschränkter Haftung

Strandstraße 32 a, 18211, Ostseebad Nienhagen, Germany

DAKKS D-PL-19140-01-00ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
68
DAKKS certificate
1
Site in our directory
1
DAKKS accredited scope

What this lab is accredited for

Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 68 standard numbers and the 38 official names we hold. When no standard matches, it searches the method text of every scope line.

DIN26
DIN 38402-A 11
DIN 38402-A 12
DIN 38402-A 13
DIN 38404-C3
DIN 38404-C 6
DIN 38405-D1
DIN 38405-D4
DIN 38405-D5
DIN 38405-D7
DIN 38405-D9
DIN 38405-D13
DIN 38405-D24
Show all 26
DIN 38405-D27
DIN 38405-D29
DIN 38406-E5
DIN 38409-H2
DIN 38409-H16
DIN 38409-H41
DIN 38409-H44
DIN 38409-H 7
DIN 38410-M1
DIN 38412-L16
DIN 38412-L30
DIN 38412-L33
DIN 38415-T3
DIN 38415-T6
ISO26
ISO 5667-6Water quality - Sampling - Part 6: Guidance on sampling of rivers and streams
ISO 5814Water quality - Determination of dissolved oxygen - Electrochemical probe method
ISO 6878Water quality - Determination of phosphorus - Ammonium molybdate spectrometric method
ISO 7027Water quality - Determination of turbidity
ISO 7027-1Water quality - Determination of turbidity - Part 1: Quantitative methods
ISO 7887Water quality - Examination and determination of colour
ISO 9562Water quality - Determination of adsorbable organically bound halogens (AOX)
ISO 10523Water quality - Determination of pH
ISO 11348-1Water quality - Determination of the inhibitory effect of water samples on the light emission of Vibrio fischeri (Luminescent bacteria test) - Part 1: Method using freshly prepared bacteria
ISO 11348-2Water quality - Determination of the inhibitory effect of water samples on the light emission of Vibrio fischeri (Luminescent bacteria test) - Part 2: Method using liquid-dried bacteria
ISO 11732Water quality - Determination of ammonium nitrogen - Method by flow analysis (CFA and FIA) and spectrometric detection
ISO 11905-1Water quality - Determination of nitrogen - Part 1: Method using oxidative digestion with peroxodisulfate
Show all 26
ISO 13395Water quality - Determination of nitrite nitrogen and nitrate nitrogen and the sum of both by flow analysis (CFA and FIA) and spectrometric detection
ISO 14402Water quality - Determination of phenol index by flow analysis (FIA and CFA)
ISO 14403-1Water quality - Determination of total cyanide and free cyanide using flow analysis (FIA and CFA) - Part 1: Method using flow injection analysis (FIA)
ISO 14403-2Water quality - Determination of total cyanide and free cyanide using flow analysis (FIA and CFA) - Part 2: Method using continuous flow analysis (CFA)
ISO 14911Water quality - Determination of dissolved Li+, Na+, NH4+, K+, Mn2+, Ca2+, Mg2+, Sr2+ and Ba2+ using ion chromatography - Method for water and waste water
ISO 15088Water quality - Determination of the acute toxicity of waste water to zebrafish eggs (Danio rerio)
ISO 15681-1Water quality - Determination of orthophosphate and total phosphorus contents by flow analysis (FIA and CFA) - Part 1: Method by flow injection analysis (FIA)
ISO 15681-2Water quality - Determination of orthophosphate and total phosphorus contents by flow analysis (FIA and CFA) - Part 2: Method by continuous flow analysis (CFA)
ISO 15682Water quality - Determination of chloride by flow analysis (CFA and FIA) and photometric or potentiometric detection
ISO 15705Water quality - Determination of the chemical oxygen demand index (ST-COD) - Small-scale sealed-tube method
ISO 15923-1Water quality - Determination of selected parameters by discrete analysis systems - Part 1: Ammonium, nitrate, nitrite, chloride, orthophosphate, sulfate and silicate with photometric detection
ISO 17289Water quality - Determination of dissolved oxygen - Optical sensor method
ISO 18412Water quality - Determination of chromium(VI) - Photometric method for weakly contaminated water
ISO 23913Water quality - Determination of chromium(VI) - Method using flow analysis (FIA and CFA) and spectrometric detection
EN11
EN 872Water quality - Determination of suspended solids - Method by filtration through glass fibre filters
EN 1484Water analysis - Guidelines for the determination of total organic carbon (TOC) and dissolved organic carbon (DOC)
EN 1622Water quality - Determination of the threshold odour number (TON) and threshold flavour number (TFN)
EN 1899-1Water quality - Determination of biochemical oxygen demand after n days (BODn) - Part 1: Dilution and seeding method with allylthiourea addition (ISO 5815:1989, modified)
EN 1899-2Water quality - Determination of biochemical oxygen demand after n days (BODn) - Part 2: Method for undiluted samples
EN 12260Water quality - Determination of nitrogen - Determination of bound nitrogen (TNb), following oxidation to nitrogen oxides
EN 16695
EN 25813Water quality - Determination of dissolved oxygen - Iodometric method
EN 25814
EN 26777Water quality - Determination of nitrite - Molecular absorption spectrometric method
EN 27888Water quality - Determination of electrical conductivity
ISO 10304 series3
ISO 10304-1Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 1: Determination of bromide, chloride, fluoride, nitrate, nitrite, phosphate and sulfate
ISO 10304-3Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 3: Determination of chromate, iodide, sulfite, thiocyanate and thiosulfate
ISO 10304-4Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 4: Determination of chlorate, chloride and chlorite in water with low contamination
Other standards2
38402-A 30
38404-C 4

Read from the scope as published by DAKKS. Register refreshed 2026-11-06.

Scope as published by DAKKS

8 lines
DAKKS

ISO/IEC 17025

Active

D-PL-19140-01-00

View scope

Accredited scope, certificate D-PL-19140-01-00

LineMethodMatrixRange
1DIN EN ISO/IEC 17025:2018; DIN EN ISO 9001Wasser (Abwasser, Oberflächenwasser und Grundwasser)-
2DIN 38402-A 12; DIN 38402-A 30; DIN EN ISO 7887; DIN EN ISO 7027; DIN 38404-C 4; DIN EN ISO 10523; DIN EN 27888; DIN 38405-D 9; DIN EN 26777Wasser (Abwasser, Oberflächenwasser und Grundwasser)-
3DIN EN ISO 6878; DIN 38406-E 5; DIN EN ISO 5814; DIN EN 25814; DIN 38409-H 7; DIN ISO 15705; DIN 38412-L 16; DIN 38412-L 30; DIN EN ISO 11348-2; DIN EN 16695Water-
4DIN 38415-T 6; DIN EN ISO 15088; LCK 138; LCK 304; LCK 339; LCK 341; LCK 349; LCK 349S; DIN 38402-A 11; DIN EN ISO 5667-6; DIN 38402-A 13; DIN 38402-A 12; DIN 38402-A 30; DIN 38404-C 4; DIN EN ISO 10523Waste waterSee scope document
5DIN EN 27888: 1993-11; DIN EN 1622: 2006-10; DIN EN ISO 7887: 2012-04; DIN EN ISO 7027: 2000-04; DIN EN ISO 5814: 2013-03; DIN ISO 17289: 2014-12; DIN EN 25813: 1993-01; DIN 38404-C 6: 1984-05; DIN 38404-C 3: 2005-07; DIN EN ISO 11732: 2005-05; DIN 38406-E 5: 1983-10; DIN EN ISO 14911: 1999-12; DIN ISO 15923-1: 2014-07; DIN EN 26777: 1993-04; DIN EN ISO 10304-1: 2009-07; DIN EN ISO 13395: 1996-12; DIN 38405-D 9: 2011-09; DIN 38405-D 29: 1994-11Effluent-
6DIN EN ISO 6878; DIN EN ISO 15681-1; DIN EN ISO 15681-2; DIN EN ISO 10304-1; DIN ISO 15923-1; DIN 38405-D 4-1; DIN EN ISO 15682; DIN EN ISO 10304-4; DIN 38405-D 1-1 und D 1-2; DIN 38405-D 1-3 und D 1-4; DIN 38405-D 5-1; DIN 38405 D 5-2; DIN 38405-D 13-2; DIN EN ISO 14403-1; DIN EN ISO 14403-2; DIN 38405-D 7; DIN 38405-D 13-1Effluent-
7DIN 38405-D 24: 1987-05; DIN EN ISO 10304-3: 1997-11; DIN EN ISO 23913: 2009-09; DIN EN ISO 18412: 2007-02; DIN 38405-D 27: 1992-07; DIN EN 1899-1: 1998-05; DIN EN 1899-2: 1998-05; DIN 38409-H 41: 1980-12; DIN 38409-H 44: 1992-05; DIN ISO 15705: 2003-01; DIN 38409-H 16-2: 1984-06; DIN 38409-H 16-1: 1984-06; DIN EN ISO 14402: 1999-12; DIN EN 872: 2005-04; DIN 38409-H 2-3: 1987-03; DIN 38409-H 7: 2005-12; DIN EN 1484: 1997-08; DIN EN 12260: 2003-12; DIN EN ISO 11905-1: 1998-08; DIN EN ISO 9562: 2005-02Effluent-
8DIN EN ISO 15088; DIN EN ISO 11348-1; DIN EN ISO 11348-2; DIN 38410-M 1; DIN 38412-L 16; DIN 38412-L 30; DIN 38412-L 33; DIN 38415-T 3Waste water-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Strandstraße 32 a, Ostseebad Nienhagen, 18211, DE

54.16308, 11.94793

Open in Maps

Accreditation data refreshed from the DAKKS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.